• 제목/요약/키워드: flat membrane

검색결과 176건 처리시간 0.019초

막 증발법을 이용한 셰일가스 폐수 처리 가능성 평가 (Feasibility study on shale gas wastewater treatment using membrane distillation)

  • 조형락;최용준;이상호
    • 상하수도학회지
    • /
    • 제30권4호
    • /
    • pp.441-447
    • /
    • 2016
  • Development of shale gas has drawn increasing attention since it is one of promising alternative energy resources. However, contamination of groundwater and surface water during the extraction of shale gas is becoming a serious environmental issues, which brings the needs to treat wastewater generated from hydraulic fracking. In this study, the feasibility of membrane distillation (MD) for the treatment of shale gas wastewater was investigated using a laboratory scale experimental setup. Flat-sheet MD membranes were used to treat produced water from a shale gas well in the United States. Different configurations such as direct contact MD (DCMD) and air gap MD (AGMD) were compared in terms of flux and fouling propensity. The foulants on the surface of the membranes were examined. The results suggest that MD can treat the shale gas produced water containing more than 200,000 mg/L of total dissolved solids, which is impossible by other technologies such as reverse osmosis (RO) and forward osmosis (FO). In this study, we investigated the possibility of processing and characterization of shale gas produce wastewater using membrane distillation. Laboratory scale membrane distillation experimental device was developed. It was compared the flat-sheet direct contact membrane distillation and flat-sheet air gap membrane distillation. AGMD flux in lower than the flux of DCMD, it was expected that the contamination caused by organic matters.

PTFE재질의 평판형 분리막과 인제거를 위해 Alum주입을 적용한 고플럭스 MBR시스템에 관한 연구 (A Study on the high-flux MBR system using PTFE flat membrane and coagulant(Alum) for removal of phosphorus)

  • 이의종;김관엽;권진섭;김영훈;이용수;이창하;전민정;김형수;김정래;정진호
    • 상하수도학회지
    • /
    • 제25권1호
    • /
    • pp.95-106
    • /
    • 2011
  • Even though MBR processes have many advantages such as high quality effluents, a small footprint and convenience for operation compared to conventional activated sludge processes, there are some shortcomings in terms of the cost and potential fouling incident that keeps MBR (Membrane bioreactor) processes from being widely applied. To reduce these problems, PTFE (Polytetrafluoroethylene) flat sheet membranes that have excellent permeability and durability were tested instead of PVDF (Polyvinylidene fluoride) membrane which is being used widely in water treatment. Low concentration of sodium hydroxide (NaOH) was also added into the membrane modules in order to prevent the membrane fouling as well as to provide the alkalinity. With conditions mentioned above, a pilot-scale MBR system based on the MLE (Modified Ludzack Ettinger) process was operated at flux of 40 $L/m^{2}/hr$ and over 15,000 mg/L MLSS concentration for about 8 months. And coagulant(alum) was added into the membrane tank to remove phosphorus. Although the more coagulant is added the more effectively phosphorus is removed, that can lead to fouling for a long operation(Ronseca et al.,2009). By the way there is a research that fouling grow up after stopping injection of coagulant(Holbrook, 2004). Stable operation of MBR systems was achieved without major chemical cleaning and the effluent quality was found to be good enough to comply with the treated waste water quality regulations of the Korea.

Si 입자를 함유한 반도체 세정폐수의 한외여과 특성[I] -Polysulfone 평판막에 의한 투과분리- (Permeation Behavior of Semiconductor Rinsing Wastewater Containing Si Particles in Ultrafiltration System -I. Permeation Characteristics of Polysulfone Flat Plate Membrane-)

  • 곽순철;이석기;전재홍;남석태;최호상
    • 멤브레인
    • /
    • 제8권2호
    • /
    • pp.102-108
    • /
    • 1998
  • 본 연구는 Si 미립자를 함유한 반도체 세정폐수의 평판막을 이용한 한외여과특성을 검토하였다. 평판막의 투과유속은 시간이 경과함에 따라 점차 감소하는 경향을 나타냈으며, 이현상은 막표면에 형성된 케익층의 증가 및 기공막힘에 기인한다. 흐름형태에 따른 투과유속은 cross flow가 dead-end flow의 약 1.4배 높았다. Si 미립자에 의한 막오염을 제거하는데는 역세법이 sweeping법 보다 우수하였다. 막오염으로 인한 투과유속의 감소는 질소가스로 역세척하여 초기투과유속의 약 85% 정도 회복되었다. 평판막을 이용한 cross flow 공정의 용질배제율은 약 90%였으며, 투과수증의 Si 미립자의 크기는 평균 70 nm였다.

  • PDF

Dean Vortices를 이용한 막모듈의 성능시험 (Performance Test for Membrane Module Using Dean Vortices)

  • Chung, Kun Yong;Belfort, Georges
    • 멤브레인
    • /
    • 제2권2호
    • /
    • pp.104-111
    • /
    • 1992
  • A curved channel duct is designed, built and used specifically to produce Dean vortices as a result of flow around a $180^{\circ}C$ curve. We present evidence using optical reflection of the existmace of the vortices in the curved section and following flat section. Also, three different feed soludons(DI water, a monodispersed styrene-divinyl-benzene latex particle suspension and a yeast suspension) were used to determine the effectiveness of Dean instabilities to destabilize polarization layers. For each suspension, the flux data were compared as a function of time for flow conditions with and without Dean vortices, for a $0.2{\mu}m$ microfiltration membrane. Any permeation flux improvement was not sustained for $2.0De_c$ due to the vortex-decay in the flat section after the curved channel, but a 15~30% permeation improvement was obtained for $3.8De_c$.

  • PDF

Harvesting of microalgae via submerged membranes: flux, fouling and its reversibility

  • Elcik, Harun;Cakmakci, Mehmet
    • Membrane and Water Treatment
    • /
    • 제8권5호
    • /
    • pp.499-515
    • /
    • 2017
  • The purpose of this study was to investigate membrane fouling caused by microalgal cells in submerged membrane systems consisting of polymeric and ceramic microfiltration membranes. In this study, one polymeric (flat-sheet, pore size: $0.2{\mu}m$) and two ceramic (flat-sheet, pore size: $0.2{\mu}m$ and cylindrical, pore size: $1{\mu}m$) membranes were used. Physical cleaning was performed with water and air to determine the potential for reversible and irreversible membrane fouling. The study results showed that substantial irreversible membrane fouling (after four filtration cycles, irreversible fouling degree 27% (cleaning with water) and 38% (cleaning with air)) occurs in the polymeric membrane. In cleaning studies performed using water and air on ceramic membranes, it was observed that compressed air was more effective (recovery rate: 87-91%) for membrane cleaning. The harvesting performance of the membranes was examined through critical flux experiments. The critical flux values for polymeric membrane with a pore size of $0.20{\mu}m$ and ceramic membranes with a pore size of $0.20{\mu}m$ and $1{\mu}m$ were ${\leq}95L/m^2hour$, ${\leq}70L/m^2hour$ and ${\leq}55L/m^2hour$, respectively. It was determined that critical flux varies depending on the membrane material and the pore size. To obtain more information on membrane fouling caused by microalgal cells, the characterization of the fouled polymeric membrane was performed. This study concluded that ceramic membranes with a pore size of $0.2-1{\mu}m$ in the submerged membrane system could be efficiently used for microalgae harvesting by cleaning the membrane with compressed air at regular intervals.

Defect-free 4-node flat shell element: NMS-4F element

  • Choi, Chang-Koon;Lee, Phill-Seung;Park, Yong-Myung
    • Structural Engineering and Mechanics
    • /
    • 제8권2호
    • /
    • pp.207-231
    • /
    • 1999
  • A versatile 4-node shell element which is useful for the analysis of arbitrary shell structures is presented. The element is developed by flat shell approach, i.e., by combining a membrane element with a Mindlin plate element. The proposed element has six degrees of freedom per node and permits an easy connection to other types of finite elements. In the plate bending part, an improved Mindlin plate has been established by the combined use of the addition of non-conforming displacement modes (N) and the substitute shear strain fields (S). In the membrane part, the nonconforming displacement modes are also added to the displacement fields to improve the behavior of membrane element with drilling degrees of freedom and the modified numerical integration (M) is used to overcome the membrane locking problem. Thus the element is designated as NMS-4F. The rigid link correction technique is adopted to consider the effect of out-of-plane warping. The shell element proposed herein passes the patch tests, does not show any spurious mechanism and does not produce shear and membrane locking phenomena. It is shown that the element produces reliable solutions even for the distorted meshes through the analysis of benchmark problems.

PVdF/GO 복합 나노섬유 평막의 제조 및 활성슬러지 내 투과특성 (Preparation of PVdF/GO Composite Nanofibrous Flat Membrane and its Permeation Characteristics in Activated Sludge)

  • 원인혜;장원기;정건용;변홍식
    • 멤브레인
    • /
    • 제25권1호
    • /
    • pp.67-74
    • /
    • 2015
  • 본 연구에서는 dimethylformamide (DMF)와 acetone의 혼합용액에 산화그래핀(graphene oxide, GO)을 분산시키고 기질 고분자인 PVdF (polyvinylidene fluoride)를 도입하여 전기방사법으로 나노섬유를 제조하였다. 또한 PVdF/GO 복합 나노섬유를 평막 형태로 적층시켜 기공크기 $0.4{\mu}m$인 정밀여과막을 제조하였다. 그리고 GO의 고유한 항균 특성으로 생물학적 오염을 줄일 수 있는 PVdF/GO 복합막의 막오염을 평가하기 위하여 막간 압력차(transmembrane pressure, TMP)를 측정하였다. 유효 막면적이 $0.01m^2$인 PVdF/GO 평막과 상용화된 MBR용 CPVC (chlorinated polyvinyl chloride) 평막을 MLSS 4,500 mg/L인 활성슬러지 수용액 내에서 동시에 투과 실험하였다. 공기를 주입하지 않을 경우, 투과유속이 $10L/m^2{\cdot}h$일 때 PVdF/GO 막의 TMP는 CPVC 막의 최대 79%까지 감소하였다. 또한 운전/휴직 방식으로 운전할 경우, $10L/m^2{\cdot}h$일 때 PVdF/GO 막의 TMP는 CPVC 막의 최대 69%까지 감소함을 확인하였다.

면내회전자유도를 가지는 4절점 비적합 평면쉘의 개발 (A 4-Node Non-conforming Flat Shell Element with Drilling DOF)

  • 최창근;이필승
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1998년도 가을 학술발표회 논문집
    • /
    • pp.27-34
    • /
    • 1998
  • A versatile flat shell element has been developed by combining a membrane element with drilling degree-of-freedom and a plate bending element. This element is formulated by the enhanced displacement field with the additional non-conforming displacement modes. Thus the element possesses six degrees-of-freedom (DOF) per node which permits an easy connection to other six DOF elements as well as the improvement of the element behavior. In plate bending part, this element is established by the combined use of the addition of non-conforming modes, the reduced (or selective) integration scheme, and the construction of the substitute shear strain fields. The achieved improvement may be attributable to the fact that the merits of these individual techniques are merged into the new element in a complementary manner. In membrane part, this element shows better membrane behavior as the nonconforming displacement mode is added to drilling mode.

  • PDF

Home-built Solid-state NMR Probe for Membrane Protein Studies

  • Kim, Yong-Ae;Hwang, Jung-Hyun;Park, Jae-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권9호
    • /
    • pp.1281-1283
    • /
    • 2003
  • Proteins in highly oriented lipid bilayer samples are useful to study membrane protein structure determination. Planar lipid bilayers aligned and supported on glass slide were prepared. These stack of glass slide with planar lipid bilayers are not well fit for commercial solid-state NMR probe with round coil. Therefore, homebuilt solid-state NMR probe was built and used for a stack of thin glass plates and RF coil is wrapping directly around the flat square sample. The overall filling factor of the coil is much better and the large surface area enhances the extent to orientation by providing uniform environments for the phospholipids and the high ratio of circumference to area reduces edge effects. $^1H\;and\;^{15}N$ double resonance probe for 400 MHz NMR (9.4T) with a flat coil (coil size: 11 mm ${\times}$ 20 mm ${\times}$ 4 mm) is constructed and tested.

금속연료전지에서 이온교환막이 전기전도에 미치는 영향 (The Effect of Ion Exchange Membrane on the Electrical Conduction in Metal Fuel Cell)

  • 김용혁
    • 전기학회논문지
    • /
    • 제59권12호
    • /
    • pp.2235-2239
    • /
    • 2010
  • In this study, The cation exchange membrane and the anion exchange membrane affect in electrical conduction of metal fuel cell was investigated. Magnesium material as anode electrode and the NaCl solution dissolved with 5~15wt% as electrolyte were used for the metal fuel cell. It was found that magnesium slag where flows toward the air electrode was suppressed by using ion exchange membrane. The open circuit voltage variation during discharge has very flat pattern by using ion exchange membrane, but the case which is not the exchange membrane, the open circuit voltage increased according to time. When using the anion exchange membrane, the electric current was higher case of the cation exchange membrane, as a result of higher equivalent conductivity in anion Cl-. The cation exchange membrane was observed with the fact that the output power is excellent in compared with anion exchange membrane.