• Title/Summary/Keyword: flammable

Search Result 509, Processing Time 0.033 seconds

Analysis of forest fire danger rating on the forest characteristic of thinning area and non-thinning area (숲 가꾸기 실행 및 미실행지의 임분특성에 따른 산불위험도 분석)

  • Lee, Si-Young;Lee, Myung-Woog;Chae, Hee-Min;Won, Myoung-Soo;Yeom, Chan-Ho
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.217-222
    • /
    • 2007
  • Since 1973, we attain a successful achievement of nation-wide afforestation such as a thick forest and heaped-up leaves. However, the higher of the formation density in forest, the more dangerous to be a large-scale forest fire whenever fire occurs. According to the type of forest in the country, 42% of the forest is occupied by conifer forest that are highly flammable, and the distribution of forest age is in a transition period from immature forest to mature one. And the structure is too weak to the forest fire for the occurrence and spread because there are too many scrub and shrub trees in the forest. As a matter of course, it is on the increase of the thinning-forest that can shift the forest structure from a weak on forest fire to a strong one nowaday. In other words, thinning-forest has primary purposes such as the promotion of producing forest trees, production of excellent timbers, and build-up of public forest area. Furthermore, in some reports, the reduction of ladder fuel by eliminating the vertical/horizontal fuel in a forest and ensuring spaces in the forest can decrease the occurrence of forest fire and the risk of spread of burning as by-effect. Therefore, this study is designed to clarify the relation with the risk of forest fire by an on-spat-investigation of the characteristics of forest composition on the thinning and the non-thinning area.

  • PDF

A Study on Developing of Soldering Flux (납땜 플럭스 개발에 관한 연구)

  • 이통영
    • Fire Science and Engineering
    • /
    • v.14 no.2
    • /
    • pp.33-38
    • /
    • 2000
  • Flux, essentially used in soldering process of PCB (Printed Circuit Board) in electronics industry, contains IPA (Isopropyl alcohol) and methanol, which are highly inflammable and explosive. Hazard Chemical Controlling Law classified methanol as toxic material and Environmental Law classified methanol as VOC (Volatile Organic Compound). So there have been pressing needs of developing substitutes for the existing Flux. New solvent which is non-flammable and main component is DCP having same specific character of the existing Flux. It's been combirated with proper composition ratio adding stabilizer. As a result, it relieved working Environment Allowance thickness 200 ppm to 470 ppm, chance of not been soldered 0.083% to 0%, spread 85% to 87%, power saving resistance 1.0$\times$$10^{12}$$\Omega$ to 6.9$\times$$10^{12}$$\Omega$, which means a lot better than the existing Flux. Therefore, Flux confirmed the chance of improving productivity, safety, environment safety and quality. Also, Flux got a satisfied result after product quality test and product reliability test.

  • PDF

Performance of R1234yf and R1234yf/R134a Mixture under Mobile Air-conditioner Operating Conditions (R1234yf와 R1234yf/R134a의 자동차 에어컨 작동 조건에서의 성능 평가)

  • Park, Ki-Jung;Lee, Yo-Han;Choe, Dae-Seong;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.12
    • /
    • pp.837-844
    • /
    • 2010
  • In this study, performance of R1234yf and R1234yf/R134a mixture is measured on a heat pump bench tester in an attempt to substitute R134a used widely in mobile air conditioners (MACs). The bench tester is equipped with a open type compressor providing a nominal capacity of 3.5 kW. All tests are conducted under the summer cooling and winter heating conditions of 7/4 $5^{\circ}C$ and $-7/41^{\circ}C$ in the evaporator and condenser, respectively. For R1234yf/R134a mixture, measurements are made at 5%, 10%, and 15% of R134a by mass. Test results show that the coefficient of performance (COP) and capacity of R1234yf are up to 2.7% and 4.0% lower than those of R134a, respectively. For R1234yf/R134a mixture, the COP and capacity are up to 3.9% lower and 3.6% higher than those of R134a. For R1234yf and R1234yf/R134a mixture, the compressor discharge temperature is $4.1{\sim}6.7^{\circ}C$ lower than that of R134a while the amount of charge is reduced up to 11% as compared to R134a. 90%R1234yf/10%R134a is a better refrigerant than pure R1234yf in that it is less flammable and more compatible with existing R134a system. Based upon the results, it is concluded that R1234yf and R1234yf/R134a mixture are long term environmentally friendly solutions to mobile air-conditioners due to their excellent environmental properties with acceptable performance.

Prediction of Minimum Oxygen Concentration(MOC) of Hydrocarbons and Halogenated Hydrocarbons (탄화수소 및 할로겐화탄화수소의 최소산소농도(MOC)의 예측)

  • Ha Dong-Myeong;Jeong Kee-Sin
    • Fire Science and Engineering
    • /
    • v.19 no.2 s.58
    • /
    • pp.1-7
    • /
    • 2005
  • An accurate knowledge of the minimum oxygen concentration(MOC) is important in developing appropriate prevention and control measures in industrial fire protection. In this study, by using the literature data and RSM(response surface methodology), the new equations for predicting the MOC are proposed. The A.A.P.E.(average absolute percent error) and the A.A.D.(average absolute deviation) of the reported and the calculated MOC for hydrocarbons were $3.48\%\;and\;0.37\;vol\%$, respectively and the correlation coefficient was 0.919. The A.A.P.E and the A.A.D of the reported and the calculated MOC for halogenated hydrocarbons and hydrocarbons were $5.06\%$ and $0.59vo1\%$, and the correlation coefficient was 0.938. The values calculated by the proposed equations were in good agreement with the literature data. Therefore, it is expected that this proposed equations will support the use of the research for other flammable substances.

The Measurement of Lower Flash Point for tert-Pentanol+n-Decane System Using Tag Open-Cup Tester (Tag 개방식 장치를 이용한 tert-Pentanol+n-Decane 계의 하부인화점 측정)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.5
    • /
    • pp.41-46
    • /
    • 2012
  • The flash point the lowest temperature at which the concentration of vapor of the substance in the air reaches the lower flammability limit(LFL), and is one of the most important physical properties used to determine the potential for fire and explosion hazards of industrial materials. The most published flash point data was for pure components and the flash points of the binary solutions that have flammable components, appear to be scarce in the literature. In the present study, the flash points of tert-pentanol+n-decane system were measured by Tag open-cup tester. The measured data were compared with the values calculated by the Raoult's law and the optimization methods based on the Wilson and NRTL equations. The calculated values by optimization methods were found to be better than those based on the Raoult's law.

Consequence Analysis of the Fire & Explosion on the Flammable Liquid Handling Facility and LPG Station (제 4류 위험물 취급소 및 LPG 충전소의 화재$\cdot$폭발 피해 영향분석)

  • Lee Su-Kyung;Lee Chang-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.3 no.2 s.7
    • /
    • pp.77-84
    • /
    • 1999
  • The XX company that is handling the class IV hazardous materials, located in Bu-Chon City and the LPG station in front of the XX company which is about 20 meters apart, was chosen as the standard model for this study In carrying out the consequence analysis, PHAST and Super-Chems were used for the study and utilizing the output of the simulation, we have evaluated the consequences throughout the probit analysis and explosion overpressure analysis. In case of Acetone, the effect distance of the damage on facilities-that is the result of radiation heat flux of $37.5kW/m^2$ by TNO model-is 68.51m by PHAST model and 40.93m by Super-Chem model. The risk assessment of the LPG station which is based on the explosion resulted as the analysis of the fire ball showed the diameter 125.2m, the height 206.2m and the duration 11.28sec and the effect distance for the radiant heat flux $37.5kW/m^2$ was 137.0m.

  • PDF

A Study on Semi Quantitative Risk Analysis for Air Separation Unit using a GRA(Generic Risk Analysis) Method (GRA(Generic Risk Analysis) 기법을 이용한 공기분리시설에 대한 준 정량적 위험성 평가에 관한 연구)

  • Shin, Jung-Soo;Byun, Hun-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.1
    • /
    • pp.56-66
    • /
    • 2013
  • The gas production plants supply the inert gas to production plants for maintaining safe operation and also supply combustible, flammable, explosive and toxic gases as functions of basic materials needed for producing chemical goods. In addition, gas plants need to be safe and reliable operation because they are operated under high temperature, high pressure, cryogenic and catalytic reactions. As these plants have a complex process in operation, there has been a risk that major industrial accidents such as a fire, explosion and toxic gas released, also risks of asphyxiations by inert gases and burns caused by high temperature and cryogenic substances. This study is to carry out the semi quantitative risk assesment method which is the generic risk analysis (GRA). This method is applied to air separation unit(ASU) to identify its initial risk, safety barriers, residual risk and elements important for safety(EIS). The result of this study, suggested the management tools and procedures of implementation for EIS management.

Analysis of Gas Flow Behavior with Experiments for LPG releasing and 3D Mapping of Gas Sensor (LPG 누출 및 가스센서 3D Mapping을 통한 가스유동현상 분석)

  • Kim, Jeong Hwan;Lee, Min-Kyung;Kil, Seong-Hee;Lee, Jin-han;Jo, Young-do;Moon, Jong-Sam
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.5
    • /
    • pp.45-55
    • /
    • 2017
  • Release and fire/explosion tests of flammable gas are extremely dangerous. Furthermore, it is difficult to select the site where the experiment can be performed. In these reasons, gas flow analysis(CFD) has been used as much as possible. However, with the opening of the Energy Safety Empirical Research Center in Yeongwol-gun, Gangwon-do in October 2016, it was possible to conduct releases and detection tests of small scale combustible gas as well as large scale / high pressure / ultra low temperature experiments. In this study, LPG leaked after the calibration and placement of the sensor, the sensor detected LPG and the data were visualized as a contour map. And the differences between the actual release(28s, max 3.7[m]) and the analysis were analyzed compared to the FLACS analyzed under the same conditions.

The Calculation of Flash Point for n-Nonane+n-Decane+n-Tridecane System by Raoult's Law and Multiple Regression Analysis (라울의 법칙과 다중회귀분석법에 의한 n-Nonane+n-Decane+n-Tridecane 계의 인화점 계산)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.2
    • /
    • pp.52-58
    • /
    • 2018
  • The flash point is one of the most important properties to characterize fire and explosion hazard of flammable liquid mixture. In this paper, the flash points of ternary liquid mixture, n-nonane+n-decane+n-tridecane system, were measured using Seta flash closed cup tester. The measured values were compared with the calculated values using Raoult's law and multiple regression analysis. The absolute average errors(AAE) of the results calculated by Raoult's law is $0.6^{\circ}C$. The absolute average errors of the results calculated by multiple regression analysis is $0.4^{\circ}C$. As can be seen from AAE, the calculated values based on multiple regresstion analysis were found to be better than those based on Raoult's law.

Study on the Development Trend of Pressurization System for Propulsion System of Launch Vehicle (발사체 추진기관 가압시스템 개발 사례 연구)

  • Shin, Dong-Sun;Kim, Byung-Hun;Han, Sang-Yeop
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.721-724
    • /
    • 2011
  • A system to pressurize propellants stored in propellant tanks is necessary to feed liquid-propellants into combustion devices at the required pressure and flowrate without having cavitation in turbo-pumps. A pressurization system can be categorized into pre-pressurization stage and main-pressurization stage. This report is regarding to a main-pressurization system. Pressurization methods for propellant tanks are divided into pressurant gas generating method and pressurant gas feeding method. One of pressurant gas generating methods uses the vaporized oxygen gas from cryogenic liquid oxygen and non-flammable gas. In this report, both advantages and disadvantages for pressurization methods and types of pressurization systems are compared. Especially the characteristics and principle of pressurization system using impulsive control strategy applied in launch vehicles are introduced. Additionally the structure, schematics, and specifications of heat exchanger, which is one of main units in pressurization system are also discussed. This paper can be utilized to generate the conceptual requirements and to design preliminary configuration of pressurization system during the development of launch vehicle.

  • PDF