• Title/Summary/Keyword: flame temperature

Search Result 1,299, Processing Time 0.025 seconds

A Numerical Study for Effective Operation of MSW Incinerator for Waste of High Heating Value by the Addition of Moisture Air (함습공기를 이용한 고발열량 도시폐기물 소각로의 효율적 운전을 위한 수치 해석적 연구)

  • Shin, Mi-Soo;Shin, Na-Ra;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.2
    • /
    • pp.115-123
    • /
    • 2013
  • Stoker type incinerator is one of the most popular one used as municipal solid waste (MSW) incineration because, in general, it is quite suitable for large capacity and need no preprocessing facility. Nowadays, however, since the combustible portion of incoming MSW increases together with the decrease of the moisture content due to prohibition of directly burying food waste in landfill, the heating value of waste is remarkably increasing in comparison with the early stage of incinerator installation. Consequently, the increased heating value in incinerator operation causes a number of serious problems such as reduction of waste amount to be burned due to the boiler heat capacity together with the significant NO generation in high temperature environment. Therefore, in this study, a series of numerical simulation have been made as parameters of waste amount and the fraction of moisture in air stream in order to investigate optimal operating condition for the resolution of the problems associated with the high heating value of waste mentioned above. In specific, a detailed turbulent reaction flow field calculation with NO model was made for the full scale incinerator of D city. To this end, the injection method of moisturized air as oxidizer was intensively reviewed by the addition of moisture water amount from 10% and 20%. The calculation result, in general, showed that the reduction of maximum flame temperature appears consistently due to the combined effects of the increased specific heat of combustion air and vaporization heat by the addition of water moisture. As a consequence, the generation of NOx concentration was substantially reduced. Further, for the case of 20% moisture amount stream, the afterburner region is quite appropriate in temperature range for the operation of SNCR. This suggests the SNCR facility can be considered for reoperation. which is not in service at all due to the increased heating value of MSW.

Studies on the Stabilization of Rayon Fabrics: 3. Effects of Long-Term Isothermal Stabilization at Low Temperatures and Chemical Pre-treatment (레이온직물의 안정화에 관한 연구: 3. 저온 장시간 등온 안정화 및 화학전처리 영향)

  • Cho, Chae Wook;Cho, Donghwan;Park, Jong Kyoo;Lee, Jae Yeol
    • Journal of Adhesion and Interface
    • /
    • v.11 no.1
    • /
    • pp.15-25
    • /
    • 2010
  • In the present study, isothermal stabilization processes for rayon fabrics were performed at two relatively low temperatures $180^{\circ}C$ and $200^{\circ}C$ for a long period of time. The results of weight loss, dimensional shrinkage, X-ray diffraction and scanning electron microscopic observations studied with the rayon fabrics before and after the isothermal stabilization indicated that the chemical and physical changes of rayon precursor fibers proceeded continuously and slowly at the stabilization temperature below $200^{\circ}C$. And the pre-treatment with four different chemical compounds done prior to stabilization process influenced differently the characteristics of rayon fabrics. As a result, it was noticed that under the given stabilization conditions, $H_3PO_4$ and $Na_3PO_4$ played a role in catalyzing the stabilization reaction of rayon fabric whereas $NH_4Cl$ and $ZnCl_2$ played a role in delaying or retarding the reaction. $H_3PO_4$ showed the lowest percent weight loss of the fabric in the second stabilization conducted at $350^{\circ}C$. It was considered that phosphoric acid, which has a function of flame retardant, contributed to retarding somewhat the subsequent reaction even in the second stabilization step.

Evaluation of the combustion chamber for burning candle and measuring the emission factor of its’ combustion products (양초 연소 시 발생되는 오염물질 방출계수 측정을 위한 연소실 제작과 평가)

  • Lim, Hyung-Jin;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.236-245
    • /
    • 2015
  • Recently, candles have been widely used to create a romantic atmosphere and to heat tea. In this study, a small combustion chamber for candle was designed using an 0.008 m3 bell jar. The emission factors of combustion products were then measured. The combustion chamber includes a glass dish, which prevents candle flame from affecting the composition of the gas emitted through the exhaust outlet. The outlet in the combustion chamber was designed as a cone shape, and it was lengthened to prevent flow from the outside, which could affect the homogeneous composition of the exhaust gas. The temperature at the outlet of the chamber was 34 ℃~41℃. The major combustion products of the candle, such as such aldehydes and acids, contained oxygen. The mass specific emission rates of benzene, toluene, ethylbenzene, and TVOC were 0.04 μg/g, 0.01 μg/g, 0.02 μg/g, and 3.81, respectively. The mass specific emission rates of formaldehyde, acetaldehyde and benzaldehyde were 4.48 μg/g, 1.09 μg/g, and 0.67 μg/g, respectively. Considering the different compositions of the candle samples, their mass specific emission rates were similar to those obtained by using a large chamber 0.17 m3~50 m3 in size.

A Study on Characteristics of Exposure to Tetrahydrofuran of Manufacturing and Handling Workers (테트라하이드로퓨란 제조 및 취급 근로자의 노출특성에 관한 연구)

  • Chio, Ho Chun;Hong, Jwa Ryung;Lee, Gye Young;Kim, Doo Ho;Park, Chung Yill
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.21 no.3
    • /
    • pp.156-161
    • /
    • 2011
  • Objectives: Tetrahydrofuran (THF) is a colorless, water-miscible organic liquid with low viscosity at standard temperature and pressure. THF has been used as a solvent and a precursor for various syntheses of polymers. However, THF is known to irritate to the eyes, skin and mucus membranes. Overexposure by inhalation, ingestion or skin contact may produce nausea, dizziness, headaches, respiratory irritation and possible skin burns. The purpose of this study is to evaluate of the worker exposure and characteristics of workers in the workplaces that use or manufacture THF. Methods: Sixteen factories in Korea, which manufacture or use THF, were selected for this study and a total of 130 air samples including 104 time-weighted average (TWA) samples and 26 short-term exposure limit (STEL) samples, were collected. Air samples were collected with charcoal tube (100mg/50mg) and analyzed by gas chromatograph/flame ionization detector(GC/FID). Results: The TWA concentration of THF was 16.05ppm (GM) at PS script printing, 2.32ppm (GM) at PVC stabilizer, 1.03ppm (GM) at Lithium triethylborohydride, 0.63ppm (GM) at Polytetramethylene ether glycol(PTMEG), 0.42ppm (GM) at Manufacturing THF, 0.13ppm (GM) at Glue and 0.12ppm (GM) at synthetic rubber/resins. Two out of sampes for PS script printing exceeded 50ppm as 8-hour exposure limit of MOEL. The short term exposure to THF was 54.77ppm (GM) at PS script printing, 17.10ppm (GM) at PTMEG, 13.76ppm (GM) at Manufacturing THF, 2.86ppm (GM) at Lithium triethylborohydride, 0.87ppm (GM) at synthetic rubber/resins and 0.13ppm (GM) Glue. We found that the highest exposure process for both the TWA and STEL samples was PS script process. Two samples exceeded 100ppm as short term exposure limit of Ministry of Employment and Labor(MOEL). Conclusions: Characteristic of STEL concentration for THF is considerably different from TWA concentration in workplaces because workers could exposure high concentration of THF in a moment when they work irregularly schedule. So exposure controls for momentary works have to be prepared, and considered the skin absorption and inhale of THF.

Characteristics of a Plasma-Dump Combustor for VOC Destruction (VOC 분해 플라즈마-덤프 연소기 특성)

  • Kim, Eun Hyuk;Chun, Young Nam
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.8
    • /
    • pp.492-497
    • /
    • 2015
  • VOCs (Volatile Organic Compounds) are generally generated in the painting process, or at the company and laundry where use organic solvents. The VOCs consist of various hydrocarbons and has low calorific value due to its dilution with atmospheric air. Therefore, the VOCs are difficult to burn by a conventional fuel combustor. In this study, a novel plasma dump combustor was proposed for the treatment of low calorific VOC gases. This combustor was designed a combination of the characteristics in a plasma burner, a dump combustor and a 3D matrix burner. The combustor has good structure for maintaining enough residence time and reaction temperature for stable flame formation and VOC destruction. For investigating the performance characteristics of the plasma dump combustor, an experiment was achieved for VOC feed rate, VOC injector position, etc. Toluene was used as a surrogate of VOC. The novel combustor gave better performance than a conventional combustor, showing that VOC destruction rate and energy efficiency were 89.64% and 12.27 kg/kWh respectively, at feeding rate of 450 L/min of VOC of 3,000 ppm of toluene concentration.

Combustion characteristics of two imported Indonesia coals as a pulverized fuel of thermal power plants (인도네시아산 발전용 수입 석탄 2종의 연소특성 비교 평가)

  • Lee, Hyun-Dong;Kim, Jae-Kwan
    • Journal of Energy Engineering
    • /
    • v.19 no.2
    • /
    • pp.136-142
    • /
    • 2010
  • Combustion reactivity and thermal behavior of two imported coals used as a pulverized fuel of commercially thermal power plant were investigated by thermogravimetric analysis (TGA) and large scale test furnace of 200 kg/hr. TGA results showed that combustion efficiency of high moisture coal has lower than reference coal due to the slow combustion completion rate although it has the low ignition temperature, and activation energies of high moisture coal with 79 kJ/mol for overall combustion was higher than reference coal of 53 kJ/mol. Test furnace results ascertained that flame of black band of high moisture coal during the combustion in boiler broke out compared to reference coal and then it becomes to unburned carbon due to the less reactivity and combustion rate. But, Blending combustion of high moisture coal with design coal of high sulfur are available because sulfur content of high moisture coal was too low to generate the low SOx content in flue gas from boiler during the combustion. The ash analysis results show that it was not expected to be associated with slagging and fouling in pulverized coal fired systems due to the low alkali metal content of $Na_2O$ and $K_2O$ compared to bituminous coal.

Preparation and Properties of Low Density Polyethylene/Organo-clay Nanocomposite (저밀도 폴리에틸렌 나노복합재료의 제조 및 특성)

  • Moon, Sung-Chul;Jung, Hyo-Sun;Lee, Jae-CHul;Hong, Jin-Who;Choi, Jae-Kon;Jo, Byung-Wook
    • Applied Chemistry for Engineering
    • /
    • v.16 no.1
    • /
    • pp.52-60
    • /
    • 2005
  • In this study, low density polyethylene/organo-clay nanocomposites were prepared by melt blending. Thermal property, structure, and morphology of the LDPE/organo-clay nanocomposites were investigated. When the composition ratios of the compounds of LDPE/PE-g-MA/organo-clay were 90/10/1~10 (w/w/w), X-ray diffractograms of LDPE/organo-clay nanocomposites revealed that the intercalation of polymer chains lead to increase the spacing between clay layers. TEM microphotographs showed that LDPE was intercalated into organo-clay. TGA performed under air atmosphere demonstrated a great increase in thermal stability of the LDPE/organo-clay nanocomposties. The maximum decomposition temperature of LDPE/organo-clay nanocomposite was increased about $80^{\circ}C$ compared with pure LDPE. When the organo-clay contents were 1.0~5.0 wt%, the LOI values were increased with increasing the organo-clay content, but in the case of the contents more than 5.0 wt%, the LOI values were not increased any more.

The Processing of Causative and Passive Verbs in Korean (한국어의 사.피동문 처리에 관한 연구:실어증 환자의 처리 양상을 바탕으로)

  • 문영선;김동휘;남기춘
    • Proceedings of the Korean Society for Cognitive Science Conference
    • /
    • 2000.05a
    • /
    • pp.267-272
    • /
    • 2000
  • 본 연구에서는 한국어의 사·피동문을 실어증 환자가 처리하는 양상에 대하여 살펴보았다. 한국어의 사·피동문은 용언에 파생접사가 붙어 이루어지는 경우와 '-게 하다'나 '-어 지다'와 같이 구문 변형으로 하여, 실어증 환자에게 실험을 하였다. 실험에 참여한 환자는 명칭성 실어증 환자, 이해성 실어증 환자, 표현성 실어증 환자, 전반성 실어증 환자로 구성되어 있다. 본 실험에서는 단어 채워 넣기 과제(word completion task)를 사용하였다. 명칭성 실어증 환자의 경우 피동에서는 처리 오류를 보이는 반면, 사동에는 아무런 문제도 보이지 않았다. 표현성 실어증 환자의 경우, <피동-비변형>에서 오류를 많이 보였다. 이를 통해 한국어의 사·피동은 영어와 달리 통사상의 문제가 아니라는 결론을 내릴 수 있다. 즉 이미 사·피동 접사에 의해 파생된 단어가 어휘부에 저장되어 있고, 각 단어의 논항 정보에 따라 문장이 생성되는 것이다. 표현성 실어증 환자가 피동의 비변형에서 지배적인 오류를 보이는 것은 피동의 비변형이 타동사로서 변형인 피동형에 비해 하나의 논항을 더 취하기 때문이다. 이해성 실어증 환자의 경우 사·피동 생성에 별 어려움을 보이지 않았다. 이는 이해성 실어증 환자가 개별 어휘의 논항 정보에 손실을 적게 입고 있음을 시사하는 결과이다. 본 연구에서는 서로 다른 유형을 보이는 환자들을 대상으로 한국어의 사·피동의 처리양상을 대조한 결과, 첫재 사·피동은 서로 다른 통사, 의미상의 처리 양상을 보이고 있고, 둘째 파생접사가 결합된 형태로 어휘부에 저장되어 있는 개별 사·피동사에 의해 형성되는 것임을 확인하였다.d CO2 quantity causes flame temperature to fall since at high strain retes diluent effect is prevailing and at low strain rates the products inhibits chain branching. It is also found that the contribution of NO production by N2O and NO2 mechanisms are negligible and that thermal mechanism is concentrate on only the reaction zone. As strain rate and CO2 quantity increase, NO production is remarkably augmented.our 10%를 대용한 것이 무첨가한 것보다 많이 단단해졌음을 알 수 있었다. 혼합중의 반죽의 조사형 전자현미경 관찰로 amarans flour로 대체한 gluten이 단단해졌음을 알수 있었다. 유화제 stearly 칼슘, 혹은 hemicellulase를 amarans 10% 대체한 밀가루에 첨가하면 확연히 비용적을 증대시킬 수 있다는 사실을 알 수 있었다. quinoa는 명아주과 Chenopodium에 속하고 페루, 볼리비아 등의 고산지에서 재배 되어지는 것을 시료로 사용하였다. quinoa 분말은 중량의 5-20%을 quinoa를 대체하고 더욱이 분말중량에 대하여 0-200ppm의 lipase를 lipid(밀가루의 2-3배)에 대하여 품질개량제로서 이용했다.

  • PDF

A study on the Application of Optimal Evacuation Route through Evacuation Simulation System in Case of Fire (화재발생 시 대피시뮬레이션 시스템을 통한 최적대피경로 적용에 관한 연구)

  • Kim, Daeill;Jeong, Juahn;Park, Sungchan;Go, Jooyeon;Yeom, Chunho
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.96-110
    • /
    • 2020
  • Recently, due to global warming, it is easily exposed to various disasters such as fire, flood, and earthquake. In particular, large-scale disasters have continuously been occurring in crowded areas such as traditional markets, facilities for the elderly and children, and public facilities where various people stay. Purpose: This study aims to detect a fire occurred in crowded facilities early in the event to analyze and provide an optimal evacuation route using big data and advanced technology. Method: The researchers propose a new algorithm through context-aware 3D object model technology and A* algorithm optimization and propose a scenario-based optimal evacuation route selection technique. Result: Using the HPA* E algorithm, the evacuation simulation in the event of a fire was reproduced as a 3D model and the optimal evacuation route and evacuation time were calculated for each scenario. Conclusion: It is expected to reduce fatalities and injuries through the evacuation induction technique that enables evacuation of the building in the shortest path by analyzing in real-time via fire detection sensors that detects the temperature, flame, and smoke.

A Study on the Test and Installation Standards of the Video Fire Detector (영상화재감지기 시험과 설치기준에 관한 연구)

  • Lee, Jeong-Hyun;Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.1-5
    • /
    • 2016
  • This research performed tests of Video Fire Detector and criteria of installation to make suggestions regarding the criteria that must be reflected in NFSC 203 by comparing the standards of FM Approvals, UL, ISO7240 and NFPA 72. FM Standard related to Video Fire Detector test has been classified as Smoke, Flame type, but the UL Standard has classified only as a Smoke type. This research examined 6 cases of fire phenomenon detection case in ISO 7240 and 3 cases in NFPA 72, respectively. There are 15 items required for the installation standard of a Video Fire Detector and each field standard is presented as a per installation method. To apply a Video Fire Detector, the pertinent items (the definition of term, detector's classification, structure and function among its test item) must be inserted. In addition, 7 items of the fire test, i.e., the sensitivity adjustment, prevent false alarm, ambient temperature test, the effective sensitivity and detection distance and viewing angle, aging test, flood test, must be applied to the actual test. For installation in the field, the operation environment and levels of illumination, and NFSC 203 must be set, and standards relevant to the sound system, indicators' installation distance, etc. need to be inserted.