• Title/Summary/Keyword: fixed precision

Search Result 404, Processing Time 0.028 seconds

Development of Sequential Sampling Plans for Tetranychus urticae in Strawberry Greenhouses (딸기 온실에서 점박이응애의 축차표본조사법 개발)

  • Choe, Hojeong;Kang, Juwan;Jung, Hyojin;Choi, Sira;Park, Jung-Joon
    • Korean Journal of Environmental Biology
    • /
    • v.35 no.4
    • /
    • pp.427-436
    • /
    • 2017
  • A fixed-precision-level sampling plan was developed to establish control of the two-spotted spider mite, Tetranychus urticae, in two strawberry greenhouses (conventional plot, natural enemy plot). T. urticae was sampled by taking a three-leaflet leaf (1 stalk) from each plant (3 three-leaflet leaves) from each sampling position. Each leaflet was divided into three different units (1-leaflet, 2-leaflet, and 3-leaflet units) to compare relative net precision (RNP) values for selection of the appropriate sampling unit. The relative net precision values indicated that a 1-leaflet unit was more precise and cost-efficient than other units. The spatial distribution analysis was performed using Taylor's power law (TPL). Homogeneity of the TPL parameters in each greenhouse was evaluated by using the analysis of covariance (ANCOVA). A fixed-precision-level sequential sampling plan was developed using the parameters of TPL generated from the combined data of the conventional plot and natural enemy plot in a 1-leaflet sampling unit. Sequential classification sampling plans were also developed using the action threshold of 3 and 10 mites for pooled data. Using the results obtained in the independent data, simulated validation of the developed sampling plan by Resampling validation for sampling plan (RVSP) indicated a reasonable level of precision.

Effect of posterior span length on the trueness and precision of 3 intraoral digital scanners: A comparative 3-dimensional in vitro study

  • Fattouh, Mohamed;Kenawi, Laila Mohamed Mohamed;Fattouh, Hesham
    • Imaging Science in Dentistry
    • /
    • v.51 no.4
    • /
    • pp.399-406
    • /
    • 2021
  • Purpose: This in vitro study measured and compared 3 intraoral scanners' accuracy (trueness and precision) with different span lengths. Materials and Methods: Three master casts were prepared to simulate 3 different span lengths (fixed partial dentures with 3, 4, and 5 units). Each master cast was scanned once with an E3 lab scanner and 10 times with each of the 3 intraoral scanners (Trios 3, Planmeca Emerald, and Primescan AC). Data were stored as Standard Tessellation Language (STL) files. The differences between measurements were compared 3-dimensionally using metrology software. Data were analyzed using 1-way analysis of variance with post hoc analysis by the Tukey honest significant difference test for trueness and precision. Statistical significance was set at P<0.05. Results: A statistically significant difference was found between the 3 intraoral scanners in trueness and precision (P<0.05). Primescan AC showed the lowest trueness and precision values(36.8 ㎛ and 42.0 ㎛;(39.4 ㎛ and 51.2 ㎛; and 54.9 ㎛ and 52.7 ㎛) followed by Trios 3 (38.9 ㎛ and 53.5 ㎛; 49.9 ㎛ and 59.1 ㎛; and 58.1 ㎛ and 64.5 ㎛) and Planmeca Emerald (60.4 ㎛ and 63.6 ㎛; 61.3 ㎛ and 69.0 ㎛; and 70.8 ㎛ and 74.3 ㎛) for the 3-unit, 4-unit, and 5-unit fixed partial dentures, respectively. Conclusion: Primescan AC had the best trueness and precision, followed by Trios 3 and Planmeca Emerald. Increasing span length reduced the trueness and precession of the 3 scanners; however, their values were within the accepted successful ranges.

Hybrid Prosthesis Supported by Osseointegrated Implants in Maxilla (골유착성 임프란트에 의해 지지되는 새로운 설계의 Hybrid Prosthesis)

  • Lee, J.S.;Shin, S.W.
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.8 no.1
    • /
    • pp.46-59
    • /
    • 1999
  • A fixed bridge is preferred as a prosthetic option supported by oral implants. However, it is very difficult to re tore edentulous maxilla with fixed prosthesis in cases with improper position and angulation of fixtures, abnormal jaw relation, and need for proper lip support. Six Br${\aa}$nemark implants were installed in edentulous maxilla opposing mandible with natural dentition. A removable hybrid prosthesis attached to a bar milled by 6 degrees was therefore designed to overcome such disadvantages of fixed prosthesis. Lateral stabilization of removable prosthesis was obtained by framework closely fitting the milled bar. Support for the prosthesis was ensured by three elevated areas on the bar. Two precision attachments(CEKA REVAX) provided appropriate direct and indirect retention without influencing support. A clinical and laboratory procedure was presented.

  • PDF

A Study on optical glass polishing using Fixed Abrasive Pad (고정입자패드를 이용한 광학 유리 폴리싱에 관한 연구)

  • 최재영;김초윤;박재홍;정해도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.78-81
    • /
    • 2003
  • Polishing Processes are widely used in the glass, optical, die and semiconductor industry and are conventionally carried out using abrasive slurry and a polishing pad. But abrasive slurry process has a weak point that is high cost of handling of used slurry and hard controllability of slurry. Recently, some researches have attempted to solve these problems and one method is the development of a fixed abrasive pad. FAP has a couple of advantages including clean environment, lower CoC, easy controllability and higher form accuracy. But FAP also has a weak point that is need of dressing because of glazing and loading. The paper introduces the basic concept and fabrication technique of FAP using hydrophilic polymers with swelling characteristics in water and explains the self-conditioning phenomenon. Experimental results demonstrate to achieve nano surface roughness of soda lime glass for optical application

  • PDF

Evaluation on Tungsten CMP Characteristic using Fixed Abrasive Pad with Alumina (알루미나 고정입자패드를 이용한 텅스텐 CMP 특성 평가)

  • 박범영;김호윤;김형재;서헌덕;정해도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.206-209
    • /
    • 2002
  • The fixed abrasive pad(FAP) has been introduced in chemical mechanical polishing(CMP) field recently. In comparison with the general CMP which uses the slurry including abrasives, FAP takes advantage of planarity. resulting from decreasing pattern selectivity and defects such as dishing due to the reduction of abrasive concentration especially. This paper introduces the manufacturing technique of $Al_2$O$_3$-FAP using hydrophilic polymers with swelling characteristic in water and explains the self.texturing phenomenon. It also focuses on the chemical effects on tungsten film and the FAP is evaluated on the removal rate as a function of chemicals such as oxidizer, catalyst, and acid. The removal rate is achieved up to 1000A1min as about 70 percents of the general one. In the future. the research has a plan of the advanced FAP and chemicals in tungsten CMP considering micro-scratch, life-time, and within wafer non-uniformity.

  • PDF

A Study on the Development of Fixed Address Type Automatic Tool Changer (고정번지식 ATC개발에 관한 연구)

  • 이춘만;허영진
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1015-1018
    • /
    • 2002
  • Recently, many studies have been undergoing to reduce a working time in a field of machine tool. There are two ways of reducing a working time; to reduce an actual working time by heighten a speed of spindle and to reduce a stand-by time by shortening a tool exchanging time. ATC(Automatic Tool changer) belongs to the latter case. Fixed address type ATC that is being developed ill this study can store more number of tool in small space than magazine transfer type ATC relatively as well as shorten tool exchanging time. In this study, a simplified equivalent model of finite element method in order to analyze structure of fixed address type ATC.

  • PDF

A Study on The Assessment Method of Gait Analysis for Ankle Assembly Using Ground Reaction Force (지면반발력을 이용한 인공족관절의 보행평가 기법에 관한 연구)

  • Kim Sung Min;Kim Sung Jae;Bae Ha Suk;Choi Byoung Cheol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.5 s.170
    • /
    • pp.197-204
    • /
    • 2005
  • In this study, ground reaction force(GRF), absolute symmetry index(ASI) and coefficient of variation(CV) of fixed, single-axis and multi-axis prosthetic ankle assemblies were investigated to show the biomechanical evaluation for above knee amputees. In the experiments, 37 normal male volunteers, two male and two female AK amputees were tested with fixed, single-axis and multi-axis prosthetic ankle assembly. A gait analysis was carried out to derive the ratio of GRF to weight as the percentage of total stance phase for ten points. The results showed that fixed-axis ankle was superior to the other two ankle assemblies for the characteristic of forwarding and breaking forces. Multi-axis ankle was relatively superior to the other two ankle assemblies for gait balancing and movement of the center for mass. single-axis ankle was relatively superior to the other two ankle assemblies for CV and ASI of GRF.

A Note on Comparing Multistage Procedures for Fixed-Width Confidence Interval

  • Choi, Ki-Heon
    • Communications for Statistical Applications and Methods
    • /
    • v.15 no.5
    • /
    • pp.643-653
    • /
    • 2008
  • Application of the bootstrap to problems in multistage inference procedures are discussed in normal and other related models. After a general introduction to these procedures, here we explore in multistage fixed precision inference in models. We present numerical comparisons of these procedures based on bootstrap critical points for small and moderate sample sizes obtained via extensive sets of simulated experiments. It is expected that the procedure based on bootstrap leads to better results.

AN ITERATIVE METHOD FOR SOLVING EQUILIBRIUM PROBLEM FIXED POINT PROBLEM AND GENERALIZED VARIATIONAL INEQUALITIES PROBLEM

  • Zhang, Lijuan;Li, Juchun
    • East Asian mathematical journal
    • /
    • v.27 no.5
    • /
    • pp.527-538
    • /
    • 2011
  • In this paper, we introduce a new iterative scheme for finding a common element of the set of an equilibrium problem, the set of fixed points of nonexpansive mapping and the set of solutions of the generalized variational inequality for ${\alpha}$-inverse strongly g-monotone mapping in a Hilbert space. Under suitable conditions, strong convergence theorems for approximating a common element of the above three sets are obtained.