• 제목/요약/키워드: fixed plate

검색결과 487건 처리시간 0.025초

초기 횡방향 유동이 존재하는 충돌제트/유출냉각에서 요철이 설치된 유출면에서의 열/물질전달 특성 (Heat/Mass Transfer Characteristics on Rib-roughened Surface for Impingement/Effusion Cooling System with Initial Crossflow)

  • 이동호;남용우;조형희
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.338-348
    • /
    • 2004
  • The present study is conducted to investigate the effect of rib arrangements on an impingement/effusion cooling system with initial crossflow. To simulate the impingement/effusion cooling system, two perforated plates are placed in parallel and staggered arrangements with a gap distance of 2 times of tile hole diameter. Initial crossflow passes between the injection and effusion plates, and the square ribs (3mm) are installed on the effusion plate. Both the injection and effusion hole diameters are 10mmand Reynolds number based on the hole diameter and hole-to-hole pitch are fixed to 10,000 and 6 times of the hole diameter, respectively. To investigate the effects of rib arrangements, various rib arrangements, such as 90$^{\circ}$transverse and 45$^{\circ}$angled rib arrangements, are used. Also, the effects of flow rate ratio of crossflow to impinging jets are investigated. With the initial crossflow, locally low transfer regions are formed because the wall jets are swept away, and level of heat transfer rate get decreased with increasing flow rate of crossflow. When the ribs are installed on the effusion plate, the local distributions of heat/mass transfer coefficients around the effusion holes are changed. The local heat/mass transfer around the stagnation regions and the effusion holes are affected by the rib positions, angle of attack and rib spacing. For low blowing ratio, the ribs have adverse effects on heat/mass transfer, but for higher blowing ratios, higher and more uniform heat transfer coefficient distributions are obtained than the case without ribs because the ribs prevent the wall jets from being swept away by the crossflow and increase local turbulence of the flow near the surface. Average heat transfer coefficients with rib turbulators are approximately 10% higher than that without ribs, and the higher values are obtained with small pitch of ribs. However, the attack angle of the rib has little influence on the average heat/mass transfer.

인간 치주인대 유래 섬유모세포에 대한 흡수성 교원질 차폐막의 생체적합성 (BIOCOMPATIBILITY OF ABSORBABLE COLLAGEN MEMBRANES IN HUMAN PDL-DERIVED FIBROBLASTS IN VITRO)

  • 권용대;이백수;주성숙
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제32권3호
    • /
    • pp.272-278
    • /
    • 2006
  • Purpose: This study is designed to evaluate biocompatibility of three types of absorbable collagen GBR membrane in vitro. Material and Method: The human PDL fibroblasts culture was obtained through typical way and the cells used in the experiment was forth passage. The membranes examined were Experimental group A, B, C. All the 3-experimental groups were made of bovine pericardium and the membranes were excised into 5$\times$5mm respectively. The samples of the membranes were fixed on the 24-well plate with the double-sided adhesive tape. Then, 2ml of cell suspension which included $2{\times}10^4$cells was inoculated into the 24-well plate, and the cells were cultured for 1 week. Cellular viability and the alkaline phosphatase activity were measured with ELISA. The membranes in the culture were processed to examine with SEM. Results: The survival rate was highest in control and Experimental group A is the next, group B and group C in order of the value. The values are analyzed for statistical difference using Wilcoxon test. All the values of experimental groups are significantly lower than those of control, and the vaules among the experimental groups significantly differ from each other. Alkaline phosphatase level was identical order with the viable cell rate. SEM examination revealed that the PDL fibroblasts adherent on culture dish (control) and group A were spindle-shaped, but on group B and C, the cells were round-shaped without processes.

반발식 동전기 휠을 이용한 비접촉 반송 시스템의 변수 설계 (Parametric Design of Contact-Free Transportation System Using The Repulsive Electrodynamic Wheels)

  • 정광석
    • 한국산학기술학회논문지
    • /
    • 제17권3호
    • /
    • pp.310-316
    • /
    • 2016
  • 도전성 평판에 부분적으로 걸쳐 회전하는 축형 동전기 휠을 구동원으로 이용하는 비접촉 반송 시스템을 제안한다. 회전하는 동전기 휠에는 3축력이 발생되는데 이 중 중력방향 힘과 횡방향 힘은 자기안정성을 갖고 있으므로 공간상에서 반송 시스템의 동적 안정성을 확보하기 위해서는 길이 방향 힘만을 제어하는 것으로 충분하다. 동전기 휠은 원주 방향을 따라 주기적으로 반복되는 극성을 갖는 영구자석으로 구성되어있으므로 기본 극의 기하학적 형상이나 극수 등은 안정성 여유에 큰 영향을 미친다. 또한 휠과 전도판간의 중첩된 영역 역시 횡방향으로의 강성을 결정하는 주요 인자이므로 본 논문에서는 안정성을 성능 지표로 휠을 구성하는 주요 설계 변수에 대한 민감도 해석을 수행한다. 얻어진 설계 값을 이용하여 제작된 시스템으로 휠을 포함하는 이동 개체의 수동적인 안정성을 실험적으로 검증한다.

Effect of Distribution System Materials and Water Quality on Heterotrophic Plate Counts and Biofilm Proliferation

  • 장영철;정권
    • Journal of Microbiology and Biotechnology
    • /
    • 제14권6호
    • /
    • pp.1114-1119
    • /
    • 2004
  • The biofilms on pipe walls in water distribution systems are of interest since they can lead to chlorine demand, coliform growth, pipe corrosion, and water taste and odor problems. As such, the study described in this paper is part of an AWWARF and Tampa Bay Water tailored collaboration project to determine the effect of blending different source waters on the water quality in various distribution systems. The project was based on 18 independent pilot distribution systems (PDS), each being fed by a different water blend (7 finished waters blended in different proportions). The source waters compared were groundwater, surface water, and brackish water, which were treated in a variety of pilot distribution systems, including reverse osmosis (RO) (desalination), both membrane and chemical softening, and ozonation-biological activated carbon (BAC), resulting in a total of 7 different finished waters. The observations from this study consistently demonstrated that unlined ductile iron was more heavily colonized by a biomass than galvanized steel, lined ductile iron, and PVC (in that order) and that the fixed biomass accumulation was more influenced by the nature of the supporting material than by the water quality (including the secondary residual levels). However, although the bulk liquid water cultivable bacterial counts (i.e. heterotrophic plate counts or HPCs) did not increase with a greater biofilm accumulation, the results also suggested that high HPCs corresponded to a low disinfectant residual more than a high biofilm inventory. Furthermore, temperature was found to affect the biofilms, plus the AOC was important when the residual was between 0.6 and 2.0 mg $Cl_2/l$. An additional aspect of the current study was that the potential of the exoproteolytic activity (PEPA) technique was used along with a traditional so-called destructive technique in which the biofilm was scrapped off the coupon surface, resuspended, and cultivated on an R2A agar. Both techniques indicated similar trends and relative comparisons among the PDSs, yet the culturable biofilm values for the traditional method were several orders of magnitude lower than the PEPA values.

새로운 방식의 나사형 인공디스크 고정체 해석 (Finite Element Analysis of a Newly Designed Screw Type Fixture for an Artificial Intervertebral Disc)

  • 임종완;양현익
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권1호
    • /
    • pp.56-66
    • /
    • 2010
  • The various total replacement artificial discs have developed because spinal fusion has shown a lesser mobility of an operated segment and an accelerated degeneration at adjacent discs. But almost artificial discs have not yet been reached on the substitute surgery of fusion because many problems such as those clinical success rates were not more than them of fusion have not solved. In this paper, vertically inserted assemble-screw fixture in vertebrae was proposed to improve the fixed capability of artificial disc. And also, to evaluate the design suitability of newly designed screw-type, including fixtures of commercial discs such as wedge and plate type, the 1/4 finite element model with a vertebra and various implanted fixtures were generated, and next, 3 bending motions such as flexion, bending and twisting under the moment of 10Nm and compression under the force of 1000N were considered, respectively and finally, FE analyses were performed. Results of three fixture types were compared, such as Range of Motion and maximal stress, and so on. For ROM, the screw type was average 58% less than the wedge type and was average 42% less than the plate type under all loading conditions. For average stress ratio at closer nodes between vertebra and each fixture, the wedge type was the lowest as minimum 0.02 in twisting, screw types were the highest as maximum 0.28 in compression. As the results of using cement material, it was predicted that the instability problem of the wedge type was better solved. The screw type which could be increased by implanting depth according to the number of assembling mid screws, showed that the decreased tendency of ROMs and maximal cancellous bone stresses. In further study, controlling the number of assembling screws that was suitable for a patient's bone quality, development of surgical tools and keeping on design supplementations, which will be able to develop the competitive artificial disc.

Mandible Reconstruction with 3D Virtual Planning

  • Woo, Taeyong;Kraeima, Joep;Kim, Yong Oock;Kim, Young Seok;Roh, Tai Suk;Lew, Dae Hyun;Yun, In Sik
    • Journal of International Society for Simulation Surgery
    • /
    • 제2권2호
    • /
    • pp.90-93
    • /
    • 2015
  • The fibula free flap has now become the most reliable and frequently used option for mandible reconstruction. Recently, three dimensional images and printing technologies are applied to mandibular reconstruction. We introduce our recent experience of mandibular reconstruction using three dimensionally planned fibula free flap in a patient with gunshot injury. The defect was virtually reconstructed with three-dimensional image. Because bone fragments are dislocated from original position, relocation was necessary. Fragments are virtually relocated to original position using mirror image of unaffected right side of the mandible. A medical rapid prototyping (MRP) model and cutting guide was made with 3D printer. Titanium reconstruction plate was adapted to the MRP model manually. 7 cm-sized fibula bone flap was designed on left lower leg. After dissection, proximal and distal margin of fibula flap was osteotomized by using three dimensional cutting guide. Segmentation was also done as planned. The fibula bone flap was attached to the inner side of the prebent reconstruction plate and fixed with screws. Postoperative evaluation was done by comparison between preoperative planning and surgical outcome. Although dislocated condyle is still not in ideal position, we can see that reconstruction was done as planned.

Vascularized Bipedicled Pericranial Flaps for Reconstruction of Chronic Scalp Ulcer Occurring after Cranioplasty

  • Yoon, Seok Ho;Burm, Jin Sik;Yang, Won Yong;Kang, Sang Yoon
    • Archives of Plastic Surgery
    • /
    • 제40권4호
    • /
    • pp.341-347
    • /
    • 2013
  • Background Intractable chronic scalp ulcers with cranial bone exposure can occur along the incision after cranioplasty, posing challenges for clinicians. They occur as a result of severe scarring, poor blood circulation of the scalp, and focal osteomyelitis. We successfully repaired these scalp ulcers using a vascularized bipedicled pericranial flap after complete debridement. Methods Six patients who underwent cranioplasty had chronic ulcers where the cranial bone, with or without the metal plate, was exposed along the incision line. After completely excising the ulcer and the adjacent scar tissue, subgaleal dissection was performed. We removed the osteomyelitic calvarial bone, the exposed metal plate, and granulation tissue. A bipedicled pericranial flap was elevated to cover the defect between the bone graft or prosthesis and the normal cranial bone. It was transposed to the defect site and fixed using an absorbable suture. Scalp flaps were bilaterally advanced after relaxation incisions on the galea, and were closed without tension. Results All the surgical wounds were completely healed with an improved aesthetic outcome, and there were no notable complications during a mean follow-up period of seven months. Conclusions A bipedicled pericranial flap is vascularized, prompting wound healing without donor site morbidity. This may be an effective modality for treating chronic scalp ulcer accompanied by the exposure of the cranial bone after cranioplasty.

난류 모형에 따른 수직 평판 위 파동 액막류의 수치해석 연구 (Numerical Study of Wavy Film Flow on Vertical Plate Using Different Turbulent Models)

  • 민준기;박일석
    • 대한기계학회논문집B
    • /
    • 제38권5호
    • /
    • pp.373-380
    • /
    • 2014
  • 액막류는 다양한 산업분야에 적용되는 쉘-튜브 열교환기의 주요 열교환기구로 오랫동안 연구되어왔다. 액막류의 한쪽 경계는 고정벽에 접하고 있지만 반대편에서는 기체 영역과 경계를 형성하므로 액막 레이놀즈 수가 증가함에 따라 쉽게 불안정해지는 특징을 가지고 있다. 따라서 레이놀즈 수가 증가함에 따라 자유표면 파동 현상이 나타나는데, 층류 영역에서는 큰 진폭의 고립파가, 난류 천이 이후에는 낮은 진폭의 물결파가 나타난다. 액막류의 열전달 성능은 액막의 두께에 의해 크게 지배받는데 액막류에 동반된 파동은 액막 두께의 시공간적 변화를 의미하는 것이므로 이에 대한 정보를 해석적으로 수집하는 것은 액막류 열전달 성능을 예측하는데 필수적이다. 본 연구에서는 낮은 진폭의 물결파를 동반한 난류 액막류에 대하여 여러 가지 난류 모형을 적용한 해석결과들을 실험결과와 비교함으로써 난류 모형들에 대한 평가를 실시하였다.

모래다짐말뚝과 널말뚝으로 처리된 연약점토지반의 거동 (Behavior of Soft Ground Treated with Sand Compaction Piles and Sheet Piles)

  • 유남재;정길수;박병수;김경수
    • 산업기술연구
    • /
    • 제26권B호
    • /
    • pp.93-99
    • /
    • 2006
  • Centrifuge model experiments were performed to investigate the confining effects of the sheet piles, installed to the sides of soft clay ground treated with sand compaction piles, on the bearing capacity and concentration ratio of composite ground. For the given g-level in the centrifuge model tests, replacement ratio of SCP and the width of surcharge loads on the surface of ground with SCP, the confining effects of installing the sheet piles on the edges of SCP ground on the bearing capacity, change of stress concentration ratio and failure mechanism were investigated. Kaolin, one of typical clay mineral, and Jumunjin standard sand were used as a soft clay ground and sand compaction pile irrespectively. As results of experiments, lateral confining effect by inserting the model sheet piles fixed to the loading plate was observed. For the strip surcharge loading condition, the yielding stress intensity in the form of the strip surcharge loads tends to increase with increasing the embedded depth of sheet piles. The stress concentration ratio was found not to be influenced consistently with the embedded depth of sheet piles whereas the effect of stress intensity on stress concentration ratio shows the general trend that values of stress concentration ratio are relatively high at the initial stage of loading and tend to decrease and converge to the certain values. For the failure mechanism in the case of reinforced with sheet piles, displacement behavior related to the punching failure, settlement right beneath the loading plate occurred since the soil was confined with sheet piles, was observed.

  • PDF

리브를 가진 장섬유 복합재료 커버 플레이트의 최적설계 (Optimal Design of Long-fiber Composite Cover Plate with Ribs)

  • 한민구;배지훈;이성우;장승환
    • Composites Research
    • /
    • 제30권1호
    • /
    • pp.65-70
    • /
    • 2017
  • 일방향 탄소섬유 복합재료는 복잡한 성형 공정과 낮은 드레이핑능을 보여 비교적 단순한 형태의 구조물 제작에 제한적으로 사용되어 왔으나, 최근 이를 해결하고자 성형성과 생산효율이 우수한 장섬유 복합재료(Long Fiber Prepreg Sheet; LFPS)가 제안되었다. 본 연구에서는 단순한 성형 공정과 높은 성형 정밀도를 갖는 LFPS를 활용하여 전자 기기용 커버 플레이트 설계를 수행하였다. 설계에 앞서 리브 구조가 적용되는 대상 구조물을 8-inch 태블릿 PC 제품의 뒷 커버로 선정하였다. 해당 구조물에 평판에 적용되는 대표적인 하중 조건을 선정하여 유한요소해석에 적용하였고, 이를 활용하여 리브 구조물의 패턴과 리브 형상 변화에 따른 구조물의 구조 강성을 확인하였다. 해석 결과 제한된 부피 내에서 최적의 리브 패턴과 형상을 확보하였으며, 리브 폭이 균일하지 않은 경우가 균일한 경우에 비해 6~10% 처짐량이 감소함을 확인하였다.