• Title/Summary/Keyword: fixation device

Search Result 91, Processing Time 0.022 seconds

Clinical Results of Anterior Cruciate Ligament Reconstruction Using Hamstring Tendon (슬괵건을 이용한 전방십자인대 재건술의 임상적 결과)

  • Song Eun Kyoo;Lee Keun Bae;Shin Sang Gyoo;Kim Hyun Jong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.1
    • /
    • pp.21-25
    • /
    • 2002
  • Purpose: To evaluate the clinical results after anterior cruciate ligament (ACL) reconstruction with hamstring tendon and Ligament Anchor (LA) screw, which is newly designed for fixation of graft into femur. Materials and Methods: Fifty eight patients who were followed up at least more than 2 years after ACL reconstruction with four strands of Hamstring tendon and LA screw were included in this study. The graft was fixed with LA screw at femoral tunnel and with only bioabsorbable interference screw at tibial tunnel. The mean follow-up period was 28 months. The clinical results were evaluated by physical examination and Lysholm knee score. Widening of bony tunnel and anterior laxity difference compared with normal side by instrumented anterior laxity test with Telos(R) (Telos stress device; Austin & Associates, Inc., Polston, US) were evaluated. Results: The Lysholm knee score improved from 60.0 points preoperatively to 94.0 points at last follow up. On the Lachman test, there were mild (+) instability in 16 cases, moderate (++) in 24,severe (+++) in 18 preoperatively. 50 cases were converted to negative and 8 to mild instability at postoperative follow up. On instrumented anterior laxity test with Telos(R), difference between normal and affected knee on 20 lb was 12.9 mm in average preoperatively, and was decreased to 3.1mm at last follow-up. The femoral tunnel was widened from 10.6 mm postoperatively to 12.7 mm (21.1$\%$) at follow up on antero-posterior plane and from 10.7 mm to 12.4 mm (16.5$\%$) on lateral plane. Tibial tunnels was also widened from 9.8mm to 11.8mm (20.7$\%$) on antero-posterior plane and from 9.9mm to 11.7 mm ($18.9\%$) on lateral plane. Complications were: anterior knee crepitus in 17 case, quadriceps muscle atrophy(>3 cm) in 6, penetration of screw over the lateral femoral cortex in 5, saphenous nerve paresthesia in 2.Conclusions: ACL reconstruction with hamstring tendon and LA screw was one of the choice of grafts and fixation devices in restoring knee stability and in improving clinical results with little complications such as excessive widening of bony tunnel and anterior knee pain

  • PDF

An Objective Evaluation on Menopausal Syndrome and the Effect of Red Ginseng

  • Katsutaro Nagata;Katsuya Morishita;Kotaro Fujioka;Misako Yamazaki;Akihiro Okamoto;Kenji Kubota
    • Proceedings of the Ginseng society Conference
    • /
    • 1998.06a
    • /
    • pp.322-326
    • /
    • 1998
  • In order to evaluate menopausal syndrome objectively, examinations were performed as follows: 1) Simplified Menopausal Index (SMI Koyama) and QOL questionnaire (Nagata) were examined subjectively. 2) Urine 17-KS-5 (S Nishikaze), 17-OHCS (OH) were examined objectively. 3) A mobile telemedical device with EKG and KSG was lent to Patients. The subjects were 48 menopausal patients who visited our university hospital as outpatients. According to the results of 5, OH, the subjects were divided into 4 Groups; Group I is high S & high OH, Group ll low S & low OH, Group 111 is low S & high OH, Group tl is high S & low OH. Group IH was the largest (64.6%), Group of was none. The subjects showed significantly lower QOL condition and higher score of SMI. In the QOL, questionnaire items of fixation to physical status (psychogenic reaction), sleep (insomnia), pain(chronic pain) were in common. In SMI, functional vascular symptoms were the largest number. On treatment, Group I was considered to have no need for supplementary agents, but anti-Oketsu agents was prescribed. For Group ll and in some supplementary agents such as red ginseng were prescribed, because they showed low 5. In conclusion, all the groups showed a sign- nificant improvement of QOL and SMI. Group I showed a decrease of OH, Group ll showed an increase of 5, Group In showed an increase of S and SIOH and a decrease of OH. These phenomena were considered prohomeostatic. In QOL, the items of chronic pain, insomnia and appetite were improved. In SMI, chillness, dyspnea, palpitation, pain and fatigability were improved. In mobile tole-medical device, abnormal findings were found in 88.2% of patients. General sdaptation syndrome (Selye, H.) is considered to adjust human life. Menopause is the transit period to exhausted stage in it. So its symptoms vary from person to person. In conclusion, 5 and OH are useful both for classification of menopausal syndrome and for determining treatments according to the classification

  • PDF

CLINICAL STUDY OF SENSORY ALTERATIONS AFTER SAGITTAL SPLIT RAMUS OSTEOTOMY (하악지 시상분할 절단술 후 감각 변화에 관한 연구)

  • Choi, Jun-Young;Yoo, Jun-Yeol;Yoon, Bo-Keun;Leem, Dae-Ho;Shin, Hyo-Keun;Ko, Seung-O
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.2
    • /
    • pp.141-148
    • /
    • 2010
  • The bilateral sagittal split ramus osteotomy (BSSRO) is preferred method of surgical correction for mandibular prognathism, retrognathism and asymmetry. This technique performed from primarily an intraoral incision to avoid a scar. After forward movement of the distal segment of the mandible, healing of bone by primary or secondary intention is easily accomplished through large areas of cancellous bony overlap. When rigid fixation is used for the BSSRO, it is possible to open the mouth during the immediate post-operative period because it promotes the healing process. Although this surgical procedure has been well-documented, the incidence of postoperative trigeminal neurosensory disorder in the region of the inferior alveolar nerve and the mental nerve remains one of the major complication. However, evaluation of objective methods for sensory recovery patterns is insufficient although most patients find their sensory return. Neurometer electrodiagnostic device performs automated neuroselective sensory nerve conduction threshold evaluation by determining current perception threshold (CPT) measures. The purpose of this study was to evaluate the sensory recovery patterns of inferior alveolar and mental nerve over time. Nerve examination with a neurometer was performed in 30 patients undergoing the BSSRO at pre-operative, post-operative 1-, 2-, 4- week, and 2-, 3-, 4-, 5-, 6- month follow-up visits after the osteotomy to compare the differences of nerve injury and recovery patterns after the BSSRO with or without genioplasty and sensory recovery patterns associated with the kind of nerve fiber.

Evaluation of Setup When Using C-Rad System in Radiotherapy (방사선치료 시 C-Rad system을 이용한 셋업의 평가)

  • Park, Eun-Tae;Ko, Seong-Jin;Choi, Seok-Yoon;Kim, Jung-Hoon;Kim, Chang-Soo;Kim, Dong-Hyun;Kang, Se-Sik
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.5
    • /
    • pp.303-310
    • /
    • 2012
  • In radiotherapy, accurate patient positioning and set up are important factor that treatment can influence success. In generally, the 3-laser system is used when the patient set up. But today the body surface scanning system(C-Rad system) is trying to use. Compare and evaluate the C-Rad system and the 3-laser system to check availability. Head and neck that are no movement of internal organs and easy to apply fixation device are limited. Alderson Rando anthropomorphic phantom and 10 patients who have lesions of head and neck are targeted. C-RAD system's setup error mean and standard deviation are the X axis($0.55{\pm}0.51mm$), Y axis($-0.2mm{\pm}0.523mm$), Z axis($-0.85{\pm}0.587mm$) in the phantom study, and in the patient study X axis($-0.05{\pm}0.621mm$), Y axis($0.075{\pm}0.755mm$) Z axis($-1.025{\pm}0.617mm$). So C-RAD system is better than 3-laser system mostly, but C-RAD system's error rate is a little worse than 3-laser system in the Z axis. When radiation treatment of head and neck, body surface contour scanning system contribute to correct positioning and minimize the set up error.

An Experimental Study on the Biomechanical Effectiveness of Bone Cement-Augmented Pedicle Screw Fixation with Various Types of Fenestrations

  • Yoon, Sang Hoon;Lee, Sang Hyung;Jahng, Tae-Ahn
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.6
    • /
    • pp.779-789
    • /
    • 2022
  • Objective : To analyze the effects of the number and shape of fenestrations on the mechanical strength of pedicle screws and the effects of bone cement augmentation (BCA) on the pull-out strength (POS) of screws used in conventional BCA. Methods : For the control group, a conventional screw was defined as C1, a screw with cannulated end-holes was defined as C2, a C2 screw with six pinholes was defined as C3, and the control group type was set. Among the experimental screws, T1 was designed using symmetrically placed thru-hole type fenestrations with an elliptical shape, while T2 was designed with half-moon (HM)-shaped asymmetrical fenestrations. T3 and T4 were designed with single HM-shaped fenestrations covering three pitches and five pitches, respectively. T5 and T6 were designed with 0.6-mm and 1-mm wider fenestrations than T3. BCA was performed by injecting 3 mL of commercial bone cement in the screw, and mechanical strength and POS tests were performed according to ASTM F1717 and ASTM F543 standards. Synthetic bone (model #1522-505) made of polyurethane foam was used as a model of osteoporotic bone, and radiographic examinations were performed using computed tomography and fluoroscopy. Results : In the fatigue test, at 75% ultimate load, fractures occurred 7781 and 9189 times; at 50%, they occurred 36122 and 82067 times; and at 25%, no fractures occurred. The mean ultimate load for each screw type was 219.1±52.39 N for T1, 234.74±15.9 N for T2, 220.70±59.23 N for T3, 216.45±32.4 N for T4, 181.55±54.78 N for T5, and 216.47±29.25 N for T6. In comparison with C1, T1, T2, T3, T4, and T6 showed significantly different ultimate load values (p<0.05). However, when the values for C2 and the fenestrated screws were evaluated with an unpaired t test, the ultimate load value of C2 significantly differed only from that of T2 (p=0.025). The ultimate load value of C3 differed significantly from those of T1 and T2 (C3 vs. T1 : p=0.048; C3 vs. T2 : p<0.001). Linear correlation analysis revealed a significant correlation between the fenestration area and the volume of bone cement (Pearson's correlation coefficient r=0.288, p=0.036). The bone cement volume and ultimate load significantly correlated with each other in linear correlation analysis (r=0.403, p=0.003). Conclusion : Fenestration yielded a superior ultimate load in comparison with standard BCA using a conventional screw. In T2 screws with asymmetrical two-way fenestrations showed the maximal increase in ultimate load. The fenestrated screws can be expected to show a stable position for the formation of the cement mass.

Widening of Bony Tunnel after ACL Reconstruction Using Hamstring Tendon with Ligament Anchor(LA) Screw (슬괵건 및 LA나사를 이용한 관절경적 전방 십자 인대 재건술 후 골터널의 확장)

  • Song Eun Kyoo;Yoon Taek Rim;Jung Jong Wook;Jeong Kwang Cheul
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.2
    • /
    • pp.69-73
    • /
    • 2001
  • Purpose : To evaluate the clinical results and widening of bony tunnel after anterior cruciate ligament(ACL) reconstruction using hamstring tendon with Ligament Anchor(LA) screw, which is newly designed fur fixation of graft into femur. Materials and Methods : Fifty eight patients who were followed up at least more than 2 years after ACL reconstruction with four strands of Hamstring tendon were included in this study. The graft was fixed with LA screw at femoral tunnel and with bioabsorbable interference screw at tibial tunnel. The average period of follow-up was 28 months. The clinical results such as physical examination and Lysholm knee score and radiological results. widening of bony tunnel and instrumented anterior laxity test with $Telos^{\circledR}$(Telos stress device; Austin & Associates, Inc., Polston, US) were evaluated. Results . The Lysholm knee score was 60.0 in average preoperatively and improved to 94.0 in average at follow up. On the Lachman test, there were mild(+) instability in 16 cases, moderate(++) in 24, severe(+++) in 18 preoperatively. 50 cases were converted to negative and 8 to mild instability at follow up. On instrumented anterior laxity test with $Telos^{\circledR}$, side to side difference in 20 lb was 12.9mm in average preoperatively, and was decreased to 3.1mm in average follow-up. The femoral tunnel was widened from 10.6mm postoperatively to 12.7mm$(21.1\%)$ at follow up on antero-posterior plane and from 10.7mm to 12.4mm$(16.5\%)$ on lateral plane. Tibial tunnels was also widened from 9.8mm to 11.8mm$(20.7\%)$ on antero-posterior plane and from 9.9mm to 11.7mm$(18.9\%)$ in lateral plane. Conclusion : ACL reconstruction with hamstring tendon and LA screw was one of the choice of grafts and fixatives in restoring knee stability and in improving clinical results with little complications such as excessive widening of bony tunnel.

  • PDF

EXPRESSION OF PROLIFERATING CELL NUCLEAR ANTIGEN AND TYPE I COLLAGEN IN THE ELONGATED BONE IN THE MANDIBLE OF ADULT MONGREL DOGS (성견 하악 골체부 신장시 신장부위의 증식세포핵항원과 제 1형 교원질 발현에 관한 연구)

  • Lim, Sun-Mo;Ahn, Byoung-Keun;Park, Young-Ju;Park, Hee-Geon;Park, Jun-Woo;Rhee, Gun-Joo;Lee, Yong-Chan;Cho, Byoung-Ouck
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.5
    • /
    • pp.385-396
    • /
    • 2001
  • The purpose of this experiment was to examine the histological changes and the pattern of expression of proliferating cell nuclear antigen(PCNA) and type I collagen in the elongated bone affected by osteodistraction of the mandibular body in an adult canine model. Seven adult male mongrel dogs weighing over 20kg were used for this experiment. The author excluded 3 animals because they died before the planned time of sacrifice. The custom-made linear extraoral device and 4 bicortical fixation screws 2.3mm in diameter, 50mm in total length, 15mm in screw length were used in each animal. The distal part of the distractor produced a 0.75mm gap between proximal and distal bony segments every $360^{\circ}$ turn of the rotation rod of the device. The mandibular body of the right side from each animal was experimental side and the left side was left intact and served as control. At the experimental side, the mandibular body was osteotomized. After 5-day latency period, the segments were distracted with a rate of 1.1mm/day and a rhythm of two/day for ensuing 7 days. The animals were sacrificed at the 4th. 17th, and 32th day after the end of the distraction. The bony specimens were decalcified, embedded in paraffin, sectioned $5{\mu}m$ thick and stained with Masson trichrome and examined under the light microscope. The immunohistochemical examinations using anti-PCNA antibody and anti-type-I collagen antibody were performed to examine the pattern of the expression of PCNA and type I collagen, respectively. Results : 1. The mean increment of the distance between the proximal and distal screw-holding parts of the distractor was 6.8mm. The average elongation of the mandible in the experimental side was 5.3mm. The loss of elongation was 1.5mm in average. 2. New bone was already observed at the 4th. day after the end of distraction. But, bony union was not completed in the distraction gap at the 32th. day after the end of distraction by radiographic and microscopic examinations. 3. The expression rate of PCNA positive cells in the distraction gap had a tendency of decrease from 35.1-68.8% initially, to 49.1%, and finally to 17.6-27.2%. But at the final period, the tissue of the elongated gap still had the ability of cell proliferation. On the other hand, the expression of PCNA positive cells in the control side were negligible through the experimental period. 4. PCNA positive cells were observed primarily both at the central fibrous zone and at the region of just adjacent to CFZ which initiated new bone formation. 5. The expression pattern of the type I collagen was not zone-specific. They were observed diffusely throughout the elongation gap. 6. The predominant mechanism of new bone formation in the distraction gap was intramembranous. But, some of the regenerated bone was formed by endochondral ossification.

  • PDF

Histological Observation of Bone Reaction with Relation to Surface Treatment of Titanium (생체합금 Titanium의 표면처리에 따른 골반응의 변화에 대한 조직학적 관찰)

  • Ahn, Myun-Whan;Choi, Yong-Sug;Ahn, Jong-Chul;Seo, Jae-Sung;Lee, Dong-Chul;Jang, Jae-Hyuk
    • Journal of Yeungnam Medical Science
    • /
    • v.13 no.1
    • /
    • pp.116-133
    • /
    • 1996
  • The biocompatibility of the titanium has been estabilished through various experimental studies such as cell culture toxicity test, pyrogen test, mutagen test and others. In order to confirm biocompatibility after fabrication of titanium and to clarify the difference between the bone reaction after insertion of the lathed titanium rods and the bone reaction after insertion of the finished and polished rods, both rods were implanted into the proximal femur of a rabbit. Histologic reactions in the bone were observed according to the ASTM standards at the intervals of 6 weeks, 12 weeks and 26 weeks after implantation. The result were as follows : In 6 weeks after implantation of lathed titanium rods, inflammatory reactions, such as minimal degree infiltration of polymorphonuclear leukocytes and lymphocytes were observed in all cases. This was thought to he caused by surgical trauma. However, inflammatory cell infiltration was not seen after implantation of polished and finished rods in all cases. The cellular infiltration and the histologic reaction of the hone after implantation of lathed group were significantly more pronounced than those after implantation of the finished group. In 12 weeks after implantation of lathed rods, two of four cases revealed a minimal degree of cellular infiltration. No inflammatory cell infiltration was demonstrated after implantation of the finished group. The cellular infiltration and histologic reaction seemed to be more pronounced in the lathed group, but they were not significant statistically. At 26 weeks after implantation of the lathed and finished group, there was no cellular infiltration in both groups. New bone formation was observed up 26 weeks, and no difference between lathed titanium rods and finished titanium rods were apparent. Mild bone necrosis was observed in 1 case out of 11 cases in which lathed titanium rods were implanted. Bone necrosis was not observed in the finished titanium rod group. Fibrosis was observed in both groups, but differences were not significant between the experimental groups. In the lathed titanium rods group and the shorter interval group, inflammatory cell infiltration was significantly higher. Finished titanium rods and longer interval groups had markedly decreased tendences in histologic reaction ratings. As a conclusion, although certificated titanium might be safe to use, difference of biocompatibility were observed depending on the method of surface finish. By identifying biocompatibility as a long-term standardized animal study, we can develop progressed internal fixation device that is safe for human beings.

  • PDF

Effect of the magnetism(neodymium magnet) on growth factor receptors of osteoblasts (희토류 자석의 자성이 골모세포 성장인자 수용체의 증가에 미치는 영향에 관한 연구)

  • Lee, Sang-Min;Lee, Sung-Bok;Choi, Boo-Byung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.2
    • /
    • pp.87-96
    • /
    • 2003
  • The purposes of this study were to find out the optimum intensity of magnetic field where magnetism could promote the activity of osteoblast, and to discover the possibility of clinical application in the areas of dental implants and bone grafts by confirming the effect of clinically increasing bone formation. In this experiment, we used the Neodymium magnet, which had magnetic power six times as strong as the current ones and enabled the resistances against the demagnetization up to 20 to 50 times to be minimized with the size of 1mm in sight. In order to culture cells, a specially designed device was used. It was made to adjust the distance and accordingly to control the intensity of the magnetic field, by placing the cell culture plate in the center with a magnet of 1mm long and thick installed on the both ends. Using MC3T3-E1 cell, a kind of osteoblast-like cell, we cultured, for 24 hours, not only the test group which had been cultured under the magnetic fields with different intensity of 5, 10, 50, 100, 500, and 1000 Gauss, but also the control group excluding the influences of the magnetic field. After observing the cell's form and the density of the culture medium through an inverted microscope, we made a series of proceedings needed for the immunofluoroscence staining, such as fixation, normal serum reaction, primary antibody reaction, and secondary antibody reaction. And with a fluorescence microscope, we observed those-above and compared the frequency of expression of IFG-1 receptor. To make a Western immunoblotting analysis, the cells cultured under the same condition as the above had the procedure of the lysis buffer and the acrylamide gel electrophoresis was carried out. Protein transferred into the nitrocellulose membrane and tested on the primary and the secondary antibody reactions was observed and compared. The results were as follows: When observed through an inverted microscope, the nuclear divisions of the cells under the magnetic field of 10 Gauss were the most active, and the density of the cells could be observed the most enormously. As the result of an immunofluoroscence staining of IGF-1 receptor, the expression of IFG-1 was the most frequently observed under the magnetic field of 10 Gauss. On the other hand, few differences of consideration were made between the test group cultured under the magnetic fields of 5, 500, and 1000 Gauss and the control group. In respect of the expression of IFG-1 receptor, the test group cultured under the magnetic fields of 50 and 100 Gauss were higher than the control group, and lower than that cultured under the magnetic field of 10 Gauss.(p<0.05) According to the Western immunoblotting analysis, the band of IFG-1 receptor which had 85KDa of molecular weight was the darkest. Judging from the above-mentioned results, the growth factor receptor of an osteoblast cell which was an important criterion for the bone formation was increased in maximum under the magnetic field of 10 Gauss. Moreover it was observed that the optimum intensity of magnetic field in which magnetism made the activity of the osteoblast cell increase was about 10 Gauss.

ACL reconstruction with autologous hamstring tendon - Short term clinical result using new femoral suspensory fixation device 'Cross Pin' and graft tensioner for maintaining a constant tension- (자가 슬괵건을 이용한 전방 십자 인대 재건술 - 새로운 대퇴부 현수고정법인 Cross Pin과 일정한 긴장력 유지를 위한 Graft Tensioner 사용의 단기 추시 결과 -)

  • Seo, Seung-Suk;Kim, Chang-Wan;Kim, Jin-Seok;Choi, Sang-Yeong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.1
    • /
    • pp.27-34
    • /
    • 2011
  • Purpose: To evaluate the short term clinical result of ACL reconstruction with autologous hamstring tendon using Cross pin and Graft Tensioner and to seek way to resolve the experienced technical problems. Materials and Methods: From January 2008 to March 2009, 35 patients who had been treated arthroscopic ACL reconstruction were enrolled. The femoral side of ACL graft was fixed with Cross pin. The tibial side of graft was fixed with Intrafix and post-tie. The graft was tensioned with Graft Tensioner at 80N. We analyzed the clinical, radiographic results and complications. Results: IKDC subjective score and Lysholm score improved to 89.1 and 91.4 points. Also, Pivot shift test and One-leg hop test showed good results postoperatively. Side to side difference using KT-1000 arthrometer and Telos stress radiography improved compared with normal limb to $2.8{\pm}1.6$ mm and $2.6{\pm}1.3$ mm, respectively. The femoral tunnel enlarged to $2.3{\pm}1.1$ mm. Soft tissue irritation and femoral tunnel-graft harness length mismatch, femoral tunnel-cross pin tunnel mismatch were happened as peri-operative complications. Conclusion: Using of Cross pin and Graft Tensioner for ACL reconstruction with hamstring tendon is one of the good method for obtaining stability in short-term clinical result. But to reduce femoral tunnel-cross pin mismatch, it needs to shorten femoral bone tunnel and to create cross pin tunnel as vertical as possible. And to reduce femoral tunnel-graft harness mismatch, it needs to advance position rod further 3 mm when to create femoral tunnel.

  • PDF