• 제목/요약/키워드: fixation

검색결과 2,807건 처리시간 0.026초

흉골 전위골절에 대한 수술적 정복고정술의 결과 (The Result of Open Reduction and Fixation in Sternal Fracture with Displacement)

  • 김영진;조현민
    • Journal of Trauma and Injury
    • /
    • 제23권2호
    • /
    • pp.175-179
    • /
    • 2010
  • Purpose: Sternal fractures after blunt thoracic trauma can cause significant pain and disability. They are relatively uncommon as a result of direct trauma to the sternum and open reduction is reserved for those with debilitating pain and fracture displacement. We reviewed consecutive 11 cases of open reduction and fixation of sternum and tried to find standard approach to the traumatic sternal fractures with severe displacement. Methods: From December 2008 to August 2010, the medical records of 11 patients who underwent surgical reduction and fixation of sternum for sternal fractures with severe displacement were reviewed. We investigated patients' characteristics, chest trauma, associated other injuries, type of open reduction and fixation, combined operations, preoerative ventilator support and postoperative complications. Results: The mean patient age was 59.3years (range, 41~79). The group comprised 6 male and 5 female subjects. Among 11 patients who underwent open reduction and fixation for sternal fracture with severe displacement, 6 cases had isolated sternal fractures and the other 5 patients had associated other injuries. Sternal fractures were caused by car accidents (9/11, 81.8%), falling down (1/11, 9.1%) and direct blunt trauma to the sternum (1/11, 9.1%), respectively. 3 of the 7 patients (42.9%) who underwent sternal plating with longitudinal plates showed loosening of fixation. Otherwise, none of the 4 patients who underwent surgical fixation using T-shaped plate had stable alignment of the fracture. Conclusion: Sternal fractures with severe displacement need to be repaired to prevent chronic pain, instability of the anterior chest wall, deformity of the sternum, and even kyphosis. In the present study, a T-shaped plate with a compression-tension mechanism constitutes the treatment of choice for displaced sternal fractures.

Clinical and Structural Outcomes of Arthroscopic Intraarticular Knotless Fixation for Upper Subscapularis Tendon Tears: A Preliminary Report

  • Cho, Nam Su;Shim, Hee Seok;Nam, Ju Hyun;Rhee, Yong Girl
    • Clinics in Shoulder and Elbow
    • /
    • 제19권3호
    • /
    • pp.130-136
    • /
    • 2016
  • Background: A novel technique for the repair of tears of the upper subscapularis tendon-intraarticular knotless fixation-has been introduced recently. The purpose of this study was to evaluate the clinical and structural outcomes of arthroscopic intraarticular knotless fixation for the treatment of upper subscapularis tendon tears. Methods: We retrospectively analyzed the clinical and radiological outcomes of 27 patients who underwent arthroscopic intraarticular knotless fixation for upper subscapularis tendon tears. Finally, a total of 10 patients who could participate in at least a 6 month follow-up of magnetic resonance imaging evaluation and in a least 1-year follow-up on an outpatient basis were enrolled in our study. The mean age at the time of operation was 60.7 years, and the mean duration of follow-up was 14.7 months. Two patients had concomitant tears of the supraspinatus tendon and 8 patients had concomitant tears of the supraspinatus and the infraspinatus tendons. Results: The clinical and radiological outcomes improved after the patients had undertaken arthroscopic intraarticular knotless fixation. The mean visual analogue scale score for pain during motion improved from 6.7 preoperatively to 1.4 at the final follow-up (p<0.001). The mean Constant score improved from 59.3 preoperatively to 79.6 at the final follow-up, and the mean the University of California at Los Angeles score, from 21.7 to 30.2, respectively (p<0.001 and p<0.001). The upper subscapularis tendon tear was healed in every patient except one (90%), for the patient had suffered from a postoperative trauma that resulted in a retear. Conclusions: We found that arthroscopic intraarticular knotless fixation gives good clinical and structural outcomes for the repair of upper subscapularis tendon tears. Arthroscopic intraarticular knotless fixation provided such a reliable and efficient restoration of the subscapularis tendon footprint that we anticipate it will become a widely-used procedure for upper subscapularis tendon tears.

Treatment of Acute Acromioclavicular Joint Dislocation: Kirschner's Wire Trans-acromial Fixation versus AO Locking Hook Plate Fixation

  • Kim, Young-Jun;Chun, Yong-Min
    • Clinics in Shoulder and Elbow
    • /
    • 제19권3호
    • /
    • pp.149-154
    • /
    • 2016
  • Background: The purpose of this study is to compare clinical and radiological outcomes between trans-acromial fixation with Kirschner's wire (K-wire) and AO locking hook plate fixation for acute acromioclavicular (AC) joint dislocation. Methods: This study included 61 patients who underwent either closed reduction and trans-acromial fixation with K-wire (group A, 23 patients) or open reduction and internal fixation with AO locking hook plate (group B, 38 patients). Pain on a visual analogue scale (VAS) score, the University of California Los Angeles (UCLA) shoulder score, the American Shoulder and Elbow Surgeons (ASES) score, and active range of motion (ROM) were used in the functional evaluation. For radiological evaluation, coracoclavicular distance (CCD) was measured on both clavicular anteroposterior view and compared between groups. Results: At one-year follow-up, no significant differences in VAS pain score, UCLA shoulder score, ASES score, and active ROM were observed between groups, despite five cases (22.7%, 5/23) of complication in group A. The side-to-side difference between normal and affected CCD was $2.4{\pm}2.2mm$ in group A and $0.2{\pm}0.7mm$ in group B. This difference showed a statistical significance between groups (p<0.001). Conclusions: For the treatment of acute AC joint dislocation, the K-wire trans-acromial fixation group showed a significantly greater CCD than the AO locking hook plate group. In addition, during the follow-up period, much higher incidence of complication related to implant was observed in the trans-acromial fixation group. Although clinical outcomes between groups were not significantly different, these results should be interpreted carefully.

Biological Fixation of $CO_2$ by Chlorella sp. HA-1 in a Semi-Continuous and Series Reactor System

  • LEE JAE-YOUNG;KWON TAE-SOON;BAEK KITAE;YANG JI-WON
    • Journal of Microbiology and Biotechnology
    • /
    • 제15권3호
    • /
    • pp.461-465
    • /
    • 2005
  • Characteristics of biological $CO_2$ fixation by Chlorella sp. HA-1 were investigated in a semi-continuous and series reactor system using an internally illuminated photobioreactor to overcome shortcomings of physicochemical technologies such as adsorption and membrane separation. High $CO_2$ fixation rate was achieved in the semi-continuous reactor system, in which the dilution ratios of the culture medium were controlled. The average $CO_2$ fixation rate was maintained almost constantly when the dilution ratio increased by 0.1 increment from the initial value of 0.5. The total removal efficiency of $CO_2$ was enhanced by employing a series reactor system. The average $CO_2$ fixation rate increased until 4.013 g $CO_2\;day^{-1}$ in a series operation of four reactors, compared to 0.986 g $CO_2\;day^{-1}$ in a batch operation mode. The total $CO_2$ fixation rate was proportional to the number of reactors used in the series reactor system. In the series reactor system of semi-continuous operation, a large amount of $CO_2$ was removed continuously for 30 days. These results showed that the present reactor systems are efficient and economically feasible for a biological $CO_2$ fixation.

Ovadia와 Beals 제2형 또는 3형 경골 천정 골절의 제한적 내고정술을 이용한 치료 (Limited internal fixation for the treatment of the Ovadia and Beals type II or III Pilon fracture)

  • 김형천;김광열;임문섭;김진형;권준형
    • 대한족부족관절학회지
    • /
    • 제7권2호
    • /
    • pp.250-257
    • /
    • 2003
  • Purpose: Pilon fracture is caused by high energy and axial compression forces, and it is often associated with severe comminution and soft tissue injury. Recently, limited internal fixation of this fracture may avoid the soft tissue complications associated with formal open reduction and internal fixation and avoid incongruity of joint margin associated with conservative treatment. We have treated Ovadia and Beals type II or III pilon fracture with limited internal fixation and the results were satisfactory. Materials and Methods: We analyzed 15 cases of Ovadia and Beals type II or III fractures who were treated by limited internal fixation(K-wire or screw fixation) from January 1995 to December 2000. The average follow up period was 20 months(range, 12 to 38 months). According to the Ovadia and Beals classification, seven cases were type II, and eight cases were type III. Radiographic results were assessed by Ovadia and Beals criteria. We also assessed the functional results by Mast and Teipner criteria. Results: Radiographic results showed good in 67% and fair in 33% of cases. Clinical results showed good in 73% and fair in 27% of cases. There were no complications such as wound infection and skin necrosis, but traumatic arthritis were 2 cases. Conclusion: Pilon fractures are high energy injuries with significantly associated soft tissue damage and traumatic arthritis. Limited internal fixation offers good solution to Ovadia and Beals type II or III fracture.

  • PDF

Microplate Fixation without Maxillomandibular Fixation in Double Mandibular Fractures

  • Song, Seung Wook;Burm, Jin Sik;Yang, Won Yong;Kang, Sang Yoon
    • 대한두개안면성형외과학회지
    • /
    • 제15권2호
    • /
    • pp.53-58
    • /
    • 2014
  • Background: Maxillomandibular fixation (MMF) is usually used to treat double mandibular fractures. However, advancements in reduction and fixation techniques may allow recovery of the premorbid dental arch and occlusion without the use of MMF. We investigated whether anatomical reduction and microplate fixation without MMF could provide secure immobilization and correct occlusion in double mandibular fractures. Methods: Thirty-four patients with double mandibular fractures were treated with open reduction and internal fixation without MMF. Both fracture sites were surgically treated. For bony fixations, we used microplates with or without wire. After reduction, each fracture site was fixed at two or three points to maintain anatomical alignment of the mandible. Interdental wiring was used to reduce the fracture at the superior border and to enhance stability for 6 weeks. Mouth opening was permitted immediately. Results: No major complications were observed, including infection, plate exposure, non-union, or significant malocclusion. Five patients experienced minor complications, among whom the only one patient experienced a persistant but mild malocclusion with no need for additional management. Conclusion: This study showed that double mandibular fractures correction with two-or three-point fixation without MMF simplified the surgical procedure, increased patient comfort, and reduced complications, due to good stability and excellent adaptation.

Comparison between Accurate Anatomical Reduction and Unsuccessful Reduction with a Remaining Gap after Open Reduction and Plate Fixation of Midshaft Clavicle Fracture

  • Kim, Joon Yub;Choe, Jung Soo;Chung, Seok Won
    • Clinics in Shoulder and Elbow
    • /
    • 제19권1호
    • /
    • pp.2-7
    • /
    • 2016
  • Background: The purpose of this study is to compare the radiological and clinical outcomes after open reduction and plate fixation of midshaft clavicle fractures between patients who achieved successful anatomical reduction and those who had a remaining fracture gap even after open reduction and plate fixation, and were thus treated with additional demineralized bone matrix (DBM). Methods: This retrospective analysis was conducted on 56 consecutive patients who underwent open reduction and internal fixation using a locking compression plate for acute displaced midshaft clavicle fractures, and who underwent radiographic and clinical outcome evaluations at least 6 months postoperatively. The outcomes between those who achieved perfect anatomical reduction without remnant gap (n=32) and those who had a remaining fracture gap even after open reduction and plate fixation treated with additional DBM (n=24) were evaluated. Results: There were no differences in the use of lag screws or wiring and operation time (all p>0.05) between those with and without remnant gap. No difference in the average radiological union time and clinical outcomes (satisfaction and Constant score) was observed between the two groups (all p>0.05). However, significantly faster union time was observed for AO type A fracture compared with other types (p=0.012), and traffic accident showed association with worse clinical outcomes compared with other causes of injury. Conclusions: Surgical outcome of midshaft clavicle fracture was more affected by initial fracture type and event, and re-reduction and re-fixation of the fracture to obtain a perfect anatomical reduction spending time appears to be unnecessary if rigid fixation is achieved.

The Influence of Fixation Rigidity on Intervertebral Joints - An Experimental Comparison between a Rigid and a Flexible System

  • Kim, Won-Joong;Lee, Sang-Ho;Shin, Song-Woo;Rivard, Charles H.;Coillard, Christine;Rhalmi, Souad
    • Journal of Korean Neurosurgical Society
    • /
    • 제37권5호
    • /
    • pp.364-369
    • /
    • 2005
  • Objective: Spinal instrumentation without fusion often fails due to biological failure of intervertebral joints (spontaneous fusion, degeneration, etc). The purpose of this study is to investigate the influence of fixation rigidity on viability of intervertebral joints. Methods: Twenty pigs in growing period were subjected to posterior segmental fixation. Twelve were fixed with a rigid fixation system(RF) while eight were fixed with a flexible unconstrained implant(FF). At the time of the surgery, a scoliosis was created to monitor fixation adequacy. The pigs were subjected to periodic radiological examinations and 12pigs (six in RF, six in FF) were euthanized at 12-18months postoperatively for analysis. Results: The initial scoliotic curve was reduced from $31{\pm}5^{\circ}$ to $27{\pm}8^{\circ}$ in RF group (p=0.37) and from $19{\pm}4^{\circ}$ to $17{\pm}5^{\circ}$ in FF group (p=0.21). Although severe disc degeneration and spontaneous fusion of facet joints were observed in RF group, disc heights of FF group were well maintained without major signs of degeneration. Conclusion: The viability of the intervertebral joints depends on motion spinal fixation. Systems allowing intervertebral micromotion may preserve the viability of intervertebral discs and the facet joint articular cartilages while maintaining a reasonably stable fixation.

Biomechanical Study of Posterior Pelvic Fixations in Vertically Unstable Sacral Fractures: An Alternative to Triangular Osteosynthesis

  • Chaiyamongkol, Weera;Kritsaneephaiboon, Apipop;Bintachitt, Piyawat;Suwannaphisit, Sitthiphong;Tangtrakulwanich, Boonsin
    • Asian Spine Journal
    • /
    • 제12권6호
    • /
    • pp.967-972
    • /
    • 2018
  • Study Design: Biomechanical study. Purpose: To investigate the relative stiffness of a new posterior pelvic fixation for unstable vertical fractures of the sacrum. Overview of Literature: The reported operative fixation techniques for vertical sacral fractures include iliosacral screw, sacral bar fixations, transiliac plating, and local plate osteosynthesis. Clinical as well as biomechanical studies have demonstrated that these conventional techniques are insufficient to stabilize the vertically unstable sacral fractures. Methods: To simulate a vertically unstable fractured sacrum, 12 synthetic pelvic models were prepared. In each model, a 5-mm gap was created through the left transforaminal zone (Denis zone II). The pubic symphysis was completely separated and then stabilized using a 3.5-mm reconstruction plate. Four each of the unstable pelvic models were then fixed with two iliosacral screws, a tension band plate, or a transiliac fixation plus one iliosacral screw. The left hemipelvis of these specimens was docked to a rigid base plate and loaded on an S1 endplate by using the Zwick Roell z010 material testing machine. Then, the vertical displacement and coronal tilt of the right hemipelves and the applied force were measured. Results: The transiliac fixation plus one iliosacral screw constructions could withstand a force at 5 mm of vertical displacement greater than the two iliosacral screw constructions (p=0.012) and the tension band plate constructions (p=0.003). The tension band plate constructions could withstand a force at $5^{\circ}$ of coronal tilt less than the two iliosacral screw constructions (p=0.027) and the transiliac fixation plus one iliosacral screw constructions (p=0.049). Conclusions: This study proposes the use of transiliac fixation in addition to an iliosacral screw to stabilize vertically unstable sacral fractures. Our biomechanical data demonstrated the superiority of adding transiliac fixation to withstand vertical displacement forces.

Risk Factors Associated with Fixation Failure in Intertrochanteric Fracture Treated with Cephalomedullary Nail

  • Hyung-Gon Ryu;Dae Won Shin;Beom Su Han;Sang-Min Kim
    • Hip & pelvis
    • /
    • 제35권3호
    • /
    • pp.193-199
    • /
    • 2023
  • Purpose: Cephalomedullary (CM) nailing is widely performed in treatment of elderly patients with femoral intertrochanteric fractures. However, in cases of fixation failure, re-operation is usually necessary, thus determining factors that may contribute to fixation failure is important. In this study, we examined factors affecting the occurrence of fixation failure, such as age or fracture stability, after CM nailing in elderly patients. Materials and Methods: This study was conducted retrospectively using registered data. From April 2011 to December 2018, CM nailing was performed in 378 cases diagnosed with femoral intertrochanteric fractures, and 201 cases were finally registered. Cases involving patients who were bed-ridden before injury, who died from causes unrelated to surgery, and those with a follow-up period less than six months were excluded. Results: Fixation failure occurred in eight cases. Comparison of the surgical success and fixation failure group showed that the mean age was significantly higher in the fixation failure group compared with the control group (81.3±6.4 vs. 86.4±6.8; P=0.034). A significantly high proportion of unstable fractures was also observed (139/54 vs. 3/5; P=0.040), with a significantly high ratio of intramedullary reduction (176/17 vs. 5/3; P=0.034). A significantly higher ratio of unstable fractures compared with that of stable fractures was observed in the intramedullary reduction group (132/49 vs. 10/10; P=0.033). Conclusion: Fixation failure of CM nailing is likely to occur in patients who are elderly or have unstable fracture patterns. Thus, care should be taken in order to avoid intramedullary reduction.