• Title/Summary/Keyword: fitting test

Search Result 599, Processing Time 0.028 seconds

A Study on the Effects of the Coefficient of Uniformity and Porosity on the Soil-Water Characteristic Curves of Sandy Soils (사질토의 함수특성곡선에 대한 균등계수와 공극율의 영향에 관한 연구)

  • Yoo, Kunsun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.5
    • /
    • pp.41-47
    • /
    • 2013
  • Well-graded and dense soils have good engineering properties. Unsaturated soil properties such as shear strength, compressibility and permeability are closely related to the soil-water characteristic curve of the soil. Therefore it is important to study the effects of the coefficient of uniformity and the porosity on the soil-water characteristic curve of the sandy soils, which are also related to the grain size distribution and the density of the soil, respectively. In this study soil-water characteristic curves (SWCCs) for six sandy soil specimens were investigated using Tempe pressure cells. The test data were best-fitted to Fredlund and Xing equation. The obtained fitting parameters and the characteristic points of SWCCs were discussed and correlated with the porosity and the coefficient of uniformity of the specimens. The results show that the smaller the porosity of the specimen becomes, the larger the value of the residual matric suction becomes, whereas the larger the coefficient of uniformity of the specimen becomes, the larger the value of the residual matric suction becomes. Regardless of the coefficient of uniformity, the smaller the porosity of the specimen, the flatter the max. slope of SWCC.

Comparative evaluation of sodium hypochlorite and microwave disinfection on dimensional stability of denture bases

  • Nirale, Rutuja Madhukarrao;Thombre, Ram;Kubasad, Girish
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.1
    • /
    • pp.24-29
    • /
    • 2012
  • PURPOSE. To compare the effect of sodium hypochlorite and microwave disinfection on the dimensional stability of denture bases without and with relining. MATERIALS AND METHODS. A brass die was prepared by simulating an edentulous maxillary arch. It was used to fabricate 1.5 mm and 3 mm of thickness denture bases (n = 40). The 1.5 mm of thickness-specimens (n = 20) were relined with 1.5 mm of autopolymerizing relining resin. Five holes were prepared over crest of ridge of brass die with intimately fitting stainless steel pins which were transferred to the intaglio surface of specimens during fabrication of denture bases. For calculation of dimensional changes in denture bases, differences between the baseline area before and after disinfection of the specimens were used. The denture bases without and with relining were divided into 2 groups (each n =20). Data were analyzed using student paired 't'and unpaired 't'test. RESULTS. Microwave disinfection produces significant shrinkage in both denture bases without relining (t =17.16; P<.001) and with relining (t = 14.9; P<.001). Denture bases without relining showed more shrinkage when compared with relined denture bases after microwave disinfection (t = 6.09; P<.001). The changes in dimensional stability after sodium hypochlorite disinfection were not significant for both denture bases without relining (t = 2.19; P=.056) and denture bases with relining (t = 2.17; P=.058). CONCLUSION. Microwave disinfection leads to increased shrinkage of denture bases without and with relining. Chemical disinfection with sodium hypochlorite seems to be a safer method of disinfection with regards to physical properties such as changes in dimensional stability.

Analyses of Fracture Tube Tearing using Gurson Model and Shear Failure Model (Gurson Model과 Shear Failure Model을 이용한 파쇄튜브의 찢어짐 해석)

  • Yang, Seung-Yong;Kwon, Tae-Su;Choi, Won-Mok
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.3
    • /
    • pp.280-285
    • /
    • 2008
  • Two kinds of failure model, that is, the Gurson model and a shear failure model were used for the finite element analyses of simple and notch tensile specimens and axial compression of a fracture tube with initial saw-cuts. The parameter values for the shear failure model were determined by a combined experimental and numerical analysis of the notch tensile specimens. After fitting the numerical parameters such as the yielding stress and the fracture shear strains, the Gurson model and the shear failure model were applied to the analysis of the fracture tube. Although the Gurson model and the shear failure model showed similar fracture behavior for the case of the tensile specimens, the respective results were different in the axial force and the crack growth rate of the fracture tube. That is, the shear failure model required more axial force to make the cracks propagate along the tube than the Gurson model. These are believed to show the lack of damage evolution process of the shear failure model. To decide which model is better in the tube analysis, experimental verification will be necessary.

A study princess line patterns for wedding dresses - Draping technique for standard body type women from age 25 to 34 - (웨딩드레스용 프린세스라인 원형개발 연구 - 25~34세 표준체형 여성을 위한 드레이핑 기법으로 -)

  • Kim, Hae-Yeon;Park, Sun-Kyung;Jeong, Jae-Chul
    • The Research Journal of the Costume Culture
    • /
    • v.25 no.6
    • /
    • pp.913-927
    • /
    • 2017
  • This study is based on the results of the $7^{th}$ Korea Human Size Survey (Size Korea). The standard body shapes of Korean women between 25 and 34 years old were analyzed and used to develop a prototype princess line for wedding dresses. or this purpose I conducted a literature review and a survey of the actual situation of domestic ligaments. In order to select suitable ligaments for the standard body type of 25~34 year-old Korean women, I collected the most representative ligaments from around the world: Stock man from France, Superior from the USA, KIIYA from Japan, and Pig and Nonno from Korea. They were then compared and analyzed. In the form of a formal wedding dress, a prototype princess line was developed by a draping technique in order to finely implement the human body fitting. To develop the prototype of the princess line, I made test garments with muslin. 25 to 34 years old Korean female standard body type Three human subjects close to the average measurement value were selected as subjects. An exterior appearance evaluation questionnaire was created with 28 questions focusing on the main parts of the prototype princess line. The clothes were evaluated three times. In this study, aesthetic and functional elements were considered for the development of princess line prototypes for wedding dresses. In addition, the amount of spare area was given differently. This study is significant in the achievement of a dress line closest that closely matches the human body line of the standard Korean female body type.

Correctional Function of Custom Foot Orthotics for Foot Diseases related to Excessive Pronation during Gait (보행시 과도한 회내와 관련된 발질환을 위한 맞춤형 발보조기의 교정적 기능)

  • Kim, Seung-Jae
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.1
    • /
    • pp.65-79
    • /
    • 2006
  • The purpose of this study was firstly to investigate correctional function of custom semi-rigid foot orthotics for excessively pronated people during gait by observing comfort, navicular movement and leg muscles' activity according to short-term and mid-term wearing duration and secondly to understand positive and/or negative point of view of a recently proposed paradigm related to foot orthotics more profoundly. Sixteen subjects who showed excessive pronation at navicular drop test were recruited for this study. Custom semi-rigid foot orthotics were made fitting for foot characteristics of the subjects by podiatry division of Otto Bock Korea company. While wearing the foot orthotics for two months, comfort of wearing were questioned and vertical navicular movement and electromyography of leg muscles during gait were measured at the condition of both immediately after and 2 months after including a control condition, respectively. The subjects were required to walk on a treadmill at the speed of 1.5m/s and four digital video camera filmed the movement of navicular process at the speed of 60 frames/s. In conclusion, in excessively pronated group continuous increase of comfort from short-term to mid-term wearing of custom foot orthotics is assumed to be closely related with short-term and mid term correctional action, of which are consisted the decrease of the range of navicular drop and navicular raisins- the faster timing of minimum navicular position occurring, and the decrease of leg muscles' activities. This conclusion could lead to positively accept new paradigm related to foot orthotics suggested by Nigg and the author suggest that in the future study the variable which could observe navicular movement would be one of major variables to study preferred path of skeleton in the paradigm.

PERIOD STUDIES OF CLOSE BINARIES, AO CAM AND AW CAM (근접쌍성 AO Cam과 AW Cam의 공전 주기 연구)

  • 김천휘;한원용;나일성
    • Journal of Astronomy and Space Sciences
    • /
    • v.9 no.1
    • /
    • pp.41-51
    • /
    • 1992
  • Photoelectric observations of close binary stars, AO Cam and AW Cam, were made during the 1984 observing season with the 61cm reflector at the Sobaeksan Observatory. One time of primary minimum for AO Cam and three primary epochs for AW Cam were derived from the observations of these two systems. Times of minimum light of these two binaries collected from literature were analyzed with a least square fitting method. New improved light elements for AO Cam and AW Cam were determined. The orbital period of AO Cam had been constant from Octobar, 1980 (JD 244520) to February, 1985 (JD 2446107). However, one secondary time of minimum (JD 2447864.7879) of AO Cam published recently by Mullis and Faulkner(1991) shows large deviation of about 4.6 minutes ($0^d.0032$) from the one predicted by our new light elements. Future observations of times of minima for this system are needed to test this period change. The orbital period of AW Cam has been constant as P=$0^d.77134645$ for about sixty years from the early 1930's to the present.

  • PDF

Utilization of 3D Virtual Garment Simulation Program Proposed for the Evaluation of Movement Fitness - Focusing on the Men's Jean Pants - (동작 적합성 평가를 위한 3차원 가상착의 프로그램 활용 방안 - 남성 진 팬츠를 중심으로 -)

  • Kim, Kyung-A;Uh, Mi-Kyung;Hong, Eun-Hee
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.17 no.4
    • /
    • pp.55-66
    • /
    • 2015
  • The objective of this study is to propose a method by which movement fitness can be evaluated using a three-dimensional virtual garment simulation program. To this end, five types of jean pants for men were evaluated on the program by setting the avatars to make particular movements to examine the level of pressure on each body part. To verify whether the clothing pressure measurement produces valid and reliable results, virtual garment simulation program was utilized. The results indicated that there were significant differences in the levels of pressure on body parts depending on the type of test garment and motion. In addition, the clothing pressure measurement results were in line with the appearance evaluation results suggested by a previous study. Based on this set of results, the nomological validity of the clothing pressure measurement program used in this study was verified. Moreover, we employed an appearance evaluation along with the clothing pressure measurement to verify the reliability of the program; there was a high correlation between clothing pressure measurements and appearance evaluation measurements, indicating that measuring clothing pressures may well compensate for the limitations of appearance evaluation. We expect the results of this study to make valuable contributions in facilitating the digitalization of the fashion industry. Furthermore, this study also is significant in that it has suggested 3D virtual fitting programs as a solution to the long-criticized problem related to the evaluation of movement fitness in existing virtual garment simulation programs.

  • PDF

Analysis of stage III proximal colon cancer using the Cox proportional hazards model (Cox 비례위험모형을 이용한 우측 대장암 3기 자료 분석)

  • Lee, Taeseob;Lee, Minjung
    • Journal of the Korean Data and Information Science Society
    • /
    • v.28 no.2
    • /
    • pp.349-359
    • /
    • 2017
  • In this paper, we conducted survival analyses by fitting the Cox proportional hazards model to stage III proximal colon cancer data obtained from the Surveillance, Epidemiology, and End Results program of the National Cancer Institute. We investigated the effect of covariates on the hazard function for death from proximal colon cancer in stage III with surgery performed and estimated the survival probability for a patient with specific covariates. We showed that the proportional hazards assumption is satisfied for covariates that were used to analyses, using a test based on the Schoenfeld residuals and plots of the Schoenfeld residuals and $log[-log\{{\hat{S}}(t)\}]$. We evaluated the model calibration and discriminatory accuracy by calibration plot and time-dependent area under the ROC curve, which were calculated using 10-fold cross validation.

Module Design and Performance Evaluation of Surge Arrester for Loading In Railway Rolling Stock (전철 탑재형 피뢰기의 모듈설계 및 성능평가기술)

  • Cho, H.G.;Kim, S.S.;Han, S.W.;Lee, U.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2038-2040
    • /
    • 2000
  • The main objective of this paper is to design and test a new type of polymer ZnO surge arrester for AC power system of railroad vehicles. Metal oxide surge arrester for most electric power system applications, electric train and subway are now being used extensively to protect overvoltage due to lightning. Surge arresters with porcelain housing must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of ZnO elements in a surge arrester occurs due to flashover, fault short current flows through the arrestor and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock, pressure rise. etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion. The main research works are focused on the structure design by finite element method, pressure relief of module, and studies of performance of surge arrester for electric railway vehicle.

  • PDF

Optimization of the Turbidity Removal Conditions from TiO2 Solution Using a Response Surface Methodology in the Electrocoagulation/Flotation Process (전기응집/부상 공정에서 반응표면분석법을 이용한 TiO2 수용액의 탁도 처리조건 최적화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.6
    • /
    • pp.491-499
    • /
    • 2009
  • The removal of turbidity from $TiO_2$ wastewater by an electrocoagulation/flotation process was studied in a batch reactor. The response surface methodology (RSM) was applied to evaluate the simple and combined effects of the three main independent parameters, current, NaCl dosage and initial pH of the $TiO_2$ solution on the turbidity removal efficiency, and to optimize the operating conditions of the treatment process. The reaction of electrocoagulation/flotation was modeled by use of the Box-Behnken method, which was used for the fitting of a 2nd order response surface model. The application of RSM yielded the following regression equation, which is an empirical relationship between the turbidity removal efficiency of $TiO_2$ wastewater and test variables in uncoded unit: Turbidity removal (%)=69.76+59.76Current+11.98NaCl+4.67pH+5.00Current${\times}$pH-160.11$Current^2-0.34pH^2$. The optimum current, NaCl dosage and pH of the $TiO_2$ solution to reach maximum removal rates were found to be 0.186 A, 0.161 g/l and 7.599, respectively. This study clearly showed that response surface methodology was one of the most suitable method to optimize the operating conditions for maximizing the turbidity removal. Graphical response surface and contour plots were used to locate the optimum point.