• Title/Summary/Keyword: fitness test

Search Result 635, Processing Time 0.024 seconds

A study on the effects of DINESERV's 5-dimensions by multiply-model on satisfaction, revisit intention and customer loyalty (곱모형에 의한 외식업 서비스품질 5차원이 고객만족도, 재방문의도 및 고객애호도에 미치는 영향)

  • Cho, Yoon-Shik
    • Journal of the Korean Data and Information Science Society
    • /
    • v.20 no.2
    • /
    • pp.273-281
    • /
    • 2009
  • The gap(P-E)-model is based on the disconfirmation paradigm that tries to under stand the effect of the gap between before purchase expectations and after purchase perceptions of the product performance on dependent variables such as customer satis-faction. But Bhote proposed multiply($I{\times}P$)-model instead of gap(P-E)-model in 1998. This paper is focused on Bhote's multiply($I{\times}P$)-model in food service industry. The purpose of this research is to test whether DINESERV's 5-dimensions by multiply($I{\times}P$) model fits in explaining satisfaction, revisit intention and customer loyalty. The F-value of regression model was used to test the fitness of regression model of the multiply($I{\times}P$)-model. Through analysis, it was found that the multiply($I{\times}P$)-model fits.

  • PDF

Evaluation of Fracture Toughness of Heat-Affected Zone in $9\%$ Ni Steel for Inner Wall of LNG Storage Tank (LNG 탱크 내조용 $9\%$ Ni 강 열영향부의 파괴인성 평가)

  • Jang J. I.;Yang Y. C.;Kim W. S.;Hong S. H.;Kwon D.
    • 한국가스학회:학술대회논문집
    • /
    • 1997.09a
    • /
    • pp.45-52
    • /
    • 1997
  • The objective of this study is, with concept of fitness-for-purpose, to evaluate the fracture toughness in X-grooved weld HAZ(heat-affected zone) of QLT(quenching, lamellarizing and tempering)-processed $9\%$ Ni steel, qualitatively and quantitatively, and analyze the relation with the change of microstructure. In general, CTOD test is widely used to determine the fracture toughness of steel weldments. But several problem of accuracy has been brought up. Therefore, in this study, modified CTOD test was used for X-grooved weld HAZ for $9\%$ Ni steel. Additionally, microstructure of HAZ is observed and analyzed by OM, SEM and XRD. From the resulty, HAZ toughness of QLT-$9\%$ Ni steel decreased as the evaluated region approaches the fusion line. The decreased toughness was partly caused by reduction of the retained austenite content, resulted from decreased nucleation site of the retained austenite content, resulted from decreased nucleasion site for reverse transformation due to the increasing fraction of coarse grained region. On the other hand, unexpectedly, the increasing fraction of ductile weld did not increase the HAZ toughness. Therefore, in this X-grooved weld HAZ, the primary factor affecting fracture toughness was the fraction of coarse grained region, i.e., the weakest region.

  • PDF

A Prediction Model of Droplet Size of Rotary Spray Dryer at Various Operating Conditions (원심식(遠心式) 분무건조장치(噴霧乾燥裝置)의 작동조건(作動條件)에 따른 분무입자(噴霧粒子)의 입도예측(粒度豫測) 모델)

  • Noh, S.H.;Kim, K.B.;Lee, J.W.;Lee, S.J.
    • Journal of Biosystems Engineering
    • /
    • v.17 no.3
    • /
    • pp.229-236
    • /
    • 1992
  • In an effort to localize the spray-dryer which is markedly used for drying food materials, a experiment was carried out with a wheel type atomizer locally designed and manufactured to evaluate the effect of rotational speed, feed rate and physical properties of liquid food material on the droplet size, and to develop a model to predict the droplet size sprayed at various operational conditions. The result are summarized as follows. 1. The frequency of droplet size sprayed from the atomizer at every treatment were similar to normal distributions. 2. Under the test conditions adopted in this study, that is, rotational speed of the atomizer ranging from 15,000 to 20,000 rpm (55.0 m/sec - 73.3 m/sec), feed rate from 14 to 37 kg/hr and viscosity of the material from 1.14 to 350 cP, the mean volume-surface dia. of droplets was decreased as increase in rotational speed and was not affected significantly by the feed rate and viscosity. 3. Through the dimensional analysis, a prediction model was developed as follows : $$\frac{Dvs}{r}=K[\frac{Q}{{\mu}r}]^a[\frac{rN^2}{g}]^b[\frac{{\rho}^2r^3g}{{\mu}^2}]^c[\frac{L}{r}]^d$$ and it was proved that the above model was better in degree of fitness than other models reported. 4. A prediction equation for the droplet size sprayed from the atomizer under the test was expressed as follows : $$\frac{Dvs}{r}=0.0215[\frac{Q}{{\mu}r}]^{0.06}[\frac{rN^2}{g}]^{0.3314}[\frac{{\mu}^2}{{\rho}^2r^3g}]^{0.0158}$$.

  • PDF

A Study on the Basic Bodice Pattern for the Fatty Body -The subject of middle-aged women- (비만체형을 위한 기본 Bodice 원형연구 -중년기 부인을 중심으로-)

  • 한애미
    • Journal of the Korean Home Economics Association
    • /
    • v.25 no.3
    • /
    • pp.15-26
    • /
    • 1987
  • The purpose of this study was to develop the pattern drafting method which would be suitable to their physical characteristics for the fatty body of 40∼55 aged Korean women who are more than 1.5 Rohrer's Index and 90㎝ bust girth. The study was composed as follows; 1. Body measurement and statistical analysis: One hundred and thirty women were measured on 29 items. Thirty-four items including 29 measured items and 5 calcutated items were analyzed statistically. 1) Mean, standard deviation, variance, maximum, minimum, range were computed. 2) Correlation coefficients between each items were computed. 2. Development of new bodice pattern drafting method: Measurement items necessary to draft new bodice pattern were bust girth, center back waist length, shoulder width, back width, chest and neck base girth. The new pattern was examined through three wearing tests for completion. 3. Evaluation of the new pattern drafting method: The new pattern was objectively evaluated by the sensory test. The sensory evaluation was applied to evaluate the new pattern for the fatty body women by comparint it with the conventional patterns. The results of sensory tests of the new pattern are as follows: 1) The composite reliability coefficient is 0.7698, and the reliability of sensory test shows high. 2) According to a statistical analysis of the result of the 23 items on the questionaire, all the items showed significant differences(α 0.01) between the two, with the new pattern having higher scores. The new pattern is better conventional pattern as the average mark of the former is 3.901 but that of latter is 2.926. The new pattern drafting method proved to be superior to the conventional one especially in the fitness at the center front neck point, shoulder point, side line, armscye depth, position of bust point, chest width line, under arm dart and the shoulder line.

  • PDF

The Effect of Health Promotion Program for Frail Elderly Residents on Health Promoting Behavior and Health Status (허약노인을 위한 건강증진 프로그램이 허약노인의 건강증진행위와 건강상태에 미치는 효과)

  • Kwon, Sang Min;Park, Jeong Sook
    • Korean Journal of Adult Nursing
    • /
    • v.25 no.2
    • /
    • pp.194-206
    • /
    • 2013
  • Purpose: The purpose of this study was to develop a health promotion program for frail elderly nursing home residents, and to analyze the effects of the program. Methods: The research was a nonequivalent control group pretest-posttest design. Data collection was performed from February 26, 2012, to April 26, 2012. The subjects were 28 residents for the experimental group, who were selected at A nursing home, D city, in Korea and 27 residents for the control group, who were selected at B nursing home. Data were analyzed using descriptive statistics, ${\chi}^2$-test, independent t-test, ANCOVA and Cronbach's ${\alpha}$ with SPSS/Win 17.0 program. Results: There was a significant improvement in health promoting behaviors (F=64.26, p<.001), Lt. Grip strength (F=39.76, p<.001), Rt. Grip strength (F=38.06, p<.001), Static balance (F=3.98, p=.050), TUG (F=18.60, p<.001), oral status (F=26.75, p<.001), depression (F=18.79, p<.001), and subjective health status (F=10.75, p<.002) in the treatment group compared to the comparison group. Conclusion: The health promotion program improved the health promoting behavior, physical fitness, oral status, depression, and subjective health status of the frail elderly nursing home residents. Therefore, health promotion programs for frail elderly nursing home residents could be helpful.

Speckle Noise Reduction of Ultrasonic NDT Using Adaptive Filter in WT Domain (웨이브렛 변환 평면에서 적응 필터를 이용한 초음파 비파괴검사의 스펙클 잡음 감소)

  • Jon, C.W.;Jon, K.S.;Lee, Y.S.;Lee, J.;Kim, D.Y.;Kim, S.H.
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.5
    • /
    • pp.21-29
    • /
    • 1996
  • Industrial equipment, such as power plant, is required to operate reliably, continuously and economically under rather severe conditions of temperature, stress, and enbironment. To test structural integrity and fitness, ultrasonic nondestructive testing is used because of effectiveness and simplicity. In this paper, wavelet transform based least mean square(LMS) algorithm is applied to reduce the influence of the interference occurring between randomly positioned small scatters. The RUN test is performed to check the nonstationarity of the speckle noise signal. The performance of this new approach is compared with that of the time domain LMS algorithm by means of condition numbers, signal-to-noise ratio and 3-D image. As a result, the wavelet transform based LMS algorithm shows better performance than the time domain LMS algorithm in this experiment.

  • PDF

Evaluation of the Effectiveness of Dietary Education and Exercise Program on Obese Adults in Chuncheon Area (춘천지역 일부 비만인 성인대상 식생활교육과 운동중재 프로그램의 효과평가)

  • Won, Sun-Im;Yoo, Young-Ju
    • Korean journal of food and cookery science
    • /
    • v.32 no.1
    • /
    • pp.123-135
    • /
    • 2016
  • The purpose of this study was to evaluate the effectiveness of an intervention program using dietary consult and physical exercise conducted by public health center in Chuncheon city for obese adults. This study used a pretest-posttest design. The subjects were 58 out of 90 obese adults with body mass index (BMI) greater than $25kg/m^2$ who completed all education sessions for 8 weeks. Data on dietary habits, dietary behaviors, nutritional knowledge, anthropometric parameters and biochemical indices and daily nutrient intakes assessed by a 24-hour recall were collected before and after the intervention program., in order to evaluate program effectiveness. After the intervention, there were positive changes in exercise status and dietary habits and nutrition knowledge accuracy. Especially, the answer of 'I drink a cup of milk every day' were significantly improved (p<0.001), and the answer of 'I don't overeat', which is a dietary attitude question was significantly improved (p<0.05). Dietary intakes of most of nutrients were not significantly different between pre-test and post-test. But calcium (p<0.05), potassium (p<0.05), vitamin A (p<0.01), vitamin E (p<0.05), and folic acid (p<0.05) were significantly increased in the female group after the intervention. Weight (p<0.05), BMI (p<0.01), blood pressure (p<0.001), were significantly decreased after program, but changes of skeletal muscle mass, body fat mass were not significant. Resting heart rate (p<0.01), flexibility (p<0.001), whole body reaction (p<0.05), grip strength (p<0.01) and balance (p<0.01) showed positive changes after the intervention. Blood glucose level in serum was significantly decreased (p<0.001). These results indicated that dietary education and exercise program was effective not only for weight reduction but also for the improvement of physical fitness in obese adults.

A Experimental Study on the Performance of Filter-integrated Half-masks (우리나라 면체 여과식마스크 성능에 관한 연구)

  • 변임근;이영섭
    • Journal of the Korean Society of Safety
    • /
    • v.5 no.3
    • /
    • pp.3-7
    • /
    • 1990
  • This study is conducted to experiment on the performance test for 20 types of Filter-integrated Half-masks which could not only protect workers exposed to dusty environment, but also improve workability. Results and conclusions are as follows : 1) Respirators that removal efficiency of aerosols is 95 percent or more are 11 kinds(55%), and those who are 99.9 percent or more are 4 kinds(20%). Respirators that inhalation resistance is 4 mm in water or less are 13 kinds(65%), and those who are 6 mm in water or less are 17 kinds(85%). Respirators that efficiency of cumulative inhalation resistance is 100 percent or less are 11 kinds(55%) . 2) Respirators that resistance of moisture inhalation is 6 mm in water or less are 11 kinds(55%). and those who are 10 mm in water or less are 13 kinds(65cio), Respira'tors that ratio of removal efficiency for aerosols between dry and wet conditions is 95 percent or more are 9 kinds(45%). 3) Respirators which are not only 95 percent or more for removal efficiency of aersosls and 6 mm in water or less for inhalation resistance, but also 200 percent or less for efficiency of cumulative inhalation resistance, are 8 kinds(40%). Respirators which are not only 99.9 percent or more for removal efficiency and 6 mm in water or less for inhalation resistance, but also 100 percent or less for efficiency of cumulative inhalation resistance, are 3 kinds(15%). Respirators which are not only 95 percent or more for removal efficiency of aerosols and 6 mm in water or less for inhalation resistance, but also 200 percent or less for efficiency of cumulative inhalation resistance and 10 mm in water or less for resistance of moisture inhalation, are 6 kinds(30%) . 4) As standard rrlodel of artificial human head which would be perhaps different from the true one Is used to experiment fitness test, leakage rate is shown to be more or less high. However, artificial human head shall be accurately examined and follow-up studt. would be conducted in the future.

  • PDF

Virtual Test Framework for Smith Squat Exercise Based on Integrated Product-Human Model (제품과 인체의 통합 모델을 바탕으로 한 스미스 스쿼트 운동의 가상 시험 프레임워크)

  • Lee, Haerin;Jung, Moonki;Lee, Sang Hun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.8
    • /
    • pp.691-701
    • /
    • 2017
  • The barbell squat is a fundamental physical exercise for strengthening the lower body and core muscles. It is an integral part of training and conditioning programs in sports, rehabilitation, and fitness. In this paper, we proposed a virtual test framework for squat exercises using a Smith machine to simulate joint torques and muscle forces, based on an integrated product-human model and motion synthesis algorithms. We built a muscular skeletal human model with boundary conditions modeling the interactions between the human body and a machine or the ground. To validate the model, EMG, external forces, and squat motions were captured through physical experiments by varying the foot position. A regression-based motion synthesis algorithm was developed based on the captured squat motions to generate a new motion for a given foot position. The proposed approach is expected to reduce the need for physical experiments in the development of training programs.

Comparison of the accuracy of domestic dental intra-oral scanner(e-scanner) and model scanner (국산 치과용 구강스캐너(e-scanner)와 모델스캐너의 정확도 비교)

  • Kim, Busob;Kim, Jungho
    • Journal of Technologic Dentistry
    • /
    • v.41 no.2
    • /
    • pp.53-61
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate the discrepancy of scan process in dental intra oral scanner by comparing model scanner and anticipate possibility to introduce intra oral scan technique. Methods: 3D superimposition test was conducted to compare the scan discrepancy. The scanners used in this study are the e-oral scanner, the D750 model scanner, and the high precision CMM(3D Coordinate Measuring Machine). The standard of accuracy verification is ISO 5725-1; trueness and precision. Master model was manufactured by dental stone and scanned 5 times by intra oral, model scanner. Reference data was scanned 5 times by high accuracy CMM to evaluate the trueness. Results: Trueness of D750 scanner were $7.4{\mu}m$ $5.1{\mu}m$ $6.8{\mu}m$ at an abutment, an occluasal, a specific area. and trueness of e-scanner were $20.2{\mu}m$ $27.4{\mu}m$ $37.8{\mu}m$ at an abutment, an occluasal, a specific area. Precision of D750 scanner was $7.04{\mu}m$, e-scanner was $15.95{\mu}m$. Conclusion: When conducting in vitro test, The mean difference of trueness between e-scanner and D750 were $12.8{\mu}m$ at an abutment area, $22.3{\mu}m$ at an occlusal area, $31.0{\mu}m$ at a specific area and $8.91{\mu}m$ in precision. The scan discrepancies are within the range of clinical acceptance.