The Bias Error due to Windows for the Wigner-Ville Distribution Estimation (위그너-빌 분포함수의 계산시 창문함수의 적용에 의한 바이어스 오차)

  • 박연규;김양한
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.80-85
    • /
    • 1995
  • Too see the effects of finite record on the estimation of WVD in practice, a window which has time varying length is examined. Its length increases linearly with time in the first half of the record, and decreases from the center of the record. The bias error due to this window decreases inversely proportionally to the window length as time increases in the first half. In the second half, the bias error increases and the resolution decreases as time increases. The bias error due to the smoothing of WVD, which is obtained by two-dimensional convolution of the true WVD and the smoothing window, which has fixed lengths along time and frequency axes, is derived for arbitrary smoothing window function. In the case of using a Gaussian window as a smoothing window, the bias error is found to be expressed as an infinite summation of differential operators. It is demonstrated that the derived formula is well applicable to the continuous WVD, but when WVD has some discontinuities, it shows the trend of the error. This is a consequence of the assumption of the derivation, that is the continuity of WVD. For windows other than Gaussian window, the derived equation is shown to be well applicable for the prediction of the bias error.

  • PDF

Intelligent and Responsive Window Opening-Closing Operation Process for Carbon Dioxide(CO2) Management of Secondary School Classroom (중등학교 교실의 이산화탄소(CO2) 관리를 위한 지능형 창호개폐 작동 프로세스)

  • Choi, Yoon-Young;Lee, Hyun-Soo
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.25 no.4
    • /
    • pp.19-30
    • /
    • 2018
  • The school classroom is a common living place where students spend 7 to 14 hours a day to prepare for their careers. Therefore, if the ventilation of the classroom is not properly performed, it may lead to the deterioration of learning ability due to the unclear air. The concentration of carbon dioxide in the classroom is reported to be high, and the increase in carbon dioxide concentration has a negative effect on the learner's academic performance. In this context, the purpose of this study is to propose a methodology for intelligent and responsive window opening-closing operation process that can reduce the concentration of $CO_2$ in the classroom in order to build a support space that can create an effective teaching-learning environment for adolescents. The specific objectives are as follows. First of all, we define the concept of window opening-closing operation. Secondly, twe develop the operation process of window opening-closing. Thirdly, we develop an algorithm for real-time window opening and closing (process) (Window Opening-Closing Operation Process). Finally, we verify the intelligent responsive window opening-closing operation process through developing examples of window opening-closing operation process using the parametric design program. This study is a preliminary study to develop algorithms necessary for window opening-closing operation. Based on the first-order algorithm, We simulated window opening-closing operations according to a hypothetical scenario. As a result, This study can show that the window is open and close depending on the $CO_2$ concentration, but the $CO_2$ concentration in the room is higher than outdoors. Consequentially, we suggest that it is necessary to develop an algorithm to supplement these results because window is often not working when the temperature difference between indoor and outdoor in winter is large.

The duodenal window approach to pancreatoduodenectomy

  • Giovanni Domenico Tebala;Jacopo Desiderio;Domenico Di Nardo;Alessandro Gemini;Roberto Cirocchi
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.28 no.2
    • /
    • pp.262-265
    • /
    • 2024
  • The pancreatoduodenectomy (PD) technique is yet to be standardized. One of the most difficult passages in PD is the mobilization of the second, third, and fourth parts of the duodenum. This maneuver is classically performed from the supramesocolic space after the division of the gastrocolic ligament, but traction on the transverse mesocolon and the superior mesenteric pedicle can cause bleeding from the venous and arterial branches of the pancreatic head and uncinate process. We hereby describe a technique to access and mobilize the distal duodenum and proximal jejunum (D2 to J1) through the duodenal window and the Treitz's foramen, performing an almost complete Kocher's maneuver before opening the gastrocolic ligament and mobilizing the hepatic flexure. The anatomical basis and the surgical technique of the duodenal-window-first PD are discussed. The duodenal-window-first approach is a standardizable step of PD that allows an easy and safe mobilization of D2 to J1. This technique has been applied to 15 cases of PD, both open and robotic, with no specific morbidity. Therefore, we propose the adoption of the duodenal-window-first technique as a routine standardized step of PD.

Thermal Performance Evaluation of Junction Thermal Bridge according to Installation Position of Window

  • Lee, Soo-Man;Kim, Dong-Yun;Ahn, Jung-Hyuk;Eom, Jae-Yong;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.15-21
    • /
    • 2017
  • Purpose: "Building energy design standard" is used to limit the thermal transmittance of building in Korea. However, it only covers the insulation standard for each appropriate elements of a building, not the thermal performance of Junction thermal bridge of windows and doors installed in wall. Therefore in this study, we have evaluated the thermal performance of Junction thermal bridge depending on installation method and position of windows and provide it as design data. Method: We analyzed heat transfer of 4-Track sliding window and tilt & turn triple glazed window that are placed in the first class category on window energy efficiency rating using Window 7.4 and Therm 7.4. Result : First, linear thermal transmittance of 4-Track sliding window differs by 2.2 times or more depending of installation method and location. It is higher than the linear thermal transmittance, 0.01W/mK, proposed by Passivhaus. Second, linear thermal transmittance of Tilt & turn triple glazed window differs by 7.7 times or more depending of installation method and location. The average linear thermal transmittance was less than 0.01W /mK when windows were installed on the internal wall insulation by the fixed hardware attachment method. Third, the thermal losses of a window caused by a junction thermal bridge are inversely proportional to the window area and converge gradually as the area increased.

A Study on the Establishing of Single Window System for Simplification of Trade Procedures (무역절차 간소화를 위한 Single Window 구축에 대한 연구)

  • Song, Seon-Uk
    • International Commerce and Information Review
    • /
    • v.7 no.4
    • /
    • pp.157-177
    • /
    • 2005
  • In many countries, a Single Window system for simplifications is establishing in order to reduce works submitted double data and compliance costs. A Single Window is defined as a facility that allows parties involved in trade and transport to lodge standardized information and documents with a single entry point to fulfil all import, export, and transit-related regulatory requirements. A Single window can bring improved level of security, faster clearance and reduced compliance costs. UN/CEFACT released "Recommendation and Guidelines on establishing a Single Window to enhance the efficient exchange of information between trade and government". Also, WCO has made progress several projects to assist effective establishing a single window, i.e. CDM, UCR, ICT. Korea has being established a single window system, "e-trade platform" connected with trade, clearance, logistics, marketing and payment system. Some suggestions to establish a effective single window system in Korea are as follows. Firstly, it is necessary to clearly define roles and responsibilities of a lead agency in a single window system and form a organic relationship with PGA. Secondly, a single window system has to be progressed by stages, namely, customs clearance portal system should be established first, and later established e-trade platform. Lastly, the Korean government has to take part in CDM project to gain an advantage over other countries.

  • PDF

The Change of Heating and Cooling Load according to the Thermal Insulation Performance of Window for an Apartment House (창호의 단열성능에 따른 공동주택 냉난방 부하량 변화)

  • Song, Su-Bin;Kim, Young-Tag;Yoon, Seong-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.853-856
    • /
    • 2008
  • Windows have an great effect on annual building load because windows are the weakest parts of building envelope thermally. To reduce the consumption of building energy, the thermal performance of window has to be improved in first place. Therefore this research aims to make a quantitative analysis of the heating and cooling load according to the window thermal performance using the heat load simulation program. As a result of the simulation, annual heat load is down 38% according to the decrease of U-value of window, 1.00 W/$m^2K$. and annual heat load is up 10% according to the decrease of shading coefficient, 0.20. The annual load of the window with Low-E glass is 15% lower than the window with pair glass.

  • PDF

A Research on the Characteristics of the Contemporary Fashion Show Window Display -Focus on the Characteristics of Contemporary Art- (현대 패션 쇼윈도 디스플레이의 특성에 관한 연구 -현대 예술의 특성을 중심으로-)

  • Kim, Nayun;Chun, Jaehoon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.39 no.6
    • /
    • pp.789-798
    • /
    • 2015
  • This research analyzes trends of fashion show window displays, regarding it as a new form of installation art that has the characteristics of contemporary art. Fashion show window displays are more than a physical space for displaying and have emerged as a new space in which creative expressions of arts take place. This research presents the characteristics of contemporary fashion show window displays by analyzing the characteristics of contemporary art. First, recent show window displays have shown "decentralization": various themes, forms, and mediums that are accepted without discrimination. Recent show window displays deviate from conventional methods, constantly pursuing experimental and progressive ideas and also include categories of current art, body art, and live art. Second, show window display has "interactiveness" that enables two-way communication between audiences and art, rather than fixing audiences as receptive viewers. Third, "textuality" can be found in show window displays. Recent show windows are use "objects" to show products as well as to express the meaning and symbols of products. A new directionality and effective strategies are shown to be imperative for the future development of fashion show window displays.

Study on Estimate of Thermal Resistance of PVC Frame Window Due to Material Composition (PVC 창호의 구성에 따른 단열성능 예측에 관한 연구)

  • Sung, Uk-Joo;Lee, Jin-Sung;Cho, Soo;Jang, Cheol-Yong;Paek, Sang-Hun;Song, Kyoo-Dong
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1075-1080
    • /
    • 2006
  • Purpose of this study is proposal of estimating method about window thermal performance that based on KS F 2278 'Test method of thermal resistance for windows and doors' due to material composition of PVC frame window. First step of this study is research of present state about material composition of PVC frame window. Second is selection of main effective elements about window thermal resistance. For example, composition of Glazing, Frame area ratio of total window area, frame width, opening type, area of heat transfer and so on. Third is multiple regression analysis about thermal performance of PVC frame window due to main effective elements. It produces equations of multiple regression analysis due to opening type. Case of sliding window is $Y=0.149+0.034X_g+0.248X_{far}$, 4track sliding is $Y=0.584+0.175X_g+1.355X_{far}-0.008X_{fw}$, Tilt & Turn window is $Y=-0.161+0.076X_g+0.576X_{far}+0.0008X_{fw}$.

  • PDF

Energy Consumptions and Daylight Illumination levels of a Multi-beded Patient Room according to the Window Shapes and Shading (창의 형태 및 차양 계획에 따른 다인 병실의 에너지소비량과 주광조도의 평가 및 분석)

  • Choi, Changdae;Kwon, Soonjung;Kim, Sunsook
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.18 no.3
    • /
    • pp.29-39
    • /
    • 2012
  • Window and shading designs have a great influence on energy consumption and daylighting in buildings. As far as energy is concerned, small window area is advantageous. But it is not good to the patient healing in hospital. So it is important to find out the optimum window shape which is favorable for both energy consumption and patient healing. In this study, annual energy consumption and daylight illumination levels were analyzed according to the window shapes and shading devices for a multi-beded patient room in hospitals. The simulations were conducted for 19 different cases by COMFEN 4.0 computer simulation program. The results of this paper are as follows. First, window to wall area ratio and shading devices have great influences on annual energy consumption. But it is a problem in that they decrease significantly daylight level in bed room. Second, considering the same energy consumption, reducing the width of window rather than the hight of window is desirable for the secure of daylight level. Third, increase of the number of horizontal shade is not desirable in south face of the building for the energy consumption and daylight level. Fourth, sun shade is not necessary in north face of the building for the energy consumption and daylight level.

A Study on the Performance Test and Verification of Heat Transfer characteristics in Automobile Rear Window Heater (자동차 후면 유리 열선의 열전달특성에 따른 성애제거 성능평가 및 성능검증 방법에 관한 연구)

  • Juen, H.Y.;Lee, C.K.;Bae, H.J.;Lee, S.J.
    • Journal of Power System Engineering
    • /
    • v.9 no.2
    • /
    • pp.73-80
    • /
    • 2005
  • Both theoretical and experimental investigations were conducted to analyze defrosting behavior of a window heater operating in the low outdoor temperature($-20^{\circ}C$). To achieve this purpose, first a warm-chamber experiment($23^{\circ}C$) was performed to measure inner and outer surface temperature of the rear window(heated by the electric heater supplying 195 W) as functions of both time and position. Secondly, a cold chamber experiment was made to continuously record defrosting process of the frosted window. From the comparisons of the two experimental results, it was found that there was a similarity between the spatial distributions of both temperature and remaining frost. Thus, the temperature data from the warm-chamber experiments can be utilized to predict an expected zone covered with remaining frosts, and this approach can also be adopted in the inspection process in order to economically guarantee optimized performance of the window heater. Finally, an analytical model based on one-dimensional, steady-state heat transfer theories was proposed and successfully predicted the outer surface temperature of the rear window surrounded by cold air($-20^{\circ}C$) for the given operating conditions(heater power, inside and outside heat transfer coefficients, and surrounding air temperature, etc.).