• Title/Summary/Keyword: fire-retardant chemical

Search Result 48, Processing Time 0.032 seconds

The Cause of Whitening by Flame Retardants Treatment on Korean Wooden Cultural Heritage

  • Kim, Jin Qyu;Chung, Yong Jae;Lee, Hwa Soo;Seo, Hyun Jeong;Son, Dong Won;Han, Gyu-Seong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.4
    • /
    • pp.589-599
    • /
    • 2016
  • Korean wooden cultural heritages are treated by flame retardants to protect fire hazards. Two types of flame retardants are used to treat wooden cultural heritage. These flame retardants cause some problems such as surface whitening, discoloration, and cracks due to the chemical reaction caused by Korean traditional wood painting (Dancheong), flame retardant and wood humidity. The Korean government is trying to cut down on the amount of flame retardants for the wooden cultural heritage because of these problems. This study was carried out to find the cause of whitening by flame retardants treatment. The reaction between pigment and flame retardant chemicals was analyzed by infrared spectroscopy.

Study on Property Modification with Polymer Compositions in the Manufacture of Compounds for Cable Sheath

  • Li, Xiang Xu;Lee, Sang Bong;Cho, Ur Ryong
    • Elastomers and Composites
    • /
    • v.54 no.3
    • /
    • pp.220-224
    • /
    • 2019
  • Herein, three polymer compounds were manufactured using three polymer combination methods, ethylene-vinyl acetate/ethylene-propylene-diene-copolymer (EPDM), ethylene-vinyl acetate (EVA)/polyethylene-A (PE-A; density: 0.870), and ethylene-vinyl acetate (EVA)/polyethylene-B (PE-B; density: 0.885), for making cable sheath for use in the shipping industry. In this study, EVA, EPDM, PE-A, and PE-B were used as matrix polymers, and EVA-grafted maleic anhydride was used as a coupling agent for compounding with various compounds such as a fire retardant, cross-linking agent, filler, and other additives, besides the plasticizer. ${\Delta}T$, Mooney viscosity, and tensile strength increased in order of EPDM < PE-A < PE-B, the probable reason is due to the different crosslinking effect. The three compounds showed similar results for fire resistance and aging resistance after compounding process, but they showed excellent cold resistance owing to the non-polarity of the polymers and sufficient plasticizer content.

A Study on Effect of Coating Stain on the Performance of Electric Cable (도장 오염이 Electric Cable의 성능에 미치는 영향 연구)

  • Cho, Yeon-Ho;Lee, Sang-Hyeok;Son, Young-Shuk
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2009.09a
    • /
    • pp.18-23
    • /
    • 2009
  • After the installation of electric cables at block, PE(pre-erection) and hull stages, the coating stains on the electric cable sheath were unavoidably occurred by additional painting process. According to class rules paint or coating applied on the electric cables shall not adversely affect the mechanical, chemical of fire resistant characteristics of the electric cable sheath. However, there has not been quantitatively studied about the effect of coating stains on properties of sheath materials. In this study, we tried to investigate the effect of coating stains on the performance and deterioration of sheath materials by using FTIR, SEM analysis, flame retardant, high potential voltage and tensile test. The results sowed that coating stains, which were occurred during painting work on site could not adversely affect on the performance and deterioration of sheath materials.

  • PDF

Field Treatments of Small Diameter Logs Using Sap Displacement Method (I) - Feasibility of Treatment Using Transpiration Method and Butt-end Method - (수액치환법을 이용한 소경재의 산지처리(I) - 증산법과 원구법을 이용한 처리 가능성 -)

  • Chun, Su-Kyoung;Kim, Jae-Jin;Ra, Jong-Bum;Kim, Gyu-Hyeok
    • Journal of the Korean Wood Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.58-65
    • /
    • 2002
  • This research was carried out to develop field treatment techniques of thinned small diameter softwood logs and less utilized hardwood logs using sap displacement method. In this paper, we report the feasibility of using transpiration method and butt-end method for the treatment of three softwood species and three hardwood species with preservatives, fire-retardant chemicals, and dimensional stabilizer. Butt-end method was effective as a field treatment technique compared to transpiration method when considered the treatability, easiness of treatment, productivity of treated wood, and environmental aspects related to chemical treatment, regardless of the combination of wood species and chemicals.

Studies on the Press Drying and the Chemical Absorption of the Plywood Treated with Diammonium Phosphate (제2인산(第2燐酸)암모늄 처리합판(處理合板)의 약제흡수(藥劑吸收) 및 열판건조(熱板乾燥)에 관(關)한 연구(硏究))

  • Kim, Jong-Man
    • Journal of the Korean Wood Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.39-45
    • /
    • 1995
  • The plywoods commonly used as decorative interior materials for the construction are inflammable and so it is a causative factor for making fire accidents, resulting in the destruction of human life and personal properties. Indeed, it is, therefore, required to produce fire-retardant plywoods. In this study, a special grade of defect-free, Kapur plywood was used. Specimens were cut into 3- by 20cm dimensions from 120- by 240- by 0.33-cm panels(thin panel) or 120- by 240- by 0.5-cm panels(thick panel). Some specimens were treated with diammonium phosphate(DAP), but some were not treated with diammonium phosphate to use as control panels. Chemical absorption, drying curves, drying rates and dynamic Young's modulus were investigated. The results were summaries as follows; 1. The specimens were soaked into 19% diammonium phosphate solution by a full cell pressure process and the diammonium phosphate retained in the thin and thick plywoods was 1.409kg/$(30cm)^3$, 1.487kg/$(30cm)^3$, respectively. 2. Diammonium phosphate-treated plywoods were redried with press-drying process at one of either condition dried on the platen($115^{\circ}C$) for a period of time or dried on the platen($50^{\circ}C$) for 3 hrs plus in a dry-oven($30^{\circ}C$) for 24 hrs. or dried on the platen($60^{\circ}C$) for 2 hrs plus in a dry-oven($30^{\circ}C$) for 24 hrs. The drying rate of treated thin specimens dried at $60^{\circ}C$ plus $30^{\circ}C$ and $115^{\circ}C$ only was found to be 0.04 %/min. and 8.53 %/min. Similarly, the drying rate of treated thick specimens were 0.03 %/min. and 6.77 %/min. respectively. 3. It was evident that highly-significantly different drying rate of treated plywoods was observed between plywood thicknesses and platen temperatures and the rate was increased by elevating the platen temperature up to $115^{\circ}C$. Based on the two-way variance analysis, highly significant drying rate was observed from the interaction between plywood thicknesses and platen temperatures. 4. After redrying, the specimens were weighed and reconditioned to a constant weight in a facility maintained temperature ($20^{\circ}C$) and relative humidity(65%) prior to test dynamic Young's modulus. The test revealed that the thin specimens dried at the platen temperature of $50^{\circ}C$, $60^{\circ}C$, $115^{\circ}C$ and untreated specimens showed 1.070E+09 dyne/$cm^2$, 1.156E+09 dyne/$cm^2$, 1.243E+09 dyne/$cm^2$, and 1.052E+09 dyne/$cm^2$, respectively. Likewise, the thick specimens revealed 5.647E+09 dyne/$cm^2$ 5.670E+09 dyne/$cm^2$, 6.395E+09 dyne/$cm^2$ and 5.415E+09 dyne/$cm^2$, respectively. 5. It was evident that significantly different dynamic Young's modulus was observed between the plywood thickness and the platen temperature, but not in the two-way interaction between the plywood thickness${\times}$the platen temperature.

  • PDF

Properties and Thermal Characteristics of Phenol Foam for Heat Insulating Materials (단열재용 페놀폼의 물성과 열적특성)

  • Kim, Dong-Kwon;Lee, Soo-Bok
    • Applied Chemistry for Engineering
    • /
    • v.17 no.4
    • /
    • pp.357-360
    • /
    • 2006
  • In this study, we studied the physical properties and application of PF foam as heat insulating materials. In the experimental results, the density of PF foam showed $0.030g/cm^3$ and the thermal conductivity showed $0.026kcal/m.h.^{\circ}C$. Also, thermal resistance of the prepared PF foam was volatilized about 71.7 wt% when the temperature was $500^{\circ}C$ (1 h). And the chemical structure of PF foam have a closed cell type in the important properties as heat insulating materials. Therefore, it was confirmed that the prepared PF foam had excellent performance as heat insulating materials.

Study on Property Modification with Kind and Additive Amount of Plasticizer in the Manufacture of Compounds for Cable Sheath (전선피복용 컴파운드의 제조에서 가소제의 종류와 첨가량에 따른 물성 변화 연구)

  • Li, Xiangxu;Lee, Sang Bong;Cho, Ur Ryong
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.2
    • /
    • pp.11-16
    • /
    • 2019
  • The four different polymer compounds were manufactured with the two kinds of plasticizers [(di-2-ethylhexyl sebacate(DOS), and di-2-butyl sebacate(DBS)] and two different additive amounts(18, 26 phr) of the same plasticizer for making cable sheath for ship. Ethylene-vinylacetate, ethylene-propylene-diene-copolymer as matrix polymers and ethylene-vinylacetate grafted maleic anhydride as coupling agent were selected for compounding with fire retardant, closslinking agent, filler, and other additives besides plasticizer. The compound including DOS showed the higher ${\Delta}T$ than that including DBS at the same additive amount in the rheology test. And with increasing plasticizer, the compounds resulted in lower tensile strength and higher elongation by lubricating effect of plasticizer. DOS yielded better aging resistance and cold resistance than DBS due to the good heat resistance and low solidifying point of DOS compared to DBS.

Mechanical Properties of Reclaimed Plastic Concrete (재생수지콘크리트의 역학적 성질에 관한 연구)

  • 전진영;고재군
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.29 no.4
    • /
    • pp.132-141
    • /
    • 1987
  • The objective of the study was to obtain the compressive the tensile and the fleniril strengthes, thermal resistance, chemical resistance and fire resistance of the reclaimed plastic corcrete in order to investigate the feasibility as a new construction material This reclaimed plastic concrete is a compositive material which is composed of sand and blend of 50% of LDPE(Low density polyethylene) and 50% of HDPE (High density polyethylene) which are inexpensive and easy to reclaim. The results obtained in the study are summarized as follows: 1. As the binder content ranging from 20 to 40 % increase, the compresie, the splitting tensile and the flexural strengthes were increased. The compressive strenzth of the specimen tested was the highest and flexural strength the next and tensile strength the lowest 2. The compressive, the tensile and flexural strengthes of specimens made of fine sand were higher than those of coarse sand. The compressive, the tensile and the flexural strengthes of specimens made of high pressure molding were higher than those of low pressure molding. 3.In comparison with different additives, the specimens with carbon black was excellent and B. H. T. good and ferric oxide poor for thermal resistance. 4. In relationship between the flexural strength with varying temperature from -23$^{\circ}C$ to 80$^{\circ}C$. The flexural strengthes were decreared as temperature increased at 25 %, 30 % and 35 % of binder contents, respectively. Especially at 60$^{\circ}C$, the flexural strength was significantly decreased. 5. The decrement of flexural strengthes and the weight losses after 7 days immersion in acid or alkali solutions were not significant. 6. Fire resistance of the reclaimed plastic concrete was not significantly influenced by the contents of sand. However, the fire resistance of the reclaimed plastic concrete was depend upon melting and ignition properties of the binder itself. Therefore. a proper selection of the binder and the fire retardant are recommended in arder to improve fire resistance of the reclaimed plastic concrete.

  • PDF

A Study on the Properties of the Heavy Duty Rust-Converting Agent used in the Potential Hazard Areas of Fire & Explosion (잠재적 화재.폭발 위험 지역 작업용 녹전환형 중방식 코팅제의 특성에 관한 연구)

  • 강영구
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.3
    • /
    • pp.102-111
    • /
    • 1998
  • This study was concerned with the development of a heavy duty rust-converting agent, the function of which is to form metal complex coatings, containing vinyl halide-acrylic terpolymer emulsion, defoamer, emulsifying agent, glass flakes, chelating agent such as gallotannic acid, gallic acid, and pyrogallic acid, and other additives. The resulted emulsion products(Sample No.1~No.5) were characterized through test either in the forms of emulsions, which include Viscosity, Penetration rate, Acidity and Film drying rate test, or in the forms of coated layer on rusty steel substrates by FT-IR, which include hardness, gloss, salt spray, adhesion and flame retardant test. The test results are as follows ; Penetration rate(0.1~0.4 mm/min), Solid content(70%), Acidity (pH 1.8~2.0), Specific gravity(1.30~1.35), Film drying rate(108min, RH 40% ; 150min, RH 80%), Gloss(83~92, incident angle $60^{\circ}$; 88~97, incident angle $85^{\circ}$), Pencil hardness(4H~5H), Adhesion (100/100), Salt spray test(>720Hr), LOI(%) value(38%), Vertical burning test(UL 94-v-l). According to the various performance of specimens show above, the evaluation of the availability of this heavy duty rust-converting agent can be concluded that all the samples(No.1~No.5) are capable of being used in the field of chemical plant and in the hazard areas of fire and explosion potential. It was observed that the properties of sample No.2, especially gloss and hardness, were much better than that of the other samples.

  • PDF

Consideration of characteristic for nuclear power plant cables (원자력 발전소용 케이블의 제특성에 관한 고찰)

  • Kim, J.W.;Ahn, Y.K.;Park, I.G.;Paeck, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.609-611
    • /
    • 1993
  • Because the Nuclear power plant needs for the specific high stability and the confidence, it is required that cable shall be flame retardant at fire and endure to be exposed by radiation, chemical fluid, steam and high temperature at sudden accident condition and be maintained its capability on nomal operation up to 40 years as same as it's service life for Nuclear Power Plant. Consequently, In this report, we describe the terms of Environmental Qualification Test for cable and properties required for cable which developed for Nuclear Power Plant.

  • PDF