The Journal of the Convergence on Culture Technology
/
v.8
no.5
/
pp.641-651
/
2022
This research compares and analyzes evacuation time depending on the change in stair width in case of fire at Goshiwons. For this, a simulation has been conducted based on possible evacuation time according to the calculation method for the number of people admittable to a specific target for fire fighting equipped with accommodation. Currently, Gosiwon, which is classified as an accommodation facility (a total floor area of 500 m2 or more), uses blind spots prescribed by the Fire Services Act, Building Act, and Parking Act to build a high-rise building on a small area of land, and most Gosiwon is transformed into a modified accommodation. This is in line with the owner's operating profit, so it is expected to show a continuous increase. Securing the golden time of Gosiwon evacuation time is the last bastion of Gosiwon residents who belong to the economically disadvantaged in our society, and we hope this study will serve as a starting point for discussions on revising related laws and regulations to establish a social safety net As a result of the evacuation simulation analysis, the evacuation time was the least when the width of the group and the evacuation stairs were expanded to 200cm, and the evacuation time of the existing building was reduced by up to 166.3 seconds by comparing 648.4 seconds and scenario 6. This analysis can be meaningful, in that the width of the evacuation stairs revision of related laws and regulations for the safety of multiplex available premises.
Uniform laws and regulations and reasonable design is necessary for the prevention of possible fire in super high-rise building. To this end, this study focused on super high-rise and massive building-related architectural review performance-based design (PBD) evaluation disaster impact assessment (DIA), and provided fire engineering measures for improving fire prevention on the basis of performance-based design by analyzing the buildings subject to these systems and problems in terms of contents. Above all, in the aspect of law and standard improvement, first, with regard to dual parts of two statutes though significant portion of them has the same contents in performance-based design (PBD) evaluation and disaster impact assessment (DIA), it is necessary to operate the systems after making them conform with each other and consolidating or abolishing them. Second, if it is impossible to consolidate or abolish performance-based design (PBD) evaluation and disaster impact assessment (DIA), the areas of contents of performance-based design (PBD) evaluation and disaster impact assessment (DIA) should be precisely classified and established. Next, engineering improvement measures against fire hazard in super high-rise building are as follows. First, it is necessary to revise the provisions of straight-run stairs in special escape stairs. And in case of installing a mechanical smoke exhaust system instead of smoke vent, sandwich pressurization used in the United Stated should be permitted. Second, with regard to smoke control system for special escape stairs, it was shown that there was necessity for revising the standards in order to enable air to be supplied according to section in case of fire, carrying out performance-based design, and the like from the early design stages to the completion stages. In the future, it is expected that an epoch-making contribution will be made to a decrease in casualties and property damage due to fire in case of super high-rise building where the results can be reflected after carrying out a study on maintenance and carrying out an additional study on other considerations of super high-rise building together with reflecting the improvement measures provided in the above-mentioned study.
Purpose: Due to the coronavirus infection-19 (COVID) pendemics, all educational institutions were required to provide full non-face-to-face real-time education, and fire officials were required to provide fire-fighting education by applying non-face-to-face education. In this difficult situation, the National Fire Service Academy tries to find the direction of the non-face-to-face real-time education and suggest ways to improve it through a survey of the status of non-face-to-face real-time education conducted by the NFSA to fire officials. Method: A survey was conducted on fire officials under the theme of "Consciousness Survey for Improving the Quality and Specialization of Non-face-to-face Real-Time Remote Education" and an in-depth analysis was conducted based on the results. Result & Conclusion: First, professors or educational operators shall actively utilize remote education programs suitable for educational characteristics by utilizing various programs. Second, a dedicated notebook for non-face-to-face training should be provided to provide an educational environment where all learners can participate in the training without difficulty. Third, in the case of education and training that requires the use of equipment due to the nature of fire officials' education and training, it is necessary to consider it as a non-face-to-face training place by arranging educational equipment at each fire station. Fourth, it is hard to expect a satisfactory educational effect to cope with practical education with theoretical education. Therefore, facilities and programs that enable non-face-to-face real-time hands-on training should be developed. It is worth considering the proper combination of face-to-face education while maintaining the social distance as much as possible until such non-face-to-face training is possible. Fifth, non-face-to-face education is considered to have high eye fatigue due to the light and electromagnetic waves of the computer screen, and as time goes by, the concentration level decreases. Therefore, it is necessary to form an education time to reduce the eye fatigue of learners and increase concentration through proper class and rest time. Finally, professors should operate a learner participation-oriented education that allows professors and learners to interact rather than one-sided knowledge transfer education. In addition, technical problems of non-face-to-face remote education should be thoroughly prepared through preliminary system checks to ensure that education is not disrupted.
The Republic of Korean Navy (ROKN) started from scratch. However, ROKN demonstrated its Blue Navy capabilities successfully to the entire world by conducting "Operation Early Dawn" at the Aden Bay, Yemen in Jan 2011. On the event of the 70th anniversary of the ROKN, I would like to retrospect past gleaning from voyages and challenges we had in the past. At the very inception of the ROKN, Korean government as well as senior military leaders recognized that it had no time to spare to clean up military those were insinuated deeply by communist agents. It was the top priority of the government. The Mongumpo Operation which was not well known, conducted by ROKN was one of the clean-up drive. The Korean War sometimes called as "a fire from land put-off at the sea". The world famous "Incheon Landing" which reversed war situation from the Nakdong Perimeter also done by Sea Power. ROKN conducted various maritime operations including not only Incheon Landing, but amphibious operation at Hungnam, mine sweeping, sea convoy, Wonsan Withdrawal. On the same day of the Korean War started, 25th June 1950, unless the victory of the ROKNS Baekdusan (PC 701) at the Korean Strait, the waning lamp light of Korea could not be rekindled by the participation of the U.N. The ROKN rescued the 17th regiment of Korean Army from the isolation at the Ongjin Peninsular and transported gold and silver bars stored at the Bank of Korea to the Navy supply deposit in Jinhae safely. ROKN special intelligence unit conducted critical HUMINT which led Incheon Landing success. One of important mission ROKN conducted successfully was not only transporting war fighting materials but also U.S. provided grains to starving Koreans. ROKN participated Vietnam campaign from 1960s and conducted numerous maritime transportation operations supplying materials to Vietnam military forces along the long coastal lines. Experienced Naval Officers and enlisted men who discharged and acquired as merchant marine certificate supported most of the U.S. sea lift operations throughout the Vietnam campaign. ROK-US Combined Forces which had been honed and improved its war fighting capabilities through the Korean War and out of Vietnam jungle playing key deterrent against threat from north Korea. However, those threat level will be completely different when north Korea finish its nuclear weapon ambition. In order to stand firm against north Korean nuclear threat, I would like to expect strong political leadership supporting nuclear submarine for ROKN.
Journal of the Korea Academia-Industrial cooperation Society
/
v.19
no.5
/
pp.451-458
/
2018
This study was conducted to determine the association between quality of sleep (QOL) and the general characteristics, the health-behavioral factors, and the occupational characteristics of firefighting officers. The survey was conducted in October 2016 with a self-administered questionnaire using the Pittsburgh Sleep Quality Index (PSQI) developed by Pittsburgh University, targeting 600 male firefighting officers working at five fire stations in D city. As a result, the QOL of the study subjects measured by the PSQI revealed 13.2% to be good, and 86.8% to be poor. In relation to general characteristics and health habits, the rate of the group who had poor quality sleep was significantly higher in those with a lower subjective health status, in the non-smoking group, and in the low sleep-quality group, compared to the good sleep-quality group. For occupational characteristics, the rate of those with poor quality sleep was significantly higher in groups such as the fire suppression group, the shift work group, the hard physical labor group, the group with a lower sense of satisfaction in their work, and in the group classed as unfit for the job but who were not considering quitting their jobs, compared to their respective counterparts. Multiple regression analysis revealed factors of influence with explanatory powers of 24.4% for subjective health status, alcohol use, subjective quality of sleep, career, job position, and physical labor. The results of this study suggest that the quality of sleep for firefighting officers is significantly related to general characteristics, health-behavioral characteristics, and occupational characteristics.
Jo, Myung-Hee;Lee, Myung-Bo;Lee, Si-Young;Kim, Joon-Bum;Kwon, Bong-Kyum;Heo, Young-Jin
Journal of the Korean Association of Geographic Information Studies
/
v.7
no.2
/
pp.78-86
/
2004
Recently GPS and mobile GIS technologies based on LBS(location based service) have played an important role as DSS(decision supporting system) for domestic forest fire extinguishment policies. In this study forest fire extinguishments information management system based on mobile GIS technique was designed to seize the exact location on wireless network so that it helps to guide the safe and efficient extinguishments affairs and provide the extinguishments environment toward ground fighting teams and the central forest government in real time. Moreover, possibly to operate this system, the foundation technologies by the name of '.gci' such as the spatial data compression method, the spatial data transmission method over wireless network and the spatial analysis interface on PDA should be mainly considered. Especially, in this study the spatial data compression method having high compression rate from 51% to 62% for each polygon, line, and point data, without the loss of data was developed.
Background: Korean Red Ginseng (KRG) is widely used for strengthening the immune system and fighting fatigue, especially in people with deficiency syndrome. However, there is concern that the long-term application or a high dose of KRG can cause "fireness" (上火 in Chinese) because of its "dryness" (燥性 in Chinese). The aim of this study was to assess the safety and efficacy of a 4-week treatment with KRG in participants with deficiency syndrome. Methods: This was a 4-week, randomized, double-blind, placebo-controlled clinical trial. A total of 180 Chinese participants were randomly allocated to three groups: placebo control group, participants were given a placebo, 3.6 g/d; KRG 1.8 g and 3.6 g groups. The primary outcomes were the changes in fireness and safety evaluation (adverse events, laboratory tests, and electrocardiogram). The secondary outcomes were the efficacy of KRG on fatigue, which include the following: traditional Chinese medicine (TCM) symptom scale and fatigue self-assessment scale. Results: Of the 180 patients, 174 completed the full study. After 4 weeks of KRG treatment, the Fire-heat symptoms score including Excess fire-heat score and Deficient fire-heat score showed no significant change as compared with placebo treatment, and no clinically significant changes in any safety parameter were observed. Based on the TCM syndrome score and fatigue self-assessment score, TCM symptoms and fatigue were greatly improved after treatment with KRG, which showed a dose- and time-dependent effect. The total effective rate was also significantly increased in the KRG groups. Conclusion: Our study revealed that KRG has a potent antifatigue effect without significant adverse effects in people with deficiency syndrome. Although a larger sample size and longer treatment may be required for a more definite conclusion, this clinical trial is the first to disprove the common conception of "fireness" related to KRG.
Journal of the Korean Society of Marine Environment & Safety
/
v.17
no.1
/
pp.69-73
/
2011
Unlike land fires, Fires on board a ship are not likely to be extinguished by skilled human resources using a variety of fire fighting equipments, but have to be brought under control on board a ship itself despite of difficult task. There are more cases of deaths from suffocation by smoke than from an increased temperature by heat in fires on board ships, because crew fail to secure a sufficient visibility range enough to escape from the scene of a fire or to leave the ship as early as possible. On the assumption that the height of ship's accommodation area increases from 2.0m to 2.3m comparable to the height of apartments on the ground in Korea, behaviors of fire smokes between the cases of 2.0m and 2.3m heights were compared and analyzed. Based on the blue print of the existing Training Ship "Hanbada", a new blueprint with the 30 cm height adjustment was additionally created. FDS (Fire Dynamic Simulator), which was created by the NIST in the United States and is the most widely distributed simulator for fires, was used to conduct a simulation and predict results. The results of simulation on the basis of temperature of $60^{\circ}C$ showed a safe evacuation period of time at the position 10m apart from the scene of a fire to increase by 55.8 seconds, when the height of ship's accommodation area increased from 2.0m to 2.3m. The results of simulation on the basis of visibility range of 6m showed the safe evacuation periods of time at the positions 10m, 20m and 30m apart from the scene of a fire to increase by 27.1 seconds, 109.2 seconds and 73.3 seconds, respectively, as the height of ship's accommodation area increased from 2.0m to 2.3m. This means that crew can escape more safely from a scene of fires on board when the height of ship's accommodation area is increased and equal to the height of living room in a building on land.
Journal of Fisheries and Marine Sciences Education
/
v.29
no.3
/
pp.857-868
/
2017
The basic safety training for fisheries is being conducted to cope with an emergency situation and prevent the maritime accidents. A new joined person must be educated the safety training and a refresher must be completed the refresher training course every 5 year in according to the STCW-F and seafarers' Act. In order to achieve the objectives of marine safety training, it is necessary to distinguish the trainees by ship's type and the courses should be implemented in consideration of safety equipment of fishing vessels. However, since the classification criteria of seafarers' Act are unclear, the officer of fishing vessels which is over G/T 25 tons has been trained through the same course and curriculum for merchant ship's seafarers. About 80 % of domestically registered fishing vessels are small size ships(less than 100 tons) and there is not many safety equipment required by law. In case of marine accidents such as collision, the small vessel losses its buoyancy and stability caused by damage of hull. despite fisheries fall into the sea during fishing work in bad weather on the deck, there was no safety equipment by law. So fisheries must be trained by a safety training course suitable for fishing vessel. The purpose of this study is to develope the suitable course for fisheries by analysis current curriculum and rules. so suggested the basic safety training course for fisheries and institutional improvement.
The autotransformer currently used on the electric railway system is made of class A insulation material and uses the paper insulation method. As a power converter supplying power to the trolley wire, the autotransformer is one of critical equipment in the railway system. In the autotransformer, load irregularly changes and overload often occurs. These cause overheating of the autotransformer and facilitate deterioration of the autotransformer resulting in burnout accidents due to insulation breakdown. Also, the current autotransformer has poor insolation and short-circuit strength which often badly affect the service life of the transformer, and needs to improve its quality urgently. To overcome one of existing shortcomings of the mold transformer, manufacturers use epoxy resins that have superior flame retardancy to get rid of fro and explosion possibilities during accidents. Currently, new mold transformers are used in indoor distribution facilities with fire-fighting equipments. Coils molded in epoxy resins do not have their insulation performance compromised by humidity, dust, etc enabling easy inspection and maintenance. Comparing to the oil immersed transformer, the mold transformer does not have any concern about environmental pollutions by oil leak or replacement Therefore, to reduce breakdowns and improve reliability of the autotransformer, it is necessary to develop a new mold autotransformer with low loss suitable for our environment to suppress breakdowns of the autotransformer and improve the reliability. This study is about development of a low-loss mold autotransformer necessitated by reasons mentioned earlier.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.