A Study on the Systemic Improvement for the Enactment and Revision of the National Fire Safety Code (국가화재안전기준(NFSC)의 제·개정 시스템 개선에 관한 연구)

  • Song, Young-Joo;Kim, Tae-Woo;Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.110-119
    • /
    • 2020
  • The National Fire Safety Code (NFSC) sets forth the installation methods and technical standards of firefighting facilities. This information is stipulated in the attached Table 1 of the Enforcement Decree of the Act on Fire Prevention and Installation, Maintenance and Safety Control of Fire-Fighting Systems. The NFSC serves as a foundation for fire prevention and public safety. However, the current version of the NFSC has been under scrutiny due to its delayed enactment and revision process. This is because of its structural inflexibility, time-consuming procedures, and mixed usage of both performance and technical standards. Furthermore, there are difficulties with keeping its unique specialties due to the absence of a specialized, permanent independent entity that enacts, revises, and maintains its standards. Moreover, the NFSC lacks collectivity, openness, and consistency. Therefore, to overcome the aforementioned obstacles, this study investigates the operational and legal status of the NFSC and the problems regarding its enactment and revision process. Further, it presents suggestions for system improvement by analyzing and comparing the information with domestic and foreign counterparts dedicated to managing their similar technical NFSC standards. First, the study recommends that the legal performance and technical standards mixed within the current NFSC should be separated. Second, the enactment and revision of technical standards should be implemented by the private sector and not by the government. Third, technical standards should adopt a user-oriented approach for the code system.

Study on the Deep Stead Fire Spread Temperature by the Change of the Wood Flour Density (목분의 밀도변화에 따른 온도전이에 관한 실험적 연구)

  • Kim, Jin Su;Rie, Dong Ho
    • Fire Science and Engineering
    • /
    • v.29 no.3
    • /
    • pp.1-5
    • /
    • 2015
  • The productivity and demand of porous material has been increasing by development of industry and increasing income. In particular, the fire caused by using wood flour risks wood processing industry and stock farm. The heat transfer of wood flour is carried into the depth direction by effect of oxidizer around flame, flame sometimes is progressed as smoldering. In the case of progressing as combustion fire, identifying the location of fire is difficult, and it leads to failing fire aid fire fighting. Therefore potential cause is acted as raising additional damage. This paper conducts experiments of downward deep seated fire of natural convection conditions. The samples is New Zealand wood flour that is demanded much in the domestic and oversea market. In this experiment, temperature of deep seated side is measure by changing wood flour density in holder The densities used in experiment are 3%, 5%, 10%, 15%. As a result, the tendency of temperature inside decreases as wood flour density increases. But, in the case of density which is above $0.2140g/cm^3$, the phenomenon, decreasing temperature, is not shown. The result of measurement show that average flame spread speed of wood flour is 0.249 mm/min.

A Numerical Study to Analyze Safety of Pressure Leakage Monitoring System of Gas Extinguishing Agent (가스소화약제 압력누기감시장치의 안전성 분석을 위한 수치적 연구)

  • Go, A-Ra;Lim, Dong-Oh;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.103-110
    • /
    • 2016
  • While the demand for the gas system fire extinguishers increases every year, there are insufficient safety measures for assessing the extinguishing performance, such as system safety and reliability in the preparation of increasing demand, which has emerged as a social problem. One of the most critical causes of accidents occurring with the gas extinguishing system is pressure leakage from the extinguishing agent storage container. This is considered to be one of the critical factors on which the success of fire suppression depends. In this study, its safety measure was studied, Because it was deemed urgently necessary. The newly developed pressure leakage monitoring system is a system monitoring storage condition, pressure, leakage and discharge of the storage container related to agent concentration, which is one of the critical factors for fire suppression. This was developed to be applicable to the $CO_2$ and HFC-23 systems. Therefore, for structural safety analysis, the safety performance was verified by the fluid structure coupling analysis of the safety problems that may occur when the pressure leakage monitoring system is applied to the gas fire extinguisher. For analysis programs, the FloEFD program from Mentor Graphics was used for computational fluid dynamics analysis and ABAQUS from Dassault Systems was used for structural analysis. From the result of numerical analysis, the structure of $CO_2$ did not develop plastic deformation and its safety was verified. However, plastic deformation and deviation issue occurred with the HFC-23 monitoring system and therefore verified the structural safety of pressure leakage monitoring system by data obtained from redesigning and adjusting the condition of numerical interpretation three times.

A Study on Required Safe Egress Time (RSET) Comparison and Error Calculation in Relation to Fire Room Range Set Conditions of Performance Based Fire Safety Designers (성능위주설계자들의 화재실 범위 설정 방식에 따른 소요피난안전시간(RSET) 비교 및 오차산정에 관한 연구)

  • Baek, Sona;Choi, Jun-Ho;Hong, Won-Hwa;Jung, Jong-Jin
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.73-78
    • /
    • 2016
  • The Installation, Maintence, and Safety Control of Fire-fighting Systems Act of South Korea regulates that over 30-storey high-rise buildings including underground spaces should vitally perform the Performance-based Design to minimize property damage and personal injury as a fire risk assessment in advance. Therefore a PBD designer such as a fire safety professional engineer evaluate occupant's life safety by a scientific methodology. In order to evaluate the life safety, fire safety designers calculate the Required Safety Egress Time (RSET) which does not have the legal criteria regarding the standard method of calculation yet. So this way has been showing different results depending upon the designer's choice, knowledges and experiences. In this study, RSET calculation methods by six designers respectively were analysed from the thirteen reports of real performance based design projects conducted in Busan for a last five years. In particular, the Response Time calculation methods which have the most powerful effect for figuring the RSET are compared with the other designer's to deduce an error value.

Validation of Inside Design Safety for the 119 Ambulance using a Structural Analysis (119 구급자동차의 구조해석을 통한 내부 설계 안전성 검증에 관한 연구)

  • Shin, Dong-Min;Kim, Hyung-Wook;Han, Yong-Taek
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.123-132
    • /
    • 2016
  • This study is the result of performing structural analysis in accordance with the new ambulance design of inside space using the new vehicle's bodywork. 3D design works were performed based on international standards and designed ambulance. And then it was tested by a shock of 10G to the ambulance car inside with respect to the vehicle body after that we looked into the consequences. At this time, it was carried out in consideration of its own weight and the weight of components according to the EN regulation. From the result of structural analysis, the internal frame and configured handrail in a variety of pipe did not have a relatively large stress load, but internal panel and cabinets has been interpreted to receive a large stress load at least over 50 MPa. When carried out reinforcement design in accordance with this analysis, the modification of thickness and shape could be necessary. On the basis of these findings, it is also expected that there could be a useful information to produce a more secure vehicle for paramedics and patients using a ambulance inside the vehicle.

A Study on the interface of information processing system on Human enhancement fire fighting helmet (휴먼 증강 소방헬멧 정보처리 시스템 인터페이스 연구)

  • Park, Hyun-Ju;Lee, Kam-Yeon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.497-498
    • /
    • 2018
  • In the fire scene, it is difficult to see 1m ahead because of power failure, smoke and toxic gas, even with thermal imaging camera and Xenon searchlight. Analysis of the smoke particles in the fire scene shows that even if the smoke is $5{\mu}m$ or less in wavelength, it is difficult to obtain a front view when using a conventional thermal imaging camera if the visual distance exceeds 1 meter. In the case of black smoke with a particle wavelength of $5{\mu}m$ or more, a space permeation sensor technology using various sensors other than a single sensor is required because chemical materials, gas, and water molecules are mixed. Firefighters need a smoke detection technology for smoke detection and spatial information visualization for forward safety view.In this paper, we design the interface of the information processing system with 32bit CPU core and peripheral circuit. We also implemented and simulated the interface with Lidar sensor. Through this, we provide interface that can implement information processing system of human enhancement fire helmet in the future.

  • PDF

Study on the Improvement of a Special Fire Police Judicial Police System (소방특별사법경찰제도의 문제점에 따른 개선방안 연구)

  • Park, Hyeong-Jin;Kim, Jung-Rae;Kim, Jong-Buk;Cha, jin;Kwon, Hyun-Seok;Lee, Si-Young
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.77-86
    • /
    • 2018
  • In recent years, the high growth of the Korean society has led to the development of large and small incidents and accidents, while safety regulations, such as the firefighting sector, have been strengthened with the expectation of people desiring safety. This study surveyed the problems and improvement plan of the current operation centered on the fire service public officers in Gyeonggi-do and Gangwon. As a result of the main research, it is necessary to arrange and carry out excellent investigative manpower, such as lawyers and professional career veterans in the fire department, metropolitan city and provincial firefighting headquarters, and frontline fire departments. In particular, it was suggested that a special task force should be established and set up in the above agency, and the planning investigation and enforcement work should be solved through subdivision of the fire special enforcement officer tasks, and the judicial cases that are difficult to be handled by the local fire station. In future research, it will be necessary to study the field of fire - fighting specialists' needs for more specialized education and various disaster field experiences.

A Study on the Safety-related Criteria for the Interior Space Planning, Facilities and Fire-fighting Equipment in Child Care Centers (보육시설의 실내공간계획 및 설비와 소방설비의 안전성 관련 기준에 대한 연구)

  • Rhee, Jisook
    • Journal of Families and Better Life
    • /
    • v.31 no.6
    • /
    • pp.39-51
    • /
    • 2013
  • Because of the increasing demand for day care centers, The Korean government has enforced childcare accreditation. The government has created the evaluation certification system for child care facilities. But the system includes variable items, and the physical rules are not sufficient for ensuring security and quality amenities. So this study, through literature search, examined the rules of Child Care Centers in the U.S. and compared them with those in Korea focusing on the provision of security and amenities. The standards found in 4 U.S. states were investigated, and the results are as follows. The rule pertaining to the size of indoor activity spaces in C.C.C. allows the spaces to be smaller in Korea than in the U.S. There is no specific criterion for infants and toddlers in our standard. When comparing the standards of Korea with those of the United States, Korea's standards do not state specific rules about child care facilities such as indoor furniture, finishes and space planning. Additionally, the binding force ensuring compliance with the standards of physical facilities is weak. Thus, the ratings of child care standards for the physical environment should be presented in detail. And if a center does not comply with the criteria, stronger penalties will have to be imposed.

A Study on the Factors Affecting the Safety Awareness of Foreign Workers & International Students (외국인근로자와 유학생의 안전의식에 영향을 미치는 요인)

  • Park, Sunah;Lee, Jai Young
    • Journal of the Korea Safety Management & Science
    • /
    • v.24 no.2
    • /
    • pp.87-96
    • /
    • 2022
  • The purpose of this study is to analyze which factors affect safety awareness of foreign workers and international students. In the correlation analysis, individual characteristics related to the safety awareness of foreign workers were nationality, status of stay(visa types), place of work, educational background, and Korean proficiency while international students were relevant with only the types of residence. There were significant differences in the safety awareness of foreign workers in nationality, status of stay(visa types), region of residence, educational background, place of work, and Korean proficiency. However, there was a significant difference only in the types of residence for the international students. In the regression analysis of factors affecting safety awareness, there were significant differences in nationality, status of stay(visa types), place of work, and Korean proficiency in the case of foreign workers. It was analyzed that nationality and status of stay had a negative (-) effect, and the place of work and Korean proficiency had a positive (+) effect. In the case of international students, it was analyzed that only the types of residence had a negative (-) effect on safety awareness.

Analysis of the Evacuation Safety in a Fire at Welfare Center for Disabled (장애인복지관 화재 시 피난안전성 분석)

  • Park, Sunah;Lee, Jai Young
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.12
    • /
    • pp.315-322
    • /
    • 2021
  • This study analyzes the Required Safe Egress Time (RSET), in the event of a fire at a welfare center for the disabled, using the emergency passage according to the floor arrangement of users to evaluate the safety and the difference in RSET for each emergency passage using the Pathfinder simulation program to suggest an efficient evacuation method. As a result of RSET, it was found that there is no problem in evacuation safety for the current state of the facility's personnel allocation by satisfying the standard RSET in case of fire, and evacuation can be completed safely by evacuating through stairs rather than using elevators if possible. It is necessary for employees to be provided sufficient education and training in advance so that they can evacuate effectively with the disabled in case of fire. This study gives significance in saving many precious lives and safely evacuate in case of fire as evacuation routes were secured through the design, construction and operation of facilities for the disabled and the RSET was shortened through regular evacuation practices. It is necessary to discuss the further RSET studies based on the automatic fire shutters open or not when a fire occurs at a specific location following the installation of automatic fire shutter at the entrance of each floor of the facilities.