• Title/Summary/Keyword: fire-fighting

Search Result 488, Processing Time 0.025 seconds

Direction of Fire Safety Development through Analysis of Previous Firefighting-Related Research (소방분야 선행연구 분석을 통한 소방안전 발전방향)

  • Jeong, Mu Heon;Lee, Sun Jai;Park, In-Seon
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.103-108
    • /
    • 2019
  • The purpose of this study is to suggest the development direction of fire safety through the analysis of previous researches in the field of fire fighting. To this end, 929 papers published in the Journal of Korean Institute of Fire Science and Engineering have been sorted by field of study and analyzed for frequency. Accordingly, it was confirmed that researches were conducted in the order of fire chemistry and physics, detection and extinguishing system, fire safety design and management, evacuation and human behavior. In contrast, very little research has been conducted on human behavior, fire safety education, or training. This result is discussed in the article, and suggestions for future research objectives are made.

Study of the Real Condition and Improvement Plans of a Fire Protection System Installed at Museum Storage (수장고에 설치된 소방시설의 실태 및 개선방안에 관한 연구)

  • Park, Jong-A;Joo, Seung-Ho;Kang, Eun-Soo;Lee, Dae-Keon
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.60-66
    • /
    • 2018
  • Museum storage has been a unique area for experts, such as curators and managers etc., is a part that requires attention among the recent changes in museums because of changes to a type that is being opened gradually to visitors. On the other hand, there is an increased the risk of a fire according to negligence etc. of visitors. Hence, appropriate measures for a fire protection system to respond to varying museum storage are required. This study examined the status of fire protection systems applied to museum storage visiting 40 domestic public museums with the support of the Ministry of Culture, Sports and Tourism, and a direction to install a fire protection system was presented by drawing cases of fire protection systems with less adaptability or poor management or excellent fire protection systems, and a direction for improvement was presented.

Case Studies of Firefighter Burns Safety Accident during Fire-fighting Activities (현장 소방활동 중 소방공무원 화상사고 사례 분석 연구)

  • Sin-woong, Choi;So Yun, Lee
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.6
    • /
    • pp.136-147
    • /
    • 2022
  • The purpose of this study is to analyze four cases of firefighter burns in various fire scenes and to find prevention measures to decrease firefighter injuries. Among the analysis reports prepared by the National Fire Research Institute of Korea from 2016 to 2020, four burn-related accidents are summarized and the main causes are conveyed. The four accidents include second-degree burns from using extinguishers during containment of fires; nine firefighters burned due to re-ignition in the LPG car repair shop; two firefighters injured with third-degree burns from using fire extinguishers during life-saving events in residential housing; and injuries from the radiant heat of the tank BLEVE near the factory fire. These cases are comprehensively investigated in their respective scenes and analyzed based on the fire site investigation reports from the fire department and related theoretical explanations of risk for each accident scene. In the third case study, some experimental research is conducted to evaluate the risk involved with the use of safety gloves. This is evaluated by reviewing Fire Tactics and Standard Operational Procedures (SOP) to determine improvements and recommendations for an efficient firefighting response. Results show that the main causes of burn accidents are the insufficient use of personal protective equipment (PPE), such as safety gloves, and the failure to follow firefighting tactics or SOPs. Through the accident investigation and assessment, it is concluded that to reduce the frequency of burn accidents, the performance of firefighting equipment, SOPs, protection tactics, and safety policy systems require improvement.

A study on the design of a general-purpose automatic fire detection system based on a private wireless network of the fire fighting communication frequency band (소방통신 주파수 대역 자가 무선망 기반 범용 자동 화재 탐지 시스템 설계를 위한 연구)

  • Kim, Minyoung;Choi, Donggyu;Jang, Jongwook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.246-248
    • /
    • 2021
  • This paper proposes a new general-purpose automatic fire detection system. And it deals with the contents of related research on how to design and develop for this system. The proposed system automatically notifies the user and the nearby fire department when a fire breaks out in a place where a fire alarm is installed. If this is the case, the nearby fire department can quickly confirm this fact and extinguish the fire at an early stage, thereby reducing human and property damage. The main targets of this system are houses and small buildings. The proposed fire alarm functions as a conventional fire alarm, and if a fire occurs, this fact is immediately transmitted to a nearby receiver through wireless data communication. The receiver in this paper communicates data using Korea's firefighting communication frequency band, and establishes one own network by installing it in various places to quickly receive fire alarm data at any time.

  • PDF

The Analysis on the Soongrae-Mun fire and it's improvement measure (경비업무적 관점에서의 숭례문화재사고 분석과 대책)

  • Chung, Tae-Hwang;Lee, Choong-Soo
    • Korean Security Journal
    • /
    • no.16
    • /
    • pp.321-338
    • /
    • 2008
  • Soongrae-Mun Fire shows safety problem in Korea intimately. People have pressed for the responsibility of persons in charge and have asked for improvement measure whenever Fire accident occur, but similar accidents occur again without any improvement. This research is to provide improvement. measure on the base of the analysis of the cause of Soongrae-Mun fire to prevent similar accident, also to help private security company do effective security job. This research is approached from a security point of view. A lot of accidents occur by direct cause such as people's unsafe action and unsafe condition. but it is very difficult to remove the facts of direct cause, so the facts of indirect cause should be analyzed together. Drew-up of security related legislation should be included when the establishment of fire fighting related legislation is examined, also technical improvement should be examined with legislation. security company should be concerned about securing of expertise and reinvestment for the improvement of expertise to overcome limitations of private security such as job boundary, capability and responsibility. Also private security company should try to service for public benefit and to examine practical compensation for loss occurred by mistake of security company.

  • PDF

A Study on Risk Assessment of extreme Cold Waves in Energy Storage Facilities According to Climate Change (기후변화에 따른 에너지 저장시설 극한 한파 위험성 평가에 관한 연구)

  • Han-Duk Kim;Eun-Gu Ham;Se-Young Ko
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.3
    • /
    • pp.584-592
    • /
    • 2024
  • Purpose: The biggest concern in cold wave situations is that the fire extinguishing water initially supplied through dry pipes with empty pipes consumes enthalpy and freezes as it rapidly approaches the surface temperature of steel pipes that have been exposed to sub-zero outdoor air for a long time. It has no choice but to be. Method: Therefore, the study found that ice crystals were generated during transport, making it difficult to transport fire extinguishing water, and as a result of the review, when the heat load passed through the piping material, the heat loss per unit length from the piping to the surroundings was 0.946. Results: When calculating the volume of the main pipe, it was calculated that the fire extinguishing water supplied at a temperature of 15 degrees from the underground pipe would have a volume of 3.33m3 to reach the first branch point. If we calculate the heat required until this volume reaches below zero, we get 316.350 kcal. When the results were reviewed using the related formula, the time required for the fire extinguishing water to completely freeze up to the first branch of the steel pipe was found to be 3,412 seconds. Conclusion: Fire-fighting water, which must reach from the main pipe to the branch pipe and nozzle in good condition, must minimize heat loss through the pipe surface along the transfer path. To achieve this, it is necessary to supplement insulation of the main pipe and branch pipes. In this study, the use of inorganic perlite material or flame-retardant rubber foam insulation was proposed through analysis of insulation properties.

A Study of Fire Extinguishment Characteristic for the Real Scale Deap-Seated Fire (실규모 심부화재 소화특성에 관한 연구)

  • Kim, Nam-Kyun;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.13-19
    • /
    • 2015
  • Real scale fire tests was carried out for extinguishing performance evaluation of the wetting agent. The experiment was conducted in accordance with a Class A fire extinguishing test methods specified in the 'Type Approval of the Manual System Fire Extinguisher and Technical Standards of Test'. In addition, the subjects of this experiment were the wood flour and rice husk. Fire-fighting water, the three kinds of wetting agents used in the country and this study was used, was undertaken to determine a clear discrimination of the water and wetting agent. In the experimental results, it was confirmed that the internal temperature is maintained long time in the case of water. The internal temperature were rapidly lowered in the experiment of wetting agents. Therefore, the discrimination of extinguishing ability was confirmed by the temperature distribution in accordance with time. Based on the results of this experiment, this study is expected to be used as a underlying material on presenting a method of optimized performance evaluation of wetting extinguishing agent.

Analysis on Factors that affect Fire Safety R&D Performance - Focused on the Field-oriented Support of Fire Fighting Technology R&D Program - (소방안전 R&D 성과에 영향을 미치는 요인 분석 - 현장중심형 소방활동지원 기술개발사업을 중심으로 -)

  • Lim, You-Ri;Shin, Young-Min;Ahn, Yong-Han
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.171-178
    • /
    • 2019
  • The disaster and safety R&D budget has continued to increase since 2008, but the fire safety R&D budget is a small part. Therefore, successful outcomes that could lead to the economic growth of the fire safety industry have not been achieved. This paper suggests a fire safety R&D budget expansion, reinforcement of R&D capacity, and performance growing plan by analyzing the factors that affect the performance of a fire safety R&D project. Empirical analysis was performed through one-way ANOVA and regression analysis using the statistical program, SPSS statistics 21.0. As a result, this study suggests that the continuous expansion of R&D funds and the securing of excellent trained research manpower will be necessary to obtain qualitatively superior patents and papers.

Synthesis and Surface Activities of Perfluoro Hetero Type compounds (헤테로형 불소계 소화약제의 물리적 특성에 관한 연구)

  • 이승열;박노춘
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.1
    • /
    • pp.64-69
    • /
    • 1998
  • Three kinds of N-fluoroacyl carboxy pyridinium chlorides were synthesized by the reaction of pyridine-carboxylic acid such as pyridine-2-carboxylic, pyridine-3-carboxylic and pyridine-4-carboxylic acid with long chain perfluoroacyl chloride. The surface chemical properties including surface tension, foaming power, foam stability, effectiveness of wettability and solubilizing effect were measured. These compounds showed good surface activities as emulsifying agent, solubilizing agent and fire-fighting agent.

  • PDF

A study on the implementation of tele diagnosis and repair on fire-fighting system using HTTP network (인터넷망을 이용한 소방설비 시스템의 원격 진단 및 고장수리의 실현에 관한 연구)

  • 김광태;정수일
    • Journal of the Korea Safety Management & Science
    • /
    • v.4 no.1
    • /
    • pp.27-36
    • /
    • 2002
  • This paper describes "the remote automatic diagnosis and repair system which automatically reads the problems such as "out of order" occurred on equipment at customer's equipment from a remote computer center using HTTP(hyper text transfer protocol). It shows the scheme of the network configurations and features of the system. In addition, a way to implement the overall system, the specific functions of unit, and the operational specifications between the center's computer and customer's computer are also presented.also presented.