• Title/Summary/Keyword: fire-fighting

Search Result 488, Processing Time 0.027 seconds

Namsan 1.2.3 Tunnel accident disaster countermeasures (남산 1·2·3호 터널사고에 대한 재난대응방안)

  • Lee, Jeong-Il
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.1
    • /
    • pp.69-75
    • /
    • 2013
  • Namsan road are taxis in the engine room fires (07/14/2011 18:05) in the tunnel, and the driver of the vehicle was 100 passenger car and more than 500 evacuated were disasters. Pole road vehicles within the tunnel if there is a fire tunnel fire occurred at a two-way evacuation difficult and rapid evacuation is difficult and mass casualties are concerned, the number of casualties is feared. In this study, by considering the problems and improve the Namsan 1,2,3 Tunnel In case of fire, the best disaster response is to come up with ways.

Analysis of the Helicopter Fire Attack Pattern on Forest Fire Behavior (산불진화 헬기의 물 살포유형 분석에 관한 연구)

  • Lee, Si-Young;Bae, Taek-Hoon
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.96-100
    • /
    • 2009
  • Because of dense forests and restriction of approaching for fire fighters, forest fire is easy to be a larger fire in Korea. For this result, the air attack was about 90% of extinguishing, so the application of aircrafts, especially helicopters, will be increased gradually. In the all process of forest fire attack, the method of heli-scattering water was the chief element of success of efficient forest fire attack and safe flight. Therefore, a standardized method of heli-scattering water was required. However, as it was not already standardized, a efficiency and safety of fire fighting have been decreased. In this study, we suggest a 11 patterns of methods for scatterling water based on a actual experience of air attack.

Study on Theoretical Research to Reduce Fire Risk of Solar Power System (태양광 발전 시스템의 화재 위험 감소 방안에 관한 이론적 연구)

  • Park, Kyong-Jin;Lee, Guen-Cull;Lee, Bong-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.2_2
    • /
    • pp.219-224
    • /
    • 2020
  • This study is based on the principle of solar power system and fire breakout. The result of the survey indicates that a solar power system is vulnerable to fire due to lack of maintenance after the installation. Currently the national fire safety agency does not have standards and legal provisions for the installation and maintenance of solar power facilities. Therefore, it increases the risk of fire breakouts as well as possibility of electric shock for the firefighters during fire fighting. This results possible damages to the human and equipments. In this study is proposing an automatic fire extinguishing system to reduce the power generation of solar panels during fire breakouts. Also, propose an over load current alarm system and fire prevention measures for fire fighters. The results of this study will be used as basic data for further fire testing of solar power systems.

A Study on the Recognition of Effectiveness and Safety of the Helicopter Aerial Fire Attack (헬기에 의한 산불공중진화 효과 및 안전성 인식 연구)

  • Bae, Taek-Hoon;Lee, Si-Young
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.97-104
    • /
    • 2012
  • Forest fires were easy to be larger in Korea. So the utilization of aircrafts, especially helicopters, for forest fire attack would be increased gradually. In the forest fire attack process, the improvement of the helicopter aerial fire attack technique and safety were the chief element for efficient forest fire attack. In this study, we surveyed the recognition of pilots who worked in Forest Aviation Office which was responsible for aerial forest fire attack in Korea. Using these survey results, we suggested more efficient and safer method for aerial fire fighting based on actual experience of air attack at the scene of forest fire burning.

Concept Design of Fire Safety Module for SV20 Service in the Korean e-Navigation System

  • Kim, Byeol;Moon, Serng-Bae;Hwang, Kwang-Il
    • Journal of Navigation and Port Research
    • /
    • v.42 no.5
    • /
    • pp.323-330
    • /
    • 2018
  • The Korean e-Navigation system is a Korean approach to correspond with implementation of IMO e-Navigation. It provides five services, among them SV20 service, a ship remote monitoring system that collects and processes sensor information related to fire, navigation, and seakeeping performance safety. The system also detects abnormal conditions such as fires, capsizing, sinking, navigation equipment failure during navigation, and calculates the safety index and determines the emergency level. According to emergency level, it provides appropriate emergency response guidance for the onboard operator. The fire safety module is composed of three sub-modules; each module is the safety index sub-module, the emergency level determination sub-module and emergency response guidance sub-module. In this study, operational concept of the fire safety module in SV20 service is explained, and fire safety assessment factors are estimated, to calculate the fire safety index. Fire assessment factors included 'Fire detector position factor,' 'Smoke diffusion rate factor,' and 'Fire-fighting facilities factor.'

A Study on the Reformation of Certified Fire Fighting Specialists - Focused on Fire Protection System Managers - (소방전문자격사제도의 개선에 관한 연구 - 소방시설관리사를 중심으로 -)

  • Oh, Hyeong-Geun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.4 s.23
    • /
    • pp.21-28
    • /
    • 2006
  • This research analyzed the operational status of fire protection system managers who execute self inspection of the fire equipment in the specific fire protection facilities and presented the improvement scheme. Being made up inquiry for job environment, institutional environment, and operational environment for the subject of fire protection system managers who execute self inspection to complement the fire equipment inspection by city public fire protection service, the issues of the operational status of the institution of fire protection system managers were positively understood. The research result showed the conflict among building owner, fire equipment inspector, and fire protection system manager was existed due to the legal and institutional inertia to the self inspection, so it is judged that mutual complementary and cooperative relation should be established.

The Study of Fire Detector Circuit with Wireless Communication (무선통신기능을 갖는 화재감지기 회로에 대한 연구)

  • Baek, Dong-Hyun;Kim, Jang-Won
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.111-115
    • /
    • 2010
  • For the development of fire detector equipments that was fused independent type of fire detector and a wireless communication function, this paper adopted a signal processing method of an independent formation fire sensor by a ZigBee communication method, and it was designed that the combinations of fire detector and wireless communications network were enabled. When a fire occurred, output voltage of a fire detector was 0.4 V, the movement pulse width was $600{\mu}s$, and that was confirmed by an experiment. When it has lookout state, LED worked by 30 s cycle and working current is 0.12 mA. When a fire occurred, LED worked by 0.5 s cycle and working current was 7 mA, and through this experiment of power source, Chamber tester, smoke tester,IRED, LED lighting, the propriety of the method that we showed in this paper confirmed.

A Study on the Basic Ideas for Fire Fighting Prevention System in Traditional Folk Village - Focused on Oeam Folk Village in Asan - (전통민속마을 소방방재 기본구상 - 아산 외암민속마을을 중심으로 -)

  • Lee, Jeong-Soo;Lee, Wang-Kee;Oh, Kyu-Hyung;Shin, Kyo-Young;Kwon, Heung-Soon
    • Journal of architectural history
    • /
    • v.19 no.1
    • /
    • pp.71-90
    • /
    • 2010
  • This research has set up the fire protection and early suppression plan for Asan Oeam folk village which is composed of traditional wooden building instinct or complex. The results of this study are as follows. 1. The traditional wooden buildings require attentive considerations about the fire property of the Waga and the straw roofed house. Especially, as the straw roofed house has property that the transfer and development of the fire is fast. Therefore we studied on the transferring possibilities of the fire dangerous instinct through measuring the distance from of the eaves edge and trees in neighboring house. 2. This research proposes the tools for the priority protective building through consideration of fire risk and cultural priority because the fire prevention for all is impossible at the same time. 3. The most important thing is preserve the cultural identities of traditional folk village in establishing the fire hydrant and fire prevention facilities. Traditional folk village landscape should be considered.

he Influence of Posttraumatic Stress on Suicidal Ideation in Firefighters : Cognitive Emotion Regulation as a Moderator (소방공무원의 외상 후 스트레스가 자살생각에 미치는 영향 - 인지적 정서조절의 조절효과-)

  • Kim, Sung-Jung;Yook, Sung-Pil
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.92-101
    • /
    • 2018
  • This study investigated the impact of post-traumatic stress of the fire-fighting officers who are exposed to traumatic events repeatedly on suicide and attempted to verify the moderating effect of cognitive emotion regulation in the relationship between post-traumatic stress and suicidal ideation. For this investigation, this study measured Post-traumatic stress Diagnostic Scale, Korean Beck scale for Suicidal Ideation, Cognitive Emotion Regulation Questionnaire. The research results are as follows. First, Post-traumatic stress, suicidal ideation, adaptive cognitive emotion regulation, and maladaptive cognitive emotion regulation were correlated. second, A hierarchical regression analysis was conducted in order to examine the moderating effect of cognitive emotion regulation in the relationship between post-traumatic stress and suicidal ideation, and as a result, it was found that a sub-factor of cognitive emotion regulation, adaptive cognitive emotion regulation had a moderating effect in a group of persons with low post-traumatic stress, while maladaptive cognitive emotion regulation had a moderating effect in a group of persons with high post-traumatic stress. These results, this study discussed the necessity of follow-up studies, in addition to its academic and clinical implications.

A Study on The Awareness of Fire-Fighting Officer for Strengthening Capabilities of Disaster Response System (재난현장 대응체계 역량강화를 위한 소방공무원 의식조사 연구)

  • Woo, Jaebong;Shin, Hojoon;Baek, Minho
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.3
    • /
    • pp.276-281
    • /
    • 2013
  • This thesis grasped problems by examining the current status of disaster response system repeated during the disaster according to the changes of social environment and suggested current status of disaster response system and developmental measures through the investigation of the awareness of fire-fighting officer. On disaster site, close cooperation system of disaster safety measure headquarter and urgent rescue controlling association must be formed and range and time of the action must be accurately improved so as not to cause duplication of rights for orders. Also, systematic education and training system must be established so as to strengthen disaster site reaction capability and manpower and equipment for it must be increased. Finally, detailed measures for improving initial reaction capability during the disaster, such as tactic development, reaction plan establishment, etc, are requested.