외부화염에 의한 드라이비트의 소손패턴 연구 (A Study on the Damaged Pattern of Dryvit by External Flame)

  • 박영주;홍이표;이해평
    • 한국안전학회지
    • /
    • 제30권6호
    • /
    • pp.40-47
    • /
    • 2015
  • In this study, temperature characteristics and fire damage form were analyzed to investigate flame spreading form and fire probability from ignition sources subject to drivit component materials which is finishing material in architecture. Ignition sources were limited to a gas torch and exterior panel board fire, and the size of the sample was manufacture in 30 cm length ${\times}$ 50 cm height ${\times}$ 5cm thickness size. Marble (inner wall) + 3 mm drivit (outer wall), marble (inner wall) + 4 mm plaster stone (outer wall), sandwich panel + 3 mm driver bit (outer wall), sandwich panel + 3 mm driver bit + insulation (outer wall), and gypsum board (inner wall) + 3 mm drivit (outer wall) were prepared for the sample. As result of the research for temperature characteristics, large temperature difference by each material was shown in $218^{\circ}C{\sim}995^{\circ}C$ at 30 seconds and $501^{\circ}C{\sim}1078^{\circ}C$ at 300 seconds. Especially when the inner wall was a plaster board, lowest temperature of $501^{\circ}C$ was shown at 300 seconds and marble inner wall showed the following lowest temperature of $900^{\circ}C$. Temperature rising over $1000^{\circ}C$ was shown in other materials. Regarding fire damage form, drivit or gypsum board outer wall parts exposed to fire showed combustion and carbonization to show calcination(breaking phenomenon) and influence of heat exposure was higher as calcination became more severe.

온도가열곡선 변화에 따른 콘크리트의 내화특성 (Properties of Fire Resistance in Tunnel Concrete According to the Changes of Heating Curve)

  • 배장춘;노상균;이찬영;이종석;이장화;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.705-708
    • /
    • 2008
  • 본 연구에서는 화재시 터널 콘크리트의 안전성 확보를 목적으로, 내화공법 변화에 따른 내화특성을 분석한 것으로서, 그 결과를 요약하면 다음과 같다. RABT온도가열곡선에 따른 내화특성으로, 플레인 콘크리트는 초기의 극심한 고온에 의해 심한 폭렬현상이 발생하였고, 내화공법변화에 따라서는, 유기섬유를 혼입하는 방식과 보드방식의 경우는 폭렬이 방지되는 것으로 나타났으며, 스프레이 방식의 경우는 보강재인 메탈라스가 뿜칠재와 같이 탈락되면서 열응력 등에 의해 구조체 콘크리트가 철근이 노출되는 등 100mm이상 깊이의 심한 폭렬이 발생하였다. RWS 온도가열곡선에 따른 내화특성으로, 유기섬유를 혼입한 경우는 콘크리트 표면이 약 5mm이내 깊이의 융해현상이 발생하였고, 스프레이 방식의 경우는 뿜칠재가 박리되어 구조체 콘크리트가 철근이 노출되는 등 100mm이상 깊이의 심한 폭렬이 발생하였으며, 보드방식의 경우도 보드가 고온에 융해되면서 구조체 콘크리트가 고온에 직접 노출되어 전면적으로 탈락현상이 발생하였는데, 이와같은 특고온 가열조건에서는 특별한 내화대책수립이 필요한 것으로 사료된다.

  • PDF

터널 풍도슬라브에 사용된 내화패널의 적용성에 관한 실험연구 (An Experimental Study on the Application of Fireproof Panel in Tunnel Duct Slab)

  • 최우진
    • 한국재난정보학회 논문집
    • /
    • 제19권2호
    • /
    • pp.262-269
    • /
    • 2023
  • 연구목적: 터널에서 발생되는 화재로 인하여 구조물의 피해를 보호하기 위해 적용되는 PSC 슬래브에 부착된 내화패널의 성능을 평가할 목적으로 내화실험을 수행하였다. 연구방법: 내화실험은 RWS 화재 이력곡선 화재시간-온도곡선을 적용하였으며, 한국건설기술연구원(KICT)의 가열로를 이용하여 내화 성능을 평가하였다. 연구결과:국제터널학회(2004)에서 제시하는 기준으로 내화성능 실험을 실시한 결과, 내화패널과 콘크리트의 접촉면에서의 최대온도는 콘크리트에 손상을 주는 한계온도(380℃) 이하였으며, 접촉면과 25mm 이격된 지점에서의 최대온도는 철근에 손상을 주는 한계온도(250℃) 이하로 측정되었다. 실험결과로부터, 내화패널이 30mm두께로 부착된 PSC 슬래브 시험체는 내화성능을 가진 것으로 평가되었다. 결론: 터널이나 지하차도에서의 화재발생시 내화패널을 부착하는 보강방법은 화재로부터 구조물을 보호할 수 있으며 향후, 내화패널이 부착된 슬래브의 정적 성능시험을 수행하고, Pull-off test와 피로실험을 실시하여 내화패널의 부착성능을 확인하는 것이 필요하다.

철근콘크리트조 화재건물의 부재내부온도분포 추정에 관한 연구 (A Study on Calculating the Temperature Distributions in the Concrete members of Reinforced Concrete Building with Fire Damage)

  • 오창희
    • 한국화재소방학회논문지
    • /
    • 제1권1호
    • /
    • pp.11-18
    • /
    • 1987
  • This study is for calculating the equation of the inner temperature in the concrete, mainly by the theory or heat conduction in the solid. The results are as follow ; 1. The equation of the Fourier's heat diffusion is used formally to get the distribution of inner temperature or the concrete members, and this is programed by using the computer. 2. As study in the past, heat constant of concrete is calculated for function of temperature described recommendation heat constant value in comparison with the existing inner heating experimental result.

  • PDF

내화 마감재 종류에 따른 고성능 RC기둥의 폭열방지 및 온도이력 특성 (Properties of Temperature History and Spatting Resistance of High Performance RC Column with Finishing Material)

  • 허영선;김기훈;이진우;이보형;이재삼;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 춘계 학술기술논문발표대회 논문집
    • /
    • pp.37-40
    • /
    • 2005
  • High Performance Concrete(HPC) has been widely used in high-rise building. The HPC has several benefits including high strength, high fluidity and high durability. However. spatting is susceptible to occur in HPC and HPC also tends to be deteriorated in the side of fire resistance performance at fire. This paper focuses on the analysis of the temperature history and residual compressive strength with finishing material, in order to protect HPC from sudden-high-temperature, which is one of the main reason spatting occurs. Test results show that spalling occurs in all specimens. The most serious spalling took placed in HPC covering fire enduring spray-on material, whose covering thickness is 20mm but temperature history indicates that fire enduring spray effectively protected HPC from fire for more than 2hours. In addition, residual compressive strength ratio of HPC using fire enduring paint was more than $90\%$ of original strength, thus minimizing spatting and indicating significant fire resistance performance.

  • PDF

An Experimental Study on the H-Beam Under Fire Load in Open Space

  • Ki, Min Suk;Park, Beom Jin;Lee, Kangsu;Park, Byoungjae;Fernandez, Kyle;Nho, In Sik
    • 한국해양공학회지
    • /
    • 제35권1호
    • /
    • pp.59-74
    • /
    • 2021
  • To validate the fire safety assessment of structures, many structural experiments under fire load have been conducted. However, most of these experiments were conducted in restricted environments, such as inside a furnace, and experiments were seldom carried out in open space. In this study, an experimental study on H-beams, frequently used as structural reinforcements, was carried out for validating the thermal-structural analysis method under development. A 1.8 MW burner fire was adopted with each end of the H-beam fixed without a mechanical load. Gas temperature, steel surface temperature, and displacements were then measured. During the experiment, gas and steel temperatures were obtained at 9 and 17 points near the H-beam, respectively. In addition, the vertical and horizontal displacements of the H-beam under fire load at 6 points were obtained. Furthermore, it was verified that the stable displacement measurements via the contact and non-contact methods were feasible in harsh environments where flames and smoke were both present.

Similarity of energy balance in mechanically ventilated compartment fires: An insight into the conditions for reduced-scale fire experiments

  • Suto, Hitoshi;Matsuyama, Ken;Hattori, Yasuo
    • Nuclear Engineering and Technology
    • /
    • 제54권8호
    • /
    • pp.2898-2914
    • /
    • 2022
  • When evaluating energy balance and temperature in reduced-scale fire experiments, which are conducted as an alternative to full-scale fire experiments, it is important to consider the similarity in the scale among these experiments. In this paper, a method considering the similarity of energy balance is proposed for setting the conditions for reduced-scale experiments of mechanically ventilated compartment fires. A small-scale fire experiment consisting of various cases with different compartment geometries (aspect ratios between 0.2 and 4.7) and heights of vents and fire sources was conducted under mechanical ventilation, and the energy balance in the quasi-steady state was evaluated. The results indicate the following: (1) although the compartment geometry varies the energy balance in a mechanically ventilated compartment, the variation in the energy balance can be evaluated irrespective of the compartment size and geometry by considering scaling factor F (∝heffAwRT, where heff is the effective heat transfer coefficient, Aw is the total wall area, and RT is the ratio of the spatial mean gas temperature to the exhaust temperature); (2) the value of RT, which is a part of F, reflects the effects of the compartment geometry and corresponds to the distributions of the gas temperature and wall heat loss.

플라이애시 및 경량골재를 활용한 경량 내화성 마감재료 개발 (Development of Light-weight Fire Protection Materials Using Fly Ash and Light-weight Aggregate)

  • 송훈;추용식;이종규;이세현
    • 한국건설순환자원학회논문집
    • /
    • 제6권4호
    • /
    • pp.95-102
    • /
    • 2012
  • 고층건축물의 구조부재로 적용되는 철골이나 고강도콘크리트로 시공된 경우 내화대책은 필수 불가결한 요소이며 특히, 고강도콘크리트로 적용된 경우 폭렬 등에 의한 단면결손이 발생하기 쉽기 때문에 이에 대한 대책이 필요하다. 즉, 내화성능 확보를 위해 온도상승을 허용범위 이내로 억제하는 대책이 필요하며 이 중 가장 효율적인 방법이 내화성 마감을 실시하는 것이다. 일반적으로 내화성 마감재에 사용되는 시멘트계 재료는 C-S-H, 및 CH가 단계적으로 열 분해되어 압축강도는 저하하게 된다. 내화성능을 발휘하기 위해 고온에서 강도감소가 작고 안정적인 고온특성을 보인다면 보다 효과적으로 성능 발현이 가능할 것이다. 본 연구는 고층건축물의 철골 및 콘크리트 부재의 효과적인 내화성능 발현을 위한 경량 내화성 마감재 개발을 위한 연구로 내화성능이 우수하다고 알려진 Alumino-silicate계 재료를 내화성 마감에 적용하기 위해 고온특성에 대해 검토하였다. 검토 결과, 플라이애시, 메타카올린 및 경량골재를 활용한 경량 내화성 마감재는 고온에서 비교적 안정적인 특성을 발현하여 내화성 마감재로의 효용성을 확인할 수 있었다.

  • PDF

열매유 보일러 내부화재에 따른 온도 및 속도분포 해석 (Temperature and Flow Velocity Analysis for Fire in Synthetic Heat Transfer Fluid Boiler)

  • 김엽래;손봉세
    • 한국화재소방학회논문지
    • /
    • 제27권5호
    • /
    • pp.19-25
    • /
    • 2013
  • 열매유(Synthetic Heat Transfer Fluid)의 가열현상으로 인하여 보일러에서 화재가 발생한 경우에 대하여 컴퓨터 수치해석을 통한 1, 2, 3차 패스 및 연소대의 온도 및 속도분포를 파악하였다. 보일러의 인버터의 고장으로 인하여 보일러 내부의 유동이 다소 불안전한 상태에서 운전이 지속되면서 화염의 유동과 속도가 불안정하게 작동된 것으로 판단된다. 열매유의 누유현상은 화재초기에 약 120 kg/min로 분출하면서 기화되었고, 또한 화염은 2차 패스와 3차 패스까지 열전달 현상이 확대되었다. 2차 패스에서의 최고온도는 $1,059^{\circ}C$, 3차 패스의 최고온도는 $1,007^{\circ}C$이고, 3차 패스 아래쪽에서는 온도가 $767^{\circ}C$인 것으로 컴퓨터 시뮬레이션 결과에서 알 수 있었다. 특히, 연소대는 1차 패스 균열부위에서 열매유가 분출되면서 턴테이블 위로 쌓였으며, 연소대 하부에서 온도는 플래시오버 현상에 의하여 $183^{\circ}C$까지 올라갔다. 따라서 연소대 내부의 온도는 $1,200^{\circ}C$ 이상으로 예측되었으며, 연소대의 온도는 순간적으로 여러 차례 최고점의 온도까지 도달되어 연소대에서 여러 차례 폭발현상이 발생한 것으로 판단되었다.

공연장 무대부 화재에 대한 전산해석 연구: 자연 배연구 면적과 화원 위치 영향 (Numerical Investigation on Fire of Stage in Theater: Effects of Natural Smoke Vent Area and Fire Source Location)

  • 박민영;이치영
    • 한국안전학회지
    • /
    • 제37권1호
    • /
    • pp.1-11
    • /
    • 2022
  • This numerical study investigates the effects of the size of the natural smoke vent area (10% and 1% of the floor area) and the location of the fire source (i.e., at the side and center of the stage) on the temperature distribution in the compartment and velocity distribution and mass flow rate of flow through a natural smoke vent for a reduced-scale model of a theater stage. Then, the mass flow rate of outflow through the natural smoke vent in the event of a fire for a real-scale theater stage was examined. The case with the larger natural smoke vent area and central fire source location showed lower temperature distributions and higher mass flow rates of outflow and inflow than the case with the smaller natural smoke vent area and side fire source location. The trends of the temperature distributions were closely related to those of the mass flow rates for the outflow and inflow. Additionally, the case with the larger natural smoke vent area and central fire source location exhibited the most non-uniform flow velocity distribution in all cases tested. A bidirectional flow, in which the outflow and inflow occur simultaneously, was observed through the natural smoke vent. In the event of a fire situation in a real-scale theater stage, it was predicted that the case with the larger natural smoke vent area and central fire source location would have a mass flow rate of outflow that is 43.53 times higher than that of the case with the smaller natural smoke vent area and side fire source location. The present results indicate that the natural smoke vent location should be determined by considering the location in a theater stage where a fire can occur.