• Title/Summary/Keyword: fire scenarios

Search Result 247, Processing Time 0.025 seconds

Implementation of Fire Risk Estimation System for various Fire Situations using Multiple Sensors (다중 센서들을 이용한 다양한 화재 상황의 위험도 추정 시스템 개발)

  • Lee, Kwangjae;Lee, Youn-Sung
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.394-398
    • /
    • 2016
  • In this paper, a fire detection system based on quantitative risk estimation is presented. Multiple sensors are used to build a comprehensive indicator that represents the risk of fire quantitatively. The proposed fire risk estimation method consists of two stages which determines the occurrence of fire and estimates the toxicity of the surveillance area. In the first stage, fire is reliably detected under diverse fire scenarios. The risk of fire is estimated in the second stage. Applying Purser's Fractional Effective Dose (FED) model which quantitates harmfulness of toxic gases, the risk of the surveillance area and evacuation time are calculated. A fire experiment conducted using four different types of combustion materials for the verification of the system resulted in a maximum error rate of 12.5%. By using FED calculation and risk estimation methods, the proposed system can detect various signs of fire faster than conventional systems.

Fire-induced damage on Shield TBM concrete segment (터널 화재로 인한 콘크리트 세그먼트의 손상특성 규명)

  • Choi, Soon-Wook;Chang, Soo-Ho;Lee, Gyu-Phil;Bae, Gyu-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.423-430
    • /
    • 2005
  • Fire accidents in underground space may bring much loss of lives as well as properties and result in catastrophic disasters. This study aimed to manufacture the high-temperature furnace capable of simulating fire scenarios (RABT and RWS) and carry out the preliminary fire tests to evaluate fire-induced damage in underground structures. Specimens used in the fire tests were the concrete segments generally used in shield TBM tunnels. The simulated fire scenario was set to the RABT curve that is the most representative fire scenario in underground space. From the fire tests, the spalling was estimated to reach approximately 20cm from the surface exposed to fire. In addition, from the observation of core specimens obtained after fire tests, the deteriorated zone of unspalled specimens amounted to approximately 10cm from the surface of spalling.

  • PDF

A Study on the Behaviour of Smoke Spread Caused by Vehicle Fire in a Road Tunnel (터널 내 차량 화재에 따른 연기 확산 거동에 관한 연구)

  • Yoon, Yong-Kyun;Ju, Eun-Hye
    • Tunnel and Underground Space
    • /
    • v.22 no.5
    • /
    • pp.365-372
    • /
    • 2012
  • This paper aims to evaluate the effects that presence, installation number and capacity of ventilation vent and presence of multiple fire sources have on the behaviour of smoke temperature induced by vehicle fire in road tunnel. Six types of scenarios were assumed and FDS was ran to simulate them. As the number of ventilation vents increases, the smoke temperature are calculated to be reduced, but it is shown that effects exerted by two ventilation vents are almost similar to ones by three ventilation vents. Capacity of ventilation vent has a greater impact on the reduction of smoke temperature than installation number of ventilation vents. Smoke temperatures computed for all scenarios except for scenario No. 1 (without ventilation vent) and scenario No. 6 (with multiple fire sources) above fire source are analyzed to be under $400^{\circ}C$ and it means that the radiation of smoke layer above fire source doesn't induce the ignition of materials around fire source.

A Study on the Fire Scenarios according to Initial Fire Source Classification and Fire Statistics Investigation of Business & Sales Faciliteis (업무·판매시설의 화재통계조사 및 초기화원분류를 통한 화재시나리오에 관한 연구)

  • Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.42-43
    • /
    • 2017
  • In Korea, The buildings are getting higher and bigger, and also the fire risk is getting increased. The PBD was introduced in 2009 for the fire safety of these buildings, but the study on making scenario based on actual case of fire is insufficient. Therefore on this study, it will conduct an experiment about initial fire classification and making fire scenario based on that actual fire statistic investigation classification of PBD buildings as official and commercial facilities.

  • PDF

Simulating the Response of a 10-Storey Steel-Framed Building under Spreading Multi-Compartment Fires

  • Jiang, Jian;Zhang, Chao
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.4
    • /
    • pp.389-396
    • /
    • 2018
  • This paper presents a numerical investigation on the structural response of a multi-story building subjected to spreading multi-compartment fires. A recently proposed simple fire model has been used to simulate two spreading multi-compartment fire scenarios in a 10-story steel-framed office building. By assuming simple temperature rising and distribution profiles in the fire exposed structural components (steel beams, steel column and concrete slabs), finite element simulations using a three-dimensional structural model has been carried out to study the failure behavior of the whole structure in two multi-compartment fire conditions and also in a standard fire condition. The structure survived the standard fire but failed in the multi-compartment fire. Whilst more accurate fire models and heat transfer models are needed to better predict the behaviors of structures in realistic fires, the current study based on very simple models has demonstrated the importance and necessity of considering spreadingmulti-compartment fires in fire resistance design of multi-story buildings.

Development Direction of Fire Consequence Analysis Programs for Hazardous Materials (위험물 취급설비 화재 사고결과 영향평가 프로그램 개발 방향)

  • 유재환;김용수;이영순;이경봉;이성우;박달재
    • Fire Science and Engineering
    • /
    • v.13 no.4
    • /
    • pp.1-6
    • /
    • 1999
  • In this paper, We have analyzed the application characteristics of the three different consequence programs(SuperChems Pro., PHAST Pro., and SAFER Trace) for the models (pool fire, jet fire & flare, fireball, flash fire) based on the four possible accident scenarios. And we have proposed a development direction of fire consequence analysis models using the related theories and the results analysis of consequence programs.

  • PDF

A Study on Assessment of Fire and Evacuation Safety in Environmental Energy Facilities (환경에너지시설의 화재 및 피난 안전성 평가에 관한 연구)

  • Jeon, Yong-Han;Han, Sang-Pil
    • Journal of the Korea Safety Management & Science
    • /
    • v.21 no.4
    • /
    • pp.39-44
    • /
    • 2019
  • In this study, fire and evacuation safety of environmental energy facilities using fire and evacuation simulation was examined as part of performance-oriented design. The worst-case fire scenarios in which fire-fighting facilities such as sprinkler fire extinguishing and smoke control systems are not working, and the FDS analyzes the visibility, temperature distribution, and carbon monoxide concentration distribution through FDS. The safety was examined. As a result, it was proved that evacuation could limit the visibility, temperature, and carbon monoxide concentration in a smooth range, based on the safety standards set by relevant laws. In other words, it was possible to verify the safety of fire and evacuation for environmental energy facilities where a large amount of combustibles and fires coexist.

NUMERICAL SIMULATION OF WIND-DRIVEN FIRE FLUMES

  • Kohyu Satoh;Yang, K.T.
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.327-334
    • /
    • 1997
  • In many large urban-fire scenarios one of the critical issues is to attempt to protect the lives of fire fighters in helicopters deployed to flying over the fires and also the lives of people trapped in open areas downwind of the fires such as in parks. The strategies of such protection measures depend significantly on our knowledge of the size and extent of such fires as affected by the prevailing winds. In this study, the shape or profile of the fire plume typical of large urban fires, as affected by a steady unidirectional wind with or without imposing a shear flow on the fire plume, has been simulated numerically by a field model. The results show that the simulations provide realistic flame profiles and at least qualitatively, the same flame dynamics when compared to those from the experiments, and that the fire plumes are sensitive to small variations in the asymmetry of the wind shears, including the appearance of swirling flames within the fire plumes.

  • PDF

COMPARISON OF THE FIRE SUPPRESSION PERFORMANCE OF HALON REPLACEMENT AGENTS

  • Kim, Andrew K.;Joseph Z. Su
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.542-549
    • /
    • 1997
  • HFC-227ea and HCFC Blend A were evaluated using full-scale fire tests to obtain information on their fire suppression performance, drop-in capability, thermal decomposition products and physical behaviour of the agent such as its flow characteristics in the piping system. Also, full-scale tests were conducted with Halon 1301 to provide a basis for comparison. Halon 1301, at concentrations of 5% to 7.5%, showed effective total-flooding fire- extinguishing performance for all test scenarios. HFC-227ea, at a design concentration of 7.6% or higher, and HCFC Blend A, at a design concentration of 12%, extinguished all fires in the test facility, however, these agents produced higher concentrations of acid gases than Halon 1301. The quantity of the acid gases generated during fire suppression was dependent on agent concentration, agent discharge time, fire type and size as well as extinguishment time.

  • PDF

A Fire Simulation of Light Railway Transit (경량전철시스템의 화재 시뮬레이션)

  • Won Chan-Shik;Lee Ki-Choon;Hur Nahmkeon;Mok Jae-Kyun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2001.05a
    • /
    • pp.170-175
    • /
    • 2001
  • Fire inside light railway transit(LRT) was simulated for various fire scenarios using CFD analysis in order to assess the safety of passengers. Considered in the present paper are the effects of locations of fire, a fire size, an operation of ventilation system and an opening time of door on evolution of temperature and smoke concentration inside the LRT. For fire simulation, fire cells releasing heat and smoke corresponding to fire size were positioned at the location of fire. From the results, it is seen that the ventilation system and the opening time of door were the most important factors on temperature and smoke concentration inside the LRT

  • PDF