• Title/Summary/Keyword: fire intensity

Search Result 167, Processing Time 0.023 seconds

Estimation of Fire Emissions Using Fire Radiative Power (FRP) Retrieved from Himawari-8 Satellite (히마와리 위성의 산불방사열에너지 자료를 이용한 산불배출가스 추정: 2017년 삼척 및 강릉 산불을 사례로)

  • Kim, Deasun;Won, Myoungsoo;Lee, Yangwon
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.6_1
    • /
    • pp.1029-1040
    • /
    • 2017
  • Wildfires release a large amount of greenhouse gases (GHGs) into the atmosphere. Fire radiative power (FRP) data obtained from geostationary satellites can play an important role for tracing the GHGs. This paper describes an estimation of the Himawari-8 FRP and fire emissions for Samcheock and Gangnueng wildfire in 6 May 2017. The FRP estimated using Himawari-8 well represented the temporal variability of the fire intensity, which cannot be captured by MODIS (Moderate Resolution Imaging Spectroradiometer) because of its limited temporal resolution. Fire emissions calculated from the Himwari-8 FRP showed a very similar time-series pattern compared with the AirKorea observations, but 1 to 3 hour's time-lag existed because of the distance between the station and the wildfire location. The estimated emissions were also compared with those of a previous study which analyzed fire damages using high-resolution images. They almost coincided with 12% difference for Samcheock and 2% difference for Gangneung, demonstrating a reliability of the estimation of fire emissions using our Himawari-8 FRP without high-resolution images. This study can be a reference for estimating fire emissions using the current and forthcoming geostationary satellites in East Asia and can contribute to improving accuracy of meteorological products such as AOD (aerosol optical depth).

A Study on forest fires Prediction and Detection Algorithm using Intelligent Context-awareness sensor (상황인지 센서를 활용한 지능형 산불 이동 예측 및 탐지 알고리즘에 관한 연구)

  • Kim, Hyeng-jun;Shin, Gyu-young;Woo, Byeong-hun;Koo, Nam-kyoung;Jang, Kyung-sik;Lee, Kang-whan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.6
    • /
    • pp.1506-1514
    • /
    • 2015
  • In this paper, we proposed a forest fires prediction and detection system. It could provide a situation of fire prediction and detection methods using context awareness sensor. A fire occurs wide range of sensing a fire in a single camera sensor, it is difficult to detect the occurrence of a fire. In this paper, we propose an algorithm for real-time by using a temperature sensor, humidity, Co2, the flame presence information acquired and comparing the data based on multiple conditions, analyze and determine the weighting according to fire in complex situations. In addition, it is possible to differential management of intensive fire detection and prediction for required dividing the state of fire zone. Therefore we propose an algorithm to determine the prediction and detection from the fire parameters as an temperature, humidity, Co2 and the flame in real-time by using a context awareness sensor and also suggest algorithm that provide the path of fire diffusion and service the secure safety zone prediction.

Evaluation of the Radiant Heat Effects according to the Change of Wind Velocity in Forest Fire by using WFDS (WFDS를 이용한 풍속에 따른 산림화재 복사열 강도 평가)

  • Song, Dong-Woo;Lee, Su-Kyung
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.1-7
    • /
    • 2013
  • The wildland fire intensity and scale are getting bigger owing to climate change in the world. In the case of domestic, the forest is distributed over approximately 63.7 % of country and the main facilities like a industrial facility or gas facility abuts onto it. Therefore there is potential that the wildland fire is developed to a large-scale disaster. In this study, the effect distances of the radiant heat flux from the crown fire are analysed according to the change of wind velocity. The safety criteria concerning the radiant heat flux to influence on the surrounding were researched to analyse the effect distances. The criteria of radiant heat flux were chosen $5kW/m^2$, $12.5kW/m^2$, $37.5kW/m^2$. WFDS, which is an extension of NIST's Fire Dynamics Simulator, was used to consequence analysis of the forest fire. In order to apply the analysis conditions, it is researched the forest conditions that is generally distributed in domestic region. As the result, the maximum effect distances by radiant heat were showed at the horizontal and vertical direction. When the wind velocity varied from 0 to 10 m/s, the maximum effect distance increased as the wind velocity increases. Interesting point is that the maximum effect distance were shown at the wind velocity of 8 m/s. The maximum effect distance was decreased according as the fuel moisture of trees increase. This study can contribute to analyse quantitative risk about the damage effect of the surrounding facilities caused by wildland fire.

Fire Severity Mapping Using a Single Post-Fire Landsat 7 ETM+ Imagery (단일 시기의 Landsat 7 ETM+ 영상을 이용한 산불피해지도 작성)

  • 원강영;임정호
    • Proceedings of the KSRS Conference
    • /
    • 2001.03a
    • /
    • pp.71-76
    • /
    • 2001
  • 인공위성을 이용하여 산불피해지역을 분석하기 위해 KT(Kauth-Thomas)변환기법과 IHS(Intensity-Hue-Saturation)변환기법을 적용하여 비교해 보고 산불피해등급지도를 작성하였다. 방사보정과 지형보정을 수행한 영상을 각각 IHS와 KT로 변환시킨 후 최대우도법에 의하여 분류하였다. 정확도 평가에서 KHAT statistic은 각각 0.67와 0.76을 나타내었다. 현장데이터가 부족하여 cross-validation을 수행하였으며, 일관되게 KT변환기법에 의한 분류결과가 IHS기법에 의한 분류결과보다 더 높은 정확도를 보여주었다. 또한 KT feature space 와 IHS 컴포넌트의 분광 분포를 그래프 상에서 분석해 보았다. 3개의 KT feature 중, greenness와 wetness가 brightness 보다 각 클래스에 대해서 보다 높은 분리성을 제공하였다. 하니만 IHS 컴포넌트의 분광분포는 뚜렷한 분리성이 나타나지 않고 서로 섞여 있는 것을 볼 수 있었다. 따라서, KT변환기법이 IHS변환기법보다 산불피해지역을 추출함에 있어 더 높은 정확도를 나타내고, 산불과 관련된 지표의 물리적 특성을 더 잘 반영한다고 할 수 있다.

  • PDF

Design and construction of a new ultraviolet sensor using CsI deposition in the ionization chamber

  • Souri, R.;Negarestani, A.;Souri, S.;Farzan, M.;Mahani, M.
    • Nuclear Engineering and Technology
    • /
    • v.50 no.5
    • /
    • pp.751-757
    • /
    • 2018
  • In this article, a UV sensor that is an appropriate tool for fire detection has been designed and constructed. The structure of this UV sensor is an air-filled single-wire detector that is able to operate under normal air condition. A reflective CsI photocathode is installed at the end of the sensor chamber to generate photoelectrons in the ion chamber. An electric current is produced by accelerating photoelectrons to the anode in the electric field. The detector is able to measure the intensity of the incident UV rays whenever the current is sufficiently high. Therefore, the sensitivity coefficient of this sensor is found to be $7.67{\times}10^{-6}V/photons/sec$.

Citic Tower Construction Key Technology

  • Xu, Lishan
    • International Journal of High-Rise Buildings
    • /
    • v.8 no.3
    • /
    • pp.185-192
    • /
    • 2019
  • Citic Tower is the first over-500 m-tall super highrise building in the world, located in the high seismic intensity area with paek ground acceleration over 0.2g in 475 years. This project is unique in its complexity, large volume, and challenging site conditions (zero site for construction). The traditional techniques can hardly meet safty, quality and schedule requirements of the construction. This article introduces the key construction technologies that are innovatively developed and applied in Citic Tower project construction, including intelligent super-high-rise building integrated construction platform system, independently developed by the CCTEB; Jump-Lift Elevator, which is the first of the kind with service height over 500 meters; combined temporary-and-permanent fire protection systems. The BIM technology is also applied in this project. Through technical innovation, and utilization of technologies, construction speed and safety had been greatly improved.

Physiological Changes According to Workload Wearing Aluminized Firefighter's Protective Clothing (소방방열복 착용시 작업강도에 따른 신체변화)

  • Bang, Chang-Hoon;Lee, Jun-Kyoung;Kwan, Jung-Suk
    • Fire Science and Engineering
    • /
    • v.27 no.4
    • /
    • pp.56-60
    • /
    • 2013
  • The aim of study intends to investigate physiological changes according to workload wearing aluminized firefighter's protective clothing and to provide the base data for the safety of firefighter. The results of the study are as follows. To increase work intensity 4 to 8 METs after experiment (20 min), mean skin temperature change (33.3 %), tympanic temperature change (57.1 %) heart rate (32.5 %), RPE (75.6 %) is statistically significantly higher and thermal Sensation, weight loss are not statistically significant. It was concluded that physiological changes of human body varied considerably by increase of workload wearing aluminized firefighter's protective clothing.

A Quantitative Analysis for Forest Fire Burned Area Using IHS Transformation (IHS 변환을 이용한 산화지 정량화 분석)

  • Jung, Tae-Woong;Yoon, Bo-Yeol;Kim, Choen
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.459-462
    • /
    • 2005
  • 위성화상 또는 항공사진을 이용하여 산화지를 탐지하고 정량화하기 위한 여러 가지 방법적인 시도가 있었다. 보다 정확한 산화지 탐지를 위해, 본 연구에서는 기존의 고해상도 범색화상과 중 저해상도 다중분광 화상의 융합(fusion)에 주로 이용되었던 IHS(Intensity, Hue, Saturation) 색채변환을 산화지 탐지와 정량화에 적용하였다. IHS 색채변환을 이용한 Hue 조합화상의 산화지 최대우도분류 결과는 Landsat-7 ETM+ 7:4:1 조합화상보다 놀은 사용자분류 정확도를 나타냈으며 색상(Hue)과 채도(Saturation)가 명도(Intensity)에 비해 ETM+ 화상의 분광특성을 잘 반영하였다.

  • PDF

UV Detecting according to Corona Discharge Intensity using UV Sensor (자외선 센서를 이용한 코로나 방전 강도에 따른 자외선 검출)

  • Kwag, Dong-Soon;Kim, Young-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.3
    • /
    • pp.78-83
    • /
    • 2014
  • To minimize the financial loss due to power facility malfunction, on-line diagnostic techniques are required to grasp any abnormal state of facilities in the live line as well as devices to diagnose abnormal states of power facility in an easy and prompt manner. This study aims to develop a portable UV detecting system by means of UV sensors for easier and efficient inspection of the degradation state of power facility in a long distance. Accordingly, it includes a simulation of corona discharges that may occur due to degradation of power facility and detection of ultraviolet pulse generation depending on the corona discharge intensity and measuring distance in application of UV sensors. Additionally, the optimal algorithm is determined for its application to the system's degradation diagnosis program based on the measured experiment data.

A Study on Pain and Anxiety of Burn Patients (화상환자가 지각하는 통증과 불안에 관한 연구)

  • Park Young Sook;Kim Eun Hee
    • Journal of Korean Public Health Nursing
    • /
    • v.15 no.1
    • /
    • pp.83-95
    • /
    • 2001
  • The purpose of this study is to examine intensity of pain and anxiety of burn patients. This study selected 99 adult patients of 18 years old or older who have been hospitalized and treated for a second-degree burn at the surgery ward or burn ward of 3 university hospitals which are located in 2 metropolitan cities, and a university hospital in Seoul Special City from July 1 to October 20, 2000. This study used STAI(State-Trait Anxiety Inventory) developed by Spielberger, and translated by Kim, Jung Taek and Shin, Dong Kyun to examine the degree of anxiety and VAS to examine the pain. This study was carried out by interview and using SPSS 9.0 statistical program. Results were as follows : 1) As for general characteristics of the subjects, they were mostly male. 30s-40s, married, and high school graduates. 2) Forty-seven patients were burned by fire and $49.6\%$ of the patients had burn 10 to $20\%$ of BSA. seventy-nine percents of patients received one dressing change a day and $74.3\%$ received medication once or twice a day. 3) As for intensity of anxiety and pain. the mean intensity of pain was 6.41. The intensity of trait anxiety and the state anxiety were 39.76. and 51.81. 4) Subject's age was significantly different in their pain intensity and other variables were insignificant. Correlations between trait-anxiety and state-anxiety(r=.286, p=.004), and state-anxiety and VAS(r=.294, p=.003) showed weak correlation. There wasn't statistically any significance in trait- anxiety and VAS(r=.183, p=.070).

  • PDF