• Title/Summary/Keyword: fire environment

Search Result 1,068, Processing Time 0.032 seconds

A Study on the Impact Scope from Hazardous Chemicals Leakage in Jeju Area - Focused on hydrogen fluoride - (제주지역 유해화학물질 누출사고 시 영향범위에 관한 연구 - 불화수소 중심으로 -)

  • Lim, Chaehyun;Doh, Sang Hyeun;Kim, Changyoung
    • Journal of the Korean Society of Urban Environment
    • /
    • v.18 no.4
    • /
    • pp.495-502
    • /
    • 2018
  • In this study, the AERMOD air diffusing model was used to estimate the range of influence of Hazardous chemicals (hydrogen fluoride) in case of small accidents in Jeju area. The impact scope were in the order of Seogwipo Fire Station, Dongbu Fire Station, Jeju Fire Station, and Seobu Fire Station. Seasonal orders were summer, spring, autumn and winter. The correlation between the meteorological factors shows a strong positive correlation with the wind speed of 0.998 and has a negative correlation with the temperature of -0.463. Through the linear regression analysis, we could estimate the equation of Impact scope = 13.922WS (Wind Speed) - 5.195 and the reliability ($R^2$) was as high as 0.995.

Development of Fire Detection Algorithm for Video Incident Detection System of Double Deck Tunnel (복층터널 영상유고감지시스템의 화재 감지 알고리즘 개발)

  • Kim, Tae-Bok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.9
    • /
    • pp.1082-1087
    • /
    • 2019
  • Video Incident Detection System is a detection system for the purpose of detection of an emergency in an unexpected situation such as a pedestrian in a tunnel, a falling object, a stationary vehicle, a reverse run, and a fire(smoke and flame). In recent years, the importance of the city center has been emphasized by the construction of underpasses in great depth underground space. Therefore, in order to apply Video Incident Detection System to a Double Deck Tunnel, it was developed to reflect the design characteristics of the Double Deck Tunnel. and In this paper especially, the fire detection technology, which is not it is difficult to apply to the Double Deck Tunnel environment because it is not supported on existing Video Incident Detection System or has a fail detect, we propose fire detection using color image analysis, silhouette spread, and statistical properties, It is verified through a real fire test in a double deck tunnel test bed environment.

An experimental study on the fireproof performance of fire damper according to change of the insulation conditions on the exposed side and unexposed side of the coaming (코밍 노출면 방열 두께 및 비 노출면 방열 길이 변화에 따른 방화 댐퍼의 내화성능에 관한 실험적 연구)

  • Choi, Tai-Jin;Kim, Joung-Sik;Lim, Young-Soo;Lee, Kyung-Hyun;Kang, Ho-Keun;Park, Sung-Ho;Kim, You-Taek
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.99-104
    • /
    • 2014
  • In this paper, Fire resistance test was carried out in accordance with the change of the insulation conditions on the exposed side and unexposed side of the coaming to obtain optimal insulation conditions for class H-120 insulation in connection with specimen-1 of the preceding paper for the evaluation of fireproof performance for fire dampers according to hydrocarbon fire conditions. As a test result, specimen-2(88 mm, $171^{\circ}C$) was satisfied class H-120 insulation, but specimen-3(76 mm, $181^{\circ}C$) was exceeded thermal insulation acceptance criteria at 110 minutes, therefor, specimen-2(88 mm) is optimal insulation conditions as possible lightweight than specimen-1. Test result comparison, we concluded that temperature rising of the coaming insulation surface was influenced by conductive heat from the bulkhead, and coaming surface was influenced by radiant heat from blade & coaming.

Deregulation of the Fire Prevention Legislation; and Its Impact on Fire Occurrence - Case of the United Kingdom - (′화재예방법규′의 규제완화가 화재발생에 미치는 영향 -영국 사례분석 -)

  • 이재열
    • Fire Science and Engineering
    • /
    • v.15 no.2
    • /
    • pp.13-19
    • /
    • 2001
  • The OECD defines regulatory reform as both better regulation and deregulation, and emphasizes that governments must continue to regulate in areas such as environmental quality and safety. In contrast, Korean regulatory reform in fire services in the 1990s shows quite a strange trend, having been carried out only to the direction of softening and abolishing regulations. In the UK, fire prevention legislation has been strengthened since the enactment of the Fire Precautions Act 1971, and the Building Regulations 1991, which apply to all new buildings including a private house, require that there should be at least one smoke alarm on each floor. This research shows that the tightening of fire prevention legislation in the UK has promoted fire safety, which is very instructive for Korean fire services. In order for Korean fire services to protect citizens'lives and property from fires, one of basic directions of regulatory reform, to improve the quality of regulations relating to safety, health and the environment, should be observed strictly. Moreover, the flexibility of the basic direction of regulatory reform should be ensured so that the regulations concerning safety could be even increased under the overall reform strategy of reducing all regulations.

  • PDF

Study of Post-Fire Safe-Shutdown Analysis of a CANDU Main Control Room based on NEI 00-01 Methodology (NEI 방법론을 적용한 중수로 주제어실의 화재안전정지분석에 관한 연구)

  • Kim, In-Hwan;Lim, Heok-Soon;Bae, Yeon-Kyoung
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.20-26
    • /
    • 2016
  • When the fire takes place in Nuclear Powr Plants(NPPs), the reactor should achieve and maintain safe shut-down conditions and minimize the radioactive material released to the environment. The U.S. Nuclear Regulatory Commission (NRC) has issued numerous generic communications related to fire protection over the past 20 years, after it issued its requirements in the Fire Protection Rule set forth in Title 10, Section 50.48 of the Code of Federal Regulations (10 CFR 50.48) and Appendix R to the 10 CFR 50. The and Nuclear Energy Institute (NEI) has developed a Methodology for Risk Informed Fire Safe-Shutdown Analysis, which is related to the Deterministic Method for Multiple Spurious Operations solutions. The aim of this study was to identify, achieve, and maintain Post-Fire Safe-Shutdown of the Main Control Room (MCR) of the CANDU reactor, even though one train of the multiple Safety Structures, Systems, and Components (SCCs) fail by the technical specification and analysis method.

The Development of Forest Fire Statistical Management System using Web GIS Technology

  • Jo, Myung-Hee;Kim, Joon-Bum;Kim, Hyun-Sik;Jo, Yun-Won
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.183-190
    • /
    • 2002
  • In this paper forest fire statistical information management system is constructed on web environment using web based GIS(Geographic Information System) technology. Though this system, general users can easily access forest fire statistical information and obtain them in visual method such as maps, graphs, and text if they have web browsers. Moreover, officials related to forest fire can easily control and manage all information in domestic by accessing input interface, retrieval interface, and out interface. In order to implement this system, IIS 5.0 of Microsoft is used as web server and Oracle 8i and ASP(Active Server Page) are used for database construction and dynamic web page operation, respectively. Also, Arc IMS of ESRI is used to serve map data using Java and HTML as system development language. Through this system, general users can obtain the whole information related to forest fire visually in real time also recognize forest fire prevention. In addition, Forest officials can manage the domestic forest resource and control forest fire dangerous area efficiently and scientifically by analyzing and retrieving huge forest data through this system. So, they can save their manpower, time and cost to collect and manage data.

  • PDF

Electrical Fire Cause Diagnosis System based on Fuzzy Inference

  • Lee, Jong-Ho;Kim, Doo-Hyun
    • International Journal of Safety
    • /
    • v.4 no.2
    • /
    • pp.12-17
    • /
    • 2005
  • This paper aims at the development of an knowledge base for an electrical fire cause diagnosis system using the entity relation database. The relation database which provides a very simple but powerful way of representing data is widely used. The system focused on database construction and cause diagnosis can diagnose the causes of electrical fires easily and efficiently. In order to store and access to the information concerned with electrical fires, the key index items which identify electrical fires uniquely are derived out. The knowledge base consists of a case base which contains information from the past fires and a rule base with rules from expertise. To implement the knowledge base, Access 2000, one of DB development tools under windows environment and Visual Basic 6.0 are used as a DB building tool. For the reasoning technique, a mixed reasoning approach of a case based inference and a rule based inference has been adopted. Knowledge-based reasoning could present the cause of a newly occurred fire to be diagnosed by searching the knowledge base for reasonable matching. The knowledge-based database has not only searching functions with multiple attributes by using the collected various information(such as fire evidence, structure, and weather of a fire scene), but also more improved diagnosis functions which can be easily wed for the electrical fire cause diagnosis system.

Analysis on Field Professionals' Assessment of Alternative Fire Escape Methods in Apartment Building (공동주택 대안적 화재 피난방식에 대한 건설전문가 평가조사)

  • Lee, Myung Sik;Lee, So Young
    • KIEAE Journal
    • /
    • v.9 no.5
    • /
    • pp.21-28
    • /
    • 2009
  • In apartment buildings, casualties, especially fatalities have occurred in balcony areas in fires if residents fail to escape to the main entrance. Potential consequences of a particular infrequent event should be considered. In attempting to design apartment buildings for fire safety, alternative escape methods such as vertical penetration could be considered. The purpose of this study is to investigate present building regulations regarding apartment buildings and examine pros and cons of the current escape method and alternative escape methods. Focus group interview was conducted to discuss problems of fire escape methods. In addition, questionnaires were distributed to field professionals working in architecture, construction and related industries. Among 500 questionnaires distributed, 192 questionnaires were collected. Usable 162 questionnaires were analyzed using SPSS 15. Regarding alternative fire escape methods, several concerns were mentioned. Safety, privacy, security, effectiveness of escape, water proof problems were raised. Based on the opinions, vertical penetration between apartment unit appeared more safe, secure, effective than horizontal penetration. However, both methods have its own pros and cons under specific contexts. Alternative escape methods need be considered for a selective options for residents in case of fire.

A Study on the Analysis of Fire Patterns using the Decision Tree Analysis Method (의사결정분석방법을 활용한 화재유형분석에 관한 연구)

  • Lee, Hae-Pyeong;Lee, Seung-Chul;Hwang, Me-Jung;Park, Young-Ju;Moon, Kyong-Ae;Kim, Hyo-Beom
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.349-353
    • /
    • 2010
  • 본 연구에서는 통계분석방법 가운데 하나인 의사결정분석방법을 활용하여 소방방재청 국가화재정보시스템의 2007년부터 2009년까지 강원지역에서 발생한 화재발생 데이터를 대상으로 화재발생에 대한 유형을 분석하였다. 이와 같은 분석결과는 체계적이고 효율적인 소방정책을 수립하기 위한 기초 자료로 활용될 수 있을 것으로 사료된다. 변수선정은 NFDS의 변수들 가운데 화재유형분석에 영향을 줄 것으로 판단되는 변수들만을 대상으로 요인변수들을 발화환경, 화재원인, 진화요인 등 3개의 그룹으로 분류하였으며, 목적변수로는 화재피해와 화재건수를 선정하였다. 또한 NFDS의 제공 데이터들 이외에도 분석의 신뢰도와 정확도를 높이고자 통계청에서 제공하는 2007년과 2008년 외부데이터를 포함시켰다. 분석방법은 대분류 차원의 화재유형별 분석을 수행하고자 인명피해, 재산피해, 화재건수 등 3개의 목적변수를 대상으로 변수들의 영향력을 고찰하였다.

  • PDF

Study on the adoption of vocational aptitude test in the fire service (소방공무원의 직업 적성도 도입에 관한 연구)

  • Park, Kyong-Jin;Lee, Bong-Woo;Lee, Guen-Cull;Nam, Ki-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.2
    • /
    • pp.155-161
    • /
    • 2019
  • Recently, increases in major disasters such as fires, earthquakes and typhoons have raised public expectations for safety. In addition to this increase in expectations of safety, the government continues to push for more manpower and better treatment for firefighters who are operating in the disaster scene. Despite the improvement of working conditions and increased welfare for firefighters, however, the incidence and turnover of various mental diseases continues to increase. It is reported that many of the diseases such as post-traumatic stress disorder and the turnover of firefighters are due to a mismatch in individual's personality and work environment. In this study, 108 firefighters were evaluated for their vocational aptitude in the new curriculum. Based on the analysis results, new firefighters were proposed to provide employment and education training improvements, and to provide job security suitable for the individual's personality type through the introduction of the vocational aptitude test for firefighters who are working in the fire service. In addition, we would like to use the vocational aptitude test as a material for reducing post-traumatic stress disorder and increasing turnover through long-term tracking and observation, rather than from a one-off perspective.