• 제목/요약/키워드: fire environment

검색결과 1,075건 처리시간 0.033초

Research of Foresight Knowledge by CMAC based Q-learning in Inhomogeneous Multi-Agent System

  • Hoshino, Yukinobu;Sakakura, Akira;Kamei, Katsuari
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2003년도 ISIS 2003
    • /
    • pp.280-283
    • /
    • 2003
  • A purpose of our research is an acquisition of cooperative behaviors in inhomogeneous multi-agent system. In this research, we used the fire panic problem as an experiment environment. In Fire panic problem a fire exists in the environment, and follows in each steps of agent's behavior, and this fire spreads within the constant law. The purpose of the agent is to reach the goal established without touching the fire, which exists in the environment. The fire heat up by a few steps, which exists in the environment. The fire has unsureness to the agent. The agent has to avoid a fire, which is spreading in environment. The acquisition of the behavior to reach it to the goal is required. In this paper, we observe how agents escape from the fire cooperating with other agents. For this problem, we propose a unique CMAC based Q-learning system for inhomogeneous multi-agent system.

  • PDF

친환경 고발포 소화약제 개발 및 성능 분석 연구 (Analysis of Performance and Development of Environment-friendly High Expansion Foam Concentrate)

  • 김하영;남준석;이동호
    • 한국안전학회지
    • /
    • 제25권4호
    • /
    • pp.25-29
    • /
    • 2010
  • Foam concentrate is used for fire-extinguishing purposes, occurring foam, mixed with air. In huge oil-fire or the efficiency of fire-extinguishing with small quantity of water, Foam concentrate is used widely. However, perfluorooc tanoicsulfonate and nonylpenol that are included in Foam concentrate could be exposure in danger while they were discharged. The purpose of the research is the development of environment-friendly high expansion foam that exclude the dangerous substances and improvement of danger of the existing foam concentrate. The developed foam is analyzed as the environment-friendly foam in indexes of the environment-toxicity, the biodegradation appraisal, and the dangerous substances-detecting. In addition, the performances of expansion rate, discharge rate, and fire-extinguishing are suitable in the domestic regulation, so it is useful for fire-extinguishing in real fire situation.

화재 특성 고찰을 통한 농연 극복 센서 모듈 (A Sensor Module Overcoming Thick Smoke through Investigation of Fire Characteristics)

  • 조민영;신동인;전세웅
    • 로봇학회논문지
    • /
    • 제13권4호
    • /
    • pp.237-247
    • /
    • 2018
  • In this paper, we describe a sensor module that monitors fire environment by analyzing fire characteristics. We analyzed the smoke characteristics of indoor fire. Six different environments were defined according to the type of smoke and the flame, and the sensors available for each environment were combined. Based on this analysis, the sensors were selected from the perspective of firefighter. The sensor module consists of an RGB camera, an infrared camera and a radar. It is designed with minimum weight to fit on the robot. the enclosure of sensor is designed to protect against the radiant heat of the fire scene. We propose a single camera mode, thermal stereo mode, data fusion mode, and radar mode that can be used depending on the fire scene. Thermal stereo was effectively refined using an image segmentation algorithm, SLIC (Simple Linear Iterative Clustering). In order to reproduce the fire scene, three fire test environments were built and each sensor was verified.

소방전문자격사제도의 개선에 관한 연구 - 소방시설관리사를 중심으로 - (A Study on the Reformation of Certified Fire Fighting Specialists - Focused on Fire Protection System Managers -)

  • 오형근
    • 한국방재학회 논문집
    • /
    • 제6권4호통권23호
    • /
    • pp.21-28
    • /
    • 2006
  • 이 연구는 특정소방대상물의 소방시설에 대한 자체점검을 수행하는 소방시설관리사의 운용실태를 분석하고 개선방안을 제시하였다. 도시 공설소방서비스로 소방검사를 보완하는 자체점검을 수행하는 소방시설관리사를 대상으로 직무환경, 제도환경, 운용환경 등에 대해 설문조사를 실시하여 소방시설관리사제도의 운용실태에 대한 문제점을 실증적으로 파악하였다. 연구에 나타난 결과는 자체점검에 대한 법적 제도적 장치미비로 건물주와 소방검사원 그리고 소방시설관리사 상호간에 갈등이 있는 것으로 나타나 제도정착을 위해서는 상호보완 협력적 관계를 정립해야 할 것으로 나타났다.

The Analysis on Forest Fire Occurrence Characteristics by Regional Area in Korea from 1990 to 2014 Year

  • Jeon, Bo Ram;Chae, Hee Mun
    • Journal of Forest and Environmental Science
    • /
    • 제32권2호
    • /
    • pp.149-157
    • /
    • 2016
  • Understanding regional characteristics in forest fire occurrence is important to establish effective forest fire prevention policy in Korea. This study analyzed the characteristics of forest fires occurred in 16 administrative districts for recent 25 years (1990~2014) to examine regional characteristics in forest fire occurrence. Forest fire occurrence reflects regional characteristics depending on climatic factors as well as region's society-cultural factors. Results showed that the first cause of forest fire occurrence was carelessness by human activities throughout all administrative districts, however, the second cause depends on regional characteristics. As the results of forest fire occurrence period analyzed for 10 days, the most forest fires occurred in the southern region during January to March, while forest fires in the northern region occurred mostly during March to April. We classified forest fire occurrence patterns into three types (centralized: Gyeonggi-do, dispersal: Busan, horizontally distributed: Gyeongsangnam-do) by multi-temporal analysis for forest fire occurrence period.

소방공무원 근무환경에 대한 안전보건 의식 연구 (A Study on the Safety and Health Consciousness for the Working Environment of Fire Fighter)

  • 이종호;김요한
    • 한국안전학회지
    • /
    • 제30권1호
    • /
    • pp.137-143
    • /
    • 2015
  • Fire fighter are exposed to the situations which are hard to predict due to continuous and accidental changes which hinder their fire fighting activity. As these threats of safety accident act as fear factors, they are doing insecure fire fighting activities. Therefore, as unclear and abnormal risks of working environment such as the riskiness of expansion of disaster, instability, obstacles of activities, abnormality, urgency, etc. increase, safety accidents are caused. This study analyzes the actual condition of safety and health and awareness of fire fighter who are exposed safety accidents during their fire fighting activities and utilize such result as the basis data to secure safety of fire fighter, keep efficient safety control and prevent accidents. The results of analysis are as follows. As rescue works among all fire-fighting works shows the highest emotional stabilization and the highest post-traumatic stress disorder is shown in fire sergeant level positions, and fire fighters whose working period is 10-15 years, reinforcing safety training to long-term workers is necessary. As the result of survey regarding safety awareness, the highest awareness level was shown in fire sergeant level positions, and fire fighters whose working period is over 20 years, and when it comes to operation of fire fighting equipments, fire-fighting workers and workers having 1-4 years of working period showed high safety awareness. The more serious injury in a fire fighter experienced as the first injury after working as a fire-fighter, the more cause-and-effect relationship was shown between personal physical condition and work, and it is shown as obstacles of fire fighting activities and affects to post-traumatic stress disorder. Moreover, as after-work off duty activities also affect to official disaster, systematic improvement of working environment is required. Occupational medical work compatibility evaluation considering the distinct characteristics of works to secure fire-fighter' health care together with fire-fighting capability is shown to be necessary.

복층건물의 출입문 개방여부에 따른 화재온도분포 및 독성가스 농도 변화특성에 관한 연구 (A Study on Characteristics of Fire Temperature and Concentration of Toxic Gases while the Door Opening or Closed on Multi-layered Construction)

  • 이정윤;김정훈;김응식;김홍
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.72-77
    • /
    • 2017
  • In S. Korea, recently, building fire accidents of residential accommodations or recreational facilities have taken place more frequently than before. Among various building constructions, Multi-layered structure, such as office-residential complex, are mostly made in S. korea. $O_2$, $CO_2$, CO, $NO_x$, $SO_x$, and HCl, these gases has toxic hazard and harmful for human body. And it is predicted that different concentration of released gases from diesel pool fire with upper and lower layer. Therefore, this study reports the fire characteristics of Multi-layered structure by analyzing the fire behavior and concentration of combustion gases of a experimental compartment via real scale fire experiment, in order to predict risks and secure safety for similar fire accidents.

고무제품제조공장의 가류공정에 설치된 유도전동기의 설치환경 및 화재위험성 분석 (Analysis of Installation Environment and Fire Risk of Induction Motors Installed in the Curing Process of a Rubber Product Manufacturing Plant)

  • 이종찬;김두현;김성철
    • 한국안전학회지
    • /
    • 제38권2호
    • /
    • pp.23-29
    • /
    • 2023
  • This study analyzed the fire status of a rubber product manufacturing factory based on 19 years of fire data. Through the analysis of the current state of fire, electrical fires accounted for 58.19%, and among electrical fires, motor fires were the highest at 26.21%. For the motor fire occurrence process, the curing process accounted for the highest rate of 51.9%. Therefore, the installation environment was investigated for the motor in the curing process, and it was confirmed that the motor's maximum ambient temperature exceeded 40℃. In particular, in the case of the motor for curing operation, the motor was installed in a separate motor room, so the average indoor temperature was 48.10℃ and the motor frame's maximum temperature was 72.80℃. In this study, the risk of motor fire was confirmed through a field survey, and a safety management plan was derived by finding a process with high fire risk and conducting an experiment on the motor's installation environment and electrical characteristics in that process.