• Title/Summary/Keyword: fire disaster

Search Result 1,918, Processing Time 0.03 seconds

Measurement of the Device Properties of Fixed Temperature Heat Detectors for the Fire Modeling (화재모델링을 위한 정온식 열감지기의 장치물성 측정)

  • Park, Hee-Won;Cho, Jae-Ho;Mun, Sun-Yeo;Park, Chung-Hwa;Hwang, Cheol-Hong;Kim, Sung-Chan;Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.37-43
    • /
    • 2014
  • The high predictive performance of fire detector models is essentially needed to assure the reliability of fire and evacuation modeling in the process of Performance-Based fire safety Design (PBD). The main objective of the present study is to measure input information in order to predictive the accurate activation time of fixed temperature heat detectors adopted in Fire Dynamics Simulator (FDS) as a representative fire model. To end this, Fire Detector Evaluator (FDE) which could be measured the device properties of detector was used, and the spot-type fixed temperature heat detectors of two thermistor types and one bimetal type were considered as research objectors. Activation temperature and Response Time Index (RTI) of detectors required for the fire modeling were measured, and then the RTI was measured for ceiling jet flow and vertical jet flow in consideration of the install location of detectors. The results of fire modeling using measured device properties were compared and validated with the experimental results of full-scale compartment fires. It was confirmed that, in result, the numerically predicted activation time of detector showed reasonable agreement with the measured activation time.

Heat Transfer Characteristics on the High Speed Bullet Penetrated a Fuel Tank (고속충격탄의 연료탱크 관통시 열전달 특성)

  • Lee, Seung-Chul;Park, Young-Rok;Jeon, Woo-Chul;Lee, Hae-Pyeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.533-536
    • /
    • 2011
  • 본 연구에서는 차량 연료탱크에 충격탄 관통 시 화재발생 여부를 분석하기 위한 연구의 전단계로서, 충격탄 속도 변화에 따른 연료탱크 내부의 열전달특성을 분석하기 위해 전산유체역학기법을 도입하여 수치해석을 수행한 결과 다음과 같은 결론을 얻었다. 잔류속도 120m/s의 경우, 관통부를 지난 위치에서 최대온도는 약 324.8K를 나타내고 잔류속도 360m/s의 경우, 충격탄이 관통부로 유입되면서 급격하게 증가되어 최고온도 약 382.1K를 나타낸다. 이러한 결과로 미루어 최고 온도가 가솔린 연료의 착화온도보다 높아 화재의 위험성이 있지만 순간적인 온도변화가 심하고 착화시간이 만족되지 않을 것으로 판단된다.

  • PDF

Development of Crown Fire Propagation Probability Equation Using Logistic Regression Model (로지스틱 회귀모형을 이용한 수관화확산확률식의 개발)

  • Ryu, Gye-Sun;Lee, Byung-Doo;Won, Myoung-Soo;Kim, Kyong-Ha
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.1
    • /
    • pp.1-12
    • /
    • 2014
  • Crown fire, the main propagation type of large forest fire, has caused extreme damage with the fast spread rate and the high flame intensity. In this paper, we developed the probability equation to predict the crown fires using the spatial features of topography, fuel and weather in damaged area by crown fire. Eighteen variables were collected and then classified by burn severity utilizing geographic information system and remote sensing. Crown fire ratio and logistic regression model were used to select related variables and to estimate the weights for the classes of each variables. As a results, elevation, forest type, elevation relief ratio, folded aspect, plan curvature and solar insolation were related to the crown fire propagation. The crown fire propagation probability equation may can be applied to the priority setting of fuel treatment and suppression resources allocation for forest fire.

Estimation of Biomass Loss and Greenhouse Gases Emissions from Surface Layer Burned by Forest Fire (산불로 인한 지표층 연소량 및 온실가스 배출량 추정)

  • Lee, Byungdoo;Youn, Ho Jung;Koo, Kyosang;Kim, Kyongha
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.2
    • /
    • pp.286-290
    • /
    • 2012
  • Globally, the forest fires are a significant contributor of carbon dioxide and other greenhouse gases in the atmosphere. In this study, fuel load consumed by forest fire and emission of green house gases were analysed in the surface layer. For this, remaining fuel was collected and weighed with the species (Japanese red pine, deciduous) and the forest fire types (surface fire, crown fire) in the 51 forest fires. 8,361 kg/ha fuel load was consumed in deciduous forest damaged by surface fire, and 8,055 kg/ha, 12,333 kg/ha in Japanese red pine burned by surface fire and crown fire. The combustion ratios were 78, 59, and 90%, respectively. 15,856 kg/ha the green house gases such as $CO_2$, $CH_4$, $CH_4$ in deciduous forest burned by surface fire was emitted and 14,834 kg/ha, 22,709 kg/ha in Japanese red pine burned by surface fire and crown fire.

A Study on the Fire Protection Safety of the Public-utilization Shops (다중이용업소의 소방안전기준에 관한 연구)

  • Kim, Yeob-rae
    • Journal of the Society of Disaster Information
    • /
    • v.5 no.2
    • /
    • pp.10-21
    • /
    • 2009
  • This study contains the fire protection safety of the public-utilization shops. The toll of fires in the public-utilization shops is so heavy in spite the less occurency. The shops are mostly compartmented into small rooms by partition wall which hinders the evacuation of the people on fire. This study provides additional requirements on the fire safety of the public-utilization shops needed for human life and property.

  • PDF

Impact of Earthquake Response Perception on Fire officials on Organizational Citizenship Behavior (소방공무원의 지진 대응인식이 조직시민행동에 미치는 영향)

  • Kim, JeeYun
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.2
    • /
    • pp.343-352
    • /
    • 2020
  • Purpose: This study identifies the impact on composition of the firefighting organization, fire command ability, and public opinion operation on organizational citizenship behavior for fire officials to respond to the earthquake disaster, and provides practical implications as basic data for firefighting organizations to cope with the earthquake disaster. Method: Questionnaire survey was performed for 159 fire officials, and the surveyed data was statistically analyzed by using SPSS 22.0 program. Result: First, the results of the verification of the hypothesis showed that the composition of the fire organization, firefield command ability and public opinion operation have a positive impact on organizational citizenship behavior. Second, the relative contribution of independent variables to the dependent variables was identified in the order of composition of fire organization, fire command ability and public opinion operation. Conclusion: The implications of this study suggested from a practical perspective that the government needs to organize firefighting organizations, develop firefield command ability and operate public opinion in advance in order to respond to earthquakes.

Using AHP to Develop a Rehabilitation Room Management Model for Fire Officers at Disaster Sites (재난현장 소방공무원의 회복실 운영모델 개발)

  • Yim, Dong-Kyun;Chae, Jin
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.115-124
    • /
    • 2020
  • The purpose of this study was to provide an operational model of the rehabilitation room for fire officers at disaster sites to improve the safety and resilience of fire officers. Therefore, we analyzed the operation related elements of the rehabilitation room-such as overseas rehabilitation room operation cases and previous studies- and managed different factors including, but not limited to, management and human resources, equipment and facility, and accessibility and convenience factors; afterward, the relative importance and importance of sub-layers in each field were measured. The priority of items for the operation of the rehabilitation room for fire officers at disaster sites was elucidated; after expert analysis, it was found that human resources were the most crucial factor. Finally, it was found that, in descending order, accessibility and convenience, administrative, equipment, and facility factors were also essential. Based on this, we proposed a rehabilitation room operation guideline for disaster sites.

An Experimental Study on Temperature Measurement Bias using Thermocouple in Simulated Thermal Environments of Fire (모사된 화재의 열적환경에서 열전대를 이용한 온도 측정오차에 관한 실험적 연구)

  • Han, Ho-Sik;Yun, Hong-Seok;Hwang, Cheol-Hong;Kim, Sung-Chan
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.7-13
    • /
    • 2017
  • An experimental study was conducted to identify the quantitative measurement bias for the bare-bead thermocouple (TC), which was widely used for measuring temperature in fire experiments. To this end, an apparatus could be controlled individually gas flow rate, preheating temperature and incident radiative heat flux was developed to simulate the thermal environments of fire. A relative measurement bias of bare-bead TC was evaluated with the comparison of double-shield aspirated TC. As a result, the relative measurement bias of bare-bead TC was gradually increased with the increase in radiative heat flux with constant gas temperature. The relative bias was also significantly increased with the decrease in gas temperature. Quantitatively, at the gas temperature of $20^{\circ}C$, the bare-bead TC had the relative bias of approximately 400% with the radiative heat flux of $20kW/m^2$ corresponding to thermal radiation level of the flashover. The present study was intend to provide fire researchers with methodologies for the reanalyses of temperature measured using bare-bead TC, radiation corrections, and validation of fire modeling.

A Study on the Statistical Analysis of Fire Patterns in Seoul Metropolitan Region (통계적 방법을 이용한 수도권지역의 화재유형분석에 관한 연구)

  • Sin, Jae-Wook;Kim, Hae-Rim;Park, Young-Ju;Lee, Hae-Pyeong;Moon, Kyong-Ae
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.424-428
    • /
    • 2010
  • 본 연구에서는 통계적 분석방법을 이용하여 수도권지역(서울특별시, 인천광역시, 경기도)의 화재발생 유형에 대한 분석을 통하여 체계적이고 효율적인 소방정책을 수립하기 위한 기초 자료를 확보하는데 주안점을 두었다. SPSS와 Clementine 프로그램을 이용하여 소방방재청 국가화재정보시스템의 2007년과 2008년 화재발생 자료를 대상으로 기초통계분석(교차분석, 빈도분석)을 비롯하여 의사결정트리 분석 등을 수행하였다. 분석결과로서, 수도권지역의 화재건수는 2007년 이후부터 감소하거나 유지하는 경향을 보이고 있으며, 화재유형은 50% 이상이 건축/구조물에 의한 것으로 나타났다. 또한, 인명피해를 보면 서울시는 다른 수도권지역과 달리 2007년 대비 2008년 부상자와 사망자 수가 감소하였으며, 재산피해의 경우, 서울을 비롯한 대부분의 수도권지역에서 감소한 것을 확인할 수 있었다.

  • PDF