• Title/Summary/Keyword: fire detection/emergency

Search Result 46, Processing Time 0.026 seconds

Design of Emergency Fire Fighting and Inspection Robot Riding on Highway Guardrail

  • Ma, Xiaotong;Li, Xiaochen;Liu, Yanqiu;Tao, Xueheng
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.6
    • /
    • pp.833-843
    • /
    • 2022
  • Based on the problems of untimely Expressway fire rescue and backward traditional fire rescue methods, an emergency fire fighting and inspection robot riding on expressway guardrail is designed. The overall mechanical structure design of emergency fire fighting and inspection robot riding on expressway guardrail is completed by using three-dimensional design software. The target fire detection is realized by using the target detection algorithm of Yolov5; By selecting a variety of sensors and using the control method of multi algorithm fusion, the basic function of robot on duty early warning is realized, and it has the ability of intelligent fire extinguishing. The BMS battery charging and discharging system is used to detect the real-time power of the robot. The design of the expressway emergency fire fighting and inspection robot provides a new technical means for the development of emergency fire fighting equipment, and improves the reliability and efficiency of expressway emergency fire fighting.

Introduction of Intelligent fire-disaster Surveillance System for Subway Station (도시철도 역사 지능형 화재감시시스템 구축방안 연구)

  • Shin, Jeong-Ryol;An, Tae-Ki;Jeon, Bo-Ik;Kim, Gab-Young;Kim, Hyung-Min;Yun, Byeong-Ju
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.457-465
    • /
    • 2009
  • Subway system including light-rail transit system is the representative public urban transportation. Accordingly, Nothing is more important than the safety operation as well as passengers' convenience. Due to the fire disaster of Daegu subway on 2003, more strict regulations of detecting fire and of conducting on emergency circumstances. However, regardless of this improved management, it was reported that installations of lots of fire-detection facilities may be harm than good to operate subway system due to frequent malfunction of some fire-detection facilities. It may cause mis-alarm for fire and induces abnormal operation of subway due to the strict regulation; the train shall be stopped on emergency circumstances. Therefore, in this paper, new scheme on surveiling breaking-out-of fire in the station is suggested with new IT technologies, Wireless Sensor Network(WSN) and CCTVs. which were integrated with an intelligent software. This intelligent system enables to surveil breaking-out-of fire in real time through sensor network technology and watch the emergency site on CCTV as well. Through this system, subway organizers could cope with the emergency circumstance rapidly as well as judge precisely whether fire breaks out or not.

  • PDF

Radio Frequency Based Emergency Exit Node Technology

  • Choi, Youngwoo;Kim, Dong Kyoo;Kang, Do Wook;Choi, Wan Sik
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.2 no.1
    • /
    • pp.91-100
    • /
    • 2013
  • This paper introduces an indoor sensor fusion wireless communication device which provides the Location Based Service (LBS) using fire prevention facility. The proposed system can provide information in real time by optimizing the hardware of Wi-Fi technology. The proposed system can be applied to a fire prevention facility (i.e., emergency exit) and provide information such as escape way, emergency exit location, and accident alarm to smart phone users, dedicated terminal holders, or other related organizations including guardians, which makes them respond instantly with lifesaving, emergency mobilization, etc. Also, the proposed system can be used as a composite fire detection sensor node with additional fire and motion detect sensors.

Development of a Novel Real-Time Monitoring System Algorithm for Fire Prevention (화재예방을 위한 실시간 모니터링 시스템의 알고리즘 개발)

  • Kim, Byeong-Jo;Kim, Jae-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.5
    • /
    • pp.47-53
    • /
    • 2014
  • Despite the automatic fire alarm system, according to the national fire data system of national emergency management agency, the fires account for 40,932 incidents, 2,184 injuries and about 430 billion won in property losses in 2013. Since the conventional automatic fire alarm system has several weaknesses related to electrical signal such as noise, surge, lighting, etc. Most fires are mainly caused by electrical faults, mechanical problem, chemical, carelessness and natural. The electrical faults such as line to ground fault, line to line fault, electrical leakage and arc are one of the major problems in fire. This paper describes the development of a novel real-time fire monitoring system algorithm including fault detection function which puts the existing optic smoke and heat detectors for fire detection with current and voltage sensors in order to utility fault monitoring using high accuracy DAQ measurement system with LabVIEW program. The fire detection and electrical fault monitoring with a proposed a new detection algorithm are implemented under several test. The fire detection and monitoring system operates according to the proposed algorithm well.

Simulation Analysis of Safety Evacuation in University Experiment Building

  • Tao Zhang;Ha-Sung Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.2
    • /
    • pp.218-226
    • /
    • 2024
  • According to the actual situation of a university, the emergency evacuation simulation is modeled based on the physical sign, evacuation speed and personnel ratio using the pathfinder software.The experimental construction export utilization rate is compared with the preliminary simulation scenario. The simulation results show that the utilization rate of evacuation stairs and evacuation exits is significantly improved.The optimized solution can provide the most effective evacuation passage, and the research results can provide the basis for the rational planning and management of evacuation passage in university experiment building.

A Plan of Existing System Interface within Station (역사내 기존 시스템 인터페이스 방안)

  • Lee, Won-Jae;An, Tae-Ki;Shin, Jeong-Ryol
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1550-1555
    • /
    • 2011
  • This paper presents the system interface standard that are associated with additional devices like sensor nodes as well as fire monitoring panel, panic button and emergency call in city railroad environment. Existing fire monitoring panel, panic button and emergency call system is responsible for fire detection and alarm, emergency alarm and communication with the manager. Recently, researches that are associated with NVR-based intelligent integrated surveillance systems and existing alarm system are activated but most of the system is dedicated to it existing. In order to expand devices that is supported other monitoring function, separate device configuration or modification of integrated surveillance system are inevitable. In this study, interface standard between standard controller, integrated command center and each device that facilitate additional expansion of integrated surveillance system and avoid the extra cost is presented.

  • PDF

A Study on the Prevention of Fire Korean in Waste Facilities

  • Jang-Oh Kim;Kyong-Jin Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.4_1
    • /
    • pp.722-733
    • /
    • 2024
  • According to the National Fire Agency, there are 1,810 waste recycling facilities, 2,094 waste treatment facilities, and 223 waste minimization facilities in Korea. Waste fires are characterized by high severity and are prone to reignition, and it is difficult to timely detect them. Waste fires consequently demand many firefighters, equipment, and time to extinguish. Notwithstanding this reality, waste is excluded from the category of special combustible materials in the Act on Installation and Management of Firefighting Systems, 2021 (the Act). Therefore, this study proposes that special combustible materials, including waste, should be incorporated into the Act, that fire detectors and photoelectric smoke detectors should be installed to enable early detection of fires, and that the use of water and foaming agents as firefighting equipment should be enforced.

Analysis on the Impact of Draft Curtains on Hospital Building Fires

  • Xiaopei Liu;Hasung Kong
    • International journal of advanced smart convergence
    • /
    • v.13 no.3
    • /
    • pp.367-375
    • /
    • 2024
  • Draft curtains are an important tool to reduce the spread of fire smoke in buildings. This paper mainly studies the influence of draft curtains on smoke spread in a hospital outpatient building with a spacious hall. The outpatient building of a county hospital in China is taken as the research object, and a fire simulation model is established based on PyroSim software. Four scenarios are designed: no draft curtains in the hall, draft curtains with a length of 1.5m in the hall, draft curtains with a length of 2.0m in the hall, and draft curtains with a length of 2.5m in the hall. At the same time, considering the worst situation, only the main emergency exit is opened, while the remaining emergency exits and windows are all closed, and the fire-fighting facilities are not activated. The detection point is set at the open emergency exit, 1.8m above the ground. Through the simulation of four scenarios, the effect of draft curtains on smoke spread is discussed from four aspects: smoke layer height, temperature, visibility, and CO concentration. The results show that draft curtains have a significant impact on the spread of smoke in a hospital outpatient building with a spacious hall. The longer the draft curtains are, the better the smoke-blocking effect. It should be noted that in the actual design, the length of the draft curtains should be considered without affecting the evacuation of personnel.

Design and Implementation of a Real-time Automatic Disaster and Information Broadcasting System (시뮬레이션 프로그램 기반 실시간 자동재난 및 안내방송시스템의 설계)

  • Lee, Byung-Mun;Park, Jung-In;Kang, Un-Gu
    • Journal of Digital Convergence
    • /
    • v.10 no.7
    • /
    • pp.141-152
    • /
    • 2012
  • The typical evacuation guidance system based on fire detectors, which is being widely used in theaters and large buildings, is often operated in an analog manner. In case of fire, it often causes the system to lose a wired line or wireless fire detection sensor, resulting in the difficulty of transmitting signals from a wired or wireless fire detection sensor to the main fire monitoring device. Accordingly, this paper has proposed the broadcasting system for disaster management, having an efficient evacuation guidance plan when a disaster occurs. The system reacts to an emergency situation along with fire alarm sirens in real time. We have implemented the above system by means of a simulation program that prints the evacuation guidance information (e.g., location and time of fire, and evacuation path) on an LCD located in a building through the fire sensor network in case of an emergency (e.g., actual fire). We have developed the simulation system by using mathematical algorithms, such as the optimal path search and the fire smoke diffusion algorithm. This simulation program considers the structure of a building and the location where the fire has initially occurred, applying it to the simulator.

A Study on Design and Operation Performance of Automatic Fire Detection Equipment (P-type One-class Receiver) by Bidirectional Communication (양방향 통신이 가능한 자동화재탐지설비(P형 1급 수신기)의 설계 및 동작특성에 관한 연구)

  • Lee, Bong-Seob;Kwak, Dong-Kurl;Jung, Do-Young;Cheon, Dong-Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.347-353
    • /
    • 2012
  • In this paper, authors will develop the quick and precise remote controller of automatic fire detection equipment (P-type one-class receiver) based on information communication technology (IT). The remote controller detects the fire and disaster in the building automatically and quickly and then activates the facilities to extinguish the fire and disaster, monitoring such situation in a real time through wire-wireless communication network. The proposed remote controller is applied a programmable logic device (PLD) micom. of one-chip type which is small size and lightweight and also has highly sensitive-precise reliabilities. The one-chip type PLD micom. analyzes digital signals from sensors, then activates fire extinguishing facilities for alarm and rapid suppression in a case of fire and disaster. The detected data is also transferred to a remote situation room through wire-wireless network of RS232c and bluetooth communication, and then the situation room sends an emergency alarm signal. The automatic fire detection equipment (AFDE) based on IT will minimize the life and wealth loss while prevents fire and disaster.