• 제목/요약/키워드: fire control time

검색결과 356건 처리시간 0.03초

스캔라인 알고리즘을 이용한 대화력전 임기표적의 실시간 영역 결정 (Real-time Processing for Target of Opportunity Positioning of Counter-fire with Scan-line Algorithm)

  • 전기윤
    • 한국군사과학기술학회지
    • /
    • 제10권2호
    • /
    • pp.148-151
    • /
    • 2007
  • The CF(Counter-fire) is neutralizing enemy's all command control systems and fire support elements. It will weaken a battle continuous ability and an intension to fight. At the beginning of the CF is obtaining locations of targets using various detection assets. CF command center processes acquired target information and send it to attacking equipments. The targets are classified into two classes, preplanned target and target of opportunity The target of opportunity is potential threaten, so it needs to take a immediate and exact process for determining location of target of opportunity. This paper proposes the real-time processing algorithm for offensive weapons to strike target of opportunity, and presents the result of its performance.

화재 피해를 입은 고 강도 철근콘크리트 휨 부재의 구조 거동 (Structural Behavior of Fire-Damaged Reinforced Concrete Beam with High Strength Concrete)

  • 신미경;신영수;이차돈;홍성걸;이은주
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.635-638
    • /
    • 2003
  • This paper deals with structural behavior of reinforced concrete beams with high strength under fire and fire damaged condition. The main purpose of this study is to evaluate the residual strength of flexural members by exposure time to fire. For this purpose, six beam specimens are fabricated and experimented. Among the specimens, four specimens are exposed to the fire for 60 and 90 minutes and two specimens are control beam that is not exposed to fire. After being cooled in room temperature, the specimens are loaded to the failure. The research result shows that the main variables of the test, concrete cover and exposure time to fire are much influenced on the structural behavior and the residual strength.

  • PDF

스크린도어 설치에 따른 지하승강장 제연의 문제점과 대책 - 부산 지하철 3호선을 중심으로 - (Smoke Control in a Subway Station Platform with Screen Doors - Based on Busan Subway Line 3 -)

  • 박외철
    • 한국화재소방학회논문지
    • /
    • 제20권1호
    • /
    • pp.50-54
    • /
    • 2006
  • 스크린 도어로 격리된 지하철 역 승강장의 제연의 문제점을 조사하고 그 대책을 마련하기 위해 승강장 일부에 대하여 수치해석을 수행하였다. 바닥면적 $40m{\times}5m$, 높이 3m의 구역에 1 MW의 화재가 발생하고 배기방식의 제연설비가 작동하는 것으로 가정하였다. 세가지 배기풍량 0.1, 2.0, $4.0m^3/min-m^2$에 대해 온도와 연기의 농도, 일산화탄소의 농도, 가시거리의 분포를 비교하였다. 또 배기풍량에 따른 제연성능을 알아보기 위해 무작위분포 입자수의 시간 변화율도 조사하였다. 급기풍량이 적은 경우에는 공기의 공급부족으로 제연에 시간이 많이 소요되는 것으로 나타났다. 화재시에는 선로에서 승강장으로 자연급기가 가능한 구조로 하여, 제연이 효율적으로 이루어지게 할 필요가 있으며, 기존의 부산 지하철 3호선 지하역 승강장에는 비상시에 화재가 완전히 소화될 때까지 승강장과 선로간의 문을 개방해두는 것이 바람직함을 확인하였다.

방화셔터를 이용한 아트리움 제연과 피난안전에 관한 수치해석 연구 (A Numerical Study for the Atrium Smoke Control by Fire Shutter and Evacuation)

  • 전흥균;최영상;추홍록
    • 한국화재소방학회논문지
    • /
    • 제24권5호
    • /
    • pp.50-59
    • /
    • 2010
  • 본 연구에서는 대구 D대학 기숙사 건물에 대해 2MW, 5MW 화재크기와 아트리움 방화셔터의 미설치 및 작동 경우의 4가지 화재시나리오를 구성하고, FDS(ver. 5.5.0)와 Pathfinder 2009 프로그램을 사용하여 화재 및 피난시뮬레이션을 수행하였다. 화재피난영향평가를 통하여 방화셔터와 배연구의 아트리움 제연 효과에 대한 성능을 확인하였고, 화재위험 및 피난안전을 분석하였다. 방화셔터의 작동은 연기 전파 방지에 큰 효과가 있지만, 상부 배연구를 통한 배연량이 불충분하여 방화셔터의 유무에 관계없이 연기층은 바닥으로부터 약 2m 지점까지 하강하고, 본 연구에서 설정한 연기층 한계 높이 이하가 되었다. 또 방화셔터 미설치, 5MW 화재크기의 경우, 온도보다 가시거리에 의한 화재위험 가능성이 더 크게 나타났고, 기숙사 중.상부 층의 계단실 피난여유시간은 약 5초 이내로 매우 작았다. 지상 1층 주출입구까지 전체 피난자의 순수 피난이동시간은 136초이다. 피난자의 더 안전한 피난을 위해 추가적인 보완조치가 필요하다고 사료된다.

표적추적센서의 측정 바이어스 오차 보상에 의한 사격통제장치 성능 향상 기법 (A performance improvement method in the gun fire control system compensating for measurement bias error of the target tracking sensor)

  • 김재훈;유준
    • 한국군사과학기술학회지
    • /
    • 제3권2호
    • /
    • pp.121-130
    • /
    • 2000
  • A practical method is proposed to improve hit probability of the digital gun fire control system, when the measured rate of the tracking sensor becomes biased under some operational situation. For ground moving target it is shown that the well-known Kalman filter which uses position measurement only can be optimally used to eliminate the rate bias error. On the other hand, for 3D moving aircraft we present a new algorithm which incorporate FIR-type filter, which uses position and rate measurement at the same time, and the fixed-lag smoother using position measurement only, and show that it has the optimal performance in terms of both estimation accuracy and response time.

  • PDF

동해안 대형 산불피해지의 사방사업 실태진단 (The investigation of erosion control works' condition in East sea fire area)

  • 염규진;전근우;차두송;이시영;이현규;이명욱;김윤진;이진호;김석우;강기차부
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.509-512
    • /
    • 2007
  • The fire area need management to prevent enlargement of collapes and sinkage. and it need that repair Vegetation sack work, Soil arresting structure, Terrace-sodding works, Direct seeding works in greening works and Water cushion in erosion control dam. The whole of the Concrete stream grade stabilization structures were broken, it need to be repair. As pass the time, a lot of structures were abandoned. Therefore, it need to reorganize erosion control structures and the method of construction in the fire area

  • PDF

포배열카메라 영상을 활용한 함포 사격통제시스템의 동적배열오차 분석 및 보정방법 (Study on Analyzing and Correction of Dynamic Battery Alignment Error in Naval Gun Fire Control System by using Image of Boresight Telescope)

  • 김의진;서태일
    • 한국군사과학기술학회지
    • /
    • 제16권6호
    • /
    • pp.745-751
    • /
    • 2013
  • In naval gun firing, firing accuracy comes from the combination of each component's accuracy in CFCS (Command and Fire Control System) like tracking sensors and gun. Generally, battery alignment is done to correct the error between gun and tracking sensor by using boresight telescope on harbor and sea. But normally, the battery alignment can compensate only the static alignment error and ignore dynamic alignment error which is caused by own ship movement. There was no research on this dynamic alignment error until now. We propose a new way to analyze dynamic arrangement error by using image of boresight telescope. In case of the dynamic alignment error was due to time delay of own ship attitude information, we propose the way to compensate it.

선박화재시 피난 안전성 연구 (A Study on the Safety Evacuation of Onboard Fire)

  • 김원욱;김창제;채양범
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2010년도 춘계학술대회
    • /
    • pp.59-60
    • /
    • 2010
  • 선박화재는 육상과 달리 숙련된 인원과 다양한 장비에 의한 소화활동이 곤란하며 거의 자체적인 진화작업을 수행해야하므로 소화가 쉽지 않다. 화채는 일반적으로 화염에 의한 인명사고 보다 매연에 의한 질식사의 확률이 높으므로 인명사고 방지하기 위해서는 신속한 초기 진화가 가장 중요하다. 하지만 여러 가지 이유로 부득이 소화가 지연되거나 불가능할 경우에는 화재 구역으로부터 신속한 탈출만이 인명사고를 방지할 수 있다. 이 연구에서는 CFD기법을 이용한 시뮬레이션을 통하여 선박화재시 탈출에 지장이 되는 매연농도를 측정하고 피난시간과 비교하여 적절한 피난이 가능한지에 대한 안전성을 검토하고자 한다.

  • PDF

소방용수시설의 공설소화전 종류에 따른 사용 준비시간 비교분석 (Comparison Analysis of Ready to Use Time Depending on The Type of Public Fire Hydrant of Fire-fighting Water Facility)

  • 전재인;공하성
    • 문화기술의 융합
    • /
    • 제5권4호
    • /
    • pp.87-92
    • /
    • 2019
  • 이 연구는 공설소화전에 대한 지상식 및 지하식 소화전의 소방용수 사용 준비시간을 분석하였다. 1단계인 장비 준비시간은 지상식은 20.50초, 지하식은 24.67로 나타났다. 이와 같이 준비시간이 다소 차이가 난 것은 지하식 소화전은 맨홀 뚜껑을 개방하는 빠루와 지하식 소화전 본체 관구에 연결하기 위하여 스탠드 파이프가 추가로 필요했기 때문이다. 2단계인 물탱크차의 보수구에 숫커플링의 수관결합은 지상식은 48.50초, 지하식은 49.00초로 비슷하게 나타났다. 이것은 물탱크차 보수구에 소방호스를 연결하는 동작이 같기 때문이다. 3단계인 본체 관구에 수관 결합은 지상식은 43초, 지하식은 174.33초로 나타났는데 이와 같이 수관을 소화전 관구에 연결하는 시간이 큰 차이가 난 것은 지하식 소화전은 맨홀 뚜껑을 개방한 후 소화전 본체 관구에 스텐드 파이프를 연결한 후에, 스텐드 파이프 관구에 수관을 결합하는 추가 과정이 필요하여 소요시간을 크게 올린 것으로 판단된다. 4단계인 제수 밸브와 스핀들 개방은 지상식은 66.50초, 지하식은 78.83초 소요되었다. 이 같은 차이가 난 것은 지상식 소화전의 스핀들은 본체 관구위에 위치하여 쉽게 개방이 가능하지만, 지하식은 맨홀 아래 관구 옆에 위치하여 개방 장비인 복스퍼너를 연결하는 추가시간이 필요하여 나타난 결과로 판단된다.

네트워크 GR형 수신기와 컨트롤데스크를 이용한 통합방재관리시스템에 대한 연구 (The Study on the Integrated Emergency Management System using Network GR-type Receiver and Control Desk)

  • 백동현;송호빈;강원선
    • 한국화재소방학회논문지
    • /
    • 제26권1호
    • /
    • pp.96-101
    • /
    • 2012
  • 근래의 건축물들은 고층화와 지하 심층화되고 있어 화재 발생 시 대형 사고의 가능성이 매우 높으므로 여러 장소에 개별적으로 설치되어 있는 화재수신기의 방재정보를 통합하여 관리할 필요가 있다. 본 논문에서는 각각 떨어진 장소에 설치된 화재수신기에 대해 원격으로 감시 및 제어 가능하며 인터넷과 광케이블로 연결 할 수 있는 네트워크형 화재수신기와 컨트롤데스크를 제작한 다음 각 장치 간에 화재발생 및 이상상태를 감시하고 상황에 따라 모니터링, 경보, 제어 및 유지관리를 수행 할 수 있는 통합관리시스템을 개발하였다. 제안한 시스템을 국가검정기준에 의하여 평가하고, 각 구간의 신호 전달 시간에 대해 실험을 수행하여 성능의 안정성을 확인하였다.