• Title/Summary/Keyword: fire and heat

Search Result 1,620, Processing Time 0.023 seconds

Characterization of Live Fire Load in Buildings - Heat Release Characteristics of Typical Live Fire Load in Post Office Building - (건축물의 적재가연물 특성에 관한 연구 -우체국 적재가연물의 연소성상 -)

  • Nam, Dong-Gun;Yuji, Hasemi;SaKong, Seong-Ho;Jung, Jong-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.7-10
    • /
    • 2008
  • Heat release characteristics of live fire load are an important parameter for performance oriented fire safety design of a building. While investigations have been carried out on the fire load and its burning behavior in office, residential and commercial buildings and so on, little effort has been paid for the rational treatment of fire load in post office buildings in Japan. In this report, burning behavior of typical combustible objects in post office buildings are studied by measuring heat release rates of plastic palettes with and without postal envelopes or packages and special containers loading numbers of palettes. The test results suggest that dynamic heat release rate is highly dependent on the condition of palettes especially if they load appropriate amount of postal envelopes or not.

  • PDF

The literatual study on the therapy for clearing away heat with apoplexy therapy (중풍(中風)의 치료(治療)에 있어 청열법(淸熱法)에 대(對)한 문헌적(文獻的) 고찰(考察))

  • Kang, Hwa-Jeong;Moon, Byung-Soon
    • Korean Journal of Oriental Medicine
    • /
    • v.2 no.1
    • /
    • pp.26-39
    • /
    • 1996
  • The literatual study on the therapy for clearing away heat with apoplexy therapy, the result were obstained as follows. 1. In apoplexy therapy, therapy for clearing away heat is used excessive heart - fire by overacting of the five emotions, liver fire, deficiency of kidney - fluid, wind - heat. 2. The fire of aetiology of apoplexy is used therapy for clearing away eat, in aspect of viscera and bowels, divied into heart - fire, liver - fire, deficiency fie of kidney yin, wetness - phlegm of spleen heat. The treatment is clear away heart - fire, clear away liver - fire, clear away spleen - heat and sthenic water. 3. Symptom of excessiveness symptom - complex is used therapy for clearing away heat that are fever, flushed face, halitosis, heart burn, easy anger, apoplestic stroke, unconsciouness, trismus, paralysis, constipation, red tongue with yellow coat, taut - smooth pulse or full - rapid pulse and symptom of insufficiency symptom - complex that are dizziness, tinitus, blurring of vision, deficiency sleeping, dreaminess, lassitude of the loins and legs, hemiplegia, red tongue with white coat or thin - yellow coat taut - thready - rapid pulse. 4. Therapy for norish vital essence - clearing away heat is availed in excessive fire caused by deficiency of yin of the liver and kidney, therapy for break through phlegm - clearing away heat in stagnant heat therapy for waking up a patient from unconsciousness - clearing away heat in yang type sthenia - syndrom of coma of apoplexy involving viscera and bowels. 5. Commonly used recipes of therapy for clearing away heat are Yang gyolksan(凉膈散), Bang pongtongseongsan(防風通聖散), Sotongseongsan(小通聖散), Jibodan(至寶丹), Supungsungisan(搜風順氣散), Woowhangchengshimwhan(牛黃淸心丸), Chengungsekgong(川芎石膏湯), Samwhatang(三化湯) etc in excessiveness symptom- complex, and are Yukmijiwhangweon(六味地黃元), Jiwhangtang(地黃湯), Palmiji whangtang(八味地黃湯), Samultanggagam(四物湯加減) etc in insufficiency symptom - complex.

  • PDF

A Numerical Study on the Effect of Volume Change in a Closed Compartment on Maximum Heat Release Rate (밀폐된 구획실의 체적변화가 최대 열발생률에 미치는 영향에 관한 수치해석 연구)

  • Yun, Hong-Seok;Nam, Dong-Gun;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.19-27
    • /
    • 2017
  • The effects of changes in area and location of fire source, fire growth rate, and volume of compartment on the major fire characteristics, including heat release rate, in closed compartment fires were examined. To this end, a fire simulation using Fire Dynamics Simulator (FDS) was performed for ISO 9705 room with a closed opening. As main result, it was found that the changes in the area and location of fire source did not significantly affect the thermal and chemical characteristics inside the compartment, such as maximum heat release rate, total heat release, maximum temperature at upper layeras well as species concentrations. However, increasinthe fire growth rate and volume of compartment resulted in increase of the maximum heat release rate and total heat release, decrease in the limiting oxygen concentration and increase in the maximum CO concentration. Finally, a methodology for the application of fire growth curves to closed compartment fires was proposed by deriving the correlation of the maximum heat release rate expressed as a function of the fire growth rate and the volume ratio of compartment based on the ISO 9705 room.

A Study on Ignition and Fire Risks of Electric Heat Wire (전기적 열선의 발화 및 화재 위험성에 관한 연구)

  • Min, Se-hong;Song, Byeong-jun
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.113-121
    • /
    • 2015
  • This study aims to examine the risk of electrical fire in places where electric heat wires are used. In general, the use of electric heating wires is becoming more common and prevalent in a bid to prevent increasing damage caused by freezing and bursting in residential water pipes, factory pipes and irrigation pipes in vinyl greenhouse and a variety of heat wire products are available in market with legal safety requirements imposed on them. However, the widespread use of anti-freezing burst heat wire products has caused increasing incidents of fire, which often fail to be incorporated into statistics due to quick onsite extinguishing and insignificant damage although damage is gradually on the rise. Against this backdrop, this study aims to look into the possibility of ignition caused by electric heat wires and the mechanism of how it turns into catching fire through overheat and short circuit tests for anti-freezing burst electrical heat wires (hereinafter called the 'heat wire') and expects to serve as the basis for further observations and analyses on the cause of fire and the process of ignition in a scientific manner.

Correlation Study between the Changes of the Fire- and Heat- Related Symptoms and Motor Function Recovery in Acute Cerebral Infarction Patients (급성기 뇌경색 환자의 화열증상 변화와 기능회복도간의 상관관계에 대한 연구)

  • Hyun, Sang-Ho;Min, Kyung-Dong;Yei, Young-Chul;Kang, Ah-Reum;Lee, Eun-Chan;Moon, Sang-Kwan;Cho, Ki-Ho;Jung, Woo-Sang;Park, Sung-Wook;Ko, Chang-Nam
    • The Journal of Internal Korean Medicine
    • /
    • v.34 no.4
    • /
    • pp.428-437
    • /
    • 2013
  • Objectives : The aim of this study was to examine if there is a significant correlation between the changes of Fire- and Heat- related symptoms and motor function recovery in acute cerebral infarction patients. Methods : We studied inpatients within a month after the onset of cerebral infarction who were admitted at Kyunghee University Medical Center from May 2011 to January 2013. We executed correlation analysis between Fire-heat pattern score and motricity index score at visit 1 and visit 2, and checked if there was a significant correlation between the changes of Fire-heat pattern score and changes of motricity index score. Also, we compared the changes of both scores in patients taking Fire-heat and non Fire-heat pattern prescriptions. Results : There was a significant correlation between the Fire-heat pattern score and Motricity index score at visit 1 and visit 2, and changes of Fire-heat pattern score showed significant correlation with changes of motricity index score. Patients taking Fire-heat pattern prescriptions showed significant change in Fire-heat pattern score after herb-medication treatment while patients taking non-Fire-heat prescriptions showed insignificant change in Fire-heat pattern score. Conclusions : This study provides evidence that taking a Fire-heat pattern prescription could be considered as a first line herb-medication treatment in acute cerebral infarction patients.

Heat Release Characteristics of Typical Live Fire Load in Large Bookstore (대형서점 적재가연물의 초기 연소발열성상)

  • Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.88-94
    • /
    • 2011
  • Heat release characteristics of live fire load are an important parameter for performance oriented fire safety design of a building. While investigations have been carried out on the fire load and its burning behavior in office, residential and commercial buildings and so on, little effort has been paid for the rational treatment of fire load in bookstore. In this report, burning behavior of typical combustible objects in bookstore are studied by measuring heat release rates of bookshelf with book. Based on the results, it has reviewed fire safety when a fire accident occurs on the large bookstore and suggested peak heat release rate per burning surface, fire growth rate, etc of the live fire load required for fire safety design in bookstore.

Analysis of a Fire Case Caused by Heat Generation due to Cu2O Breeding (아산화동증식 발열에 의한 화재 사례의 분석)

  • Park, Jin-Young;Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.54-63
    • /
    • 2020
  • Although fires caused by heat generation due to Cu2O breeding in wire connections are well-known among fire investigators, there are few papers on the analysis and introduction of fire cases by heat generation due to Cu2O breeding. This study analyzed fire statistics caused by heat generation in electrical connections and the phenomena and features of heat generation due to Cu2O breeding. Then, a fire which occurred in the wire connection in a university lab by heat generation due to Cu2O breeding was analyzed in more detail. This fire case could reach a conclusion that heat generation due to Cu2O breeding caused a fire in the wire connection through the fire pattern investigation of fire origin, the visual investigation of wire connection, 3D CT, power-on-test, and stereoscopic microscopy, SEM and EDS analysis.

A study on the fire performance and heat transfer of the HPC column with fiber-cocktail in ISO fire under loading condition

  • Kim, Hyung-Jun;Kim, Heung-Youl;Kwon, In Kyu;Kwon, Ki-Hyuk;Min, Byung-Yeol;Cho, Bum-Yean
    • Computers and Concrete
    • /
    • v.12 no.5
    • /
    • pp.717-737
    • /
    • 2013
  • In this study, experiment and numerical analysis were conducted to identify the heat transfer characteristics and behavior of high-strength concrete upon a fire. The numerical analysis was employed to forecast the characteristics and properties of the high-strength concrete upon a fire, which can not be accomplished through a fire test due to the specific conditions and restrictions associated with the test. The result of the numerical analysis was compared with that of the test to verify the reliability of the analysis. In the numerical analysis of the heat transfer characteristics and behavior of 80 and 100 MPa high-strength concrete upon a fire, the commercial software of ABAQUS(V.6.8) was used. It was observed from the experiment that the contraction of the concrete with fiber-cocktail was mitigated by 25~55 % compared with that without fiber-cocktail because the fiber controlled the heat transfer of the concrete and thus improved the fire-resistance performance of the column.

A Study on the Fire Impact of Adjacent Storage at Outdoor Storage Fire (옥외저장소 화재 시 인접 저장소 화재 영향에 대한 연구)

  • Eun-Ji Kim;Sung-Seek Park;Yong-Han Jeon
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.3
    • /
    • pp.93-100
    • /
    • 2024
  • Outdoor storage fires have a significant impact on the surrounding environment, including adjacent storage facilities and buildings. Therefore, it is essential to review and manage the fire impact to minimize damage to human life and property on the outdoor storage fires. In this study, the heat release rate and radiant heat flux were simulated according to the fire time, wind veolcity, and presence or absence of water spray equipment in an outdoor storage facility fire, and the fire impact was analyzed. The outdoor storage was designed to simulate two scenarios on the outdoor storage fires containing gasoline, and FDS was used for fire simulation. As a results, when the water spray facility was not operating and the wind velocity was 5 m/s, the maximum radiant heat flux was 24.80 kW/m2, which exceeded the limit radiant heat flux of 20 kW/m2. When the water spray facility was operating and the wind veolcity was 10 m/s, the maximum radiant heat flux was 18.77 kW/m2, which did not exceed the limit radiant heat flux, indicating that the fire impact on adjacent storage facilities was relatively small.

Characteristics of Heat Flux in a Compartment Fire - Reduced Scale Test (구획공간 화재의 열유속 특성 - 축소 실험)

  • Kim, Sung-Chan;Ko, Gwon-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.128-133
    • /
    • 2011
  • The present study performs a series of 40 % reduced scale of ISO-9705 fire test to investigate the characteristics of heat flux on the floor level in terms of fire characteristics and location in the compartment. The heat flux was measured with Schmidt-Boelter type heat flux gauge at two locations on the floor level of inside and doorway side of the compartment. Different types of fuel - methane, heptane, toluene, ethanol, polystyrene - were burned in this test series. The measured heat flux inside of the compartment was relatively higher than that of front side as the heat release rate of fire and upper layer temperature increased. The difference of measured heat flux at inside and doorway side increased for high sooty fire. The present study shows that the heat flux distribution at lower layer greatly depend on the thermal radiation from fire and upper layer, not only the upper layer temperature but also various fire characteristics such as composition of combustion gases, soot concentration, ventilation condition and so on.