• Title/Summary/Keyword: fire accidents

Search Result 754, Processing Time 0.031 seconds

Studies on Fire-Retardant-Treatment and Press Drying of Plywood (합판(合板)의 내화처리(耐火處理)와 열판건조(熱板乾燥)에 관(關)한 연구(硏究))

  • Lee, Phil-Woo;Kim, Jong-Man
    • Journal of the Korean Wood Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.5-37
    • /
    • 1982
  • Plywood used for construction as a decorative inner material is inflammable to bring large fire accidents and burn out human life and their properties. To diminish the fire disaster, fire retardant plywood has been required indeed. In the methods of manufacturing the fire retardant plywood the soaking method is occasionally used. However after soaking plywood into fire retardant chemical solutions, redrying of soaked plywood is the most important. In this study, 3.5mm thin and 5.0mm thick plywoods were selected for fire retardant treatment. Treating solutions were prepared for 20% dilute solutions of ammonium sulfate, monoammonium phosphate, diammonium phosphate, borax-boric acid and minalith, and water solution. 1-, 3-, 6-, and 9 hour-soaking treatments were applied and after treatments hot plate drying was applied to those treated plywoods at $90^{\circ}C$, $120^{\circ}C$ and $150^{\circ}C$, of press temperature. Drying rates, drying curves, water absorption rates of fire retardant chemicals, weight per volume and fire retardant degree of plywood were investigated. The results may be summarized as follows: 1. The plywoods treated with ammonium sulfate, monoammonium phosphate and diammonium phosphate and diammonium phosphate showed increase of chemical absorption rate with proportion to increase of treating time, but not in case of the plywood treated with borax-boric acid and minalith. 2. In the treatment of definite time, the absorption rate per unit of volume of plywood showed higher in thin plywood (thickness of 3.5mm) than in thick plywood (thickness of 5.0mm). In both thin and thick plywoods, the highest absorption rate was observed in 9 hour-treatment of ammonium sulfate. The value was 1.353kg/$(30cm)^3$ in thin plywood and 1.356kg/$(30cm)^3$ in thick plywood. 3. The volume per weight of plywood after chemical treatment increased remarkably and. after hot plate drying, the values were to a little extent higher than before chemical treatment. 4. The swelling rates of thickness in chemical-treated plywoods increased similarly with that of water-treated plywood in 1- and 3 hour-treatment of both thin and thick plywoods. But in 6- and 9 hour-treatment, the greater increased value showed in water-treated ply wood than any other chemical, especially in thick plywood. 5. The shrinkage rates after hot plate drying showed the same tendency as the swelling rate, and the rate showed the increasing tendency with proportion to increase of treating time in thick plywood of both chemical and water treatments. 6. Among drying curves, the curves of water-treated plywood placed more highly than chemical-treated plywood without-relation to thickness in 6- and 9 hour-treatment except in 1- and 3 hour-treatment. 7. The drying rate related to thickness of treated plywood, was twice above in thin plywood compared with thick plywood. 8. The drying rate remarkably increased with proportion to increase of the plate temperature and, the values were respectively 1.226%/min., 6.540%/min., 25.752%/min. in hot plate temperature of $90^{\circ}C$, $120^{\circ}C$, $150^{\circ}C$ in thin plywood and 0.550%/min., 2.490%/min, 8.187%/min, in hot plate temperature of $90^{\circ}C$, $120^{\circ}C$, $150^{\circ}C$ in thick plywood. 9. In the treatment at $120^{\circ}C$ of hot plate temperature, the drying rates of chemical-treated plywood showed the highest value in monoammonium phosphate of thin plywood and in diammonium phosphate of thick plywood. But the drying rate of water-treated plywood was highest in 6- and 9 hour-treatment. 10. The fire retardant degree of chemical-treated plywood was higher than that of the untreated plywood as shown in loss of weight, burning time, flame-exhausted time and carbonized area. 11. The fire-retardant effect among fire retardant chemicals were the greatest in diammonium phosphate, the next were in monoammonium phosphate and ammonium sulfate, and the weakest were in borax-boric and minalith.

  • PDF

A Spatial Analysis about Arrival Delay and Dispatch Distribution of the 119 Rescue-Aid Service utilizing GIS - Gyeongsangbuk-Do Case Study - (GIS를 활용한 119 구조구급서비스의 도착지체 및 출동배치에 대한 공간분석 - 경상북도 사례 연구 -)

  • Oh, Chang-Seok;Lee, Seungwon;Lee, Inmook;Kho, Seung-Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.1D
    • /
    • pp.13-22
    • /
    • 2012
  • The 119 emergency rescue-aid service operated by Korean government is a very valuable in a society and its importance is growing in Korea as an aging society. Especially, the emergency vehicle's arrival time to accidents place is an important variable which affects initial emergency measure for patients and it depends on the road network attributes, such as emergency service station's location, accessibility to accidents place and so on. This study aims to analysis the emergency vehicles' arrival delay and the dispatch station in the viewpoint of efficiency utilizing the real rescue-aid activity data. We analyzed the dispatch distribution of the emergency rescue-aid service at first. And we analyzed high accident rate locations not involved in the fixed radius of rescue-aid service stations and display GIS map showing regions have been delayed. The input data of the road network speed is based on the KTDB (Korea Transportation Database) and historical rescue-aid data is from Gyeongsangbuk-do's fire service headquarters.

Awareness of disaster and post traumatic stress disorder in occupational therapy students (재난 및 외상 후 스트레스장애에 대한 작업치료 전공자의 인식조사)

  • Hong, Young-Ho;Cho, Su-Bin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.539-547
    • /
    • 2017
  • This study examined the perception of disasters and post-traumatic stress disorder in occupational therapy majors to provide the basic data necessary for future occupational therapy. A questionnaire survey was conducted on 545 students in occupational therapy departments of three year and four year universities. The frequency of the questionnaire was calculated by frequency analysis using the SPSS 19.0 win program. A chi-squared test was conducted to verify the analyzed questionnaire data. The reliability of the questionnaire in this study showed a Cronbach' alpha value of 0.891. According to the survey results, approximately 20% of learners who majored in occupational therapy were unaware of the symptoms, developmental mechanism, and diagnostic criteria of post-traumatic stress disorder(PTSD). Knowledge of the underlying causes of psychological symptoms, such as post-traumatic stress disorder as well as physical damage through industrial accidents, was found to be 2.92 on the Likert 5-point scale. To be effective in rehabilitation treatment, the degree of the approach to education from the viewpoint of occupational therapy is important enough to be recognized as 3.90 on the Likert 5-point scale. The Pearson correlation coefficient for the need for education on disasters was higher than the correlation with the awareness of disasters.

Legal Approach to the Passage Issues of the Cheju Strait (제주해협 통항문제에 관한 법적 고찰)

  • Kim Hyun Soo
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2003.11a
    • /
    • pp.35-44
    • /
    • 2003
  • Considering possible legal and policy problems with regard to the Cheju Strait, a central issue is whether the Cheju Strait should be treated as Korean territorial sea or an international strait The claim that the strait is territorial sea has been based on the use of a straight baseline method of dermarcation With the use of straight baseline, Korea claims that the breadth of the Cheju Strait is only 20.7 miles at its narrowest point and therefore the strait becomes the territorial sea of Korea. The consideration cf marine pollution has weighed heavily in claiming the Cheju Strait as territorial sea. Pollution resulting from the accidents cf tankers caused by fire, collision, or stranding in the Cheju Strait and the Korea Strait would be enormous, affecting the entire coastal waters of the south coasts cf Korea's mainland and Japan's Tsushima Islands areas. Catastrophic pollution in the Cheju Strait could also come from the accidents cf large-size oil tankers passing through the Korea Strait from the Malacca Strait Although the Korean government considers the geographic and socioeconomic conditions sufficient to justify Korea's claim of the Cheju Strait as territorial sea, it believes that declaring it so would raise considerable legal conflicts with maritime states. In view of the legal difficulties and the need to meet the problems arising from the growing vessel traffic in the Cheju Strait, the sea lanes and traffic separation schemes may be considered an alternative to the internationalization of the Cheju Strait Even if the Korean government dose not do so, the regime of innocent passage should be applied to vessels passing through the Strait and should not suspend innocent passage through the Strait. Therefore, the Korean government needs to have a more legal, pragmatic, functional and managerial approach than a purely sovereign and selfish approach to the solution of legal matters of the Cheju strait For this purpose, the UN Convention on the Law of the Sea would serve as a guide and also self-restraint and cooperative approaches would become norms governing the resolution of the law of the sea issues in the Cheju Strait.

  • PDF

A Study on Pricing Criteria of the Laboratory Safety Inspection and Diagnosis (연구실 점검 및 진단 대가기준에 관한 연구)

  • Lee, Jong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.5
    • /
    • pp.170-176
    • /
    • 2018
  • Laboratory inspection and diagnosis is a means of investigating and assessing various hazards or the state of research equipment in a laboratory, then taking appropriate safety measures to prevent accidents and injury. In many cases, laboratory inspection and diagnosis carried out by agencies are performed in a perfunctory manner that only barely satisfies the legal requirements. The aim of the present study is to provide clearly established pricing criteria for laboratory inspection and diagnosis, so as to prevent recurrence of laboratory accidents and to establish a safe laboratory environment. In order to clarify previously unclear matters, such as the lower limit for bids submitted by laboratory inspection and diagnosis agencies, technical manpower requirements, and number of laboratories inspected and diagnosed per day, a questionnaire survey was administered to agency personnel. First, when asked what the lower limit for bids submitted by agencies should be in order to improve reliability of inspection and diagnosis results and make up for the shortcomings of the lowest-bidder-wins system, 85.5% of respondents answered that the lower limit for bids should stand at no lower than 90% of the estimated price. The level of technical expertise among the technical personnel committed to laboratory inspection and diagnosis was shown to impact the reliability of results, and questionnaire results indicated a need to vary technical expertise levels depending on the degree of hazard, substances handled, and equipment used in a given laboratory. Level of technical expertise(67.1%) and number of personnel(52.6%) were shown to have a greater impact on reliability of diagnosis than on reliability of inspection. According to the results, it is determined that three persons(specialist, advanced and intermediate) should be committed to inspections, while four persons(professional, specialist, advanced and intermediate) should be committed to diagnoses. The respondents indicated a larger number of laboratories could be inspected than diagnosed per day. This can be attributed to differences in the amount of work each task involves, and the time each task takes. Assuming a six-hour work day not counting transportation, paperwork and rest, it is thought that inspection of up to 36 laboratories will be possible if each laboratory is assigned no more than 10 minutes(34.7%), while up to 24 laboratories could be inspected and diagnosed if each laboratory is assigned 15 to 20 minutes(35.1%).

The present condition analysis of patients who transferred to the emergency room by 119 Rescue service at night - Focused on the Emergency Center of Chonnam National University Hospital - (119 구급대를 이용하여 야간에 응급실로 내원한 환자 현황 분석 - 전남대학교병원 응급의료센터를 중심으로 -)

  • Yoon, Jonggun;Kim, Gunnam;Kim, Kyungwan;Jeong, Yongtae
    • The Korean Journal of Emergency Medical Services
    • /
    • v.8 no.1
    • /
    • pp.117-126
    • /
    • 2004
  • In general, the patients who transferred to the hospital by 119 rescue service at night go to the emergency room(ER) of general hospital rather than that of their nearby the 1st(clinic) and 2nd(local hospital) hospital. And the hospital is mainly selected not by 119 EMST but by patients or his/her conservators. Therefore we had studied retrospectively with emergency situation diary and medical chart for 697 patients of being transferred to one emergency medical center for 6 months since January 2004, and results are as follows. 1. The 280 patients(42.5%) of being transferred hospital at night by 119 rescue service were not emergency case and their average staying time in hospital was about $7.15{\pm}10.06$ minutes. 2. Transfer time was distributed in each time intervals of 1819, 2021, 2223, and 2401 and patients ratio in each intervals were 15.1%, 17.8%, 16.4%, and 15.2%. 3. In response of ambulance, the average time from the spot to the hospital was $14.53{\pm}9.27min$. and average distance of that was $7.95{\pm}9.21km$. 4. Diseases rather than traffic accidents or traumatic injury were main causes of ambulance calling and its value was 533(76.5%), and accidents were mainly occurred in patients' house and its value was 479(68.7%). 5. In time of transfer by 119 rescue service, hospital was mainly selected by patient/conservator and its value was 648(93.0%). In result. the hospital was selected not by EMST but by patient/conservator. 6. The case that the 1st grade EMT was rode in ambulance was 161(23.1%), and the case that 2nd EMT and emergency team member who educated for emergency were rode in ambulance were 504(72.3%). So the number of the 1st grade EMT was short in fire station of Kwangju metropolitan city than other city. 7. The first aids for patients before reaching hospital were limited to oxygen inhalation, airway control, and BLS for maintaining limbs and spine. So it seems to be a simple patients transfer. Consequently, to establish an efficient emergency medical system, it has been thought that it should be advanced a moderate education and public information about the appropriate use of emergency medical system toward citizen, and also need the hospital selection by the patients categorizing standards for 119 rescue service member, securing the 1st grade EMT, appropriate first-aids education, and securing professional human power in emergency room of the Ist(clinic) and 2nd(local hospital) hospital at night.

  • PDF

Analysis of Monitored Insulation Data Using Standard Deviation of Leakage Current Data in High-Power Cables at a Thermoelectric Power Station (화력발전소 고전력 케이블의 누설 전류 측정 데이터의 표준 편차값을 사용한 절연감시 데이터 분석)

  • Kim, Bo-Kyeong;Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.2
    • /
    • pp.245-250
    • /
    • 2017
  • From the instant of installation and operation, power cables start deteriorating. Cable systems can be maintained not only by monitoring the insulation status of the insulation layer and oversheath, but also the insulation status of the terminal and junction in high-voltage power cables. When the cable system (the cable itself and cable junctions combined) deteriorates, fire accidents happen due to dielectric breakdowns. We have invented a device to monitor the deteriorating status of cables, and installed it at Korea Western Power Co. Ltd. located in Taean, Chungcheongnam-do Province. In this paper, we present the results obtained using our device, through analysing and calculating the standard deviation of leakage current from cable insulators attached to the cables. When the standard deviation of analysed leakage current falls below a critical value, a cable system is deemed to be operating safely. But when the standard deviation of analysed leakage current is larger than the critical value, the insulation status of the terminal and junction in the cable system is considered to have seriously deteriorated. The terminal and junction in the relevant system should then be replaced preemptively in order to prevent blackout accidents of cables caused by the suspension of power supply.

Psychosocial Interventions for Children and Adolescents after a Disaster: A Systematic Literature Review (1991-2015) (재난 후 소아청소년의 정신사회적 개입: 체계적 문헌고찰(1991~2015))

  • Lee, Mi-Sun;Hwang, Jun-Won;Lee, Cheol-Soon;Kim, Ji-Youn;Lee, Ju-Hyun;Kim, Eunji;Chang, Hyoung Yoon;Bae, Seung-Min;Park, Jang-Ho;Bhang, Soo-Young
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.27 no.4
    • /
    • pp.278-305
    • /
    • 2016
  • Objective: The aim of this systematic literature review is to analyze the psychosocial interventions for children and adolescents after disasters. Methods: We conducted a review of the extant research literature from 1991 to 2015 via a comprehensive search of the MEDLINE, EMBASE, Cochrane CENTRAL, PubMed and PsyclNFO databases. The keywords employed in this research included: 'child', 'adolescent', 'youth', 'disaster', 'posttraumatic', 'psychosocial', 'therapy' and 'intervention'. The researchers followed the PRISMA guidelines. A total of 850 articles were screened for their eligibility and fifty-nine were found to meet the study criteria. The final data analysis was performed based on the disaster type, study design, type of intervention, sample size, age, school grade, number of sessions, setting of intervention delivery, providers, approach and parent involvement. Results: Countries worldwide have experienced various kinds of disasters, including earthquakes, hurricanes, vessel accidents, tornados, tsunamis, volcanic eruptions, war, fire, terrorism, and traffic accidents. The types of psychosocial intervention that were conducted after these disasters included: psychological first aid, psychological debriefing, psychoeducation, trauma focused cognitive behavior therapy, eye movement desensitization reprocessing, prolonged exposure therapy, group play therapy and arts therapy, project interventions, school-based interventions and web-based interventions. Conclusion: The findings of the systematic literature review suggest that an appropriate psychosocial intervention could be utilized as evidence-based mental health treatment for children and adolescents after disasters.

A Study on the Status Investigation for Establishing the Disaster Management Cooperation System at Educational Institutions (교육기관의 재난관리 협력체계 구축을 위한 실태조사 연구)

  • Park, Soyeon;Koo, Wonhoi;Baek, Minho
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.3
    • /
    • pp.405-412
    • /
    • 2017
  • Due to the increase in awareness of school safety after the Sewol ferry disaster, it became necessary to improve the capability to prevent a safety accident at school and to respond to an accident in the case of emergency as well as the awareness of safety issues. Therefore, it is necessary for educational institutions to reinforce safety measures autonomously, and the importance of supports and cooperation from agencies related to the safety of local community is also emphasized. However, it is quite difficult for schools and the Office of Education to prevent safety accidents only with their own capability, and safety accidents can be prevented through the supports from agencies involved in safety of local communities. Therefore, the status and cooperation system of educational institutions and relevant authorities were reviewed theoretically in this study. In addition, a field investigation was carried out to examine the awareness of disaster and safety, and cooperation status of officials in charge of practical disaster-related works. Moreover, this study intended to present a measure to establish the safety cooperation system between educational institutions and agencies involved in safety of local community in the future based on the findings.

Development of FCEV accident scenario and analysis study on dangerous distance in road tunnel (도로터널에서 수소차 사고시나리오 개발 및 위험거리에 대한 분석 연구)

  • Lee, Hu-Yeong;Ryu, Ji-Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.659-677
    • /
    • 2022
  • Hydrogen is emerging as a next-generation energy source and development and supply of FCEV (hydrogen fuel cell electric vehicle) is expected to occur rapidly. Accordingly, measures to respond to hydrogen car accidents are required and researches on the safety of hydrogen cars are being actively conducted. In this study, In this study, we developed a hydrogen car accident scenarios suitable for domestic conditions for the safety evaluation of hydrogen car in road tunnels through analysis of existing experiments and research data and analyzed and presented the hazard distance according to the accident results of the hydrogen car accident scenarios. The accident results according to the hydrogen car accident scenario were classified into minor accidents, general fires, jet flames and explosions. The probability of occurrence of each accident results are predicted to be 93.06%, 1.83%, 2.25%, and 2.31%. In the case of applying the hydrogen tank specifications of FCEV developed in Korea, the hazard distance for explosion pressure (based on 16.5 kPa) is about 17.6 m, about 6 m for jet fire, up to 35 m for fireball in road tunnel with a standard cross section (72 m2).