• Title/Summary/Keyword: fire accident

Search Result 697, Processing Time 0.065 seconds

Vulnerability Analysis on Fire Service Zone using Map Overlay Method in GIS (GIS 기반 중첩기법을 이용한 소방서비스 취약지역 분석)

  • Lee, Seul-Ji;Lee, Ji-Yeong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.1
    • /
    • pp.91-100
    • /
    • 2011
  • Fire stations should be located in optimal location to act quickly in case of emergency and minimize damages as a public facility that protects life and property of local residents. Siting fire stations without regard for the accessibility and occurrence factors of an accident may provide fire service unequally. Therefore service analysis is necessary to reduce the blind spot of disaster and safety and to offer equal fire-service at this time. Especially fire stations can service more efficiently than before by reducing a more likely vulnerable area. This study suggests methods of mapping index of value that represents vulnerability of the occurrence of an accident and extracting service zone map of fire stations, as an initial research for offering efficient fire service. Geographical distribution mismatch between service zone map and vulnerability map is figured out and vulnerable area for fire service is defined by using map overlay method.

The Comparative Analysis of Passenger Evacuation Results Using CFAST and FLUENT (CFAST 와 FLUENT 화재유동해석을 통한 승객피난 시뮬레이션 결과 비교분석)

  • Jang, Yong-Jun;Park, Won-Hee;Jung, Woo-Sung;Lee, Chang-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1354-1361
    • /
    • 2007
  • The evacuation simulation study was performed with the boundary condition of a fire simulator, referring to Dae-gu Subway Fire Accident which was a real station fire. The subway station was modelled from B3F station building to B2F waiting room in fire simulation. Also, a fire simulation were performed with CFAST and FLUENT. In CFAST, the total 29 zones were divided into 18 station buildings in B3F and 11 station buildings in B2F. In FLUENT, the simulated space had the same establishment as zone of CFAST. The study focused on possibility for application of fire simulation in underground station by comparing the resulted values from two simulators. For application of fire effect, the fire data were loaded directly to EXODUS in the case of CFAST and performed a passenger evacuation simulation. In the case of FLUENT, Out Data values of a fire simulation were difficult to be compatible with EXODUS. Two resulted values of passenger evacuation simulation by fire simulation were compared with the Dae-gu Subway Fire Accident in reality.

  • PDF

A Study on the Safety Measures of Fire Protection in Hotel Buildings (호텔건축물의 방화안전대책에 관한 연구)

  • 안태용;이영재
    • Fire Science and Engineering
    • /
    • v.15 no.2
    • /
    • pp.80-90
    • /
    • 2001
  • It is expected that hotel buildings will be large-scale, luxurious and multiplex according to the needs of modern functions. In addition, building users, who are many and unspecified persons, are short of information on the buildings, so that they may be injured or killed at the occurrence of fire accident. Therefore, in order to overcome such problems, hotel buildings need systematic fire protection facilities concerning particulars to pay attention to the safety on a fire and an evacuation. This study has investigated the following matters. First, it examined hotel use records, statistics relevant to fire accidents, a case investigation related to fire accidents, survey on actual performance of fire protection awareness. Second, it investigated the design planning matters of hotel buildings. Third, it demand to amend the law and regulations related to physical Protection after analyzing them. The purpose of the study is to protect human being and properties at the occurrence of fire accident, and to present basic material for design of hotel buildings to minimize damages and losses.

  • PDF

Methods of Ensuring Safety for Integrated Fire Protection Shutters at Elementary and Middle Schools (초등학교 및 중학교의 일체형 셔터 안전성 확보 방안)

  • Youn, Hae-Kwon
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.36-45
    • /
    • 2016
  • Integral fire shutters are installed indiscriminately, regardless of evacuation. There is always the risk of an accident because integral shutters are applied mainly to corridors, passages, and stairs of schools This study evaluated the problem of integral shutter's entrance, evacuation, construction management, and maintenance control through a fire shutter accident case, including present condition of fire shutter installed at school of Okgil, Bucheon and Dongtan, Hwaseong. The results suggest that emergency lighting or signs for passage be set up to check location of entrance easily and install obstruction sensors at fire shutter to reduce life damage. In addition, the number of efficiency tests of fire shutters should be increased by running a trial test monthly or weekly to maintain the performance of fire shutter. Schools need to install a fire shutter- applied sprinkler at the entire floor.

A Study on the Safety Regulation Revision for Urban Transit Vehicles (도시철도차량의 안전기준 강화에 관한 연구)

  • Lee Woo-Dong;Shin Jeong-Ryol;Kim Gil-Dong;Han Suk-Youn;Park Kee-Jun;Hong Jai-Sung;Ahn Tai-Ki;Lee Ho-Yong;Kim Jong-Wook
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.322-326
    • /
    • 2003
  • Dae-gu subway accident raise whole points in connection with safety facilities and operating of national urban transit system like rolling stocks, facilities, management of human. Rolling stock is made every effort for improvement of performance, guarantee of comfortableness, insurance of economical efficiency. But Security like safety of fire is not thoroughgoing enough. Especially, interior material has used although it is not prove its degree of safety. it is a main cause of Dae-gu subway accident. Safety regulation of urban transit vehicle that legislate for security in March 2000 does not applied manufacturing vehicles before in 2000. It has be prescribed in the regulations that incombustibles must be used. But detailed test standard related with incombustibles is not prescribe. Thus that regulation be required reinforcement of detailed test standard. Main cause of Dae-Gu subway accident is a fire in vehicle. However, many defects are found in infrastructure and operating vehicle of urban transit, such as inexperienced disposal of driver and CCC in early stage of the fire accident, unskilled opening and closing doors, insufficient escape facilities and safety facilities of a station house and tunnel, and incomplete communication system between vehicle and CTC, extraordinary step. Thus the aims of this study are prevention of urban transit accident, improvement plan of safety driving, and proposal of quick action plan through analysis of total faculty of vehicle.

  • PDF

Analysis of Parameters Affecting the Consequence of the Flash Fire Accident by the Release of Heavy Gas (무거운 가스의 누출에 의한 플래쉬화재사고에서 사고결과에 미치는 매개변수의 영향 분석)

  • Kim, Tae-Ok;Lee, Hern-Chang;Ham, Byeong-Ho;Cho, Ji-Hoon;Shin, Dong-Il;Jang, Seo-Il
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.6
    • /
    • pp.29-39
    • /
    • 2006
  • The effect of parameters on the consequence of the flash fire accident by the release of heavy gas(in this study, xylene vapor) was analyzed. Simulation results showed that the distance with the lower flammable limit($X_{LFL}$) was increased with the increase of the release hole diameter. For the case of the elevated release, $X_{LFL}$ was increased with the increase of the wind speed and the release height, but $X_{LFL}$ was not affected by the wind speed for the release on the ground level. Therefore, the accident in the elevated release was more dangerous than the release on the ground level. In this condition, the release height had more effect on $X_{LFL}$ at the night time than the daytime and in the urban area than the rural area.

A Study on Fire Scenario Analysis Based on Fire Statistics for Building Fire Risk Analysis (건축물 화재위험평가를 위한 화재통계 기반 화재시나리오 분석에 관한 연구)

  • Jin, Seung-Hyeon;Kim, Hye-Won;Koo, In-Hyuk;Kwon, Yeong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.81-82
    • /
    • 2022
  • This study aims to establish a methodology for rational fire risk assessment for building evacuation safety in case of fire, and specifically, to propose a fire risk assessment technique using fire scenarios considering various uncertain factors in case of fire. In order to analyze the extent to which the assumed conditions can occur, that is, the probability of each accident caused by fire, the safety rate is analyzed according to the presence or absence of each factor by using fire statistics. Factors related to the fire protection performance and evacuation ability of buildings are defined as disaster factors. In this study, disaster factors were classified into the following three categories.

  • PDF

Accident Prevention Counterplen of the Elevator for the Passenger (승객용 승강기의 재해예방에 관한 연구)

  • Kwon, Oh-Heon;Go, Seong-Seok;Yun, Yu-Seong
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.2
    • /
    • pp.106-111
    • /
    • 2002
  • Recently the car and elevator accidents as well as the fire, explosion and collapse increased. The passenger elevator accident from 1993 year to 2001 year has about 56.7% of total accidents and the human victims of 180 according to the Korea Elevator Safety Institute. Accident cause and prevention were investigated for the elevator having the fall, impact and narrowness accident types. The prevention and protection methods of the elevator accident from analysis results were suggested by comparing and analogizing the accident statistics about the accident investigation of the passenger elevator according to the elevator accidents.

A Case study on the plan for the ESC integrating optimized train operation system for Fire & power failure accident in subway (도시철도 화재$\cdot$단전시 최적 열차운행을 위한 통합운영체계 구축방안에 관한 연구)

  • Kim Young-Wook;Choi Se-Wan;Kim Young-Kyu
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1185-1192
    • /
    • 2004
  • Recently heavy traffic is getting worse because increasing population of transportation in urban area. In order to solve this problem. subway is realized with high speed, high density, highly efficiency. When fire accident happened in Dae-Gu subway in February 2003, there happened loss of people and lots of damage because of not being able to control even though fire alarm which was set up in the station rang. This thesis has constructed a simulation integrating operation system using a Database construction, operating program analysis in order to build up the most efficient train operation system. The result of simulation integrating operation system with emergency virtual situation like station and train fire, train failure, power line failure, all trains running on the rail were secured safety by train operation control system. With integrating operation of each train control system, train system, power system, machine facility system, the most efficient integrating operation system should have been constructed at the time the subway fire and power failure broke out.

  • PDF

A Study on the Risk of Organic Solvents for Underground Area under Construction Site through a Fire Accident Case (화재사고사례를 통해서 본 건설현장 지하공간에서의 유기용제의 위험성에 대한 연구)

  • Ahn, Byung-Joon;Jung, Ki-Hyuk;Lee, Jung-Suk;Rhim, Jong-Kuk
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.1
    • /
    • pp.9-17
    • /
    • 2018
  • In the consideration of the working conditions, which have several kinds of works operating at the same time, at construction sites, it is difficult to prevent industrial accidents. There are a number of works to employ flammable materials and hot works simultaneously operated without fire protection systems. It causes a huge fire and casualties. In this research to analyze an accident case, the reasonable prevention methods are suggested throughout the property tests for the organic solvents and the analysis of the behavior for vapour cloud in the underground area of the construction site.