• Title/Summary/Keyword: finned tube

Search Result 159, Processing Time 0.022 seconds

Heat Transfer Characteristics of a Circular Fin-tube Heat Exchanger (원형휜-원형관의 열전달 특성)

  • 강희찬;조동영;강민철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.9
    • /
    • pp.762-767
    • /
    • 2003
  • An experimental study was conducted to investigate the heat transfer characteristics of a circular finned-tube heat exchanger. The nineteen cases of configuration varying fin material, fin outer diameter and fin pitch were tested by means of the experiment and the numerical calculation. The measured heat transfer data for the circular finned-tube heat exchanger were provided. A transition of heat transfer was found in the case of low fin pitch. The thermal conductivity of fin affected on the pure heat transfer coefficient.

Coupled Heat and Mass Transfer in Absorption of Water Vapor into LiBr-$H_2O$ Solution Flowing on Finned Inclined Surfaces

  • Seo, Taebeom;Cho, Eunjun
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.7
    • /
    • pp.1140-1149
    • /
    • 2004
  • The absorption characteristics of water vapor into a LiBr-H$_2$O solution flowing down on finned inclined surfaces are numerically investigated in order to study the absorbing performances of different surface shapes of finned tubes as an absorber element. A three-dimensional numerical model is developed. The momentum, energy, and diffusion equations are solved simultaneously using a finite difference method. In order to obtain the temperature and concentration distributions, the Runge-Kutta and the Successive over relaxation methods are used. The flat, circular, elliptic, and parabolic shapes of the tube surfaces are considered in order to find the optimal surface shapes for absorption. In addition, the effects of the fin intervals and Reynolds numbers are studied. The results show that the absorption mainly happens near the fin tip due to the temperature and concentration gradient, and the absorbing performance of the parabolic surface is better than those of the other surfaces.

Finned Tube Heat Exchanger for Air Conditioning System (공조기용 Finned Tube 열교환기)

  • 김무환
    • Journal of the KSME
    • /
    • v.35 no.9
    • /
    • pp.776-793
    • /
    • 1995
  • 인간이 쾌적한 환경을 요구하는 수준과 함께 개발 및 개선되어 온 공조용 finned tube 열교환 기에 대한 연구는 앞으로도 환경과 소형화 및 정숙 운전의 요구에 부응하기 위하여 지속적인 연구 및 개선이 요구될 것이다. 또한, 생산기술이 발달함에 따라 이에 적합한 새로운 형태의 경 제적이고 효율적인 열교환기의 설계가 필요할 것이다. 특히 앞으로 중요성이 더욱 강조될 환경 오염, 재료의 재활용 등의 측면은 현재 우리가 개척해야 할 분야일 것이다. 한편으로는 국내의 짧은 열교환기 개발의 역사에 의하여 지금까지 사용되어 온 외국의 기술 및 특허 등의 무 제에 대하여 국내 고유의 기술을 보유할 수 있도록 더욱 노력을 하여야 할 것이다. 나아가 실제 열 교환기에서의 확장표면의 효과, 냉동유의 영향 그리고 혼합냉매의 열전달 특성 등을 고려할 수 있는 상관식을 개발함으로써 국내의 열교환기 설계기술이 외국에 비하여 우위를 점할 수 있도록 하는 노력이 계속되어야 할 것이다. 그리고 미래까지 이러한 기술적 우위를 지속하기 위해서는 혼합냉매의 상변화 열전달현상의 기본 메카니즘을 밝히는 등의 열교환기에서의 열유동특성에 대한 기초적인 연구와 새로운 형태의 열교환기 개발 및 전기장을 이용한 열전달 촉진 등의 신 기술을 이용한 열전달 연구 등에 대한 투자와 관심이 지속되어야 한다.

  • PDF

Heat Transfer Optimization in a Tube with Circular-Sectored Fins (원관내 부채꼴 휜 주위에서의 열전달 최적화)

  • Yoo, Jae-Wook;Kim, Sung-Jin;Hyun, Jae-Min
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.57-64
    • /
    • 2000
  • The present work investigates the heat transfer characteristics for laminar fully developed forced convection in an internally finned tube with axially uniform heat flux and peripherally uniform temperature through analytical models of convection in a porous medium. Using the Brinkman-extended Darcy flow model and the two equation model fur heat transfer, analytical solutions fur fluid flow and heat transfer are obtained and compared with the exact solution for fluid flow and the numerical solutions for conjugate heat transfer to validate the porous medium approach. Using the analytical solutions, parameters of engineering importance are identified and their effects on fluid flow and heat transfer are studied. Also, the expression fur total thermal resistance is derived from the analytical solutions and minimized in order to optimize the thermal performance of the internally finned tubes.

  • PDF

Design of Annular Finned Heat Transfer Tube Using Robust Optimization (원형 확장 휜 열 교환기의 치수 강건최적설계)

  • Jhong, Woo-Jin;Yoon, Ji-Won;Lee, Jong-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.9
    • /
    • pp.1437-1443
    • /
    • 2003
  • Most optimization problems do not consider tolerance of design variables and design parameters. Ignorance of these tolerances may not fit for the practical problems and can lead to an unexpected conclusion. That is why we suggest robust optimization considering tolerances in both design variables and problem parameters. Using robust optimization, we designed minimum weight annular finned heat transfer tube subject to constraints on limitation of pressure difference and minimum value of total heat transfer. Consequently, robust optimization satisfies tolerance considered practical problems.

Heat Transfer Characteristic of Finned-tube Heat Exchangers with Different Clearance between Fin Collar and Tube Surface (핀칼라와 튜브의 간극에 따른 열교환기의 열전달 특성)

  • Park, Young-Min;Jeong, Young-Man;Lee, Jae-Keun;Park, Nae-Hyun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1073-1078
    • /
    • 2009
  • Finned-tube heat exchangers are often made with aluminum fins and copper tubes. Usually the contact between fin collar and tube surface for finned tube heat exchanger is secured by mechanical expansion of the tubes. The objective of the present study is to apprehend how much effect clearance has on the performance of heat exchanger. This effect is studied using an experimental approach. The thermal fluid measurements are made using a psychometric calorimeter. Frontal air velocity varies in the range from 1.0m/s to 3.0 m/s. The heat transfer rate of sample which has bigger clearance is only 27% compare with the other's in dry condition. In wet condition, its heat transfer rate is 78% compare with the other's.

  • PDF

Performance Characteristic of Large Diameter Oval Finned-Tube Heat Exchanger for Dryer (건조기용 타원관 대구경 핀-관 열교환기의 성능특성)

  • Bae, Kyung-Jin;Cha, Dong-An;Kwon, Oh-Kyung
    • Journal of Power System Engineering
    • /
    • v.18 no.5
    • /
    • pp.22-27
    • /
    • 2014
  • The objectives of this paper are to obtain an empirical equations regarding the correlations between heat transfer and pressure drop of oval fin-tube heat exchanger having large diameter using wilson plot method. It was difficult to find any recommendable heat transfer and friction factor correlation available for our large diameter experimental cases. Overall heat transfer coefficients are composed of the heat transfer coefficients both inside and outside tubes. The resulting empirical correlations for the Nui and f-factor are given as $Nu_i=0.0146Re^{0.809}Pr^{0.3}$ and $f=4.366Re^{-0.64}$, respectively. The empirical correlations of the Nui and f-factors were developed for the large diameter oval finned-tube heat exchanger as a function of the Reynolds number. As the EG(Ethylene glycol) and air flow rate increases, the heat transfer rate and pressure drop is increased largely.

Characteristics of Near Wake Behind a Circular Cylinder with Serrated fins (IV) - Comparison of Vortex Formation Regions - (톱니형 휜이 부착된 원주의 근접후류특성 연구 (IV) - 와형성영역의 유동비교 -)

  • Ryu, Byong-Nam;Kim, Kyung-Chun;Boo, Jung-Sook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.3
    • /
    • pp.357-366
    • /
    • 2003
  • An experimental study is performed to investigate characteristics of near of wakes of circular cylinders with serrated fins using a hot-wire anemometer for various freestream velocities. The main focus of this paper is to investigate a reason why a vortex formation length is increased suddenly. Velocity of the fluid which flow through fins decreases as fin's height and freestream velocity increases and fin pitch decreases, and a thickness of boundary layer increases. The finned tube has a lower velocity gradient when the higher boundary layer grows. This velocity gradient on finned tube makes a weak shear force in the wake and moves to downstream in a state of lower momentum transfer between the freestream and the wake. The phenomenon makes a vortex formation length increased suddenly. The fluctuations of the velocity distributions on the finned tube and (equation omitted) = 1.0 contour line in the vortex formation region decreases when the fin height increases and the pitch decreases.

Natural Convection Correlation of Circular Finned Tube Heat Exchanger (원형휜-원형관 열교환기에 대한 자연대류 열전달상관식)

  • Kang, Hie-Chan;Jang, Hyun-Soon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.747-752
    • /
    • 2008
  • An experimental study has been conducted on the natural convection heat transfer for the 7 kinds of circular finned tube heat exchangers. Empirical correlation was suggested at the range of 3,500

A Study on Finned Tube Used in Turbo Refrigerator(III) -for Pressure Drop- (터보 냉동기용 핀 튜브에 관한 연구 (III) -압력 손실에 관하여-)

  • Han, Kyu-Il;Kim, Si-Young;Cho, Dong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.6 no.1
    • /
    • pp.58-76
    • /
    • 1994
  • Heat transfer and pressure drop measurements are made on low integral-fin tubes in turbulent water flow condition. The integral-fin tubes investigated in this paper are nominally 19mm in diameter. Eight tubes have been used with trapezoidally shaped integral-fins having fin density from 748 to 1654 fpm and 10, 30 grooves. Plain tube having same diameter as finned tube is also tested for comparison. Experiments are carried out using R-11 as working fluid. The refrigerant condensates at a saturation state of $30^{\circ}C$ on the outside tube surface cooled by coolant. The amount of noncondensable gases present in the test loop is reduced to a negligible value by repeated purging. For a given heat input to the boiler and given cooling water flow rate, all test data are taken on steady state. The heat transfer loop is used for testing single long tubes and cooling water is pumped from a storage tank through filters and flowmeters to the horizontal test section where it is heated by steam condensing on the outside of the tube. The pressure drop across the test section is measured by means of pressure gauge and manometer. Each tube tested is cleaned with sodium dichromate pickling solution and well rinsed with water prior to installation in the test section. The results obtained in this study is as follows : 1. Based on inside diameter and nominal inside area, heat transfer of finned tube is enhanced up to 4 times as that of a plain tube at constant Reynolds number and up to 2 times at constant pumping power. 2. Friction factors are up to 1.6~2.1 times those of plain tube. 3. At a given Reynolds number, Nusselt number decrease with increasing pitch to diameter. 4. The constant pumping power ratio for low integral-fin tubes increase directly with the effective area to the nominal area ratio, and with the effective area diameter ratio.

  • PDF