• Title/Summary/Keyword: finite base

Search Result 682, Processing Time 0.022 seconds

Analysis of Electro-Magnetic Force Acting on Arc Column in Butt-Joint Welding of Mild Steel Plate (연강 판재의 맞대기 용접에서 아크에 작용하는 자기력의 해석)

  • Bae Kang-Yul
    • Journal of Welding and Joining
    • /
    • v.23 no.4
    • /
    • pp.73-80
    • /
    • 2005
  • Arc blow being occurred by Electro-Magnetic force(EMF) during the electric arc welding prevents the formation of a sound weldment. In this study, the effects of arc position, groove size, tack weld and base plate on the EMF in a butt-joint welding of mild steel plate are analyzed by a computer simulation based on the finite element method. The EMF can be numerically identified to be caused by a difference of the magnetic flux-density between ahead of and behind the arc in case that the workpiece locates asymmetrically around the uc. When there exists an air gap of groove ahead of the arc in the welding direction, the similar magnetic force has been producted regardless of the arc position and the gap size. The tack weld alleviates the magnetic force to about one fourth at the finish end of the workpiece. The magnetic force can be also significantly reduced with the base plate to about one fifth at the start end of the workpiece containing a tack weld.

Investigation on Ultimate Strength of STS304L Stainless Steel Welded Connection with Base Metal Fracture Using Finite Element Analysis

  • Lee, HooChang;Kim, TaeSoo;Hwang, BoKyung;Cho, TaeJun
    • International journal of steel structures
    • /
    • v.18 no.4
    • /
    • pp.1139-1152
    • /
    • 2018
  • Many studies on the application of stainless steels as structural materials in buildings and infra-structures have been performed thanks to superior characteristics of corrosion resistance, fire resistance and aesthetic appeal. Experimental investigation to estimate the ultimate strength and fracture mode of the fillet-welded connections of cold-formed austenitic stainless steel (STS304L) with better intergranular corrosion resistance than that of austenitic stainless steel, STS304 commonly used has carried out by authors. Specimens were fabricated to fail by base metal fracture not weld metal fracture with main variables of weld lengths according to loading direction. All specimens showed a block shear fracture mode. In this paper, finite element analysis model was developed to predict the ultimate behaviors of welded connection and its validity was verified through the comparison with test results. Since the block shear behavior of welded connection due to stress triaxiality and shear-lag effects is different from that of bolted connection, stress and strain distributions in the critical path of tensile and shear fracture section were investigated. Test and analysis strengths were compared with those by current design specifications such as AISC, EC3 and existing researcher's proposed equations. In addition, through parametric analysis with extended variables, the conditions of end distance and longitudinal weld length for block shear fracture and tensile fracture were suggested.

Experimental study of a modeled building frame supported by pile groups embedded in cohesionless soil

  • Ravi Kumar Reddy, C.;Gunneswara Rao, T.D.
    • Interaction and multiscale mechanics
    • /
    • v.4 no.4
    • /
    • pp.321-336
    • /
    • 2011
  • This paper presents the results of static vertical load tests carried out on a model building frame supported by pile groups embedded in cohesionless soil (sand). The effect of soil interaction on displacements and rotation at the column base and also the shears and bending moments in the columns of the building frame were investigated. The experimental results have been compared with those obtained from the finite element analysis and conventional method of analysis. Soil nonlinearity in the lateral direction is characterized by the p-y curves and in the axial direction by nonlinear vertical springs along the length of the piles (${\tau}-z$ curves) at their tips (Q-z curves). The results reveal that the conventional method gives the shear force in the column by about 40-60%, the bending moment at the column top about 20-30% and at the column base about 75-100% more than those from the experimental results. The response of the frame from the experimental results is in good agreement with that obtained by the nonlinear finite element analysis.

VP-ellipsis, Stripping, and the Functions of the Delimiter -to in Korean

  • Kim, So-Jee;Cho, Sae-Youn
    • Language and Information
    • /
    • v.20 no.1
    • /
    • pp.93-110
    • /
    • 2016
  • VP-ellipsis constructions in English can be schematized as S + [NP finite-AUX __ ] where the underlined part is understood to be a VP. Similarly, the pattern S + NP[-to] can be observed in Korean colloquial contexts. Though the English VP-ellipsis sentence pattern and the Korean pattern superficially seem to be similar, the Korean pattern exhibits peculiar properties: Syntactically, the NP of the pattern should have the delimiter -to. Semantically, it may convey ambiguous readings: VP-ellipsis-like and/or Stripping-like interpretation. To account for the pattern at issue, we propose a base-generated analysis driven by the delimiter -to within a construction grammar. We claim that the mother of the NP[-to] in this pattern is an S whose meaning is ambiguous between a VP-ellipsis-like and a Stripping-like reading. Consequently, the code of the VP-ellipsis in English is finite auxiliary verbs while that of the pattern S + NP[-to] in Korean is the delimiter -to.

  • PDF

Seismic response of adjacent buildings interconnected by viscous dampers considering soil-structure interaction

  • Yavuz S. Hatipoglu;Oguz A. Duzgun
    • Earthquakes and Structures
    • /
    • v.24 no.3
    • /
    • pp.165-181
    • /
    • 2023
  • The effectiveness of fluid viscous dampers (FVDs) on dynamic response mitigation of coupled two adjacent structures was investigated, considering soil-structure interaction (SSI) effects under earthquake excitation. A numerical procedure was employed to evaluate system response. The finite elements were used for the numerical treatment of the adjacent buildings and soil region. Viscous boundary conditions were used as special non-reflecting boundaries on the edges of finite soil region. According to the results, the FVDs were found to be very effective for dynamic response mitigation of the adjacent buildings, even if considering the soil medium. The results showed that the most affecting parameter on the system response was found to be soil type. It was also concluded that when adjacent structures coupled by FVDs, the maximum values of the roof displacements, the base shear forces, and the base bending moments could decrease up to around 50%. Changing in lateral stiffness of the one building has minor effects on the effectiveness of viscous dampers.

Investigation of the Radiative Heating from Aircraft Plume with Particles (입자에 의한 항공기 플룸의 열복사 가열에 관한 연구)

  • Go, Gun-Yung;Yi, Kyung-Joo;Lee, Sung-Nam;Kim, Won-Cheol;Baek, Seung-Wook;Kim, Man-Young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.9
    • /
    • pp.737-744
    • /
    • 2012
  • The finite volume method for radiation is applied for the analysis of radiative base heating by SE and PE of the aircraft exhaust plume. The exhaust plume is considered as an absorbing, emitting, and scattering medium, while the base plane is assumed to be cold and black. The radiative properties of non-gray gases are obtained through the WSGGM, and the particle is modelled as spheres. The present method is validated by comparing the results with those of the backward Monte-Carlo method and then the radiative base heating characteristics are analyzed by changing such various parameters as particle concentration, temperature, and scattering phase function. The results show that the radiative heat flux coming into the base plane decreases with altitude and distance, but it increases as the particle temperature increases. The forward scattering of particles increases PE while it decreases SE.

Influence of Anisotropic Behavior of Aggregate Base on Flexible Pavement Design Life (기층의 이방성 거동이 아스팔트 도로 설계수명에 미치는 영향)

  • Kim, Sung-Hee
    • International Journal of Highway Engineering
    • /
    • v.11 no.1
    • /
    • pp.187-194
    • /
    • 2009
  • This paper presents the development of transfer function accounting for cross-anisotropic behavior of aggregate base material for the pavement thickness design. The stress distributions predicted by nonlinear cross-anisotropic finite element program were realistic by eliminating excessive tensile stress at the bottom of the base layer and the critical pavement responses predicted by nonlinear cross-anisotropic model are higher than those predicted by linear or nonlinear isotropic models (Kim, 2004, Kim et at., 2005). Since the previously developed transfer functions such as Asphalt Institute and Chevron models, etc. were based on the critical responses obtained from linear isotropic model, those equations are not appropriate for the thickness design nonlinear cross-anisotropic base behavior. Therefore, the development of usable transfer functions for nonlinear cross-anisotropic model is ever more important. When the newly developed transfer functions were compared with AASHTO method for the thickness design, the newly developed transfer functions produce approximately 25mm reduced UAB thickness in AASHTO thickness design and this illustrates that linear isotropic model results in more conservative pavement design.

  • PDF

Analytical Study on Structural Behaviors of Post-Tensioned Column-Base Connections for Steel Modular Structures (철골 모듈러 구조물의 포스트텐션 기둥-바닥 접합부 거동에 대한 해석적 연구)

  • Choi, Kyung-Suk;Shin, Dong-Hyeon;Kim, Hyung-Joon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.6
    • /
    • pp.427-435
    • /
    • 2020
  • Modular structures are relatively lightweight compared to reinforced-concrete or steel structures. However, it is difficult to achieve structural integrity between the columns of unit modules in a modular structure, which causes undesirable effects on the lateral force resistance capacity against wind and earthquake loads. This is more prominent in modular structures whose overall heights are greater. Hence, a post-tensioned modular structural system is proposed herein to improve the lateral force resistance capacity of a typical modular structure. A post-tensioned column-base connection, which is the main component of the proposed modular structural system, is configured with shapes and characteristics that allow inducing self-centering behaviors. Finite element analysis was then performed to investigate the hysteretic behaviors of the post-tensioned column-base connection. The analysis results show that the hysteretic behaviors are significantly affected by the initial tension forces and beam-column connection details at the base.

Finite Element Modal Analysis of a Spinning Flexible Disk-Spindle System Considering the Flexibility of Supporting Structures and an Head-Suspension-Actuator in a HDD (지지구조와 헤드-서스펜션-액츄에이터의 유연성을 고려한 HDD 유연 회전 디스크-스핀들 시스템의 유한 요소 고유 진동 해석)

  • Seo, Chan-Hee;Lee, Ho-Sung;Sang, Gun-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.128-135
    • /
    • 2006
  • This paper presents a finite element method to analyze the free vibration of a flexible HDD composed of the spinning disk-spindle system with fluid dynamic bearings(FDBs), the head-suspension-actuator with pivot bearings, and the base plate with complicated geometry. Experimental modal testing shows that the proposed method well predicts tue vibration characteristics of a HDD. This research also shows that even the vibration motion of the spinning disk corresponding to half-speed whirl and the pure disk mode are transferred to a head-suspension-actuator and base plate through the air bearing and the pivot bearing consecutively. The proposed method can be effectively extended to investigate the forced vibration of a HDD and to design a robust HDD against shock.

  • PDF

Influence of wall flexibility on dynamic response of cantilever retaining walls

  • Cakir, Tufan
    • Structural Engineering and Mechanics
    • /
    • v.49 no.1
    • /
    • pp.1-22
    • /
    • 2014
  • A seismic evaluation is made of the response to horizontal ground shaking of cantilever retaining walls using the finite element model in three dimensional space whose verification is provided analytically through the modal analysis technique in case of the assumptions of fixed base, complete bonding behavior at the wall-soil interface, and elastic behavior of soil. Thanks to the versatility of the finite element model, the retained medium is then idealized as a uniform, elastoplastic stratum of constant thickness and semi-infinite extent in the horizontal direction considering debonding behavior at the interface in order to perform comprehensive soil-structure interaction (SSI) analyses. The parameters varied include the flexibility of the wall, the properties of the soil medium, and the characteristics of the ground motion. Two different finite element models corresponding with flexible and rigid wall configurations are studied for six different soil types under the effects of two different ground motions. The response quantities examined incorporate the lateral displacements of the wall relative to the moving base and the stresses in the wall in all directions. The results show that the wall flexibility and soil properties have a major effect on seismic behavior of cantilever retaining walls and should be considered in design criteria of cantilever walls. Furthermore, the results of the numerical investigations are expected to be useful for the better understanding and the optimization of seismic design of this particular type of retaining structure.