• 제목/요약/키워드: finishing position

검색결과 59건 처리시간 0.02초

국립대학교 교사 입면의 디자인 적용현황 연구 - 대구지역의 K대학을 중심으로 - (A Study on the Application of Design in the Facade of the National University - Focused on the k-National University in Deagu -)

  • 서희숙
    • 한국실내디자인학회논문집
    • /
    • 제20권3호
    • /
    • pp.22-32
    • /
    • 2011
  • The purpose of this study is on the application of the facade design of k-national university in deagu. The subjects of the study examined 75 buildings from the 117 university buildings in main campus. The analysis items is analyzed by several elements; flat and sloping roof, main entrance, design principle, style of architecture, finishing materials, and characteristics of design surveyed by analysis items. The results are as follows: In the 1950s, 2 subjects have shown conflicting characteristics except brick finishing materials. In he 1960s, flat make up 75% of a whole, centrality in main entrances occur, but have an asymmetrical, during this period vertical motif have been underlined by repetition of column, stone has application to main adminstration building. The buildings in the 1970s were so characteristics of modern architecture by painting and flat except main entrance at the center of facade. In the 1980s, position of main entrance have a corner of a wall, finishing materials of a wall were beginning to use stone, glass and metal. The buildings in the 1990s and 2000s are looking a three-dimensional composition by rhythm of superimposition and segmentation and all finishing materials of analysis items are in use.

열연 루퍼시스템의 퍼지 장력제어 (A Fuzzy Tension Control Method for the Coupled Looper System at the Hot Rolling Process)

  • 허윤기
    • 제어로봇시스템학회논문지
    • /
    • 제16권10호
    • /
    • pp.1006-1012
    • /
    • 2010
  • The hot rolling process ranks the highest position for production in steel making process. The hot strip manufacturing processes consist of the reheating furnace, roughing and finishing mill and coiler. The reheating furnace heats the slab. The roughing and finishing mill produce the hot strip from slab. The hot strip quality mainly depends on finishing mill, which consists of 4-high 7 stands. The looper is installed between stands and is used for controlling the strip tension by the looper angle for better material flow. It is difficult to control the strip tension with the coupled looper system from interaction between the looper angle and strip tension. Too much deviation of strip tension severely affects the poor width quality of the hot strip. It is important to control simultaneously both the looper angle and strip tension with each of their target values. This paper proposes the fuzzy tension control, which is developed to minimize the width deviation of the hot strip by maintaining the proper strip tension between stands and to achieve the stable operation of the coupled looper system. The fuzzy tension control performance is compared with the conventional PID control by experimental results.

공동주택의 실내부 표면적 및 사용 마감재 구성 실태분석 (Real Survey on Interior Surface Area and Applied Finishes in Recently-Planned Apartment Houses)

  • 이지순
    • KIEAE Journal
    • /
    • 제10권6호
    • /
    • pp.115-121
    • /
    • 2010
  • This paper is an outgrowth of many years of practicing real interior work projects and one of my responses to the question not only about the actual dimension of interior work surface but also about the classification of contemporary finishing materials in basic interior project of high-rise apartment houses. For this purpose, 8 conventional apartment units which are already-built or designed have been surveyed and the results are interpreted in the form of proportion of space and finishes. The data can be applied to make up a schematic design in the selection of environment-friendly interior works and assessment of the degree of sustainability. For further study, the basic data provided here can be used as an index to differentiate the occupants' desire toward green interior design for their own apartment spaces, comparing to the conventional interior work in the Korean market. Not surprisingly, wall paper is dominated to make the interior surface in apartment houses. In the percentile of the utilization of finishing materials, wood-flooring and coating materials like wet paint also ranked at the upper position.

벤조페논 유도체의 자외선 차단 효과 및 염색물의 일광견뢰도에 미치는 영향 (The Effect of Benzophenone Derivatives on the Shielding of Ultraviolet Rays and Light-fastness of the Dyed Fabrics)

  • 김종규;김태경;박태수;임용진
    • 한국염색가공학회지
    • /
    • 제10권4호
    • /
    • pp.53-61
    • /
    • 1998
  • The absorptions of ultraviolet rays of benzophenone derivatives were investigated in terms of the position of substituent, especially hydroxyl group. When the derivatives were added to the aqueous solution of Rhodamin B, which has very low light-fastness, all of them delayed the photofading of Rhodamin B solution. But on the fabrics, only the derivatives with the hydroxyl group at 2-position showed the good ability of ultraviolet rays absorption. The benzophenone derivatives absorb ultraviolet rays to form a hydrogen bond between hydroxyl group and carbonyl group, and return to their original structure by releasing heat energy. In solution, the derivatives can form a intermolecular hydrogen bond, and absorb the ultraviolet rays. But on the fabric, the intermolecular hydrogen bond is impossible, only hydroxyl group of 2-position forms a intramolecular hydrogen bond, and that makes the derivatives on the fabric absorb ultraviolet rays.

  • PDF

직기 특성이 PET직물 물성에 미치는 영향(I) (Effects of Weaving Machine Characteristics on the Physical Properties of PET Fabrics (I))

  • 김승진;손준혁;강지만;박명환
    • 한국염색가공학회지
    • /
    • 제16권4호
    • /
    • pp.26-35
    • /
    • 2004
  • This study surveys the tension differences between Korean domestic and foreign looms and analyses fabric mechanical properties due to warp and weft tension differences using KES-FB system. Paper is divided by two parts. In this 1st paper, fabric is designed as 5 harness satin weave using 75d/36f warp and 100d/192f weft polyester filaments, and is woven by $Omega^\circledR$ rapier loom by Textec Co.Ltd and Picanol$-GTX^\circledR$ rapier loom by Picanol Co.Ltd respectively. These grey fabrics are processed on the same dyeing and finishing processes. Weavability is also analysed by measuring warp tension variation according to the warp position, the relationship between shed amount and the warp tension on one fixed heald frame is surveyed, and the relationship between end breaks and warp and weft tensions is also discussed.

글루타르알데히드 가교에 의한 혼성배열 폴리비닐알코올 수화겔의 제조 (Preparation of Atactic Poly(vinyl alcohol) Hydrogel by Glutaraldehyde Crosslinking)

  • Won Seok Lyoo;In Seok Seo;Byung Chul Ji
    • 한국섬유공학회:학술대회논문집
    • /
    • 한국섬유공학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.324-325
    • /
    • 2001
  • Poly(vinyl alcohol) (PVA) is useful for biomaterials such as contact lens, drug delivery system, and biological tissues, because of good biocompatibility and no toxicity. Particularly, hydrogels have unique position in biomaterial fields because of their high water contents.[1-2] Because atactic PVA (a-PVA) is very weak in water, a-PVA need to be chemically crosslinked with crosslinking agent such as glutaradehyde to prepare PVA hydrogels with high water-resistance and good physical properties.[3] (omitted)

  • PDF

직기 특성이 PET직물 물성에 미치는 영향(III) (Effects of Weaving Machine Characteristics on the Physical Properties of PET Fabrics (III))

  • 김승진;진영대;강지만;정기진
    • 한국염색가공학회지
    • /
    • 제16권5호
    • /
    • pp.48-53
    • /
    • 2004
  • This study surveys the tension differences between Textec and Vamatex looms and analyses fabric mechanical properties using KES-FB system according to warp and weft tension differences. Fabric is designed as 5 harness satin weave using 150d/48f warp and 200d/384f weft polyester filaments, and is woven by $Omega^{\circledR$-Panter rapier loom by Textec Co.Ltd and P1001es rapier loom by Vamatex Co.Ltd., respectively. These grey fabrics are processed on the same dyeing and finishing processes. Weavability is also analysed by measuring warp tension variation according to the warp position. The relationship between shed amount and the warp tension on one fixed heald frame is surveyed, and the relationship between end breaks and warp and weft tensions is also discussed.

Coping design에 따른 도재전장관의 파절강도에 관한 연구 (THE FRACTURE RESISTANCE OF CERAMOMETAL CROWN WITH VARIOUS COPING DESIGN)

  • 정완모;동진근;진태호
    • 대한치과보철학회지
    • /
    • 제30권1호
    • /
    • pp.125-132
    • /
    • 1992
  • The purpose of this study was to evaluate the effect of the metal coping design on the fracture resistance of ceramometal crown. The Ni-Cr alloy(Supranium, Krupp Co., German) and Vaccm-fired porcelain powder(Vita VMK 689, Vita Co., Germany) were used in this study. The measurement of fracture resisitance of ceramometal crown was done with Instron Universial Testing Machine(Instro Co., Model no.4201). The obained results were as fellows : 1. The fracture resistance measured at the buccal cusp tip was the highest value in the group that those position of ceramometal junction was 2mm superior to the lingual finshing margin(100.25Kg) and the fracture resistance revealed on order of the group that those position was 2mm buccal to the central groove(51.64Kg). 2. The fracture resistance measured at the central groove was higher value in the group that those position was 2mm lingual to the central groove than in the group that those position was 2mm lingual to the central groove than in the group that those position was 2mm superior to lingual finishing margin(132.48Kg). 3. In all cases, the fracture resistance at the central groove was higher than that at the buccal cusp tip.

  • PDF

다중이용업소 실내마감재료 사용기준에 관한 연구 (A Study on Using the Interior Finishing Material using Regulation at Multiple-using Businesses)

  • 김용성;조성오
    • 한국실내디자인학회논문집
    • /
    • 제22권5호
    • /
    • pp.216-224
    • /
    • 2013
  • There are the relevant provisions that apply to building regulations about the Building codes, Fire Protection laws, and more Multi-using interior finish materials businesses etc. The differences between these regulations are as follows: The Building codes is defined the main use of the building according to facilities to used to set the scale by the use of the floor space, On the other hand, Fire Protection laws are the basic purpose and the act of using the architectural space(or sales) by separating object by fire. And Multiple-using Businesses Facilities consist of two regulations engaged in the kind of law and the size of the floor area. One building can not be based on operating facilities and together in Multiple use businesses Law. As such, the Buildings are applied to the Building codes, Fire Protection laws, such as Multi-using Businesses Facilities interior construction industry due to the structural differences in the position of the designer feeling a lot of difficulties and confusion. The Multi-use businesses Facilities engage in the kind of law, the size of the floor area and seating capacity. These can not be based on operating facilities, and consists of two regulations together in one building. This study is purposed to help improving the finish of the interior architecture that is related to the Building code regulations, Fire Protection laws, Multi-using Facilities interior finishing material relevant with the provisions from the law through analyze the case of developed countries, and the current Multiple use Businesses Facilities research range from the law of multiple-using facilities, interior finishing, interior architecture for supervision reasonably and compensation for the interior design. So, Result is as follows: First, interior decorations can be separated the fixed material and the moveable things. second, It should be included multi-using Business though small size business space at the basement floor. third, It should be established statute law that design and construction responsibility. forth, re-testing fire resist performance after some period. and finally, it need to mitigate regulation where be installed sprinkler.

금속 소부 도재관의 경우 인접면에서 접촉점의 위치가 도재 파절에 미치는 영향에 관한 연구 (A Study on effect that position of contact area at adjacent side has on fractures of porcelains in case of porcelain fused to metal crown)

  • 김용원
    • 대한치과기공학회지
    • /
    • 제29권2호
    • /
    • pp.173-180
    • /
    • 2007
  • There was a great problem about the deposition between materials of a different kind at the beginnings of the introduction of porcelains, however, thereafter the deposition efficiency was settlded to the sufficient level of all user thanks to effort to have studied by many scholars and clinical authorities. But in a clinical process, as the difference of designs has an effect on fractures of porcelains, this researcher divided them into 4 groups of A: 1 mm, B: 2 mm, C: 3 mm, and D: 4 mm, and made 40 pieces to each 10 as the test samples to consider a length axis of tooth for studies in accordance with a position of a finishing line to meet between porcelain and metal at the contact point at the adjacent side to a metal porcelain. The sample materials are those to be use at the open market and the test samples wer completed by the same manufacturing technique to that of existent metal porcelain tube. s a result of the strength test on fractures, the average value is as in the following, A: 1 mm - 8.5bar, B: 2 mm - 10.5bar, C: 3 mm - 14.3bar, and D: 4 mm - 15.0bar. In case of the metal porcelain tube, the more faraway to process parts of metal and porcelain from the contact point of adjacent side has the stronger strength of fractures, Accordingly, the research shows that it had better to keep off more than 3 to consider a ledngth axis of tooth.

  • PDF