• 제목/요약/키워드: fin efficiency

검색결과 173건 처리시간 0.022초

Forced Convection Heat Transfer in a Plate Fin With Transient Heat Conduction (과도열전도를 갖는 평판핀에서의 강제대류 열전달)

  • 조진호;이상균
    • Journal of the korean Society of Automotive Engineers
    • /
    • 제9권4호
    • /
    • pp.69-76
    • /
    • 1987
  • A conjugate conduction-convection analysis has been made for a plate fin which exchanges heat with its fluid environment by forced convection. The analysis is based on a one- dimensional model for the plate fin whereby the transient heat conduction equation for the fin is solved simultaneously with the conservation equations for mass, momentum, and energy in the fluid boundary layer adjacent to the fin. The forced convection heat transfer coefficient is not specified in advance but is one the results of the numerical solutions. Numerical results of the overall heat transfer rate, the local heat transfer coefficient, the local heat flux, the fin efficiency and the fin surface temperature distribution for Pr=0.7 are presented for a wide range of operating conditions.

  • PDF

An Experimental Study on the Airside Performance of Fin-and-Tube Heat Exchangers Having Wide Louver Fin (광폭 루버 핀이 장착된 핀-관 열교환기의 공기측 전열 성능에 관한 실험적 연구)

  • Kim, Nae-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제27권5호
    • /
    • pp.254-262
    • /
    • 2015
  • Heat transfer rate can be increased by increasing the heat transfer area. In this study, wide louver fin-and-tube heat exchangers with $P_t/P_l=1.03$ were tested and compared with louver fin-and-tube heat exchanger with $P_t/P_l=0.6$. Results show that heat transfer capacities of wide louver samples are larger (9.8% at one row, 13.6% at two row and 4.1% at three row) than those of conventional louver samples. Considering the area ratio of 1.78, the increase of heat transfer capacity is rather small, possibly due to the smaller heat transfer coefficient and fin efficiency of the wide louver sample. The j factor of the louver fin was 67% larger at one row, 42% larger at two row and 52% larger at three row. The f factor of the louver fin was 81% larger at one row, 63% larger at two row and 60% larger at three row. The effect of fin pitch on j and f factors are not pronounced and the j factor decreased as the number of tube row increased.

An experimental study of behavior of defrosting on the fin-tube heat exchanger (핀-관 열교환기에 대한 제상 거동에 관한 실험적 연구)

  • Lee, Kwan-Soo;Kim, Kyu-Woo;Ji, Sung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제10권6호
    • /
    • pp.649-657
    • /
    • 1998
  • In this study, the effects of the various conditions of frosting and defrosting on the behavior of defrosting in a fin-tube heat exchanger have been examined experimentally. The electric heater is used for defrosting in a fin-tube heat exchanger It is shown that there are several local maxima in the water draining rate. The amount of residual water on the heat exchanger after the completion of defrosting is kept constant due to surface tension on the heat exchanger. Without considering the degradation of the thermal performance due to the frosting, the defrosting efficiency is improved with increasing amount of the frost irrespective of the frosting condition. The defrosting behavior is affected by the frosting density as well as the frost accumulation, which vary with the experimental operating conditions during the frosting period. The heat loss to the surrounding air decreases, and the melting and defrosting efficiencies show high values with decreasing heat input.

  • PDF

Data Reduction on the Air-side Heat Transfer Coefficients of Heat Exchangers under Dehumidifying Conditions (제습이 수반된 공조용 증발기 습표면의 열전달계수 데이터 리덕션)

  • Kim, Nae-Hyun;Oh, Wang-Kyu;Cho, Jin-Pyo;Park, Hwan-Young;Yoon, Baek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제15권1호
    • /
    • pp.73-85
    • /
    • 2003
  • Four different methods of reducing the heat transfer coefficients from experimental data under dehumidifying conditions are compared. The four methods consist of two different heat and mass transfer models and two different fin efficiency models. Data are obtained from two heat exchanger samples having plain fins or wave fins. Comparison of the data with the reduction methods revealed that the single potential heat and mass transfer model yielded the humidity independent heat transfer coefficients. Two different fin efficiency models - enthalpy model and humidity model - yielded approximately the same fin efficiencies and accordingly approximately the same heat transfer coefficients. The heat transfer coefficients under wet conditions were approximately the same as those of the dry conditions for the plain fin configuration. For the wave fin configuration, however, wet surface heat transfer coefficients were approximately 12% higher. The pressure drops of the wet surface were 10% to 45% larger than those of the dry surface.

Analysis of the Transient Response in Annular Fin with Rectangular Profile (구형단면을 갖는 환상휜에서의 과도응답 해석)

  • Kim Kwang Soo;Yong Ho Taek
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • 제16권5호
    • /
    • pp.504-515
    • /
    • 1987
  • This study conducts an analysis for the heat diffusion of an annular fin considering con-vection phenomena at the fin edge as well as along the fin perimeter. When the temperature of the fin base is given with an increasing exponential function, the exact series solutions of tem-perature distribution are obtained by laplace transformation in terms of dimensionless para-meters. From these solutions heat flux and fin efficiency can be obtained. These exact solu-tions converge rapidly for large values of dimensionless time, but slowly for small ones. To avoid this convergence difficulty, approximate solutions of the temperature distribution and heat flux for small values of dimensionless time are also presented. Substituting the variations of dimensionless parameters into the these exact solutions, the characteristics of these response are investigated.

  • PDF

Heat transfer characteristics of an internal cooling channel with pin-fins and ribbed endwalls in gas turbine blade

  • Vu T.A. Co;Hung C. Hoang;Duy C.K. Do;Son H. Truong;Diem G. Pham;Nhung T.T. Le;Truong C. Dinh;Linh T. Nha
    • Advances in aircraft and spacecraft science
    • /
    • 제11권2호
    • /
    • pp.153-175
    • /
    • 2024
  • In jet engines, turbine blade cooling has an extremely important role. The pin-fin array, which is situated close to the trailing edge of the blade, aids in internal cooling of the gas turbine blades and preserves the structural integrity of the blade. Previous studies often focused on pin-fin configurations, but the current research focuses on improving the geometry at the endwalls to reduce wake vortices behind the pin-fins and enhance heat transfer at the endwalls location. Using the k-ω turbulence model, a numerical study was conducted on a ribbed shape situated on the walls between pin-fin arrays, spanning a Reynolds number range of 7400 to 36000, in order to determine the heat transport characteristics. The heat transfer efficiency coefficient and Nusselt number increase dramatically with the revised wall configuration, according to the numerical data. The channel's heat transfer efficiency is increased by enlarging the heat transfer areas near the pin-fins and by the interaction of the flow with the endwalls. The addition of ribs causes the Nusselt number of the new model to climb from 78% to 96% at the previously given Reynolds numbers, and the heat transfer efficiency index to rise from 60% to 73%. The height (Hr), position (Lr), forward width (Wf), and backward width (Wb) of the ribs are among the geometric elements that were looked at in order to determine how they affected the performance of heat transmission. In comparison to the reference design, the parametric study results demonstrate that the best forward width (Wf/R=18.75%) and backward width (Wb/R=31.25%) increase the heat transfer efficiency index by 0.4% and 1.3%, respectively.

A Study on Beat Transfer Characteristics in the Air Side of Large-scaled Heat Exchanger (확대모형 열교환기를 이용한 공기측 열전달 성능에 관한 연구)

  • Byun Ju-Suk;Lee Jinho;Hong Man-Gi;Jeon Chang-Duk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제29권9호
    • /
    • pp.1032-1041
    • /
    • 2005
  • This study is performed to investigate the heat transfer characteristics of heat exchanger according to the arrangement of fins as well as fin configuration by using the four times enlarged model. Friction factor, Colburn j factor and goodness factors are compared to each other to estimate performance of each case for 4 different kinds of fins, which are plain, single side slit, double side slit and louver fin. Results show that heat transfer would be altered by fin arrangement and that friction loss is more affected by fin configurations than by the fin arrangements. In particular, heat transfer depends more on the shape of front row than that of rear row. The heat transfer rate of combined fin arrangement increases a lot more under the same pressure drop than that of conventional fin arrangement. This indicates that the heat exchanger of higher efficiency would be designed by the proper combination of fins, of different shapes.

Optimal Design of a Plate-Fin Heat Sink with Slip Flow (경계면 슬립이 적용되는 Plate-Fin Heat Sink 의 최적형상 설계)

  • Park, Boo Seong;Park, Hyun Jin;Kim, Bo Hung
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제32권2호
    • /
    • pp.219-227
    • /
    • 2015
  • A dehumidifier using a thermoelement has many advantages compare to a dehumidifier using compressor systems. However, it is crucial to optimize the performance of heat sink for improving heat dissipation problem on the heat generation part. In this study, we utilized computational fluid dynamics software to compare Nusselt number, temperature and system efficiency based on fin thickness, flow gap between fin and fin length. Moreover, slip flow on the boundary layer was applied for the further analysis. Our objective in this study is to suggest an optimal fin shape to improve heat transfer with the tendency of performance factor depending on change of the shapes. Our results on the optimization of fin shape and analysis of slip flow will be utilized to enhance the heat transfer in the heat sink which is important in the design of dehumidifier using a thermoelement.

Numerical Analysis of the Heat and Mass Transfer in a Fin Tube Type Adsorber (핀튜브형 흡착탑에서 열 및 물질전달 수치해석)

  • Kwon, Oh Kyung;Chung, Jae Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제25권8호
    • /
    • pp.457-463
    • /
    • 2013
  • Nowadays, adsorption chillers have been receiving considerable attention, as they are energy saving and environmentally benign systems. A fin tube type heat exchanger in which adsorption/desorption takes place is required with more compact size. The adsorption chiller is expected to have high energy efficiency in utilizing the waste heat exhausted from a process. The objectives of this paper are to scrutinize the effect of design parameters on the adsorption performance, especially the fin pitch of the fin tube, and to develop an optimal design fin tube heat exchanger in a silica gel/water adsorption chiller. From the numerical results, the fin pitch of 2.5 mm shows the highest adsorption rate, compared to other fin pitches, such as 5 mm, 7.5 mm and 10mm. Also, the adsorption rate is affected by the cooling water and hot water temperature.