• Title/Summary/Keyword: filtration time

Search Result 543, Processing Time 0.031 seconds

Comparison of Efficiency between Pre-storage and Post-storage filtration by Leukoreduction Blood Filter

  • Shin, Geon Sik;Kim, Bohee;Kim, Sung Hoon;Rhee, Ki-Jong;Kim, Yoon Suk
    • Biomedical Science Letters
    • /
    • v.23 no.2
    • /
    • pp.111-117
    • /
    • 2017
  • Leukocytes in blood components are involved in diverse adverse transfusion reactions such as febrile non-hemolytic transfusion reactions. Therefore, leukocyte reduction is required to reduce these adverse reactions. The objective of this study was to compare the efficiency of pre-storage filtration and post-storage filtration. Filtration time, residual leukocyte count, RBC recovery, and hemolysis were assessed after pre-storage or post-storage filtration. Compared to pre-storage filtration, filtration time was prolonged and hemolysis was dramatically increased when post-storage filtration was performed. Residual leukocytes count and RBC recovery after post-storage filtration were similar with those obtained after pre-storage filtration. These results suggest that pre-storage filtration has better efficiency than post-storage filtration. These are thought to contribute to the production of better quality of leukoreduction blood components.

Characteristics of High-Rate Filtration with Filtration Aids (급속여과공정에서의 여과보조제 사용에 따른 여과특성)

  • Ahn, Jong-Ho;Yoon, Jae-Heung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.3
    • /
    • pp.260-270
    • /
    • 2000
  • The objective of this study is to evaluate the effect of filter aids in the dual-media rapid filtration. Paper-filter tests were conducted to determine the proper dosages of coagulant and filter aid, and pilot plant tests using two dual-media filter columns were performed for a variety of filtration rates. Using a filter aid (non-ionic polymer), the maximum feasible filtration rate is 480m/day, while turbidity is less than 0.3 NTU and filter run-time is about 70 hours. It is possible to increase the filtration rate up to 360 m/day for keeping the turbidity less than 0.1 NTU. Turbidity increases for the filtration rate greater than 360m/day. In general, the quality of filtered water with a filter aid is stable, while the filter maintains a sufficient filter run-time for a maximum allowable head loss. Particularly, the initial breakthrough can be effectively controlled. The use of a filter aid may be one of the methods applicable if the turbidity of filtered water is required to be improved or if the filter breakthrough limits filter run-time.

  • PDF

Filtration Efficiency of Electrically Charged Air Filters by a Corona Method

  • Murtadlo, Zainul Alim Ali;Joe, Yun-Haeng;Park, Seok-Hoon;Park, Hyun-Seol
    • Particle and aerosol research
    • /
    • v.15 no.1
    • /
    • pp.15-25
    • /
    • 2019
  • The influences of corona charging parameters on collection efficiency and surface potential of air filters were investigated. A polypropylene filter medium was electrically charged using a corona charger, and the resulting surface potential and filtration efficiency against neutralized KCl particles were measured. The filter media was charged under different conditions of applied voltage, voltage polarity, charging time, and distance between electrodes. In addition, we considered charging both sides of the filter as well as charging one side of the filter. As a result, electrical force obtained by charged fiber affected filtration efficiency when the apply voltage strength was higher than 7 kV. Negatively charged filter had higher filtration efficiency than positively charged filter while the surface potential of the negatively charged filter was slightly lower than those of positively charged filter. Moreover, the filtration efficiency increased as the charging time of filter fiber increased and the distance between electrodes decreased. The filtration efficiency was more sensitive to changes of charging time than to those of electrode distance, and the efficiency of both sides charged filter was higher than that of single side charged filter.

Determination of the optimum filtration conditions in pretreatment of seawater desalination by reverse osmosis (역삼투법 해수담수화 전처리 여과공정의 최적조건)

  • Kim, Seung-Hyun;Yoon, Jong-Sup;Lee, Seockheon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.2
    • /
    • pp.207-214
    • /
    • 2009
  • This study examines the optimum filtration conditions in pretreatment of seawater desalination by reverse osmosis. For this purpose, Masan bay seawater is treated through a gravity filter column while $FeCl_3$ is added as coagulant. The conditions of coagulantd osage, media depth, filtration rate, and backwash time are evaluated. The study results show that the filtrate quality improved with increasing coagulant dosage, but head loss rapidly increased. After 4mg/L, the unit filter run volume reduced to less than $200m^3/m^2$. Considering the head loss development, 4mg/L is determined as the optimum dosage. The better filtrate qualities are obtained with depth of 100cm than that of 80cm. The two stage filtration, which outperformed the single stage filtration, is suggested for treatment of Masan bay. The filtration rate of 5m/h is decided as the optimum condition considering the head loss development. At 10m/h, the filtrate quality deteriorated even though the extent was minimal, and head loss increased rapidly. The backwash time of 10 min is decided appropriate.

Evaluation of Extended Canine Semen by Glass Wool filtration (Glass Wool Filtration을 이용한 개 희석정액의 운동성과 생존률의 검정)

  • Yoon Jae-Won;Lee Young-Jun;Kim Sue-Hee;Ji Dong-Beom;Kim Yong-Jun
    • Journal of Veterinary Clinics
    • /
    • v.22 no.3
    • /
    • pp.228-232
    • /
    • 2005
  • Damaged spermatozoa are supposed to be trapped in glass wool. In the respect of this, two glass wool filtration spermatozoa groups (0.5 cm, 1 cm depth) were compared with control group to assay sperm motility, HOS values, and vital rate by CFDA/PI staining method following glass wool filtration. The motility of canine sperm extended with PBS+PVP after glass wool filtration was lower in both filtrated groups than that of the control group (p<0.01) and the same significant difference was also shown in canine semen extended with Tris buffer (p<0.01). The motility of canine sperm diluted with PBS+PVP was higher than that diluted with Tris buffer in the same experimental groups (p<0.05). The motility of control group was not significantly decreased until 2 hours immediately after extending, however, the motility of both glass wool filtrated spermatozoa were significantly decreased as time passed until 2 hours after filtration (p<0.01). At each time for assay (immediately, 30 min, 2 hours after filtration), the motility of canine sperm of control group was higher than the filtrated groups (p<0.05), whereas the motility of 0.5 cm depth group was higher than 1 cm depth group at the immediate time after filtration (p<0.05), 30 minutes later (p<0.05) with no difference at 2 hours. No difference was shown among the experimental groups in HOS values of canine sperm after glass wool filtration. The vital rate assayed by CFDA/PI staining of both filter groups was higher than the control group (p<0.05).

Analysis the Correlation of Filtration Rate of Herbal-acupunctures and Pain Score of Herbal Acupuncture Stimulation (약침제재별 여과속도와 약침 시술시 느끼는 통증의 상관성 분석)

  • Baek, Seung-Tae;Byun, Hyuk;Park, Min-Je;Lee, Seung-Deok;Kim, Kap-Sung
    • Journal of Acupuncture Research
    • /
    • v.23 no.6
    • /
    • pp.85-101
    • /
    • 2006
  • Objectives : This study was designed to find out correlation of filtration rate of herbal-acupunctures and pain score of herbal acupuncture stimulation. Methods : Filtration rate of Hwangryunhaedoktang herbal acupuncture, Kidney yang deficiency number two herbal acupuncture, Hominis Placenta herbal acupuncture, Cervus Elaphus herbal acupuncture, BUM herbal acupuncture and Carthami Flos herbal acupuncture were measured at the korean institute of herbal acupuncture. And Hwangryunhaedoktang herbal acupuncture, Kidney yang deficiency number two herbal acupuncture, Hominis Placenta herbal acupuncture, Cervus Elaphus herbal acupuncture, BUM herbal acupuncture and Carthami Flos herbal acupuncture were injected at Xie points of the subjects. Results : Ranking of herbal acupunctures filtration rates is the same as ranking of pain score and duration time of herbal acupuncture. Correlation analysis result of herbal acupunctures filtration rates and herbal acupuncture VAS with a simple linear regression analysis is that correlation coefficient of Hwangryunhaedoktang herbal acupuncture, Kidney Yang Deficiency Number Two herbal acupuncture, Hominis Placenta herbal acupuncture, Cervus elaphus herbal acupuncture, BUM herbal acupuncture. Carthami Flos herbal acupuncture is 0.44, 0.53, 0.58, 0.76, 0.47 and 0.54. Correlation analysis result of herbal acupuncture's filtration rates and herbal acupuncture stimulation's duration time is that correlation coefficient of Hwangryunhaedoktang herbal acupuncture, Kidney Yang Deficiency Number Two herbal acupuncture, Hominis Placenta herbal acupuncture, Cervus Elaphus herbal acupuncture, BUM herbal acupuncture, Carthami Flos herbal acupuncture is -0.09, 0.11, -0.07, 0.28, -0.11 and -0.09. Conclusion : We found the correlation of filtration rate of herbal-acupunctures and pain score of herbal-acupuncture stimulation. This study help to control pain amount and pain duration time of herbal acupuncture treatment. And this study improve acupuncture theory of herbal acupuncture.

  • PDF

The Optimal Composing the Filter-Bed for Coping with Daily Flow-Rate Fluctuation for the Performance of Sand Filtration Process (일유량 변동에 따른 여과수질 악화에 대처하기 위한 최적 여재구성에 관한 연구)

  • Park, Dong-Hak;Park, No-Suk;Kim, Seong-Su;Bae, Cheol-Ho;Jung, Nahm-Chung;Cjoi, Seung-II
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.485-491
    • /
    • 2007
  • The fluctuation of inlet flow to a water treatment plant makes a serious problem that it can change the filtration rate abruptly, and ultimately occur the breakthrough of the detained particles inside filter media. Also, since it takes very short time (about 10 minutes) for the surface wave occurred from the fluctuation of inlet flow to reach the filtration process, it is impossible to control the filtration rate stably. Therefore, this study was conducted to evaluate the effect of daily flow-rate fluctuation on the performance of sand filtration process, and to suggest the dual media composition for coping with that effect. Comparative column tests have been carried out for various dual media (sand and anthracite) compositions. From the results of column tests, dual media, especially in the case of sand 45cm/anthracite 30cm, is more effective to cope with the effect of flow-rate fluctuation on the performance of filtration than single media (only sand). In addition, irrespective of dual media composition, managing ability to cope with that fluctuation tends to be weak at the end of allowable filtration duration time,

Treatment Characteristics of Rapid filtration Process treating Secondary Clarifier Effluent for Wastewater Reuse (처리수 재이용을 위한 최종침전지 유출수의 급속여과공정 처리특성)

  • Han, Dong-U
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.2
    • /
    • pp.213-220
    • /
    • 2002
  • This reserch was focused upon experimental study for wastewater reuse and conducted to evaluate optimum operating conditions of rapid filtration process such as filter flow rate, filtration time and backwashing condition for reuse of secondary-treated effluent using the pilot plant installed in real wastewater treatment plant. Also, the experiment on treatment char-acteristics of coagulant-added activated sludge process was performed to compare with activated sludge succeeded to rapid filtration. As the filtration velocity was 100m/day, the filtration time of the rapid filter connected with activated sludge system was revealed to 40 hours. Backwashing of filter was conducted by water wash and air scour. The optimum backwashing time and backwash flow rate were 10min and 10LPM, respectively. The quantity of backwashing water of the rapid filter was about 2% of total treated water.

Particle Detachment in Granular Media Filtration (입상여과에서 입자물질의 탈리)

  • Kim, Jinkeun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.673-679
    • /
    • 2004
  • Particle breakthrough can occur by either the breakoff of previously captured particles (or flocs) or the direct passage of some influent particles through the filter. Filtration experiments were performed in a laboratory-scale filter using spherical glass beads with a diameter of 0.55 mm as collectors. A single type of particle suspension (Min-U-Sil 5, nearly pure $SiO_2$) and three different destabilization methods (pH control, alum and polymer destabilization) were utilized. The operating conditions were similar to those of standard media filtration practice: a filtration velocity of 5 m/h. To assess the possibility of particle detachment during the normal filtration, a hydraulic shock load (20% increase of flow rate) was applied after 4 hours of normal filtration. The magnitude of particle detachment was proportional to the particle size for non-Brownian particles. At the same time, less favorable particles, i.e., particles with larger surface charge, were easily detached during the hydraulic shock load. Therefore, proper particle destabilization before filtration is crucial for maximum particle removal as well as minimum particle breakthrough.

Evaluation of a Rapid Sand Filter with Surface Wash and Backwash Conditions (정수장 급속여과지 역세척 수위변화와 시간에 따른 세척 효율 평가)

  • Jung, Yong-Jun;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.652-656
    • /
    • 2004
  • Both surface wash and backwash are considered as one of the most important methods that can improve the filtration efficiency in the existing water treatment plant. This study has mainly focused on the improvement of filtering efficiency by controlling surface wash and backwash time, and water level before backwash (when drained up to the trough, when drained up to 10 cm above filter bed, and when drained below 10 cm filter bed). Filtration efficiency was shown a little bit of differences depending on the operating conditions like surface wash injection pressure, the distance control between filter bed and the facility, and the types of surface wash. When the water level before backwash was reached up to 10 cm below filter bed after draining, however, the filtration velocity and the turbidity removal efficiency in the filter bed was improved. When the surface wash followed by backwash is longer, it showed a similar result. Because the proper adjustment of surface washing time makes filtration efficiency higher, therefore, it is necessary to set up the backwash time moderately.