• Title/Summary/Keyword: filters

Search Result 4,199, Processing Time 0.031 seconds

Interactive analysis tools for the wide-angle seismic data for crustal structure study (Technical Report) (지각 구조 연구에서 광각 탄성파 자료를 위한 대화식 분석 방법들)

  • Fujie, Gou;Kasahara, Junzo;Murase, Kei;Mochizuki, Kimihiro;Kaneda, Yoshiyuki
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.1
    • /
    • pp.26-33
    • /
    • 2008
  • The analysis of wide-angle seismic reflection and refraction data plays an important role in lithospheric-scale crustal structure study. However, it is extremely difficult to develop an appropriate velocity structure model directly from the observed data, and we have to improve the structure model step by step, because the crustal structure analysis is an intrinsically non-linear problem. There are several subjective processes in wide-angle crustal structure modelling, such as phase identification and trial-and-error forward modelling. Because these subjective processes in wide-angle data analysis reduce the uniqueness and credibility of the resultant models, it is important to reduce subjectivity in the analysis procedure. From this point of view, we describe two software tools, PASTEUP and MODELING, to be used for developing crustal structure models. PASTEUP is an interactive application that facilitates the plotting of record sections, analysis of wide-angle seismic data, and picking of phases. PASTEUP is equipped with various filters and analysis functions to enhance signal-to-noise ratio and to help phase identification. MODELING is an interactive application for editing velocity models, and ray-tracing. Synthetic traveltimes computed by the MODELING application can be directly compared with the observed waveforms in the PASTEUP application. This reduces subjectivity in crustal structure modelling because traveltime picking, which is one of the most subjective process in the crustal structure analysis, is not required. MODELING can convert an editable layered structure model into two-way traveltimes which can be compared with time-sections of Multi Channel Seismic (MCS) reflection data. Direct comparison between the structure model of wide-angle data with the reflection data will give the model more credibility. In addition, both PASTEUP and MODELING are efficient tools for handling a large dataset. These software tools help us develop more plausible lithospheric-scale structure models using wide-angle seismic data.

Ammonia Removal Capacities of Several Filter Media in a Seawater Recirculating Aquaculture System (해수 순환 여과 양식 시설의 여과 재료별 암모니아 제거 능력)

  • 전임기;손맹현;조재윤;이종문
    • Journal of Aquaculture
    • /
    • v.10 no.3
    • /
    • pp.261-271
    • /
    • 1997
  • Ammonia removal capacities of five submerged filter media, 2~3mm sand, 30~50mm gravel, 20~40mm coral sand, polythylene net, and corrugated plastic plate in a seawater recirculating system were tested. A rotating biological contactor (RBC) was also tested for comparison. Oxygen consumption rates were measured along with the ammonia removal efficiencies. The ammonia concentrations in the system were maintained from 0.052 to 0.904 mg/l (mean 0.338$\pm$0.219 mg/l) and the water temperature was ranged from 19.2 to $21.4^{\circ}C\;(mean 20.2^{\circ}C\pm0.58^{\circ}C$). The 1/2-order kinetic model (Y:g/$m^3$/day) and the mean ammonia removal rates (g/$m^3$/day) of the filter media were : Sand : Y=135.5X0.5-25.1(r2=0.8110), 45.1 Coral sand : Y=125.1X0.5-33.0 (r2=0.7307), 31.8 Polyethylene net : Y=87.4X0.5-20.1 (r2=0.6780), 25.2 Corrugated plastic plate : Y=87.4X0.5-20.1(r2=0.5206), 19.2 Gravel : Y=4307X0.5-5.5 (r2=0.2596), 17.1 RBC : Y=127.6X0.5-33.4 (r2=0.7146), 32.8 where X is the concentration of ammonia. Oxygen consumption rates well corresponded to the ammonia removal capacities of each filter medium, thus the sands showing the highest value (442g/$m^3$/day) followed by coral sands (291.1g/$m^3$/day), polyethylene nets (236.9g/$m^3$/day), gravels (135.6g/$m^3$/day) and corrugated plastic plates (134.2g/$m^3$/day). Oxygen consumption rate of the RBC was unable to measure because of the characteristics of the structure.

  • PDF

Changes of characteristics of livestock feces compost pile during composting period and land application effect of compost (축분 퇴비화과정 중 특성변화와 축분퇴비 이용효과)

  • Jeong, Kwang-Hwa;Kang, Ho
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.9 no.1
    • /
    • pp.56-64
    • /
    • 2001
  • Composting of livestock feces is economic and safe process to decrease the possibility of direct leakage of organic pollutants to ecosystem from commercial and environmental point of view. This study was conducted with three different experiments related to composting of livestock feces. The purpose of experiment 1 was to investigate changes of characteristic of compost pile during composting period by low temperature in cold season. To compare composting effect of experimental compost pile and control pile exposed in cold air, experimental compost piles were warmed up by hot air until their temperatures were reached at $35^{\circ}C$. Sawdust, Ricehull and Ricestraw were mixed with livestock feces as bulking agent. The highest temperatures of compost pile during composting period were in sawdust, rice hull, rice straw, and control were $75^{\circ}C$, $76^{\circ}C$, $68^{\circ}C$, $45^{\circ}C$ respectively. Moisture content, pH, C/N and volume of compost were decreased during composting period. Experiment 2 was carried out to study utilization effect of compost by plant. A corn was cultivated for 3 years on fertilized land with compost and chemical fertilizer. The amount of harvest and nutrition value of corn were analyzed. In first year of trial, the amount of harvest of corn on land treated with compost was lower by 20% than that of land treated with chemical fertilizer. In second year, there was no difference in yield of com between compost and chemical fertilizer. In third year, the yield of com on land fertilized with compost was much more than that of land fertilized with chemical fertilizer. The purpose of experiment 3 was to estimate the decrease of malodorous gas originating from livestock feces by bio-filter. Four types of bio-filters filled with saw dust, night soil, fermented compost and leaf mold were manufactured and tested. Each bio-filter achieved 87-95% $NH_3$ removal efficiency. This performance was maintained for 10 days. The highest $NH_3$ removal efficiency was achieved by leaf mold on the first day of operation period. It reduced the concentration of $NH_3$ by about 95%. Night soil and fermented compost showed nearly equal performance of 93 to 94% for 10 days from the beginning of operation. The concentration of hydrogen sulfide and methyl mercaptan originating for compost were equal to or less than $3mg/{\ell}$ and $2mg/{\ell}$, respectively. After passing throughout the bio-filter, hydrogen sulfide and methyl mercaptan were not detected.

  • PDF

Study on the Photoneutrons Produced in 15 MV Medical Linear Accelerators : Comparison of Three-Dimensional Conformal Radiotherapy and Intensity-Modulated Radiotherapy (15 MV 의료용 선형가속기에서 발생되는 광중성자의 선량 평가 - 3차원입체조형방사선치료와 세기조절방사선치료의 비교 -)

  • Yang, Oh-Nam;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.335-343
    • /
    • 2012
  • Intensity-modulated radiotherapy(IMRT) have the ability to provide better dose conformity and sparing of critical normal tissues than three-dimensional radiotherapy(3DCRT). Especially, with the benefit of health insurance in 2011, its use now increasingly in many modern radiotherapy departments. Also the use of linear accelerator with high-energy photon beams over 10 MV is increasing. As is well known, these linacs have the capacity to produce photonueutrons due to photonuclear reactions in materials with a large atomic number such as the target, flattening filters, collimators, and multi-leaf collimators(MLC). MLC-based IMRT treatments increase the monitor units and the probability of production of photoneutrons from photon-induced nuclear reactions. The purpose of this study is to quantitatively evaluate the dose of photoneutrons produced from 3DCRT and IMRT technique for Rando phantom in cervical cancer. We performed the treatment plans with 3DCRT and IMRT technique using Rando phantom for treatment of cervical cancer. An Rando phantom placed on the couch in the supine position was irradiated using 15 MV photon beams. Optically stimulated luminescence dosimeters(OSLD) were attached to 4 different locations (abdomen, chest, head and neck, eyes) and from center of field size and measured 5 times each of locations. Measured neutron dose from IMRT technique increased by 9.0, 8.6, 8.8, and 14 times than 3DCRT technique for abdomen, chest, head and neck, and eyes, respectively. When using IMRT with 15 MV photonbeams, the photoneutrons contributed a significant portion on out-of-field. It is difficult to prevent high energy photon beams to produce the phtoneutrons due to physical properties, if necessary, It is difficult to prevent high energy photon beams to produce the phtoneutrons due to physical properties, if necessary, it is need to provide the additional safe shielding on a linear accelerator and should therefore reduce the out-of-field dose.

Preparation and Biodistribution of Re-188 Sulfur Colloid (Re-188이 표지된 황 교질(Sulfur Colloid) 제조와 생체내 분포)

  • Kim, Young-Ju;Jeong, Jae-Min;Chang, Young-Soo;Lee, Yong-Sin;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Song, Yeong-Wook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.298-304
    • /
    • 1998
  • Purpose: We evaluated the usefulness of Re-188 sulfur colloid for radiation synovectomy and therapy of intraperitoneal metastasis. Materials and Methods: We investigated the labeling efficiency of Re-188 sulfur colloid on various conditions. The stability of Re-188 sulfur colloid was observed at room temperature for 24 h and in human serum and synovial fluid for 72 h. The particle size distribution of Re-188 sulfur colloid was measured by filtering with various pore size filters. Animal experiment was performed in mice and rabbits. Results: The labeling efficiency of Re-188 sulfur colloid was $64.5{\pm}5.8%$ (n=5) at the conditions of sodium thiosulfate 40 mg, EDTA $Na_2.2H_2O$ 0.8 mg, $KReO_4$ 0.8 mg at pH 1. After purification, the radiochemical purity was higher than 99%. The stability of Re-188 sulfur colloid was high (>99%) at room temperature for 24 h and in human serum and synovial fluid for 72 h. The particle size distribution of Re-188 sulfur colloid was 0.3% ($<1{\mu}m$), 11.2% ($1{\sim}5{\mu}m$), 25.8% ($5{\sim}10{\mu}m$) and 52.8% ($>10{\mu}m$). In mice, 1 h postinjection of Re-188 sulfur colloid into tail vein, uptakes in lung, liver and muscle were $37.30{\pm}5.36$, $32.33{\pm}1.79$, $6.60{\pm}0.02%$ ID/organ respectively. After i.p. injection in mice, the uptakes of extraperitonial organs of Re-188 sulfur colloid at 1 and 24 h were $0.1{\pm}0.1$, $0.4{\pm}0.1%$ ID/organ, and the excretions through urine and feces (${\sim}70 h$) were low ($2.68{\pm}0.80$, $0.95{\pm}0.17%$). When Re-188 sulfur colloid was injected to synovial space of rabbit, the uptake in other organs except knee was very low. Conclusion: Re-188 sulfur colloid showed high labeling efficiency, stability and potency for clinical use.

  • PDF

Performance Measurement of Diagnostic X Ray System (진단용 X선 발생장치의 성능 측정)

  • You, Ingyu;Lim, Cheonghwan;Lee, Sangho;Lee, Mankoo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.447-454
    • /
    • 2012
  • To examine the performance of a diagnostic X-ray system, we tested a linearity, reproducibility, and Half Value Layer(HVL). The linearity was examined 4 times of irradiation with a given condition, and we recorded a level of radiation. We then calculated the mR/mAs. And the measured value should not be more than 0.1. If the measured value was more than 0.1, we could know that the linearity was decreased. The reproducibility was analyzed 10 times of irradiations at 80kVp, 200mA, 20mAs and 120kVp, 300mA, 8mAs. The values from these analyses were integrated into CV equation, and we could get outputs. The reproducibility was good if the output was lower than 0.05. HVL was measured 3 times of irradiation without a filter, and we inserted additional HLV filters with 0, 1, 2, 4 mm of thickness. We tested the values until we get the measured value less than a half of the value measured without additional filter. We tested the linearity, the reproducibility, and HVL of 5 diagnostic X-ray generators in this facilities. The linearity of No. 1 and No. 5 generator didn't satisfy the standard for radiation safety around 300mA~400mA and 100mA~200mA, respectively. HVL of No.1 generator was not satisfied at 80kVp. The outputs were higher in the three-phase equipment than the single-phase equipment. The old generators need to maintain and exchange of components based on the these results. Then, we could contribute to getting more exact diagnosis increasing a quality of the image and decreasing an expose dose of radiation.

Combination of Hydrophobic Filtration and Enrichment Methods for Detecting Bacillus cereus in Fresh-Cut Cabbage

  • Lee, Sujung;Choi, Yukyung;Lee, Heeyoung;Kim, Sejeong;Lee, Jeeyeon;Ha, Jimyeong;Oh, Hyemin;Lee, Yewon;Kim, Yujin;Yoon, Yohan;Lee, Soomin
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.5
    • /
    • pp.325-329
    • /
    • 2018
  • This study developed a rapid detection method for Bacillus cereus in fresh-cut cabbages. Fresh-cut cabbage samples were inoculated at 1-, 2- and 3-Log CFU/g, and pathogens were enriched in tryptic soy broth containing 0.15% polymyxin B at $30^{\circ}C$, $37^{\circ}C$, and $42^{\circ}C$ to determine the detection limit and appropriate enrichment temperature for multiplex PCR detection. Enriched bacterial cells in enrichment broth were collected in a hydrophobic filter prior to DNA extraction for multiplex PCR. Filters were resuspended in distilled water, and DNA was extracted from the suspension. DNA samples were further analyzed by multiplex PCR. Detection limit of multiplex PCR was 5-Log CFU/mL. B. cereus cell counts were higher (P < 0.05) at $42^{\circ}C$ than other temperatures. Detection rate of 1-, 2-, and 3-Log CFU/g inoculated samples were 60%, 80%, and 100% after enrichment respectively. However, when enriched samples were filtered with hydrophobic membrane filter, detection rates became 100%, regardless of inoculation level. Results indicate a combination of enrichment with hydrophobic filtration improves rapid detection efficiency of B. cereus in fresh-cut cabbage by multiplex PCR.

Urban archaeological investigations using surface 3D Ground Penetrating Radar and Electrical Resistivity Tomography methods (3차원 지표레이다와 전기비저항 탐사를 이용한 도심지 유적 조사)

  • Papadopoulos, Nikos;Sarris, Apostolos;Yi, Myeong-Jong;Kim, Jung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.1
    • /
    • pp.56-68
    • /
    • 2009
  • Ongoing and extensive urbanisation, which is frequently accompanied with careless construction works, may threaten important archaeological structures that are still buried in the urban areas. Ground Penetrating Radar (GPR) and Electrical Resistivity Tomography (ERT) methods are most promising alternatives for resolving buried archaeological structures in urban territories. In this work, three case studies are presented, each of which involves an integrated geophysical survey employing the surface three-dimensional (3D) ERT and GPR techniques, in order to archaeologically characterise the investigated areas. The test field sites are located at the historical centres of two of the most populated cities of the island of Crete, in Greece. The ERT and GPR data were collected along a dense network of parallel profiles. The subsurface resistivity structure was reconstructed by processing the apparent resistivity data with a 3D inversion algorithm. The GPR sections were processed with a systematic way, applying specific filters to the data in order to enhance their information content. Finally, horizontal depth slices representing the 3D variation of the physical properties were created. The GPR and ERT images significantly contributed in reconstructing the complex subsurface properties in these urban areas. Strong GPR reflections and highresistivity anomalies were correlated with possible archaeological structures. Subsequent excavations in specific places at both sites verified the geophysical results. The specific case studies demonstrated the applicability of ERT and GPR techniques during the design and construction stages of urban infrastructure works, indicating areas of archaeological significance and guiding archaeological excavations before construction work.

A Study of Various Filter Setups with FBP Reconstruction for Digital Breast Tomosynthesis (디지털 유방단층영상합성법의 FBP 알고리즘 적용을 위한 다양한 필터 조합에 대한 연구)

  • Lee, Haeng-Hwa;Kim, Ye-Seul;Lee, Youngjin;Choi, Sunghoon;Lee, Seungwan;Park, Hye-Suk;Kim, Hee-Joung;Choi, Jae-Gu;Choi, Young-Wook
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.271-280
    • /
    • 2014
  • Recently, digital breast tomosynthesis (DBT) has been investigated to overcome the limitation of conventional mammography for overlapping anatomical structures and high patient dose with cone-beam computed tomography (CBCT). However incomplete sampling due to limited angle leads to interference on the neighboring slices. Many studies have investigated to reduce artifacts such as interference. Moreover, appropriate filters for tomosynthesis have been researched to solve artifacts resulted from incomplete sampling. The primary purpose of this study is finding appropriate filter scheme with FBP reconstruction for DBT system to reduce artifacts. In this study, we investigated characteristics of various filter schemes with simulation and prototype digital breast tomosynthesis under same acquisition parameters and conditions. We evaluated artifacts and noise with profiles and COV (coefficinet of variation) to study characteristic of filter. As a result, the noise with parameter 0.25 of Spectral filter reduced by 10% in comparison to that with only Ramp-lak filter. Because unbalance of information reduced with decreasing B of Slice thickness filter, artifacts caused by incomplete sampling reduced. In conclusion, we confirmed basic characteristics of filter operations and improvement of image quality by appropriate filter scheme. The results of this study can be utilized as base in research and development of DBT system by providing information that is about noise and artifacts depend on various filter schemes.

Enhancement of Inter-Image Statistical Correlation for Accurate Multi-Sensor Image Registration (정밀한 다중센서 영상정합을 위한 통계적 상관성의 증대기법)

  • Kim, Kyoung-Soo;Lee, Jin-Hak;Ra, Jong-Beom
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.4 s.304
    • /
    • pp.1-12
    • /
    • 2005
  • Image registration is a process to establish the spatial correspondence between images of the same scene, which are acquired at different view points, at different times, or by different sensors. This paper presents a new algorithm for robust registration of the images acquired by multiple sensors having different modalities; the EO (electro-optic) and IR(infrared) ones in the paper. The two feature-based and intensity-based approaches are usually possible for image registration. In the former selection of accurate common features is crucial for high performance, but features in the EO image are often not the same as those in the R image. Hence, this approach is inadequate to register the E0/IR images. In the latter normalized mutual Information (nHr) has been widely used as a similarity measure due to its high accuracy and robustness, and NMI-based image registration methods assume that statistical correlation between two images should be global. Unfortunately, since we find out that EO and IR images don't often satisfy this assumption, registration accuracy is not high enough to apply to some applications. In this paper, we propose a two-stage NMI-based registration method based on the analysis of statistical correlation between E0/1R images. In the first stage, for robust registration, we propose two preprocessing schemes: extraction of statistically correlated regions (ESCR) and enhancement of statistical correlation by filtering (ESCF). For each image, ESCR automatically extracts the regions that are highly correlated to the corresponding regions in the other image. And ESCF adaptively filters out each image to enhance statistical correlation between them. In the second stage, two output images are registered by using NMI-based algorithm. The proposed method provides prospective results for various E0/1R sensor image pairs in terms of accuracy, robustness, and speed.