Performance Evaluation of Digital Radiography Antiscatter Grids using Film Digitizers

  • Lee, Hyoung-Koo;Lee, Jung-Ae;Kim, Sung-Hyun;Ho, Dong-Su;Kim, Do-Il;Suh, Tae-Suk;Choe, Bo-Young;Kim, Jin-Soo;Kim, Jin-Won
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.393-395
    • /
    • 2002
  • We propose a method which can replace the DR when measuring performance evaluation parameters of antiscatter grids for DR. We used conventional x-ray films to produce grid images, which were scanned by a film digitizer. The digitizer could provide sampling interval of 87 micrometers and pixel depth of 12 bits. Grid line frequencies were measured using aliasing effect and non-uniformities of grids were measured by transforming scanned pixel values of film images into optical densities.

  • PDF

Radiochromic film dosimetry for linac-based stereotactic radiosurgery

  • Han, Seung-Hee;Park, Suk-Won;Oh, Do-Hoon
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.302-304
    • /
    • 2002
  • In linac-based stereotactic radiosurgery, assuring the quality of the planning and delivery of external photon beam requires accurate evaluation of beam parameters, usually including output factors, tissue-phantom ratio and off-axis ratios, and measurement of actual dose distributions from simulated treatment. We're going to test the use of calibrated radio chromic film (Gafchromic film; type MD-55, Nuclear associate) using a Lumiscan 75 digitizer to measure absolute dose and relative dose distributions for linac-based radiosurgery unit Relative dose distribution of a human-style spherical acryl phantom were measured using radiochromic film and calculated by treatment planning system. The absolute dose at the sphere center was measured by radiochromic film and micro chamber (Exradin A-14, 0.009cc). What we want to demonstrate in this work, the 'well selected' radiochromic films when external photon beam are used in linac-based stereotactic radiosurgery are very accurate detector for dosimetry.

  • PDF

자동현상기 지능화에 필요한 연산처리 기법의 개발을 위한 방사선 필름의 영상 지수의 분석 (Analysis of Image Factors of X-ray Films: Study for the Intelligent Replenishment System of Automatic Film Processor)

  • 박성태;윤종현;박광보;오용호;이형진;인경환;김건중
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제21권1호
    • /
    • pp.35-39
    • /
    • 1998
  • We analyzed image factors to determine the characteristic factors that need for intelligent replenishment system of the auto film processor. We processed the serial 300 sheets of radiographic films of chest phantom without replenishment of developing and fixation replenisher. We took the digital data by using film digitizer which scaned the films and automatically summed up the pixel values of the films. We analyzed characteristic curves, average gradients and relative speeds of individual film using densitometer and step densitometry. We also evaluated the pH of developer, fixer, and washer fluid with digital pH meter. Fixer residual rate and washing effect were measured by densitometer using the reagent methods. There was no significant reduction of the digital density numbers of the serial films without replenishment of developer and fixer. The average gradients were gradually decreased by 0.02 and relative speeds were also gradually decreased by 6.96% relative to initial standard step-densitometric measurement. The pHs of developer and fixer were reflected the inactivation of each fluid. The fixer residual rates and washing effects after processing each 25 sheets of films were in the normal range. We suggest that the digital data are not reliable due to limitation of the hardware and software of the film digitizer. We conclude that average gradient and relative speed which mean the film's contrast and sensitivity respectively are reliable factors for determining the need for the replenishment of the auto film processor. We need more study of simpler equations and programming for more intelligent replenishment system of the auto film processor.

  • PDF

복부 CT 영상에서 신장암의 자동추출 (Automatic Detection of Kidney Tumor from Abdominal CT Scans)

  • 김도연;노승무;조준식;김종철;박종원
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제29권11호
    • /
    • pp.803-808
    • /
    • 2002
  • 본 논문은 복부 컴퓨터단층촬영(CT) 영상에서의 자동화된 신장 및 신장암 추출에 관한 연구를 수행하였다. 필름으로 보관된 복부 CT 영상을 디지털화하여 영상분석을 수행하였으며, 명암값에 의한 임계값(Gray-Level Thresholding) 처리 기법을 사용하여 신장만을 분리하였다. 신장암의 샘플영상에 대한 텍스쳐(Texture)분석 결과를 토대로, 대표적인 통계적 모멘트 값인 평균 및 표준 편차값을 동질성 시험 기준으로 삼아 신장암의 SEED를 선택하였다. 선택된 SEED의 중앙 픽셀을 시작점으로 하여, 명암값을 동질성 시험기준으로 사용한 영역확장(Region Growing) 방법을 적용하여 신장암을 추출하였다. GE사의 Hispeed Advantage CT 스캐너를 사용하여 촬영된 9개의 예, 총 113매 영상을 Lumisys LS-40 필름 디지타이저로 디지털화 하여 적용한 결과, 85%의 신장암 추출 민감도를 가진다.

선형가속기를 이용한 정위방사선 치료 시 GafChromic Film을 이용한 선량측정 (GafChromic Film Dosimetry for Stereotactic Radiosurgery with a Linear Accelerator)

  • 한승희;조병철;박석원;오도훈;박희철;배훈식
    • Radiation Oncology Journal
    • /
    • 제21권2호
    • /
    • pp.167-173
    • /
    • 2003
  • 목적: 선형가속기를 이용한 정위방사선치료 시 GafChromic 필름을 이용하여 조사되는 선량 및 분포를 측정하고 치료 계획에서 계산된 선량분포와의 일치 여부를 평가하고자 하였다. 대상 및 방법: 두부 모형의 아크릴 팬텀을 제작하였는데, 팬텀 중심과 또 다른 두 지점에서 전리함을 삽입하거나, 임의 단면에서 필름을 삽입하여 절대선량 및 상대선량분포를 측정할 수 있도록 하였다. GafChromic 필름(MD-55-2, Nuclear Associate, USA)을 폴리스티렌 고체 팬텀 깊이 5 cm에 삽입하여 6 MV 광자선, 0$\~$l12 Gy 선량으로 조사하고, Digitizer를 이용하여 흑화도(Optical density: OD)를 측정하였다. 본원에서 개발한 정위방사선 치료계획시스템 'Linapel'을 이용하여 두부 모형의 아크릴 팬텀의 중심점(Isocenter of Target)을 대상으로, 각각의 빔에 300 cGy 선량이 조사되도록 5 arc 빔 치료계획을 시행하였다. 필름선량측정시스템(RIT113 프로그램)을 이용하여 5 arc 빔 전체가 조사된 GafChromic 필름의 상대선량분포를 측정하고 치료계획에서 계산된 선량분포와 비교하였다. 결과: MD-55-2 GafChromic필름에 대한 흑화도는 조사된 선량에 대하여 선형성을 가지고 있음을 확인하였다. 깊이 변화에 대한 선량 값의 변화와 빔의 횡축에 대한 빔 측면상(profile)도 GafChromic 필름을 이용하여 측정할 수 있었다. 치료계획시스템 'Linapel'을 이용한 치료계획의 선량 계산 값과 측정에서 얻은 절대선량 값을 비교하면 오차범위가 $\pm$3$\%$ 이내에 있음을 확인하였다. GafChromic 필름의 실제 조사된 상대선량분포도를 치료 계획에서 결정된 선량분포도와 비교하면 50$\~$90$\%$에 대하여 $\pm$1 mm의 차이를 가지고 있음을 확인할 수 있었다. 결론: 본 연구를 통하여 GafChromic 필름은 절대선량과 상대선량분포를 측정할 수 있다는 것을 확인시켜 줌으로써, 선형가속기를 이용하는 정위방사선치료에서 치료 전에 선량측정을 위한 방법으로 믿을 만한 정보를 제공할 수 있는 방법으로 생각된다.

Practical Implementation of Patient-Specific Quality Assurance for Small and Multiple Brain Tumors in CyberKnife with Fixed Collimators

  • Lee, Eungman;Park, Kwangwoo;Kim, Jin Sung;Kim, Yong Bae;Lee, Ho
    • 한국의학물리학회지:의학물리
    • /
    • 제29권2호
    • /
    • pp.53-58
    • /
    • 2018
  • This paper evaluates patient-specific quality assurance (PSQA) in the treatment of small and multiple tumors by the CyberKnife system with fixed collimators, using an ion chamber and EBT3 films. We selected 49 patients with single or multiple brain tumors, and the treatment plans include one to four targets with total volumes ranging from 0.12 cc to 3.74 cc. All PSQA deliveries were performed with a stereotactic dose verification phantom. The A16 microchamber (Standard Imaging, WI, USA) and Gafchromic EBT3 film (Ashland ISP Advanced Materials, NJ, USA) were inserted into the phantom to measure the point dose of the target and the dose distribution, respectively. The film was scanned 1 hr after irradiation by a film digitizer scanner and analyzed using RIT software (Radiological Imaging Technology, CO, USA). The acceptance criteria was <5% for the point dose measurement and >90% gamma passing rate using 3%/3 mm and relative dose difference, respectively. The point dose errors between the calculated and measured dose by the ion chamber were in the range of -17.5% to 8.03%. The mean point dose differences for 5 mm, 7.5 mm, and 10 mm fixed cone size was -11.1%, -4.1%, and -1.5%, respectively. The mean gamma passing rates for all cases was 96.1%. Although the maximum dose distribution of multiple targets was not shown in the film, gamma distribution showed that dose verification for multiple tumors can be performed. The use of the microchamber and EBT3 film made it possible to verify the dosimetric and mechanical accuracy of small and multiple targets. In particular, the correction factors should be applied to small fixed collimators less than 10 mm.

Laser 방식 및 CCD 방식 Film Digitizer의 균일도 비교평가

  • 강원석;정해조;민덕기;김새롬;이상호;김희중
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.80-80
    • /
    • 2003
  • 디지털 의료영상 획득기술과 컴퓨터 및 네트워크 기술의 발달로 현재 각 병원에서는 PACS(Picture Archiving and Communication System)를 설치하여 필름을 사용하지 않고 진단과 진료를 하는 병원이 증가하고 있으며, 이에 따라 기존 필름상태의 의료영상은 필름디지타이저로 디지털 영상화한 후 모니터를 통하여 판독과 진료에 이용하고 있다. 본 연구에서는 현재 세브란스병원에서 사용되고 있는 CCD 방식 필름디지타이저와 레이저 스캐너방식 필름디지타이저의 픽셀값 균일도에 대해 중점적으로 비교, 분석하고자 한다. 픽셀값 균일도 측정을 위해 필름프린터를 이용하여 균일한 광학밀도를 가진 필름을 출력하였다. 그 테스트 필름은 각 사분면에 각기 다른 광학밀도를 가지고 있었으며, 그 광학밀도 값은 각각 0.19, 0.71, 1.41, 그리고 3.10 이었다. 제작된 필름은 레이저 (Model 2905, Array Corp., Japan) 방식과 CCD 방식 (SEDAS Media Film Scanner, Kodak, japan) 디지타이저에 의해 디지털화 되었다. 그 영상들은 다시 분석을 위해 PACS를 통해 PC로 전송되어졌고 자체 제작된 소프트웨어를 이용하여 균일도에 대한 분석을 수행하였다. 하나의 사분면 영상에 대하여 일정한 간격과 크기로 20개의 ROI를 만들고, 그 내부의 픽셀값들의 평균값을 구하여 그 영역의 대푯값으로 하였다. 그 대푯값들 중 최대값과 최소값의 차이에 대한 백분율로써 균일도를 표시하였다. 그 결과 광학밀도가 0.19인 사분변의 영상에서의 균일도는 레이저 방식 및 CCD 방식 각각에서 99.8%, 94.3%였으며, 0.71인 사분면에서는 99.4%, 75.6%, 1.41 일때는 97.9%, 62.96%, 그리고 3.1인 사분면에서는 82.7%, 53.7%였다. 같은 광학밀도를 가진 사분면에서는 레이저방식의 균일도가 CCD 방식에 비해 더 우수함을 알 수 있었으며, 같은 방식에서 얻은 영상이라 할지라도 광학 밀도값이 높은 사분변에서 얻은 영상일수록 균일도가 떨어짐을 알 수 있었다. 결론적으로, 레이저 방식 필름 디지타이저는 균일도 면에서도 CCD 방식에 비해 우수함을 알 수 있었으며 CCD 방식은 백라이트의 균일도가 영상의 균일도에 영향을 미칠수도 있는 만큼 향후 거기에 대한 연구도 이루어져야 할 것으로 생각된다.

  • PDF

Evolution of Large-Scale Filmless Full-PACS in Korea

  • Kim, Hee-Joung;Haijo Jung;Yoo, Hyung-Sik
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.28-31
    • /
    • 2002
  • Filmless full-PACS in korea has rapidly been growing, since government had supported collaborative PACS project between industry and university hospital in late of 1995. At the same time, a small company had started PACS business, while the Korea PACS society was being formed. In the beginning, PACS societies had focused on developing peripheral solutions such as DICOM gateway for image acquisition, x-ray film digitizer, and viewing software for research or management of personal image data, while Samsung Medical Center had started installing an imported partial PACS system which had recently upgraded with a new system. In similar time frame, a few hospitals had started developing and installing domestic large scale full-PACS system. Several years later, many hospitals have installed full-PACS system with national policy of reimbursement for PACS exams in November 1999. It is believed that Korea is the first country that adopted PACS reimbursement for filmless full-PACS as a national policy. Both experiences of full-PACS installation and national policy generated tremendous intellectual and technological expertise about PACS at all levels, clinical, hospital management, education, and industrial sectors. There are currently three types of PACS system which includes domestic, imported, and hybrid PACS system with imported solution for core system and domestic solution for peripheral system. There are more than 20 domestic PACS companies and they have now enough experiences so that they are capable of installing a truly full-PACS system for large-scale teaching hospitals. PACS societies in Korea understand how to design, implement, install, manage, sustain, and provide good services for large-scale full-PACS. PACS society has also strength for the highest integration technology of the Hospital Information. However, further understanding and timely implementation of continuously evolving international standard and integrated healthcare enterprise concepts may be necessary for international leading of PACS technologies for the future.

  • PDF

상악 제1 소구치의 치근면 함요도 및 치근표면적에 관한 연구 (A STUDY OF THE DEPTH OF THE ROOT CONCAVITY AND ROOT SURFACE AREA MEASUREMENT OF THE MAXILLARY FIRST PREMOLAR)

  • 임상철;권영혁;이만섭
    • Journal of Periodontal and Implant Science
    • /
    • 제24권1호
    • /
    • pp.165-177
    • /
    • 1994
  • To investigate the depth of the root concavity and root surface area of the maxillary first premolar, 40 maxillary first premolars were used. All the teeth which extracted because of advanced periodontal disease and orthodontic treatment procedure, were sectioned every 1.5mm from cementoenameljunction to the apex with hard tissue microtome. Each sectioned root was taken photograph with slide film, and projected for measuring with a calibrated digital Curvi-Meter. The root surface area, percentage of the RSA and the linear variation of the RSA were calibrated for each 1.5mm section. Linear variation of the depth of root concavity was measured on mesial and distal root surface for each section using computer-aided digitizer. The results were as follows. 1. The total mean root length of maxillary first premolar was 13.48mm. Mean buccal root length of 2-rooted tooth was 12.59mm, mean palatal root length was 12.73mm, and mean root length of single rooted tooth was 13.78mm. 2. The total mean root surface area of maxillary first premolar was $194.17mm^2$, mean root surface area for 2-rooted tooth was $205.97mm^2$ and mean root surface area for single rooted tooth was $188.49mm^2$. 3. It was 59.93% of the total root surface area that the area from CEJ to coronal 6mm. And, the coronal half of the root length accounted for approximately 71.76% of the total root surface area. 4. Most deepest concavity of the mesial root surface was 0.65mm at apical 3.0mm, 4.5mm level in maxillary first premolar. And, that of the distal root surface was 0.37mm at apical 4.5mm level. 5. All of the maxillary first premolar had mesial root surface concavity. This mesial root surface concavity appeared to be more pronounced in 2-rooted tooth than single rooted tooth.

  • PDF