• 제목/요약/키워드: filling defect

검색결과 135건 처리시간 0.027초

A NOVEL APPROACH TO COMPACTLY BRAZE ALUMINUM ALLOYS

  • Qian, Yiyu;Dong, Zhangui;Liu, Jun
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.545-550
    • /
    • 2002
  • In order to ensure the signal could be transported cocrrectly, the microwave devices made of Aluminmn alloys must be assembled and brazed flaw-freely. In this paper, a new approach of using contact reactive brazing (CRB) process to realize the compact brazing of Aluminum alloys was put forward. The reason for this is that CRB, which realizes bonding depending on the liquid alloy produced by metallurgy reaction between the materials to be joined, overcomes the limitation of traditional brazing that the macroscopically disorganized filling flow of liquid filler metal would result in defects in brazed seam. Joint ofLF21 (AA3003) with the compactness of over 95% was brazed by the method of CRB using Si powder as an interlayer. At last, the influence of the physical parameter related to the Si powder interlayer on the compactness of the joints was investigated in detail.

  • PDF

객혈을 주소로 폐용적 감소를 동반한 32세 여자환자 (A 32 Years-old Female Accompanied by the Loss of Lung Volume, Complained of Hemoptysis)

  • 서기현;문승혁;김용훈
    • Tuberculosis and Respiratory Diseases
    • /
    • 제52권3호
    • /
    • pp.288-293
    • /
    • 2002
  • 저자들은 객혈을 주소로 내원하여 선천성 폐동맥 부발육증으로 오인한 32세 여자환자를 폐색전증으로 진단하였고, 항응고제 투여를 통해 호전된 예를 문헌고찰과 함께 보고하는 바이다.

폴리머 몰드를 이용한 금속 나노분말의 미세부품 제조 (Fabrication of Micro Component of Metallic Nano Powder Using Polymer Mold)

  • 이우석;김상필;이혜문;배동식;최철진
    • 한국분말재료학회지
    • /
    • 제14권3호
    • /
    • pp.202-207
    • /
    • 2007
  • Novel polymer mold process for fabrication of microcomponents using metal nanopowders was developed and experimentally optimized. Polymer mold for forming green components was produced by using a hard master mold and polydimethylsiloxane (PDMS). In the preparation of metallic powder premix for the green components without any defect, 90 wt.% 17-4PH statinless steel nanopowders and 10 wt.% organic binder were mixed by a ball milling process. The green components with very clear gear shape were formed by filling the powder premix into the PDMS soft mold in surrounding at about $100^{\circ}C$. Cold isostatic pressing (CIP) was very potent process to decrease a porosity in the sintered microcomponent. The microgear fabricated by the improved process showed a good dimension tolerance of about 1.2%.

식도 해면상 혈관종 - 1례 보고 - (Cavernous Hemangioma of the Esophagus - One Case Report -)

  • 목형균;신호승;홍기우
    • Journal of Chest Surgery
    • /
    • 제32권9호
    • /
    • pp.851-854
    • /
    • 1999
  • 식도에서 발생한 혈관종은 전 세계적으로 30례 정도가 보고된 매우 드문 질환이다. 일반적으로 남자에 서 흔하고 증상이 없는 경우가 대부분이나, 연하 곤란 및 출혈 등이 있을 수 있다. 진단은 바륨 식도 조 영술과 내시경을 통해 이루어지고, 치료 방법은 내시경적 절제술과 개흉을 통한 절제술이 있다. 환자는 연하 곤란과 소화 불량을 주소로 내원한 46세 남자로 식도 조영술, 내시경 검사상 식도 중하부의 점막하 종양이 추정되어 수술을 시행하였다. 개흉수술을 통해 절제하였고 조직 검사상 해면상 혈관종으로 확진 되었다. 수술후 합병증이 없이 퇴원하였으며 수술후 관찰 추적중인데, 재발없이 양호한 상태를 보이고 있다.

  • PDF

뇌동맥류의 수술 중 뇌혈관 조영술의 역할 (Role of Intraoperative Angiography in the Surgical Treatment of Cerebral Aneurysms)

  • 심재홍
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권4호
    • /
    • pp.491-499
    • /
    • 2000
  • Objective : In the cerebral aneurysm surgery, the goal is complete circulatory exclusion of the aneurysm without compromise of normal vessels. In an operating room, an operator should confirm the completeness and precision of the surgical result, before closing the wound. Object of this study was to determine which cases require intraoperative angiography. Methods : We reported our experience with 48 intraoperative angiographic studies performed during the surgical treatment of cerebral aneurysm of these 48 cases. There were 5 giant(10.4%), 15 globular(1.5-2.5cm)(31.25%) and 28 saccular(58.3%) aneurysm. We recorded the incidence of unexpected findings, such as residual aneurysms, major vessel occlusions. Using Fischer's exact test, we assessed whether unexpected angiographic findings showed any correlation with aneurysm site, size and clinical findings. Results : In 5 cases(10.4%), we detected unexpected angiographic findings which resulted in clip adjustment. By means of clip adjustment, an operator could restore the flow of two major arterial occlusion(4.2%) and also obliterate three persistent filling aneurysms(6.3%). Globular aneurysm was the only factor to predict unexpected angiographic findings(p<0.05). The subgroup of globular and giant aneurysm has a high risk of occlusion of the parent artery and its branches and/or residual aneurysm. There were two minor complications related to this procedure. Conclusion : Intraoperative assessment makes it possible to recognize and correct the technical defect. Particularly in globular aneurysm, we were able to prevent both the chance for another operation and the risk of postoperative complications.

  • PDF

중자에서 발생한 가스 결함 위치 예측 (Prediction of Positions of Gas Defects Generated from Core)

  • 마쓰시타 마코토;코사카 아키라;카나타니 시게히로
    • 한국주조공학회지
    • /
    • 제42권1호
    • /
    • pp.61-66
    • /
    • 2022
  • Hydraulic units are important components of agricultural and construction machinery, and thus require high-quality castings. However, gas defects occurring inside the sand cores of the castings due to the resin used is a problem. This study therefore aimed to develop a casting simulation method that can clarify the gas defect positions. Gas defects are thought to be caused by gas generated after the molten metal fills up the mold cavity. The gas constant is the most effective factor for simulating this gas generated from sand cores. It is calculated by gas generating temperature and analysis of composition in the inert gas atmosphere modified according to the mold filling conditions of molten metal. It is assumed that gases generated from the inside of castings remain if the following formula is established. [Time of occurrence of gas generation] + [Time of occurrence of gas floating] > [Time of occurrence of casting surface solidification] The possibility of gas defects is evaluated by the time of occurrence of gas generation and gas floating calculated using the gas constant. The residual position of generated gases is decided by the closed loops indicating the final solidification location in the casting simulation. The above procedure enables us to suggest suitable casting designs with zero gas defects, without the need to repeat casting tests.

전.후방 압출품의 냉간단조 공정설계 (Process Design in Cold Forging of the Backward and Forward Extruded Part)

  • 민규식;최종웅;최재찬;김병민;조해용
    • 한국정밀공학회지
    • /
    • 제14권8호
    • /
    • pp.57-64
    • /
    • 1997
  • The process design of backward and forward extrusion of axisymmetric part has been studied in this paper. The important factors of cold forging process with complex geometry are the design of initial billet shape, the possibility of forming by one-stage operation and the determination of preform shapes, etc. Based on the systematic procedure of process sequence design, the forming operation of cold forged part is analyzed by the commercial finite element program, DEFORM. The design criteria are forming load, geo- metrical filling without defect and a sound distribution of effective strain in final product. It is noted that one step of preform operation is required to obtain the final product. Numerical result is compared with experi- mental one. It is found that the analyzed result is in good agreement with actual forming result.

  • PDF

Biliary ascariasis misidentified as a biliary stent in a patient undergoing liver resection

  • Hochang Chae;Suk Won Suh;Yoo Shin Choi;Hee Ju Sohn;Seung Eun Lee;Jae Hyuk Do;Hyun Jeong Park
    • Parasites, Hosts and Diseases
    • /
    • 제61권2호
    • /
    • pp.194-197
    • /
    • 2023
  • Ascaris lumbricoides causes one of the most common soil-transmitted helminthiases globally. The worms mostly infect the human small intestine and elicit negligible or nonspecific symptoms, but there are reports of extraintestinal ectopic ascariasis. We describe a rare case of biliary ascariasis mistaken for biliary stent in a 72-year-old female patient with a history of liver resection. She visited our outpatient clinic complaining of right upper quadrant pain and fever for the past week. She had previously undergone left lateral sectionectomy for recurrent biliary and intrahepatic duct stones 2 years ago. Besides mildly elevated gamma-glutamyl transferase levels, her liver function tests were normal. Magnetic resonance cholangiopancreatography revealed a linear filling defect closely resembling an internal stent from the common bile duct to the right intrahepatic bile duct. A live female A. lumbricoides adult worm was removed by endoscopic retrograde cholangiopancreatography (ERCP). Despite a significant decrease of the ascariasis prevalence in Korea, cases of biliary ascariasis are still occasionally reported. In this study, a additional case of biliary ascariasis, which was radiologically misdiagnosed as the biliary stent, was described in a hepatic resection patient by the worm recovery with ERCP in Korea.

Evaluation of bone substitutes for treatment of peri-implant bone defects: biomechanical, histological, and immunohistochemical analyses in the rabbit tibia

  • dos Santos, Pamela Leticia;de Molon, Rafael Scaf;Queiroz, Thallita Pereira;Okamoto, Roberta;de Souza Faloni, Ana Paula;Gulinelli, Jessica Lemos;Luvizuto, Eloa Rodrigues;Garcia, Idelmo Rangel Junior
    • Journal of Periodontal and Implant Science
    • /
    • 제46권3호
    • /
    • pp.176-196
    • /
    • 2016
  • Purpose: We sought to evaluate the effectiveness of bone substitutes in circumferential periimplant defects created in the rabbit tibia. Methods: Thirty rabbits received 45 implants in their left and right tibia. A circumferential bone defect (6.1 mm in diameter/4 mm depth) was created in each rabbit tibia using a trephine bur. A dental implant ($4.1mm{\times}8.5mm$) was installed after the creation of the defect, providing a 2-mm gap. The bone defect gaps between the implant and the bone were randomly filled according to the following groups: blood clot (CO), particulate Bio-Oss$^{(R)}$ (BI), and Bio-Oss$^{(R)}$ Collagen (BC). Ten animals were euthanized after periods of 15, 30, and 60 days. Biomechanical analysis by means of the removal torque of the implants, as well as histologic and immunohistochemical analyses for protein expression of osteocalcin (OC), Runx2, OPG, RANKL, and TRAP were evaluated. Results: For biomechanics, BC showed a better biological response ($61.00{\pm}15.28Ncm$) than CO ($31.60{\pm}14.38Ncm$) at 30 days. Immunohistochemical analysis showed significantly different OC expression in CO and BC at 15 days, and also between the CO and BI groups, and between the CO and BC groups at 60 days. After 15 days, Runx2 expression was significantly different in the BI group compared to the CO and BC groups. RANKL expression was significantly different in the BI and CO groups and between the BI and BC groups at 15 days, and also between the BI and CO groups at 60 days. OPG expression was significantly higher at 60 days postoperatively in the BI group than the CO group. Conclusions: Collectively, our data indicate that, compared to CO and BI, BC offered better bone healing, which was characterized by greater RUNX2, OC, and OPG immunolabeling, and required greater reversal torque for implant removal. Indeed, along with BI, BC presents promising biomechanical and biological properties supporting its possible use in osteoconductive grafts for filling peri-implant gaps.

5급와동의 복합레진 충전에 관한 유한요소법적 응력분석 (FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION ACCORDING TO CAVITY DESIGN OF CLASS V COMPOSITE RESIN FILLING)

  • 엄정문;권혁춘;손호현;조병훈;임영일
    • Restorative Dentistry and Endodontics
    • /
    • 제24권1호
    • /
    • pp.67-75
    • /
    • 1999
  • The use of composite restorative materials is established due to continuing improvements in the materials and restorative techniques. Composite resins are widely used for the restoration of cervical lesions because of esthetics, good physical properties and working time. There are several types of cavity design for class V composite resin filling, but inappropriate cavity form may affect bonding failure, microleakage and fracture during mastication. Cavity preparations for composite materials should be as conservative as possible. The extent of the preparation is usually determined by the size, shape, and location of the defect. The design of the cavity preparation to receive a composite restoration may vary depending on several factors. In this study, 5 types of class V cavity were prepared on each maxillary central incisor. The types are; 1) V-shape, 2) round(U) shape, 3) box form, 4) box form with incisal bevel and 5) box form with incisal bevel and grooves for axial line angles. After restoration, in order to observe the concentration of stress at bonding surfaces of teeth and restorations, developing a 2-dimensional finite element model of labiopalatal section in tooth, surrounding bone, periodontal ligament and gingiva, based on the measurements by Wheeler, loading force from direction of 45 degrees from lingual side near the incisal edge was applied. This study analysed Von Mises stress with SuperSap finite element analysis program(Algor Interactive System, Inc.). The results were as follows : 1. Stress concentration was prevalent at tooth-resin bonding surface of cervical side on each model. 2. In model 2 without line angle, stress was distributed evenly. 3. Preparing bevel eliminated stress concentration much or less at line angle. 4. Model with round-shape distributed stress concentration more evenly than box-type model with sharp line angle, therefore decreased possibility of fracture. 5. Adding grooves to line angles had no effect of decreasing stress concentration to the area.

  • PDF