• Title/Summary/Keyword: field verification

Search Result 1,272, Processing Time 0.035 seconds

Fitness-for-Service Assessment for Instrument Valve Material by Tensile Test for Verification (계기용 밸브 재질의 검증 인장시험에 의한 사용적합성 평가)

  • In Hwan Shin;Chi Yong Park
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.17 no.1
    • /
    • pp.49-55
    • /
    • 2021
  • In this paper, an application example for fitness-for-service of material is shown. A kind of instrument valve is made of austenitic stainless steel fabricated by the cold working process. The tensile strength of the cold worked austenitic stainless steel has to be limited under 90 ksi to prevent the stress corrosion cracking in power plants. In industrial fields, tensile strengths of some materials were discovered to be over the regulation requirements in a certified material test report (CMTR). Owner's verification tests were performed to compare with that in a CMTR and to check the appropriateness. It is found that, in the case of verification test under the required test speed, valve materials could be used in the field. Although it is only one application sample of material check process in the power generation site, this case study could show an importance of basic experimental technology in academia and research circles.

A Study for establishment of soil moisture station in mountain terrain (1): the representative analysis of soil moisture for construction of Cosmic-ray verification system (산악 지형에서의 토양수분 관측소 구축을 위한 연구(1): Cosmic-ray 검증시스템 구축을 위한 토양수분량 대표성 분석 연구)

  • Kim, Kiyoung;Jung, Sungwon;Lee, Yeongil
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.1
    • /
    • pp.51-60
    • /
    • 2019
  • The major purpose of this study is to construct an in-situ soil moisture verification network employing Frequency Domain Reflectometry (FDR) sensors for Cosmic-ray soil moisture observation system operation as well as long-term field-scale soil moisture monitoring. The test bed of Cosmic-ray and FDR verification network system was established at the Sulma Catchment, in connection with the existing instrumentations for integrated data provision of various hydrologic variables. This test bed includes one Cosmic-ray Neutron Probe (CRNP) and ten FDR stations with four different measurement depths (10 cm, 20 cm, 30 cm, and 40 cm) at each station, and has been operating since July 2018. Furthermore, to assess the reliability of the in-situ verification network, the volumetric water content data measured by FDR sensors were compared to those calculated through the core sampling method. The evaluation results of FDR sensors- measured soil moisture against sampling method during the study period indicated a reasonable agreement, with average values of $bias=-0.03m^3/m^3$ and RMSE $0.03m^3/m^3$, revealing that this FDR network is adequate to provide long-term reliable field-scale soil moisture monitoring at Sulmacheon basin. In addition, soil moisture time series observed at all FDR stations during the study period generally respond well to the rainfall events; and at some locations, the characteristics of rainfall water intercepted by canopy were also identified. The Temporal Stability Analysis (TSA) was performed for all FDR stations located within the CRNP footprint at each measurement depth to determine the representative locations for field-average soil moisture at different soil profiles of the verification network. The TSA results showed that superior performances were obtained at FDR 5 for 10 cm depth, FDR 8 for 20 cm depth, FDR2 for 30 cm depth, and FDR1 for 40 cm depth, respectively; demonstrating that those aforementioned stations can be regarded as temporal stable locations to represent field mean soil moisture measurements at their corresponding measurement depths. Although the limit on study duration has been presented, the analysis results of this study can provide useful knowledge on soil moisture variability and stability at the test bed, as well as supporting the utilization of the Cosmic-ray observation system for long-term field-scale soil moisture monitoring.

A Numerical Analysis for Blast Pressure and Impulse from Free-Air Burst (자유공중폭발에 의한 폭발압력과 충격량에 대한 수치해석)

  • Shin, Jinwon;Lee, Kyungkoo
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.4
    • /
    • pp.271-280
    • /
    • 2016
  • The need to accurate quantification of blast pressure loading in the near field is important because the focus of security design of critical infrastructure, buildings and bridges is for near-field detonations. Incident and reflected pressures for near-field detonations are very difficult to be measured by commercially available pressure transducers due to the high pressure and temperature, which requires a verified and validated computational fluid dynamics code to reasonably predict the near-field pressures and impulses. This paper presents numerical studies to verify and validate a CFD code for calculations of incident and reflected overpressures and impulses. The near field is emphasized and recommendations for mesh sizes to optimally simulate the near-field detonation are provided.

Development of Radar Beam Steering Measurement System and measurement Boresight Error (레이다 빔조향 특성 측정 장치 개발 및 보어 사이트 에러 측정)

  • Yong-kil Kwak
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.5
    • /
    • pp.546-551
    • /
    • 2023
  • In this study, a beam steering measurement system was developed to perform functions such as far-field beam steering and near-field beam focusing for TX/RX modes in the near file of the AESA radar. The beam steering measurement system consists of a spherical near-field scanner, an antenna positioner, a near-field controller, a network analyzer, a radar control system, a verification radar, a simulated radio, and an AESA radar. Using the developed system, the characteristics of TX/RX patterns before and after installation of radome to AESA radar were measured, and the beam pattern was analyzed through conversion to far field-after near-field measurement.The boresight error of the radar antenna device was measured, and it was confirmed that the main lobes were formed the same before and after the simulated radar dome was mounted.

A Study on the Necessity of Verification and Certification System of Inspection and Diagnostic Equipment for Infrastructure using Advanced Technologies (첨단 시설물 점검 및 진단장비 검·인증제도 도입 필요성에 대한 연구)

  • Hong, Sung-Ho;Kim, Jung-Gon;Cho, Jae-Young;Kim, Twae-Hwan
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.163-177
    • /
    • 2020
  • Purpose: While it is very important to maintain facilities recently, the introduction and its application of high technology in the facility maintenance industry has increased. It is necessary for high technology to secure reliability through the verification and certification system of diagnostic equipment to have an effective impact in the field, but there is difference between the industry's perspective and realistic level of technology apart from social demand for the system of the system. This paper dealt with the introduction of a verification and certification system for rational facility diagnostic equipment with the opinion survey on managers about the current situation. Method: Survey is carried out targeting managers in the maintenance and construction regarding the necessity and urgency of introducing a verification and certification system to promote the introduction and its application of high technology of diagnostic equipment and facility inspection. Also, the introduction to a verification and certification system was reviewed for advanced facility diagnostic equipment through foreign research about similar systems and comparative analysis of similar systems related to the certification of 21 domestic equipment. Result: It showed that, regarding the application of high technology, it is necessary for most managers to introduce high technology such as drones, robots, etc., in the maintenance industry, and when high technology is introduced, it will have a considerable effect in the field. On the other hand, the current technology level in Korea is relatively low, so it turned out to take a certain amount of time for the application of technology. Also, it was found that the management of reliable facility diagnostic equipment will be possible through the introduction of the verification and certification system for facility diagnosis equipment. Meanwhile, the survey is conducted on similar systems about foreign and domestic diagnosis and measuring equipment, etc., but there is no system to verify and certify equipment applied with high technology directly to facility diagnosis maintenance. However, because Japan has a system of verifying the performance of diagnostic equipment and South Korea has 21 similar inspection and diagnostic equipment certification systems among 186 certification systems, it is considered to be possible to design systems which utilize them. Conclusion: According to the managers' opinion, it seems that the introduction of the system supporting the application of 4th industrial technology for the equipment and the use of the equipment with high reliability has sufficient validity. However, because our high technology level is undervalued compared to the urgency, the system for checking high technology facilities and certifying diagnostic equipment should be to be implemented in form of escalation considering technical use and verification level. Apart from the introduction of the verification and certification system, it is necessary for special investment, support and efforts to promote advanced facility diagnostic equipment.

In-vivo Dose verification using MOSFET dosimeter (MOSFET 선량계를 이용한 In-vivo 선량의 확인)

  • Kang, Dae-Gyu;Lee, Kwang-Man
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.102-105
    • /
    • 2006
  • In-vivo dosimetry is an essential tool of quality assurance programs in radiotherapy. The most commonly used techniques to verify dose are thermoluminescence dosimeter (TLD) and diode detectors. Metal oxide semiconductor field-effect transistor (MOSFET) has been recently proposed for using in radiation therapy with many advantages. The reproducibility, linearity, isotropy, dose rate dependence of the MOSFET dosimeter were studied and its availability was verified. Consequently the results can be used to improve therapeutic planning procedure and minimize treatment errors in radiotherapy.

Analytical Prediction and Experimental Verification of Electromagnetic Performance of a Surface-Mounted Permanent Magnet Motor having a Fractional Slot/Pole Number Combination

  • Hong, Sang-A;Choi, Jang-Young;Jang, Seok-Myeong
    • Journal of Magnetics
    • /
    • v.19 no.1
    • /
    • pp.84-89
    • /
    • 2014
  • This paper presents an analytical prediction and experimental verification of the electromagnetic performance of a parallel magnetized surface-mounted permanent magnet (SPM) motor having a fractional number of slots per pole combination. On the basis of a two-dimensional (2-D) polar coordinate system and a magnetic vector potential, analytical solutions for flux density produced by the permanent magnets (PMs) and stator windings are derived. Then, analytical solutions for back-electromotive force (emf) and electromagnetic torque are derived from these field solutions. The analytical results are thoroughly validated with 2-D nonlinear finite element (FE) analysis results. Finally, the experimental back-emf and electromagnetic torque measurements are presented to test the validity of the analysis.

The Effects of the Methods of Disguised Voice on the Aural Decision (위장 발화 방법의 차이가 청취 판단에 미치는 영향)

  • Song Min-Chang;Shin Jiyoung;Kang SunMee
    • MALSORI
    • /
    • no.46
    • /
    • pp.25-35
    • /
    • 2003
  • This study deals with the disguised voice (or voice disguise) in the field of forensic phonetics. We especially studied the effects of the methods of disguised voice on the aural decision. Within the nonelectronic-deliberate voice disguise area, the methods of disguised voice include use of lowered pitch, pinched nostrils, falsetto, and whisper. Ten (male:5, female:5) Seoul speakers made a recording of 16 sentences. In the aural test, 30 subjects listened normal and disguised voice. And they were asked to make a decision whether speakers identified or not. The result is as follows: The speaker verification of the falsetto and whisper was more difficult than the lowered pitch and pinched nostrils.

  • PDF

Performance Verification of FRP Decks by Connection between Bridge Rail and FRP Decks (방호울타리 연결방법에 의한 FRP바닥판의 거동특성)

  • Lee, Young-Ho;Jeong, Jin-Woo;Youm, Kwang-Soo;Park, Ki-Tae;Hwang, Yoon-Koog
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.134-137
    • /
    • 2006
  • In this paper, performance verification of connection between bridge rail and FRP decks are performed by static test. Also, the effect of flexible bridge rail failure to behavior of FRP deck are examined. Commercial products of flexible bridge rail are applied to test specimen, and 6 types of FRP deck-to-bridge rail connection system are considered. By the test results, 6 types of connection system by the connection method have similar structural capacity and have enough safety margin. Therefore, it is determined that 6 kinds of bridge rail considered in this study can be applied to bridge effectively by the cases of bridge field condition.

  • PDF

The Design of Cable Damper System far Jindo Bridge and its Field Verification Test (진도대교 케이블 댐퍼시스템 설계 및 검증실험)

  • Seo, Ju-Won;Kim, Nam-Sik;Ahn, Sang-Sup;Jeong, Woon
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.09a
    • /
    • pp.302-310
    • /
    • 2001
  • In order to lessen cable vibration, new cable damper system with high damping rubber was developed using the basis of the LRB design scheme. The analysis model of cable damper system incorporate voigt-kelvin damper model into the nonlinear cable analysis model. To achieve maximum damping capacity both reducing damper stiffness and developing high damping rubber were performed. As a result of verification test, the high damping rubber damper shows its effectiveness in improving cable damping capacity.

  • PDF