• Title/Summary/Keyword: field size

Search Result 4,967, Processing Time 0.032 seconds

A Study on Sample Size Dependence of Ferromagnetic Resonance in Polycrystalline Magnesium Ferrites (마그네슘 페라이트에서 강자성 공명의 시료 크기 의존성 연구)

  • 한기태;백종규
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.2
    • /
    • pp.163-170
    • /
    • 1995
  • Sample size effect on ferromagnetic resonance (FMR) in polycrystalline MgFe2O4 has been investigated. The signal intensity (SI), resonance field (Hres) and line width (ΔH) were found to increase proportionally to r3 with the increase of sample radius. The r3-depencence of SI means the complete penetration of rf-field into the sample, and the broadening of ΔH due to the sample size appears to be closely related to the amount of scattering sources like pores. Meanwhile, the values of Hres (0) and ΔH (0) obtained by extrapolating the data of Hres (r) and ΔH (r) measured at several sizes to r=0, were in good agreement with those calculated using the Schlomann's equations for internal field and ΔH, respectively. This result indicates that the discrepancy between the measured FMR parameters and those calculated by Schlomann's equation could be ascribed to the effect of sample size. Thus it is suggested that the size effect on FMR should be removed for the analysis of the FMR parameters. Meanwhile, our result for the size dependance of ΔH was found to be contradictory to those reported by Dionne, where ΔH 1/r at a given surface roughness. This discrepancy appears to arise from the difference in the definition of reading the line width.

  • PDF

Effect of Inlet Geometry on Fan Performance and Inlet Flow Fields in a Semi-opened Axial Fan

  • Liu, Pin;Shiomi, Norimasa;Kinoue, Yoichi;Setoguchi, Toshiaki;Jin, Ying-Zi
    • International Journal of Fluid Machinery and Systems
    • /
    • v.7 no.2
    • /
    • pp.60-67
    • /
    • 2014
  • In order to clarify the effect of inlet bellmouth size of semi-opened type axial fan on its performance and flow fields around rotor, fan test and flow field measurements using hotwire anemometer were carried out for 6 kinds of bellmouth size. As results of fan test, the shaft power curve hardly changed, even if the bellmouth size changed. On the other hand, the pressure-rise near best efficiency point became small with the bellmouth size decreasing. Therefore, the value of maximum efficiency became small as the bellmouth size decreased. As results of flow field measurements at fan inlet, the main flow region with large meridional velocity existed near blade tip when the bellmouth size was large. As bellmouth size became smaller, the meridional velocity at fan inlet became smaller and the one at outside of blade tip became larger. As results of flow field measurements at fan outlet, the main flow region existed near rotor hub side.

A Survey on the Research Trends of Clothing Construction in Korea - Focused on Journal Publications from 2001 through 2010 - (한국 의복구성학 분야의 연구동향 - 2001~2010년까지 학회지를 중심으로 -)

  • Choi, Hae-Joo
    • Journal of the Korean Society of Costume
    • /
    • v.63 no.3
    • /
    • pp.138-150
    • /
    • 2013
  • The purpose of this study was to investigate research trends of subject matter in clothing construction field in clothing and textiles and to suggest the information for the future directions for fashion business and research. 2737 articles with clothing and textiles subject matter, 350 articles with clothing construction field in the Journal of Korean Society of Costume and Journal of the Korean Society of Clothing and Textiles from 2001 through 2010 were analyzed. The major conclusions of the study are as follows: 1. Clothing construction field took 12.8% with 350 articles in the researches of the Journal Publications in 2000s. 2. Clothing construction field showed more proportions in the latter half of the decade. 3. Clothing construction field were classified into 5 topics : topic of basic pattern and pattern for apparel, topic of body types, topic of functionality of clothing and protective clothing, topic of size system of apparel, topic of sewing and manufacturing process. 4. In clothing construction field, topic of basic pattern and pattern for apparel took the most proportions. 5. Topic of body types, topic of functionality of clothing and protective clothing, topic of size system of apparel, topic of sewing and manufacturing process were followed.

Wedge Factors in Various Field Sizes (조사야의 크기에 따른 쐐기 인자)

  • 조철우
    • Progress in Medical Physics
    • /
    • v.6 no.2
    • /
    • pp.29-34
    • /
    • 1995
  • The wedge factor is defined as a ratio of the absorbed dose in a phantom at a depth of reference point on the central axis with the wedge in the place to the absorbed dose at the same point with the wedge removed. We attempted to show the wedge factors dependence on the field sizes. The wedge factors were measured at various field sizes on 6MV and 15MV x-ray of Varian Clinac 1800 and 5MV x-ray of Philips SL75/5. The single wedge factor measured for a reference field size(10cmx10cm) may not be valid for all field sizes. For the thick wedge, especially an autowedge on Philips SL75/5 for maximum field size width 30cm. the error can be significant(6.6%). Therefore, in the presence of a wedge filter in the beam, a field size dependent wedge factor may be necessary in the treatment dose calculations.

  • PDF

Determination of In-focus Criteria In Image Processing Method for Particle Size Measurement (입경측정을 위한 영상처리기법에서 입자 초점면 존재 판단 기준의 설정)

  • Koh, Kwang Uoong;Kim, Joo Youn;Lee, Sang Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.3
    • /
    • pp.398-407
    • /
    • 1999
  • In the present image processing technique, the concept of the gradient indicator(GI) has been introduced to find out the depth-of-field in sizing large particles ranging from $30{\mu}m$ to $30{\mu}m$ where using of the concept of the normalized contrast value(VC) is not appropriate. The gradient indicator is defined as the ratio of the local value to the maximum possible value of the gray-level gradient in an image frame. The gradient indicator decreases with the increases of the particle size and the distance from the exact focal plane. A particle is considered to be in focus when the value of the gradient indicator at its image boundary stays above a critical value. This critical gradient indicator($GI_{critical}$) is defined as the maximum gradient indicator($GI_{max}$) subtracted by a constant ${\Delta}GI$ which is to account for the particle-size effect. In the present ca.so, the value of ${\Delta}GI$ was set to 0.28 to keep the standard deviation of the measured particles mostly within 0.1. It was also confirmed that, to find the depth-of-field for small particles(${\leq}30{\mu}m$) with the same measurement accuracy, tho concept of the critical normalized contrast($VC_{critical}$) is applicable with 85% of the maximum normalized contrast value($VC_{max}$). Finally, the depth-of-field was checked for the size range between $10{\mu}m$ and $300{\mu}m$ when the both in-focus criteria ($GI_{critical}$ and $VC_{critical}$) were adopted. The change of the depth-of-field with the particle size shows good linearity in both the VC-applicable and the GI-applicable ranges with a reasonable accuracy.

Study on the beam properties of small field sizes (소조사면 전량분포의 특성에 관한 고찰)

  • Cho JeongHee;Lee SangKyu;An SeungKwon;Park Jell
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.1-9
    • /
    • 2004
  • Purpose : The aim of this study is to investigate the properties of small field size and to measure the penumbra and central axis depth dose varying to the jaw setting and off axis distance for indicate this data to small field sizes radiation therapy. Material and methods : The percentage depth dose, beam profile and central axis output dose was measured by farmer type ion chamber and pinpoint chamber using Primart linac with 6MV energy. Beam quality and penumbra variations according to the central axis shift, from center to every 2cm outside increment, and field size, from $1{\times}1cm$ to $10{\times}10cm$ was investigated and compared with that of the standard geometrical condition's results Results : The differences of measured values between two ion chamber was about $37\%$ at 10cm depth with $1{\times}1cm$ field sizes but as field size increased this differences was diminished gradually. Measured data from various off axis distance with the different asymmetric collimations are not changed significantly but as size decreased the dose variation was increased and at $1{\times}1cm$ field size dose difference among off axis distance was as much as $13\%$, and as shallower the measured depth the central axis dose variations among the OAD was increased, penumbra was not changed noticeably depending on off axis distance but the percentage of penumbra from its initial field sizes was strongly dependant on field sizes and penumbra occupation rates of its own field sizes ranging from $6\%$ at $10{\times}10cm$ to $50\%$ at $1{\times}1cm$ field size. Conclusion : For imrt treatment, there are several numbers of different gentry angles with beams of nonuniform fluences are required and several complex factors involved. Among them the characteristics of beam output varying to the geometrical setting and design of collimators are of important to attaining a good treatment results. As mentioned in results the differences of measured values are changed significantly depends on ion chamber volume, depths and field size. For providing quality radiation treatment, especially at small field size, those factor's should have considering deliberately.

  • PDF

A Study on the Automatic Inspection System using Invariant Moments Algorithm with the Change of Size and Rotation (크기와 회전 변화에 불변 모멘트 알고리즘을 이용한 자동 검사 시스템에 관한 연구)

  • Lee, Yong-Joong
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.3
    • /
    • pp.37-43
    • /
    • 2004
  • The purpose of this study is to develop a practical image inspection system that could recognize it correctly, endowing flexibility to the productive field, although the same object for work will be changed in the size and rotated. In this experiment, it selected a fighter, rotating the direction from $30^{\circ}$ to $45^{\circ}$ simultaneously while changing the size from 1/4 to 1/16, as an object inspection without using another hardware for exclusive image processing. The invariant moments, Hu has suggested, was used as feature vector moment descriptor. As a result of the experiment, the image inspection system developed from this research was operated in real-time regardless of the chance of size and rotation for the object inspection, and it maintained the correspondent rates steadily above from 94% to 96%. Accordingly, it is considered as the flexibility can be considerably endowed to the factory automation when the image inspection system developed from this research is applied to the productive field.

Pentacene Thin-Film Transistors with Polyimide/$SiO_2$ Dual Gate Dielectric

  • Imahara, Hirokazu;Kim, Woo-Yeol;Oana, Yasuhisa;Majima, Yutaka
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.972-973
    • /
    • 2007
  • Relationships between field effect mobility and grain size on pentacene thin-film transistors with $polyimide/SiO_2$ gate dielectrics have been studied. 6 kinds of polyimide were used as surface treatment gate dielectric layer. Grain size of the pentacene thin film were between 5 and $30\;{\mu}m$ and depended on the polyimide. The field effect mobility were also depended on the polyimide and the those values were from 0.027 to $0.69\;cm^2/(Vs)$. The field effect mobility tends to increase with increasing the grain size. Precursor type polyimide containing polyamic acid show better mobility of $0.69\;cm^2/(Vs)$ than soluble type polyimide. Bias stress characteristics in air are discussed in the basis of the grain size.

  • PDF

The Optimal Condition for Scanning Large Area with a Micro-electron-column (초소형 전자칼럼의 대면적 주사 적정조건)

  • Park, Sung-Soon;Kim, Ho-Seob;Jang, Won-Kweon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.6
    • /
    • pp.481-486
    • /
    • 2007
  • In large area scanning with a micro-electron-column, the operating condition for the best resolution was investigated in factors of working distance and field of view. The resolution of a test sample was dependent on electron beam energy and scanning field size. The best resolution with single deflector was obtained at 300 V and 30 mm in the electron emitting tip voltage and a working distance, respectively. The scanning area at that condition was $13.9{\times}13.9mm^2$, linearly increased with the working distance. Double deflector was employed for larger scanning size without increasing working distance, but showed only 1.7 times larger than that of single deflector, and the resolution was inverse proportional to the scanning size.

A Basic Study on Developing an Electrocharged Scrubber (전기하전식 세정집진장치 개발에 관한 기초 연구)

  • 김종호
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.1
    • /
    • pp.33-39
    • /
    • 1999
  • This study has been performed to develop an efficient electrocharged scrubber. To improve collection efficiency of the scrubber, electric-charger was installed at the forefront of the packed crossflow scrubbers, and an experiment of changing discharge electrode shape and fluctuating electric field strength was undertaken. After using a light-oil boiler for generation of particles in the about 80% weight of submicron size particles was exhausted. Collection characteristics of the electrocharged scrubber were similar to those of two-stage electrostatic precipitator. In this study the collection efficiency of submicron size particles has been much improved, compared with the previous ones. In an experiment of changing discharge electrode and electric field strength, a needle-spike shape wire electrode showed a higher collection efficiency than round shape wire. The collection efficiency becomes increased with an increase of electric field strength.

  • PDF