• 제목/요약/키워드: field resistance

검색결과 2,408건 처리시간 0.026초

A LSTM-based method for intelligent prediction on mechanical response of precast nodular piles

  • Chen, Xiao-Xiao;Zhan, Chang-Sheng;Lu, Sheng-Liang
    • Smart Structures and Systems
    • /
    • 제30권2호
    • /
    • pp.209-219
    • /
    • 2022
  • The determination for bearing capacity of precast nodular piles is conventionally time-consuming and high-cost by using numerous experiments and empirical methods. This study proposes an intelligent method to evaluate the bearing capacity and shaft resistance of the nodular piles with high efficiency based on long short-term memory (LSTM) approach. A series of field tests are first designed to measure the axial force, shaft resistance and displacement of the combined nodular piles under different loadings, in comparison with the single pre-stressed high-strength concrete piles. The test results confirm that the combined nodular piles could provide larger ultimate bearing capacity (more than 100%) than the single pre-stressed high-strength concrete piles. Both the LSTM-based method and empirical methods are used to calculate the shift resistance of the combined nodular piles. The results show that the LSTM-based method has a high-precision estimation on shaft resistance, not only for the ultimate load but also for the working load.

초고강도 내화 콘크리트의 현장 적용을 위한 내화성능 평가에 관한 연구 (A Study on Fire Resistance Performance Evaluation for Field Application of Ultra-High Strength Concrete)

  • 백영운;육태원;박동수;김한솔;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.41-42
    • /
    • 2023
  • The physical performance of high-strength concrete deteriorates when exposed to high temperatures such as fire. In particular, in the case of ultra-high-strength concrete, there is a high possibility of explosion due to internal water pressure and thermal expansion due to the tight internal structure. In this paper, a fire resistance certification test was conducted for field application of ultra-high-strength fire-resistant concrete, and the fire resistance performance (temperature rise of main rebar) was compared according to the structural concrete cover thickness. As a result, when the covering thickness was 40 mm, three structures did not meet the certification standards, and when the covering thickness was 50 mm, all structures met the fire resistance certification standards.

  • PDF

모래지반에서 쐐기모델을 이용한 단말뚝의 극한수평저항력 산정 (Evaluation of Ultimate Lateral Resistance for Single Pile Using Strain Wedge Model in Sand)

  • 김지성;강기천
    • 한국지반공학회논문집
    • /
    • 제32권12호
    • /
    • pp.15-22
    • /
    • 2016
  • 본 연구에서는 Strain wedge 해석모델을 이용하여 수평하중이 작용하는 단말뚝의 극한수평저항력 산정식을 제안하였다. 저항특성은 쐐기 후면부의 수평저항토압, 쐐기 측면부의 전단저항, 그리고 말뚝과 지반의 마찰저항으로 구분하였고, 이들의 합으로써 극한수평저항력을 산정하였다. 제안된 식을 기존의 쐐기 이론과 현장실험, 유한차분법과비교 분석하였다. 그 결과 제안식의 값이 기존의 쐐기 이론과 1.03%, 현장실험과는 0.40~3.32%, 유한차분법과는 6.02%의 차이를 보였다.

암반에 근입된 현장타설말뚝의 주면지지력 (Side Shear Resistance of Drilled Shafts in Rock)

  • 권오성;김병철;김명모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.611-618
    • /
    • 2005
  • In this research, the effect of rock mass weathering on the side shear resistance of drilled shaft socketed into weathered rock was investigated. For that, a database of 23 cast-in-place concrete piles with diameters varying from 400mm to 1,500mm were socketed into weathered igneous/meta-igneous rock at four different sites. The static axial load tests were performed to examine the resistant behavior of the piles, and a comprehensive field/laboratory testing program at the field test site was also performed to describe the in situ rock mass conditions quantitatively. No correlation was found between the compressive strengths of intact rock and the side shear resistance of weathered/soft rock. The ground investigation data regarding the rock mass conditions (e.g. $E_m,\;E_{ur},\;_{plm}$, RMR, RQD, j) was found to be highly correlated with the side shear resistance, showing the coefficients of correlation greater than 0.7 in most cases. Additionally, the applicability of existing methods for the side shear resistance of piles in rock was verified by comparison with the field test data. The existing empirical relations between the compressive strength of intact rock and the side shear resistance(Horvath (1982), Rowe & Armitage(1987) etc.) appeared to overestimated the side shear resistance of all piles tested in this research unless additional consideration on the effect of rock mass weathering or fracturing was applied. The existing methods which consider the effect of rock mass condition were modified and/or extended for weathered rock mass where mass factor j is lower than 0.1, and RQD is below 50%.

  • PDF

Characteristics of P-channel SOI LDMOS Transistor with Tapered Field Oxides

  • Kim, Jong-Dae;Kim, Sang-Gi;Roh, Tae-Moon;Park, Hoon-Soo;Koo, Jin-Gun;Kim, Dae-Yong
    • ETRI Journal
    • /
    • 제21권3호
    • /
    • pp.22-28
    • /
    • 1999
  • A new tapered TEOS oxide technique has been developed to use field oxide of the power integrated circuits. It provides better uniformity of less than 3 % and reproducibility. On-resistance of P-channel RESURE (REduced SURface Field) LDMOS transistors has been optimized and improved by using a novel simulation and tapered TEOS field oxide on the drift region of the devices. With the similar breakdown voltage, at $V_{gs}$=-0.5V, the specific on-resistance of the LDMOS with the tapered field oxide is about $31.5{\Omega}{\cdot}cm^2$, while that of the LDMOS with the conventional field oxide is about $57m{\Omega}{\cdot}cm^2$.

  • PDF

외부자장에 의한 초전도체의 전기적 특성 변화 기구 (Effects of Applied Magnetic Field on the Electrical Properties of High Tc Superconductor)

  • 이상헌
    • 한국분말재료학회지
    • /
    • 제13권3호
    • /
    • pp.217-222
    • /
    • 2006
  • The relationship between electrical properties of superconductor and externally applied magnetic field was studied to develop a magnetic field sensor. The electrical resistance of the superconductor was increased by applying external magnetic field and even after removal of the magnetic field. This behavior was related to the magnetic flux trapped in the superconductor, which penetrated through the material by the external magnetic field. Some portion of the superconductor was changed to a normal state by the trapped magnetic flux. The appearance of the normal state yielded to enhance the electrical resistance.

경사진 Field Plate을 갖는 SOI LDMOS에 관한 연구 (A Study on the SOI LDMOS with a Tapered Field Plate)

  • 나종민;최연익
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.367-369
    • /
    • 1995
  • An SOI LDMOS(Silicon-On-Insulator Lateral Double diffused MOSPET) with a tapered field plate is proposed and investigated in terms of the breakdown voltage and on-resistance using 2-D simulator, MEDICI. The results of conventional SOI LDMOS with a stepped field plate are reported for the comparison. Simulated breakdown voltage of the proposed LDMOS is found to be higher than that of conventional LDMOS since surface electric field can be reduced due to the field plate over the tapered oxide. On-resistance of proposed LDMOS is found to be lower than that of conventional LDMOS by 10%.

  • PDF

QTLs Identification and Confiirmation of Field Resistance to Leaf Blast in Temperate japonica Rice (Oryza sativa L.)

  • Cho, Young-Chan;Kwon, Soon-Wook;Suh, Jung-Pil;Kim, Jeong-Ju;Lee, Jeom-Ho;Roh, Jae-Hwan;Oh, Myung-Kyu;Kim, Myeong-Ki;Ahn, Sang-Nag;Koh, Hee-Jong;Yang, Sae-Jun;Kim, Yeon-Gyu
    • Journal of Crop Science and Biotechnology
    • /
    • 제11권4호
    • /
    • pp.269-276
    • /
    • 2008
  • Field resistance is defined as the resistance that allows effective control of a parasite under natural field condition and is durable when exposed to new races of that parasite. To identify the genes for field resistance to rice blast, quantitative trait loci (QTLs) conferring the resistance for races and blast nursery screening in japonica rice cultivars were detected and mapped using SSR markers. QTL analysis was carried out in 190 RILs population from the cross between Suweon365 (moderately resistant) and Chucheong (highly susceptible). Twelve QTLs against nine blast races inoculated were detected on chromosomes 1, 2, 4, 6, 7, 11 and 12. They explained from 5.1% to 34.9% of total phenotypic variation. Eight QTLs against blast nursery screening in four regions for three years were detected on chromosomes 1, 2, 4, 11 and 12. The phenotypic variation explained by each QTL ranged from 4.3% to 37.7%. Three chromosome segment substitution lines (CSSLs) of $BC_2F_6$ by backcross method were developed to transfer the QTLs into the susceptible cultivar Chucheong as a recurrent parent. A CSSL4-1 containing two QTLs qLB6.2 and qLB7 against blast races showed to the reaction of 6 to 7 at blast nursery in two regions for two years. The CSSL4-2 and CSSL93 containing QTLs, qLB11.2 and qLB12.1 of the resistance against leaf blast in blast nursery screening, respectively, had enhanced the resistance for blast nursery screening across two regions and in two years.

  • PDF

근접장 마이크로파 현미경을 이용한 ITO 박막 면저항의 비파괴 관측 특성 연구 (Nondestructive measurement of sheet resistance of indium tin oxide(ITO) thin films by using a near-field scanning microwave microscope)

  • 윤순일;나승욱;윤영운;유현준;이영주;김현정;이기진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.522-525
    • /
    • 2004
  • ITO thin films $({\sim}150\;nm)$ are deposited on glass substrates by different deposition condition. The sheet resistance of ITO thin films measured by using a four probe station. The microstructure of these films is determined using a X-ray diffractometer (XRD) and a scanning electron microscope (SEM) and a atomic force microscope (AFM). The sheet resistance of ITO thin films compared $s_{11}$ values by using a near field scanning microwave microscope.

  • PDF

고온초전도 선재의 접합 및 인덱스손실 평가 (Estimation of joint and index dissipation in HTS tape)

  • 김정호;임준형;장석헌;김규태;주진호;최세용;나완수;강형구;고태국
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.59-62
    • /
    • 2003
  • We fabricated two HTS closed coils by using resistive-joint method and the joint resistance of the coil was estimated by field decay technique at 77 K. In addition, we used the Runge-kutta method for the numerical analysis to estimate the decay properties. The joint resistances were evaluated as a function of critical current of HTS closed coil and external field strength of excitation coil. It was observed that joint resistance was independent of critical current and external field strength. It was estimated that joint resistance was 8.0$\times$10$^{-9}$ $\Omega$ to 11.9$\times$10$^{-9}$ $\Omega$ for coils of contact length for 7 cm.

  • PDF