• Title/Summary/Keyword: field load test

Search Result 883, Processing Time 0.024 seconds

The Study on Affecting Subject Accomplishment by Noise (소음이 과제수행에 미치는 영향에 관한 연구)

  • Kim, Sung-Cheol;Park, Keun-Sang;Kim, Kwan-Woo
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.1
    • /
    • pp.121-128
    • /
    • 2010
  • The purpose of this study is to confirm the impact of noise on subject accomplishment as well as physical/mental load, and evaluates the effects of noise-masking and earplug. 15 college students participate in the test, and the comparison is performed by executing four projects according to conditional categories of noise environments; control condition, noise condition, earplug condition, and noise-masking condition. Noise in the field site of the H manufacturer was used as the noise source, the general job aptitude test which consist of linguistic ability, math ability, perception ability, reasoning ability was used as the task of this project. To estimate physical/mental load evaluation, we used the heart rate R-R interval, Criteria flicker fusion frequency(CFF) and measured NASA-TLX workload for subjective evaluation. As the research outcome, it is shown that there is a meaningful difference for the project task score, dropping rate of CFF, the heart rate, and NASA-TLX subjective evaluation score according to conditions of noise environment. Therefore, the impact of noise on capability of subject accomplishment as well as physical/mental load was confirmed along with the effects of using earplug and noise-masking.

A Mock Running And Transient State Test of Propulsion VVVF Inverter for Electric Locomotive using A Inertia Load (관성부하를 이용한 전동차 추진용 VVVF 인버터의 모의주행 및 과도상태시험)

  • 정만규;서광덕
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.6
    • /
    • pp.491-499
    • /
    • 1999
  • This paper is on the high perfonnance propulsion IGBT VVVF inverter adopted new technique for railways. To prove the high performance and stabilit~r of traction, running tests are carried out under the simulated condition alike real field. The tests are perfonned on not only a steady states but also a transient states such a as input voltage variation using inertia load equivalent to 160tons train. The vector control technique is a adopted to improve traction for 4 motors. The low switching synchronous PW1\l method based on a space v voltage vector modulation is pro\XlSed as the optimal method for propulsion system railway. The output voltage l is controlled continuously to six step by prolxlsed ovennodu]ation technique without sudden torque variation.

  • PDF

On the post-buckling behaviour of plates under stress gradient

  • Bedair, Osama K.
    • Structural Engineering and Mechanics
    • /
    • v.4 no.4
    • /
    • pp.397-413
    • /
    • 1996
  • In this paper the elastic post-buckling behaviour of plates under non-uniform compressive edge stress is investigated. The compatibility differential equations is first solved analytically and then an approximate solution of the equilibrium equation is obtained using the Galerkin method. Explicit expressions are derived for the load-deflection, ultimate strength and membrane stress distributions. Analytical effective width formulations, based on the characteristics of the stress field of the buckled plate, are proposed for this general loading condition. The predicted load-deflection expression is compared with independent test results. Results are also presented detailing the load-deflection behaviour and stress distribution for various aspect ratios.

Load Transfer on Pulsed Power Discharge Anchors (펄스방전 확공형 앵커의 하중전이에 관한 연구)

  • Kim, Sung-Kyu;Kim, Nak-Kyung;Kim, Jae-Won;Joo, Yong-Sun;Kim, Sun-Ju
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.832-839
    • /
    • 2010
  • The pulse discharge anchor is a method to increase the capacity of anchors using electric discharge geotechnical technologies, which is also known as pulse discharge and electric-spark technologies. The pulse discharge anchor has bulbed bond length that is expanded by high voltage electrokinetic pulse energy. 24 anchors were installed in the weathered soil and sandy clay at the Geotechnical Experimentation Site at Sungkyunkwan University in Suwon, Korea and attached strain gauge at 10 anchors. The numerical predictions by Beam-Column analysis were compared with observed measurements in a field load test.

  • PDF

The development of microprocessor_based controller for the electrical boiler of heat storage type (축열식 전기보일러용 마이크로프로세서 제어장치개발)

  • Kim, J.S.;Park, J.W.;Joe, K.Y.;Kim, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.250-253
    • /
    • 1989
  • As the necessity of increasing the midnight base load is extensively increased, electric power companies have to increase the demand of midnight electrical power by lowering the electrical charge rate at midnight. One of the most widely used midnight equipments is the heat Storage type's electrical boiler. A Single chip microprocessor controller for the heat-storage type's electrical boiler is developed. This controller call reduce the undesirable peak load at the begining of midnight (i.e.11 P.M.) time band by using backward load control method. Futhermore, this controller enables reservation of heat storge and the effective heating control the field test has been done by use the boiler for 66$m^2$ with the heater of 21KW quality.

  • PDF

Application of operating vehicle load to structural health monitoring of bridges

  • Rafiquzzaman, A.K.M.;Yokoyama, Koichi
    • Smart Structures and Systems
    • /
    • v.2 no.3
    • /
    • pp.275-293
    • /
    • 2006
  • For health monitoring purpose usually the structure is instrumented with a large scale and multichannel measurement system. In case of highway bridges, operating vehicle could be utilized to reduce the number of measuring devices. First this paper presents a static damage detection algorithm of using operating vehicle load. The technique has been validated by finite element simulation and simple laboratory test. Next the paper presents an approach of using this technique to field application. Here operating vehicle load data has been used by instrumenting the bridge at single location. This approach gives an upper hand to other sophisticated global damage detection methods since it has the potential of reducing the measuring points and devices. It also avoids the application of artificial loading and interruption of any traffic flow.

A Comparative Analysis of Sea Ice Material Properties in the Amundsen Sea, Antarctica (남극 아문젠해에서 계측된 해빙의 재료특성 비교 분석)

  • Choi, Kyungsik;Kim, Hyun Soo;Ha, Jung Seok;Lee, Chun-Ju
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.51 no.3
    • /
    • pp.254-258
    • /
    • 2014
  • Field trial in ice-covered sea is one of the most important tasks in the design of icebreaking ships. To correctly estimate ice load and ice resistance on ship's hull, It is essential to understand the material properties of sea ice during ice field trials and to perform the proper experimental procedure by gathering sea ice data. A measurement of sea ice properties was conducted during February and March of 2012 with the Korean Icebreaking research vessel "ARAON" in the Amundsen Sea, Antarctica. This paper describes a test procedure to obtain sea ice data which provide basic information to estimate ice loads and icebreaking performance of the ship. The data gathered from sea ice field trials during the 2012 Antarctic voyage of the ARAON includes ice temperature/salinity/density and the compressive/flexural strength of sea ice. This paper analyses the gathered Antarctic sea ice material properties comparing with the previous data obtained during ARAON's Arctic and Antarctic voyages in 2010.

Study on the Applicability of Dynamic Pile Load Test to Check Integrity during Installation of Extension Plate Attached PHC Piles and Bolts Spliced PHC Piles and the Correct Proof Test of the Transformed-installation PHC Piles (확장판 선단부착 PHC말뚝 및 볼트 수직이음을 사용한 PHC말뚝의 시공 중 건전성 확인을 위한 동재하시험의 적용성 및 변형시공법 PHC말뚝들의 올바른 검증시험에 관한 연구)

  • Kim, Myunghak;Choi, Yongkyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.12
    • /
    • pp.115-131
    • /
    • 2018
  • Extension plate attached PHC piles and bolts spliced PHC piles were installed in field test site. Pile integrities were checked during installation with dynamic pile test and the actual pile conditions after installation were compared with integrity index (${\beta}$ index) by PDA test. Theoretically the break in near pile end or pile end (especially extension plate itself) was very difficult to access by integrity index (${\beta}$ index) and also require a high level of knowledge and field experience on PDA test. First actual wave equation of bolts spliced PHC piles due to bolts spliced equipment can be different with welding spliced. Second wave length of the stress wave from installing can be longer than the height of bolts spliced equipment (about 100 mm). Third Beta processing in PDA analysis function is very difficult to access without a high level of knowledge and field experience on wave equation. Above-mentioned three reasons can make conclusion that traditional PDA test in domestic site can not access the integrity of bolts spliced equipment in bolts spliced PHC piles.

Experimental Study on the Structural Safety of the Tractor Front-End Loader Against Impact Load

  • Park, Young-Jun;Shim, Sung-Bo;Nam, Ju-Seok
    • Journal of Biosystems Engineering
    • /
    • v.41 no.3
    • /
    • pp.153-160
    • /
    • 2016
  • Purpose: This study was conducted to experimentally investigate the structural safety of and identify critical locations in a front-end loader under impact loads. Methods: Impact and static tests were conducted on a commonly used front-end loader mounted on a tractor. In the impact test, the bucket of the front-end loader with maximum live load was raised to its maximum lift height and was allowed to free fall to a height of 500 mm above the ground where it was stopped abruptly. For the static test, the bucket with maximum live load was raised and held at the maximum lift height, median height, and a height of 500 mm from the ground. Strain gages were attached at twenty-three main locations on the front-end loader, and the maximum stresses and strains were measured during respective impact and static tests. Results: Stresses and strains at the same location on the loader were higher in the impact test than in the static test, for most of measurement locations. This indicated that the front-end loader was put under a severe environment during impact loading. The safety factors for stresses were higher than 1.0 at all locations during impact and static tests. Conclusions: Since the lowest safety factor was higher than 1.0, the front-end loader was considered as structurally safe under impact loads. However, caution must be exercised at the locations having relatively low safety factors because failure may occur at these locations under high impact loads. These important design locations were identified to be the bucket link elements and the connection elements between the tractor frame and front-end loader. A robust design is required for these elements because of their high failure probability caused by excessive impact stress.

A study of Dielectric Strength of Spacer for Tap Changer in a $SF^6 $ Gas Insulated Transformer ($SF^6 $ 가스변압기의 탭절환기용 스페이서의 절연내력에 관한 연구)

  • Heo, U-Haeng;Ha, Yeong-Sik;Hong, Jeong-Gyun;Kim, Gyu-Tak
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.11
    • /
    • pp.556-562
    • /
    • 2001
  • Spacer is used between main tank and auxiliary tank for on load tap changer in gas insulated power transformer. This paper deals with electrical design of spacer and discusses different analysis method of between 2D FEM(finite element method) and 3D FEM. To design spacer, we modeled structure of two kind of coaxial cylinders of spacer conductors and analysised electric field of spacer at impulse and induced test voltage condition. Spacer has 13 conductors and electric field was changed according to arrangement of conductors. We could find out arrangement of conductors at which electric stress is minimum. And this arrangement was satisfied with actual test conditions.

  • PDF