• Title/Summary/Keyword: field load test

Search Result 880, Processing Time 0.032 seconds

Seismic Behavior of H shaped Beam to Square Column Connection with Outer Diaphragm Using Field Welding (외측 다이아프램을 사용한 현장 용접형 각형강관기둥-H형강보 접합부의 이력거동)

  • Seo, Seong Yeon;Jung, Jin Ahn;Choi, Sung Mo;Kim, Sung Young
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.4 s.77
    • /
    • pp.459-467
    • /
    • 2005
  • This study focuses on the development of a new method of H-shaped beam-to-square column connection with an outer diaphragm and a field welding. The specific type of beam-to-column connection with an external stiffener, using field welding, is proposed. The structural behavior of this connection was examined experimentally. Two loading type tests were conducted under the experimental parameters given as details. First described was the symmetrical loading test, which supported both ends or a beam simply and applied a load from the column to the pend (What does this mean?) to investigate a fundamental characteristic of this connection. Further described was the anti-symmetrical loading test, which carried out simple support of the column'stop end and the column base, and applied a load from both ends of a beam to investigate the structural performance of this connection. From the results, it is clear that the external- stiffener-type connection proposed in this paper is the reliable connection method.

A Study on the Safety Assessment of the Continuous Prestressed Concrete Beam Bridge (연속 프리스트레스트 콘크리트 빔교의 안전성 평가에 관한 연구)

  • 채원규
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1997.05a
    • /
    • pp.31-36
    • /
    • 1997
  • In this thesis, the safety assessment method of the continuous prestressed beam bridge using the service load were studied. From the field test results of the continuous prestressed beam bridge, CAE(composite action factor) and $P_{n}$(capacity load of bridge) were assessed, and these factors were applied to safety assessment of the continuous prestressed beam bridge.

  • PDF

Reliability Analysis of Auto-Connector in Use-condition (사용 조건하에서의 자동차용 커넥터 신뢰성 분석)

  • 김종걸;김진환
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2004.05a
    • /
    • pp.129-136
    • /
    • 2004
  • Environmental factors for automotive consist of temperature, humidity, vibration(sine & random), gas, an electrical load and so on. These environmental factors are impressed in a automotive. Dependability is essential requirement in many electronic parts. Among components of automotive, the connector connecting electrical signals is one of the most important parts. Automotive -connector is inspected according to each manufacturer's test standard in which dependability should be considered. This paper aims to verify that current test standard is suitable for dependability, and present an inductive life test for automotive connector based on the field data in use-condition.

  • PDF

Flaw Detection of the Aged Bridge on National Roadway by Impact Echo Testing (충격반향기법을 이용한 국도상 노후교량의 결함검사)

  • 유재열;김기봉;정영수;조성호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10b
    • /
    • pp.743-748
    • /
    • 1998
  • As nation's infrastructure is getting old, nondestructive evaluation of existing structures and construction quality control are getting important. In this thesis, flaw detection techniques of concrete members with asphalt using impact echo test were introduced. This techniques are based on stress wave propagation. In this field impact echo test, As load is gradually increased, frequency is increased. From this change of frequency through impact echo test, we can detect that the crack of bridge ascends and what the depth of crack is.

  • PDF

CHANCE OF MECHANICAL PROPERTIES IN NITINOL BY FATIGUE LOAD (피로하중에 의한 NITINOL의 기계적 성질의 변화)

  • Ha, Kook-Bong;Shon, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.23 no.4 s.43
    • /
    • pp.725-734
    • /
    • 1993
  • Nitinol wires are now widely used in the orthodontic field because of their unique shape memory effect and superelasticity. But sometimes Nitinol wires are deformed in clinical use. Fatigue load is possible cause of Nitinol deformation. To determine the effect of fatigue load to the mechanical properties of Nitinol, various fatigue cycle$(1\times10^4,\;2\times10^4,\;3\times10^4,\;4\times10^4,\;5\times10^4,\;1\times10^5)$ were applied to $0.017\times0.025$ inch Nitinol. The results obtained were as follows ; 1. Applied load increased as fatigue cycle increased in three point bending test. 2. Maximum tensile strength and elongation decreased as fatigue cycle increased. 3. Tn SEM, brittle fracture pattern was increased when fatigue cycle increased.

  • PDF

Study on LSDC Design for Coiling Shape Control of Hot Strip Mills (열간압연 권취형상 제어를 위한 LSDC 설계에 관한 연구)

  • Lee, Sang Ho;Park, Hong Bae;Park, Cheol Jae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.9
    • /
    • pp.869-874
    • /
    • 2015
  • We developed an LSDC (Load Shift and Load Distribution Control) technology in order to improve coil quality and productivity by reducing tension fluctuation especially for the tail of the strip in the down coiler in hot strip mills. To adapt the new controller, the torque and speed distribution between the zero pinch roll, pinch roll, and mandrel are needed. The proposed controller is a combination of an LSC to share the tension between the mill stand and the mandrel, and an LDC to shift the torque load from the zero pinch roll to the pinch roll. From the simulation, the proposed controller is verified under the torque disturbance. Using a field test, the torque deviation decreased by nearly 50% through utilization of the LSDC control.

Behaviour of Ground Anchor According to Period Characteristic of Seismic Load Using Numerical Analysis (수치해석을 통한 지진하중의 주기특성에 따른 그라운드 앵커의 거동)

  • Oh, Dong-Wook;Jung, Hyuk-Sang;Yoon, Hwan-Hee;Lee, Yong-Joo
    • Tunnel and Underground Space
    • /
    • v.28 no.6
    • /
    • pp.635-650
    • /
    • 2018
  • Many people have been recognized that the Korean Peninsula is no longer safe area from the earthquake by the recent earthquakes occurred in the country. The earthquakes that occurred at Pohang and Gyeongju appeared differently from them considered in the seismic design and researches on the seismic design method have been also conducted by many researchers. Studies on seismic loads are mainly focused on existing superstructures, and research involving them has been actively carried out in reality. However, paper regarding structural stability of reinforcement from seismic load such as soil-nails, rock-bolts, ground anchors which were constructed to ensure stability of serviced structure have been published rarely. In this study, ground anchor been effected by static load and seismic load which is settled in the weathered rock is analyzed. Results for static load are obtained from field test and seismic load is from numerical analysis. In this study, the behavioral characteristics of the ground anchor were analyzed by numerical analysis in case of seismic loading based on the result of the in-situ tensile test of the ground anchor settled weathered rock. As a result, settlement of concrete block due to application of tension force for ground anchor occurred as well as following loss of axial force for ground anchor. Also, as bond length and period of seismic load are longer, increasement of displacement is greater.

Test Result Analysis of a 1MW HTS Motor for Industry Application

  • Baik, S.K.;Kwon, Y.K.;Kim, H.M.;Lee, E.Y.;Kim, Y.C.;Park, H.J.;Kwon, W.S.;Park, G.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.2
    • /
    • pp.33-36
    • /
    • 2009
  • A 1 MW class HTS (High-Temperature Superconducting) synchronous motor has been developed. This motor is aimed to be utilized for industrial application such as large motors operating in large plants. The HTS field coil of the developed motor is cooled by way of neon thermo siphonmechanism and the stator (armature) coil is cooled by water through hollow copper conductor. This paper also describes evaluation of some electrical parameters from performance test results of our motor, which was conducted at steady state in generator mode and motor mode. Open and short circuit tests were conducted in generator mode while a 1.1 MW rated induction machine was rotating the HTS machine. Electrical parameters such as mutual inductance and synchronous inductance are deduced from these tests. Load test was done upto rating torque during motor mode and efficiency was measured at each load torque.

Analysis of Correlation among Various Compaction Evaluation Methods for Estimating of the Bearing Capacity on Subgrades (노상토의 지지력 평가를 위한 다짐평가기법의 상관성 분석)

  • Lee, Joonyong;Jeoung, Jae-Hyeung;Choi, Changho;Kim, Jin-Young;Jin, Hyunwoo
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.4
    • /
    • pp.45-58
    • /
    • 2015
  • Even though the plate bearing test (PBT) to evaluate the load baring capacity and the field density test to evaluate the relative density are mainly used for quality control of soil compaction in Korea, use of the dynamic cone penetrometer test (DCPT) and the dynamic plate bearing test (DPBT) considering economic feasibility, rapidity, and suitability for field conditions increase to use for quality control of soil compaction. In this study, bearing capacity and relative density of subgrade with thickness of 20 cm, 30 cm, and 40 cm are estimated using PBT, DCPT, DPBT and field density test in three field compaction tests, and the relationship among various compaction evaluation methods is analyzed and discussed.

The Analysis of Skin Friction on Small-scale Prebored and Precast Piles Considering Cement Milk Influence (시멘트풀의 영향을 고려한 축소모형 매입말뚝의 거동분석)

  • Park, Jong-Jeon;Jung, Gyung-Ja;Jeong, Sang-Seom
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.1
    • /
    • pp.5-15
    • /
    • 2017
  • Skin friction may be one of the most critical factors in designing the prebored and precast pile. Special attention was given to the interface behavior of cement milk-surrounding soil during the installation of prebored and precast pile. Small-scale field model pile test was conducted for the case of single pile. The size and geometry of the small-scale field model piles were designed with pile length 1.3m, boring diameter 0.067 m. Quick maintain-load test was conducted for the cases of boring diameter 150, 125, 90, 86, 74 mm and water-cement ratio 90, 70, 60%. It was shown that the bearing capacity of the pile increased as the cement-water ratio and cement milk thickness increased. Considering the scale effect between the small-scale model test and the actual construction site, it was found that cement milk thickness of 0.1~0.4D (50~200 mm) was reasonable for the stability of the structure. Also, the proper cement paste water / cement ratio was about 70% when considering the results of this study and quality control.