CHANCE OF MECHANICAL PROPERTIES IN NITINOL BY FATIGUE LOAD

피로하중에 의한 NITINOL의 기계적 성질의 변화

  • Ha, Kook-Bong (Department of Dentistry, Graduate School, Pusan National University) ;
  • Shon, Woo-Sung (Department of Dentistry, Graduate School, Pusan National University)
  • 하국봉 (부산대학교 치과대학 교정학교실) ;
  • 손우성 (부산대학교 치과대학 교정학교실)
  • Published : 1993.12.01

Abstract

Nitinol wires are now widely used in the orthodontic field because of their unique shape memory effect and superelasticity. But sometimes Nitinol wires are deformed in clinical use. Fatigue load is possible cause of Nitinol deformation. To determine the effect of fatigue load to the mechanical properties of Nitinol, various fatigue cycle$(1\times10^4,\;2\times10^4,\;3\times10^4,\;4\times10^4,\;5\times10^4,\;1\times10^5)$ were applied to $0.017\times0.025$ inch Nitinol. The results obtained were as follows ; 1. Applied load increased as fatigue cycle increased in three point bending test. 2. Maximum tensile strength and elongation decreased as fatigue cycle increased. 3. Tn SEM, brittle fracture pattern was increased when fatigue cycle increased.

Keywords