• Title/Summary/Keyword: fiber sensor

Search Result 1,236, Processing Time 0.025 seconds

Measurement of the Degree of Cure of Thermosetting Resin Matrix Composite Materials (열경화성수지 복합재료의 경화정도의 측정에 관한 연구)

  • 김진수;이대길
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.9
    • /
    • pp.2154-2164
    • /
    • 1995
  • In this study, a dielectric cure monitoring system which consists of an electric circuit, a sensor and a personal computer was developed to on-line monitor the dielectric properties of carbon fiber epoxy composite materials. Also, the kinetic model of carbon fiber epoxy composite materials was developed by curve fitting of differential scanning calorimetry data. The start and end points of cure and the relationship between the dissipation factor and the degree of cure were obtained by comparing the dissipation factor from the dielectric properties with the degree of cure from the DSC data. The relationship between the dissipation factor and the degree of cure was tested under various temperature profiles.

Development of Measuring Data System for Reinforced Concrete Beam Using Fiber Bragg Grating Sensors (광섬유 브래그 격자 센서를 이용한 R.C보의 계측 시스템 개발)

  • Kwak, Kae-Hwan;Jang, Hwa-Sup;Yang, Dong-Oun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.47-50
    • /
    • 2005
  • Fiber Bragg Grating (FBG) Sensors as advanced measuring system are introduced and actively being applied to establish a smart monitoring system for bridge maintenance. This study develops FBG sensors and suggests a smart monitoring system. As for its first step, to verify the reliability of FBG sensors that developed, a specimen is made FBG sensors and electric sensor are attached. Then, Static test is conducted on the specimen on the specimens to check reliability. In addition, this study estimates the optimum deflection curve that converts strain curve data measured by FBG sensors into deflection.

  • PDF

The Embedding Reliability and The Spectrum Characteristic of Fiber Bragg Grating Sensor Embedded into Composite Laminates (복합재 평판 내부에 삽입된 광섬유 브래그 격자 센서의 삽입안전성과 신호 특성에 관한 연구)

  • 이정률;류치영;강현규;김대현;구본용;강동훈;홍창선;김천곤
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.11a
    • /
    • pp.238-244
    • /
    • 2000
  • FBGs have been extensively used as strain sensors or temperature sensors in a variety of applications related to composites because of embedding ability, small size and multiplexing capability. We inspected embedding environments inside composites with optical fiber by microscope analysis and birefringence characteristics of FBG embedded into textile composite laminate by cure monitoring using a high power WSFL. The cure monitoring of the cases with the striped FBG and the recoated FBG provided comprehensive understandings about the birefringence effect induced by the transverse stress. And these results allowed to consider a recoating method as an important tool to relieve birefringence.

  • PDF

Novel design of interdigitated electrodes for piezoelectric transducers

  • Jemai, Ahmed;Najar, Fehmi
    • Smart Structures and Systems
    • /
    • v.22 no.4
    • /
    • pp.369-382
    • /
    • 2018
  • Novel design of interdigitated electrodes capable of increasing the performance of piezoelectric transducers are proposed. The new electrodes' geometry improve the electromechanical coupling by offering an enhanced adaptation of the electric field to the interdigitated electrode configuration. The proposed analysis is based on finite element modeling and takes into account local polarization effect. It is shown that the proposed electrodes considerably increase the strain generation compared to flat electrode arrangement used for Macro Fiber Composite (MFC) and Active Fiber Composite (AFC) actuators. Also, electric field singularities are reduced allowing better reliability of the transducer against electric failure.

Characteristics of fiber-optic sensor to detect ultrasonic by discharge in transformer and signal analysis with wavelet transform (변압기 내부 방전에 의한 초음파 감지용 광섬유 센서 특성과 측정데이터의 wavelet 분석)

  • Lee, S.H.;Ji, S.W.;Kim, C.N.;Lee, K.S.;Lee, C.H.;Kim, K.Y.;Do, D.H.;Kim, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1882-1884
    • /
    • 2003
  • This paper introduced the characteristics of fiber-optic Mach-Zehnder interferometer to detect ultrasonic waves by discharges in oil. Noise-reduction method with wavelet and frequency-domain analysis was performed.

  • PDF

Sweeping Linearization of Wavelength Swept Laser using PID Control (PID 제어를 이용한 파장 스위핑 레이저의 스위핑 선형화)

  • Eom, Jinseob
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.6
    • /
    • pp.412-419
    • /
    • 2020
  • In this study, a PID control method for sweeping automatic linearization of a wavelength swept laser is proposed. First, the closedloop transfer function embodying the PID control is derived. Through the simulation of the function, Kp = 0.022, Ki = 0.008, Kd = 0.002 were obtained as the best PID coefficients for fast linear sweeping. The performance test using the PID coefficients showed that linear sweeping was held up well with a 98.7% decrement in nonlinearity after the 10th feedback, and 45 nm sweeping range, 1 kHz sweeping frequency, and 8.8 mW average optical power were obtained. The equipment consists of a fiber Bragg grating array, an optical-electronic conversion circuit, and a LabVIEW FPGA program. Every 5s, automatic feedback and PID control generate a new compensated waveform and produce a better linear sweeping than before. Compared with nonlinear sweeping, linear sweeping can reduce the cumbersome and time-consuming recalibration processes and produce more accurate measurement results.

On-site water level measurement method based on wavelength division multiplexing for harsh environments in nuclear power plants

  • Lee, Hoon-Keun;Choo, Jaeyul;Shin, Gangsig;Kim, Sung-Man
    • Nuclear Engineering and Technology
    • /
    • v.52 no.12
    • /
    • pp.2847-2851
    • /
    • 2020
  • A simple water level measurement method based on wavelength division multiplexing (WDM) is proposed and demonstrated. The measurement principle is based on the change of Fresnel reflection occurring at the end facet of the optical fiber tip (OFT). To increase the spatial resolution of water level sensing, a broadband light source (BLS) and an arrayed waveguide grating (AWG) are employed. The OFTs are multiplexed with the dedicated wavelength channels of AWG. By measuring all of the reflection powers reflected at the OFTs with a proposed on-site reflectometer, the water level can be monitored continuously for a fast emergency response. Moreover, it can be implemented easily with the commercially available optical components and devices with the simple configuration.

Cure Monitoring of Composite Laminates Using Fiber Optic Sensors (광섬유 센서를 이용한 복합재료 적층판의 성형 모니터링)

  • Gang, Hyeon-Gyu;Gang, Dong-Hun;Park, Hyeong-Jun;Hong, Chang-Seon;Kim, Cheon-Gon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.2
    • /
    • pp.59-66
    • /
    • 2002
  • In this paper, we present the simulataneous monitoring of the strain and temperature during cures f various composite laminates using fiber Bragg grating/extrinsic Fabry-Perot interferometric (FBG/EFPI) hybrid sensors. Three types of graphite/epoxy composite were used : a undirectional laminate, a symmetric cross-ply laminate, and a fabric laminate. Two FBG/EFPI hybrid sensors were embedded in each laminate at different directions and different locations. We performed the real time monitoring of fabrication strains and temperatures at two points within the composite laminates during cure process in an autoclave. Throuhg these experiments, FBG/EFPI sensors proved to be an efficient choice for smart cure monitoring of composite structures.

An integrated approach for structural health monitoring using an in-house built fiber optic system and non-parametric data analysis

  • Malekzadeh, Masoud;Gul, Mustafa;Kwon, Il-Bum;Catbas, Necati
    • Smart Structures and Systems
    • /
    • v.14 no.5
    • /
    • pp.917-942
    • /
    • 2014
  • Multivariate statistics based damage detection algorithms employed in conjunction with novel sensing technologies are attracting more attention for long term Structural Health Monitoring of civil infrastructure. In this study, two practical data driven methods are investigated utilizing strain data captured from a 4-span bridge model by Fiber Bragg Grating (FBG) sensors as part of a bridge health monitoring study. The most common and critical bridge damage scenarios were simulated on the representative bridge model equipped with FBG sensors. A high speed FBG interrogator system is developed by the authors to collect the strain responses under moving vehicle loads using FBG sensors. Two data driven methods, Moving Principal Component Analysis (MPCA) and Moving Cross Correlation Analysis (MCCA), are coded and implemented to handle and process the large amount of data. The efficiency of the SHM system with FBG sensors, MPCA and MCCA methods for detecting and localizing damage is explored with several experiments. Based on the findings presented in this paper, the MPCA and MCCA coupled with FBG sensors can be deemed to deliver promising results to detect both local and global damage implemented on the bridge structure.

A Study on the Characteristics of Mass Transfer in Hollow Fiber Membranes (중공사막에서의 물질전달 특성에 관한 연구)

  • 김기범;김종석;김종수;유일수;이왕로;김성종
    • Membrane Journal
    • /
    • v.14 no.2
    • /
    • pp.142-148
    • /
    • 2004
  • This paper presents the enhancement of oxygen transfer efficiency using vibrating intravascular lung assist device (VIVLAD) for patients having chronic respiratory problems. The flow rate was controlled by the pump and monitored by a built-in flow meter. The vibration apparatus was composed of a piezo-actuator, a function generator, and a power amplifier. Gas flow rates of up to 6 L/min through the 120-cm-long hollow fibers have been achieved by exciting a piezo-actuator. The output PVDF sensor and FRF (frequency response function) were investigated by various frequency in VIVLAD. As a result, the maximum oxygen transfer rate was found to occur with maximum amplitude and the transfer of vibration to the hollow fiber membranes. It was excited by the frequency band of 35 Hz at various distilled water flow rates, and various module types.