• 제목/요약/키워드: fence

검색결과 434건 처리시간 0.025초

곤돌라 안전난간 제거 등으로 인한 추락재해 감소방안 (Reducing the Falling Accident due to the Removal of Safety Fence from Gondola)

  • 변형식;임종국;양원백
    • 대한안전경영과학회지
    • /
    • 제21권2호
    • /
    • pp.9-14
    • /
    • 2019
  • Gondola is widely used as a construction facility to perform external finishing work without using scaffolding at a construction site. However, since 2000, there have been 17 deaths from now so these risks associated with work can not be ignored. Therefore, it is expected that it will contribute greatly to prevent related disasters if introducing necessary measures to prevent repeated related disasters and installing additional safety devices. In order to eliminate the risk factor according to the operation of the gondola, it is necessary for the operator to use it to use it while the examination of each product is completed, and to use the over load Dangerous arbitrary measures such as arbitrary operation of the prevention device, removal of the safety fence for convenience of work, installation of the wire rope installed in the air, falling out of the wire rope and falling to the ground Do not perform such sealing measures so that any operation of the overload prevention device can not be done so as not to take such arbitrary measures, or wire the power supply wire to the safety fence so as not to delete the safety fence. Then, when the safety fence is removed, so that it does not become a gondola operation, or when replacing the wire rope in the air, to prevent the wire rope from coming off, Additional measures such as installing falling down prevention device may be necessary.

수치해석을 통한 지주 보강에 따른 고강도 낙석 방지울타리 구조성능 평가 (Evaluation of Structural Performance for High Strength Rockfall Protection Fence according Reinforcement of H-Beam using Numerical Analysis)

  • 진현우;서상훈;이두호;황영철
    • 한국지반환경공학회 논문집
    • /
    • 제24권1호
    • /
    • pp.25-36
    • /
    • 2023
  • 국내 낙석, 토사 붕괴 등의 피해를 방지하기 위해 설치하는 것은 낙석 방지책이다. 이 중 낙석 방지울타리는 50kJ의 낙석 운동에너지에 설계가 되고 있다. 낙석 운동에너지의 경우, 발생하는 사면의 형태에 따라 크게 달라지며 기존의 연구로는 ETAG 27을 이용한 100kJ급 낙석 충돌에너지에 대한 울타리 성능평가를 실시하였다. 하지만 기존의 연구들은 낙석 방지울타리가 신규로 설치되는 것을 대상으로 하였다. 본 연구에서는 수치해석을 통해 신규 설치가 아닌 기존의 낙석 방지울타리에 보강부재를 설치하고, 120kJ의 낙석 운동에너지에 대해 방어할 수 있는 고강도 낙석 방지울타리의 구조 성능을 평가하였다.

현장 낙석실험을 통한 낙석방지울타리의 특성 및 성능 평가 (Characteristics and Energy Absorbing Capacity for Rockfall Protection Fence from In-Situ Rockfall Tests)

  • 구호본;박혁진;백영식
    • 한국지반공학회논문집
    • /
    • 제17권6호
    • /
    • pp.111-121
    • /
    • 2001
  • 낙석방지울타리는 도로절개면 상부에서 발생한 낙석의 도로 유입을 차단하기 위하여 설치되는 구조물로 국내 국도 절개면 중 70%이상 시공되어 있다. 이와 같이 도로 절개면의 재해예방을 위하여 범용적으로 사용되는 시설물로서 그 중요성이 매우 강조될 수 있으나 국내의 경우 아직까지 설계 및 시공에 대한 기준이 미흡하고 절개면의 높이, 경사도 등 특성을 고려하지 않은 단일 표준단면도에 의해 설계, 시공되어 이의 효율성에 한계가 있는 것이 사실이다. 따라서, 본 연구에서는 현장실험을 통해 낙석방지울타리의 흡수가능에너지를 파악하였다. 실험을 위하여 높이 20m, 경사 65도의 절개면을 선정하여 4개 규모의 콘크리트 볼(0.7, 1.3, 2.3, 4.3 톤)을 절개면 상부로부터 낙하시켜 낙석방지 울타리의 성능을 평가하였다. 본 논문은 시공완료된 절개면을 대상으로 현장실물실험을 통해 낙석운동에너지, 암반의 반발계수, 낙석방지울타리의 흡수에너지 등을 산정하여 절개면 특성별 낙석방지울타리의 설계에 필요한 기초 자료를 제공하고자 하였다. 현장실험을 통해 획득한 낙석방지울타리의 흡수가능에너지는 약 50kJ로 이는 약 0.4톤의 낙석이 10m의 높이에서 낙하할 때 발생하는 에너지와 동일하다.

  • PDF

낙석해석프로그램을 이용한 비탈면 높이, 낙석중량별 도약높이 및 충격에너지 검토 (A Study on Bounce Height and Impact Energy Considering Slope Height, Rockfall Weight Using Rockfall Program Considering Slope Height, Rockfall Weight)

  • 유병옥;한원준;이상덕;심재원
    • 한국지반환경공학회 논문집
    • /
    • 제12권3호
    • /
    • pp.47-54
    • /
    • 2011
  • 절토비탈면에서 발생되는 낙석에 대한 안정성을 확보하기 위해 설치되는 낙석방지 울타리는 기본적으로 12.5m 높이에서 400kg인 암괴가 낙하될 때 발생되는 50kJ의 충격에너지를 가정하여 설계되고 있다. 그러나 암괴의 크기가 커지거나 높이가 높은 곳에서 낙하하는 경우에는 기존의 낙석방지울타리로는 안정성 확보가 어려운 실정이다. 본 논문은 낙석해석프로그램을 이용하여 암괴중량에 따른 비탈면 높이, 울타리와의 이격거리, 경사각 등의 변화를 주어 낙석에 대한 안정성 분석을 실시하여 보았다. 해석결과 기존의 2.5m 높이의 낙석방지울타리는 설계하중 조건인 400kg 암괴가 낙석 될 때, 비탈면 높이가 20m 이내의 일부를 제외하고 대부분 낙석에 대해 안정성이 확보될 수 있으나, 20m 이상인 경우 낙석의 튀는 높이가 낙석방지울타리를 넘는 경우가 빈번하고 낙석의 충격에너지도 설계충격에너지 이상인 경우가 발생되는 결과를 얻을 수 있었다. 그러므로 낙석방지울타리의 설계 시 표준도에 준하여 설계하는 방식보다 지반조건에 따른 낙석의 안정성 검토를 실시한 후에 낙석 도약높이 및 충격에너지를 평가하여 낙석방지울타리를 설계하는 것이 적절할 것으로 판단된다.

해양환경 보호를 위한 오일펜스의 내구성 향상 : 검정제도 개선 방향 (Oil Fence Durability Enhancement for Marine Environmental Protection : Improvement of Inspection Process)

  • 장판길;서정목;이희진
    • 해양환경안전학회지
    • /
    • 제27권6호
    • /
    • pp.731-736
    • /
    • 2021
  • 오일펜스는 사고 초동조치로 기름 확산을 효과적으로 방지하는 아주 큰 역할을 한다. 그러나 사고 현장의 기름이나 구조물 등의 의해 파손되어 폐기되는 경우가 많이 발생되며, 회수된 폐 오일펜스는 소각처리과정에서 미세먼지 발생과 발암성분의 대기 배출 가능성이 높은 상황이다. 또한, 본체 일부가 손상되어 해상으로 유출되면서 해양 미세플라스틱과 같은 2차 환경오염의 원인이 될 수 있다. 따라서 본 연구에서는 현재 우리나라에서 가장 많이 사용하는 고형식 오일펜스 원단을 이용하여 내구성을 평가하였다. 본체부 샘플을 해수와 기름에 노출시킨 후, 기간과 온도에 따른 인장강도를 측정하였다. 그 결과 5일 노출후 해수에서는 13 %가 기름에서는 3 %가 감소하였으며, 온도변화에도 영향을 받는 것으로 나타났다. 오일펜스는 해수와 기름에 노출 뿐만 아니라 바람과 파도 등 다양한 영향을 받게 되므로 오일펜스의 내구성은 강화되어야 한다. 또한, 해양환경보호 측면에서 지속적인 사용을 위해서는 내구성 강화는 필수적이다. 이에 오일 펜스의 본체부 재질검사가 강화되어야 한다고 판단하여, 검정 시 본체부 원단 인장강도 품질을 확인할 수 있는 검정 개선방안을 제안하였다.

벽면근처에 놓인 정방형주의 펜스에 의한 항력저감 (Drag Reduction by Fence of a Square Prism near Plane Wall)

  • 노기덕;김광석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2567-2572
    • /
    • 2007
  • The suppression of fluid force acting on a square prism near plane wall was studied by attaching fences on the corners of the prism. The height of the fence was 10% of the square width and the range of Reynolds number considered was Re=$2.0{\times}10^4$. The experimental parameters were the attaching position and numbers of fences, the space ratios G/B(G/B=0.1${\sim}$1.2) between prism and plane wall. The average drag coefficients were increased and the average lift coefficients were decreased and increased with the space ratios toward plane wall. The drag of the prism was reduced average 7.6% with the space ratios by attaching the normal fence at the rear and upper corner and the horizontal normal fence at the rear and lower corner on the prism. In this case, the separated flow at the front and upper corner was reattached on the upper side of the prism and the vortex streets between the prism and plane wall were appeared more slowly than that of prism without fences.

  • PDF

입구경계층 두께와 경계층 펜스가 터빈 캐스케이드내 열전달 특서에 미치는 영향 (Effects of the Inlet Boundary Layer Thickness and the Boundary Layer Fence on the Heat Transfer Chracteristics in a Turbine Cascade)

  • 정지선;정진택
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.765-770
    • /
    • 2001
  • The objective of the present study is to investigate the effects of the various inlet boundary layer thickness on convective heat transfer distribution in a turbine cascade endwall and blade suction surface. In addition, the proper height of the boundary layer fences for various inlet boundary layer thickness were applied to turbine cascade endwall in order to reduce the secondary flow, and to verify its influence on the heat transfer process within the turbine cascade. Convective heat transfer distributions on the experimental regions were measured by the image processing system. The results show that heat transfer coefficients on the blade suction surface were increased with an augmentation of inlet boundary layer thickness. However, in a turbine cascade endwall, magnitude of heat transfer coefficients did not change with variation of inlet boundary layer thickness. The results also present that the boundary layer fence is effective in reducing heat transfer on the suction surface. On the other hand, in the endwall region, boundary layer fence brought about the subsidiary heat transfer increment.

  • PDF

새로운 Fence 전극 구조에 의한 ac-PDP 효율 개선에 관한 연구 (A Study on the Improvement of the luminous Efficiency in ac-PDP with New Fence Structure)

  • 권비수;옥정우;김현종;이돈규;김동현;이호준;박정후
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.201-203
    • /
    • 2005
  • To improvement the performance of PDPs, we developed an ac-PDP with new fence structure. By measuring minimum sustaining voltage(Vs), discharge current(Ion), discharge(Ioff), and brightness of the light from a 4-inch at-PDP, performances of the conventional structure and proposed structure are compared. The experimental results show that the test panel with the proposed new fence structure shows high luminance by 10%, and high luminous efficiency by 30% compared with the conventional structure at the Ne-Xe(8%) gas mixture of 400 torr.

  • PDF

철제펜스로 지지된 동력배선의 단락.지락에 의한 전기화재 발생 개연성 연구 (A Study on the Possibility of Electrical Fires due to the Short Circuit and Ground Fault of Power Cable Supported by an Iron Fence)

  • 김정훈;박병기;송종혁;정기창
    • 한국안전학회지
    • /
    • 제22권6호
    • /
    • pp.41-45
    • /
    • 2007
  • Short circuit and ground fault account for the primary causes of electrical fires. In this research, real-scale experiments were conducted to assess the possibility of electrical fires due to these causes. The experiment conditions were identical with an actual fire accident, in which the power cable was supported by an iron fence. The purposes of this research are to investigate the short circuit caused by wire cutting, the conductivity of the iron fence depending on its coating conditions, and the ground fault of one wire or two wires in an effort to reconstruct the fire accident. The test results show that, owing to the instant operation of circuit breaker in the moment of short circuit or ground fault, the generated ignition energy is far less than necessary to start an ignition. Therefore it is concluded that electrical fire is highly unlikely if the electric system is protected by a circuit breaker with normal functions.

AC PDP의 휘도 및 효율 향상을 위한 새로운 Fence 전극구조 (The new fence structure in the AC PDP for a high luminance and luminous efficiency)

  • 윤초롬;조성용;석창우;한문기;하창승;박차수;이해준;박정후
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1420-1421
    • /
    • 2007
  • 기존의 fence전극구조는 ITO구조에 비해 방전전류가 감소함에도 불구하고 휘도가 대폭 감소하여 효율이 떨어지는 것으로 알려져 있다. 따라서 효율 상승을 위하여 다음과 같은 fence구조를 제안하였다. 실험은 reference(Conventional T-전극구조)와 제안된 구조들로 구성되어 있는 4-inch AC-PDP test Panel을 직접 제작하여 discharge current, luminance, luminous efficiency를 측정하여 비교하였다. 제안된 구조들은 방전전류 최대 10%감소, 휘도는 최대 20%증가하였고 효율면에서도 최대 20%의 상승을 보였다.

  • PDF