• 제목/요약/키워드: feeding pressure

검색결과 297건 처리시간 0.027초

Basic Model for Propellant Tank Ullage Calculation (추진제탱크 얼리지 해석을 위한 기본모델)

  • Kwon, Oh-Sung;Cho, Nam-Kyung;Cho, In-Hyun
    • Aerospace Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.125-132
    • /
    • 2010
  • Estimation of pressurant mass flowrate and its total mass required to maintain propellant tank pressure during propellant outflow is very important for design of pressurization control system and pressurant storage tank. Especially, more pressurant mass is required to maintain pressure in cryogenic propellant tank, because of reduced specific volume of pressurant due to heat transfer between pressurant and tank wall. So, basic model for propellant tank ullage calculation was proposed to estimate ullage and tank wall temperature distribution, required pressurant mass, and energy distribution of pressurant in ullage. Both test and theoretical analysis have been conducted, but only theoretical modeling method was addressed in this paper.

Development of the Spherical Flange used in a Cryogenic High Pressure Pipe (극저온 고압 배관용 구형 플랜지 개발)

  • Moon, Il-Yoon;Moon, In-Sang;Yoo, Jae-Han;Lee, Soo-Young
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 한국추진공학회 2011년도 제36회 춘계학술대회논문집
    • /
    • pp.283-288
    • /
    • 2011
  • The spherical flange was designed to apply to a cryogenic high pressure pipe of the Liquid Rocket Engine. It is designed that the spherical flange is able to be assembled and kept airtight upto $2.5^{\circ}$ of the axial misalignment between the combined components. It increases the degree of freedom of the engine assembly. The spherical flange is composed of a ball and socket joint, a metal seal and spherical type bolts, washers. The prototype was verified by leak test at the room temperature and the cryogenic temperature. Additionally the strength test and the destructive test were performed at the room temperature.

  • PDF

Development of the Spherical Flange Used in a Cryogenic High Pressure Pipe (극저온 고압 배관용 구형 플랜지 개발)

  • Moon, Il-Yoon;Moon, In-Sang;Yoo, Jae-Han;Lee, Soo-Young
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • 제15권3호
    • /
    • pp.64-69
    • /
    • 2011
  • The spherical flange was designed to apply to a cryogenic high pressure pipe of a liquid rocket engine. It is designed that the spherical flange is able to be assembled and kept airtight up to $2.5^{\circ}$ of the axial misalignment between the combined components. It increases the degree of freedom of the engine assembly. The spherical flange is composed of a ball and socket joint, a metal seal, spherical type bolts and washers. The prototype was verified by leak test at the room temperature and the cryogenic temperature. Additionally the strength test and the destructive test were performed at the room temperature.

Performance assessment of HEPA filter to reduce internal dose against radioactive aerosol in nuclear decommissioning

  • Hee Kwon Ku;Min-Ho Lee;Hyunjin Boo;Geun-Dong Song;Deokhee Lee;Kaphyun Yoo;Byung Gi Park
    • Nuclear Engineering and Technology
    • /
    • 제55권5호
    • /
    • pp.1830-1837
    • /
    • 2023
  • The thermal cutting of contaminated or activated metals during decommissioning nuclear power plants inevitably results in the release of radioactive aerosol. Since radioactive aerosols are pernicious particles that contribute to the internal dose of workers, air conditioning units with a HEPA filter are used to remove radioactive aerosols. However, a HEPA filter cannot be used permanently. This study evaluates the efficiency and lifetime of filters in actual metal cutting condition using a plasma arc cutter and a high-resolution aerosol detector. The number concentration and size distribution of aerosols from 6 nm to 10 ㎛ were measured on both the upstream and downstream sides of the filter. The total aerosol removal efficiency of HEPA filter satisfies the standard of removing at least 99.97% of 0.3 ㎛ airborne particles, even if the pressure drop increases due to dust feeding load. The pressure drop and particle size removal efficiency at 0.3 ㎛ of the HEPA filter were found to increase with repeated cutting experiments. By contrast, the efficiency of used HEPA filter reduced in removing nano-sized aerosols by up to 79.26%. Altogether, these results can be used to determine the performance guidance and replacement frequency of HEPA filters used in nuclear power plants.

Effects of the Ethanol-extract of Allium wageki on the Fructose-induced Hypertensive Rats (쪽파 에탄올 추출물이 과당-유도 고혈압 흰쥐에 미치는 영향)

  • Kang, Dae-Gill;Sohn, Eun-Jin;Lee, An-Sook;Lee, Yun-Mi;Yin, Ming-Hao;Noh, Suk-Yun;Lee, Ho-Sub
    • Korean Journal of Pharmacognosy
    • /
    • 제33권4호통권131호
    • /
    • pp.384-388
    • /
    • 2002
  • The effects of the ethanol (EtOH)-extract of Allium wageki were studied on the changes of body weight (BW), systolic blood pressure (SBP), triacylglycerol (TG), cholesterol, and insulin levels in Sprague-Dawley rats in which high fructose feeding elicited hyperinsulinemia, hypertriglyceridemia, and hypertension. SBP and BW were measured for 7 weeks on the fructose diet, fructose/EtOH-extract, vehicle- treated, or vehicle/EtOH-treated rats. The EtOH-extract of Allium wageki blocked the increases of SBP ($119.4{\pm}3.7\;mmHg$ in fructose/EtOH-extract of Allium wageki; $141{\pm}4.3 \;mmHg$ in fructose diet, p<0.01) and BW ($368{\pm}11.4\;g$ in fructose/EtOH-extract of Allium wageki; $402{\pm}15.7\;g$ in fructose diet, p<0.05) by high fructose-diet. The increases of TG, total cholesterol, and insulin levels were also blocked by administration of EtOH-extract of Allium wageki in fructose-induced hypertensive rats. These results suggest that EtOH-extract of Allium wageki has protect effects on the increases of TG, total cholesterol, insulin level, and blood pressure in fructose-induced hypertensive rats.

An Analysis of Design Factors for Developing Opuntia Humifusa Spines Removal Device

  • Jang, Ik Joo;Ha, Yu Shin
    • Journal of Biosystems Engineering
    • /
    • 제38권3호
    • /
    • pp.215-221
    • /
    • 2013
  • Purpose: Opuntia Humifusa has been used in the food and beauty industry after removing spines and glochids clearly. This study compared the methods used in removing spines and analyzed the design factors for developing a spine removal device. Method: This study compared the spine removal ratios in accordance with the length of brush, water spray pressure, the number of water spray, and the size of Opuntia Humifusa in a rotating brush device and a water spray device. In addition, this study compared the reversal ratios according to the inclination angle of a conveyor, the drop height of Opuntia Humifusa, and the speed of the conveyor to analyze the reversal factors. Results: The spines were not removed clearly in the rotating brush method, and the glochids were nailed deeply. The spine removal ratio was 96.9% with the water spray pressure of 20 $kgf/cm^2$ and the conveyor speed of 10 cm/s in the water spray method. The number of water spray was correlated with the spine removal ratio, and the average spine removal ratio was 95.6% with three cycles of water spray. The reversal ratio was 97% with the inclination angle of the conveyor $20^{\circ}$, the drop height of 380 mm, and the conveyor speed of 10 cm/s. Conclusions: In order to develop a Opuntia humifusa spine removing device, this study compared the rotating brush and water spray methods. As a result, each spine removal performance of the rotating brush and water spray methods was 96.9% and 95.6%, respectively. Although the performance of the rotating brush method was slightly higher than that of the water spray method, the water spray method was suitable for removing spines from stem because the epidermis of stem was damaged and the glochids were nail deeply in the rotating brush method. Further studies on appropriate arrangement of spray nozzles, maintaining the optimal water spray pressure, the speed and angle control of the feeding conveyor, and devices for inducing the stem to the center will be needed in combining the water spray device and the reversal device.

Effect of Taking Meal on Pulse Diagnosis in Healthy Subjects (식사가 정상인의 맥에 미치는 영향 분석)

  • Lee, Yu-Jung;Lee, Jeon;Lee, Hae-Jung;Choi, Eun-Ji;Kim, Jong-Yeol
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • 제21권6호
    • /
    • pp.1670-1675
    • /
    • 2007
  • The pulse diagnosis studies reported to date has mainly been performed to clinically reveal the pulse wave characteristics according to the specific diseases, whereas no attempts have been made to study the effects on the pulse wave characteristics of the daily activities such as taking meals, exercise, and sleep, etc. This work reports the effect of feeding stimulus on the healthy subjects on the pulse wave pattern which has quantitatively been analyzed using the objective model for the pulse diagnosis in oriental medicine. The pulse waves right before/after the meal and 30 minutes after the meal were measured using the pulse analyzing equipment (3D-Mac, Daeyo Medi, Korea) and at the same time oriental medicine doctors' diagnoses were given. The pulse parameters obtained from the equipment and clinical records on the subjects were statistically processed and the variables showing statistically significant differences were analyzed. The results indicate that the pulse pressure, the pulse rate, and the respiratory rate increase while the blood pressure decreases after the meal. For the floating/sinking and the deficient/excess coefficients characterizing the pulse states described in the oriental medicine, the floating/sinking coefficients were observed to decrease whereas the deficiency/excess coefficients increase after the meal. The results indicates that besides the standard bio-indicators like blood pressure and respiratory rate, etc., the pulse wave characterization in terms of the pulse classifications in the oriental medicine using the floating/sinking, deficient/excess pulse states provide an important piece of biomedical information.

Hospital-Acquired Pressure Injury: Clinical Characteristics and Outcomes in Critical Care

  • Hyun, Sookyung;Moffatt-Bruce, Susan;Newton, Cheryl;Hixon, Brenda
    • International Journal of Advanced Culture Technology
    • /
    • 제7권2호
    • /
    • pp.28-33
    • /
    • 2019
  • Electronic health records (EHRs) enable us to use and re-use electronic data for various multiple purposes, such as public reporting, quality improvement, and patient outcomes research. Current hospital-acquired pressure injury (HAPI) risk assessment instruments have not been specifically developed for intensive care unit (ICU) patients and showed false positive rates in this specific populations. Previous research studies report a number of risk factors; however, it is still not clear what factors influence ICU HAPI in this population. As part of a larger research study, we performed an exploratory analysis by using a large electronic health record data. The aims of this study were to compare characteristics of patients who developed HAPIs during their ICU stay with those who did not, and to determine whether the two groups were different in the aspects of length of ICU stay, discharge disposition, and discharge destinations. We conducted chi-square test and t-test for group comparison. Association was examined by using bivariate analyses. Pearson correlation coefficients were used to examine correlation between LOS and number of medications. Our findings suggest a number of consistent and potentially modifiable risk factors, such as sedation, feeding tubes, and the number of medications administered. The mortality of the HAPI group was significantly higher than the non-HAPI group in our data. Discharge disposition was significantly different between the groups. 67% of the HAPI group transferred to intermediate or long-term care hospitals whereas 57.7% of the non-HAPI group went home after discharge. Awareness of these risk factors can lead to clinical interventions that can be preventative in the ICU setting.

Experimental investigation of friction in guide zone of tube hydroforming with material and lubricant (튜브 액압성형 공정의 가이드영역에서 소재 및 윤활에 따른 마찰 특성의 실험적 연구)

  • Yi, H.K.;Yim, H.S.;Lee, G.Y.;Lee, S.M.;Chung, C.S.;Moon, Y.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 한국소성가공학회 2008년도 추계학술대회 논문집
    • /
    • pp.83-86
    • /
    • 2008
  • In this study, friction test was proposed to obtain coefficient of friction between tube and die in guide zone of tube hydroforming and friction coefficients were evaluated at different materials, viscosity of lubricants and internal pressures. For this study, STKM11A and SUS tubes were prepared. The tube was expanded by an internal pressure against the tool wall. By pushing the tube through the tool, a friction force at the contact surface between the tube and the tool occurs From the recorded axial feeding forces, the friction coefficients between tube and die at the guide zone in tubular hydroforming can be estimated. The effects of the various internal pressures, viscosity of lubricants, tube materials, tube size and die coating on the friction forces and friction coefficients are discussed.

  • PDF

A Study on Discharge Characteristics of Spherically Convergent Beam Fusion Device (구형 집속 빔 핵융합 장치의 방전특성 연구)

  • Park, Jeong-Ho;Ju, Heung-Jin;Kim, Bong-Seok;Ko, Kwang-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1823-1825
    • /
    • 2004
  • Spherically convergent beam fusion device accelerate ions, which are generated between outer anode and inner grid cathode, toward the spherical center. The collision of opposite direction ions give rise to fusion reactions. Spherically convergent beam fusion device is very simple and compact, therefore the device has a potential that is applied to a portable neutron source. An experimental device consist of a 20cm-diameter spherical mesh-type anode and 7cm-diameter open spherical grid cathode and was maintained at a constant pressure of about 1333 Pa by feeding argon gas.

  • PDF