과도상태에서의 시스순환전류 저감장치 보호방안에 관한 연구 (A Study on the Protection Methods of Sheath Circulating Current Reduction Device in Transient State)

  • 강지원;정채균;이종범;이동일;정길조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.53-58
    • /
    • 2002
  • Sheath circulating current is increased as the change of sheath mutual impedance which is caused by imbalance of cable system, and different section length between joint box. If excessive current flows in sheath. sheath loss will be increased and then transmission capacity of underground transmission system is reduced. Accordingly, This paper proposed sheath current reduction device using resistor and reactor and proved the reduction effect of that device using EMTP/ATP. And also in this paper, when transients are occurred at the underground system with reduction device by ground fault and lightning surge. we analyzes transient effect of system variously. From this result. authors establish the protection methods of sheath circulating current reduction device.

  • PDF

일점접지방식을 이용한 전자교환기 방호의 실제 (Engineering Practice for ESS Protection by means of One Point Grounding System)

  • 김수형;서정욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.502-505
    • /
    • 1988
  • This paper is to demonstrate the effectiveness of one point grounding in support of ESS protection. One point grounding provides for the dispatching of excess energy for protection of switching equipment and personnel from lightning discharge hazards and for a natural sink for noise from atmospheric lightning and power transients. In most ESS installations there are a number of different items that must be maintained at a common ground potential for safety, fault protection or noise reduction. The items typically consist of power systems, heating and ventilating systems, distributing frames, repeating equipmets, switching equipments, etc. Grounding system of an ESS Office is most effective when all the ground points are connected to a single, common earth. The one point grounding prvides a common reference potential, keeping all the items of telecommunications facility free from the earth current and voltage hazards.

  • PDF

Development of STI/AOT Optimization Methodology and an Application to the AFWPs with Adverse Effects

  • You, Young-Woo;Yang, Hui-Chang;Chung, Chang-Hyun;Moosung Jae
    • Nuclear Engineering and Technology
    • /
    • 제29권3호
    • /
    • pp.211-217
    • /
    • 1997
  • Adverse effects caused by the surveillance test for the components of nuclear power plant involve plant transients, unnecessary wear, burden on licensee's time, and the radiation exposure to personnel along with the characteristics of each component. The optimization methodology of STI and AOT has been developed and applied to AFWPs of a reference plant. The approach proposed in this paper consist of the resole in minimal mean unavailability of the two-out-of-four system with adverse effects are analytically calculated for the example system. The surveillance testing strategy are given by the sequential test, the staggered test and the train staggered test which is a mined test scheme. In the system level, the sensitivity analyses for the STI and AOT, are performed for the measure of the system unavailability of the top event in the fault tree developed for the example system. This methodology may contribute to establishing the basis for the risk-based regulations.

  • PDF

EMTP 선로모델이 과전압 해석결과에 미치는 영향에 관한 연구 (A Study on the Effects of Line Constants Models for the Overvoltage Analysis in EMTP)

  • 김경탁;곽주식;권동진;구교선;우정욱
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.33-41
    • /
    • 2010
  • There are several overvoltages by abnormal conditions in power system. We need to calculate these ovevoltages for the insulation design and the fault analysis. For these calculations, we used EMTP(Electro-magnetic Transients Program). During EMTP calculations, the accurate modelling of the equipments is very important for analysis results. In this paper, we considered the effects of the modelling condition's changes for transmission line within EMTP modelling cases of overvoltage analysis. Specially, we considered CB closing cases of 765[kV] system. So, we had changed the calculation frequencies of Line Constants, which is used for CB closing cases. In addition, we compared the calculation result and the measured result.

전압, 전류 변화 추이를 이용한 전력용 변압기 보호계전 알고리즘 (A New Protective Relaying Algorithm for Power Transformer Based on Three Phase Voltage and Current)

  • 김상태;이승재;강상희;진보건;윤상현;이태성
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권4호
    • /
    • pp.157-165
    • /
    • 2001
  • The two criteria to identify the disturbances of the power transformer has been reported in this paper. They have been derived through EMTP simulations of internal faults, inrush and overexcitation for the model of 154/22.9[kV], 40[MVA], Y-Y three-phase power transformer. We propose the crisp algorithm which uses two criteria. A series of test results clearly indicate that the method can identify not only an internal fault but also the other transients. The average of relay operation times is about 7.2[ms]. The proposed algorithm immunes to the transient state.

  • PDF

RTDS를 이용한 Digital 거리계전기의 동특성 시험에 관한 연구 (Dynamic Characteristics of Digital Distance Relay Scheme Using Real Time Digital Simulator(RTDS))

  • 정창호;김일동;김영한;김석일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.109-111
    • /
    • 1996
  • This paper describes real time dynamic tests on the digital distance relay using new digital test system including RTDS(Real Time Digital Simulator) in KEPRI. The RTDS is developed by the Manitoba HVDC Reserch Centre and consists of specialized hardware and software which allows transients simulation of electrical power systems in real time. From high impedance fault test, it is known that the characteritics of distance reach is influenced by load flow. A detailed discussion of relay test using the RTDS simulator, high impedance faults and test results are included in the paper.

  • PDF

Positive Offset Mho 계자 상실 계전기 보호 협조 정정에 관한 연구 (A Study on Protective Coordination Setting of Positive Offset Mho Loss of Field Relay)

  • 김광현;박지경;김준혁;김두웅;강성범;김철환;유영식;양정재;고윤태
    • 전기학회논문지
    • /
    • 제65권8호
    • /
    • pp.1326-1333
    • /
    • 2016
  • It is important to clear the fault and prevent resulting in damage to power system. Although the frequency of generator internal fault is relatively low, it can lead to incalculable damage to power system as well as generator. Especially, loss of field on generator can cause the generator to lose synchronism for a short time if it is not removed promptly. Therefore, it is needed to conduct research on loss of field relay for detecting or clearing the loss of field. However, the setting of the relay may vary in generator operator or engineer, and the relay is not coordinated well with other elements associated with loss of field. In this paper, we address specifically the coordination of positive offset mho loss of field relay which is one of the protection schemes for loss of field. Computer simulations are performed by using ElectroMagnetic Transients Program-Restructured Version (EMTP-RV) based on actual data.

순간전압강하에 대한 동적전압보상기 (Dynamic Voltage Compensator for Voltage Sag)

  • 한병문;한경희;배정환;김희중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2047-2049
    • /
    • 1997
  • Computers and automatic equipment are very sensitive to the disturbances such as voltage transients, voltage sag, and harmonics. These disturbances cause them to have a malfunction or fault which brings about damages and losses. UPS (uninterruptible power supply) and SPS(stand-by power supply) have been used to provide the required voltage in a critical load without disturbances. However, UPS has appreciable losses due to the operation of the inverter in full rated power at all times. SPS, although whose inverter losses are smaller than those of UPS, transfers disturbances with a short duration to the load, due to the limited reaction time. In this research, a dynamic voltage compensator, which can make up for the weakness of UPS and SPS, is proposed. The operation of the proposed system was verified by a computer simulation. A hardware scaled-model was fabricated and tested to conform the feasibility of the actual system development.

  • PDF

Wavelet 변환을 이용한 voltage sag의 검출기법에 관한 연구 (A Study on the Detection Algorithm of Voltage Sag using Wavelet Transform)

  • 김철환;이종포;여상민;강윤식;강진수;채영무
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.276-278
    • /
    • 2001
  • In recent years, both electric utilities and end users have expressed their deep concerns about the quality of electric power. Especially, voltage sag which is one of power quality disturbance is very serious power quality problem on the power system. Voltage sag is a decrease to between 0.1 and 0.9 pu in rms voltage magnitude on the power system for durations from 0.5 cycles to 1 minute. These voltage sags are usually caused by fault conditions, overloads, and starting of large motors. The wavelet transform has attracted considerable attention in the field of power quality analysis recently. It has proved to be a powerful tool to study those transients that have time-localized information. In this paper, different types of voltage sags are simulated by using EMTP. This paper proposes the effective technique for voltage sag detection using wavelet transform.

  • PDF

On discrete nonlinear self-tuning control

  • Mohler, R.-R.;Rajkumar, V.;Zakrzewski, R.-R.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.1659-1663
    • /
    • 1991
  • A new control design methodology is presented here which is based on a nonlinear time-series reference model. It is indicated by highly nonlinear simulations that such designs successfully stabilize troublesome aircraft maneuvers undergoing large changes in angle of attack as well as large electric power transients due to line faults. In both applications, the nonlinear controller was significantly better than the corresponding linear adaptive controller. For the electric power network, a flexible a.c. transmission system (FACTS) with series capacitor power feedback control is studied. A bilinear auto-regressive moving average (BARMA) reference model is identified from system data and the feedback control manipulated according to a desired reference state. The control is optimized according to a predictive one-step quadratic performance index (J). A similar algorithm is derived for control of rapid changes in aircraft angle of attack over a normally unstable flight regime. In the latter case, however, a generalization of a bilinear time-series model reference includes quadratic and cubic terms in angle of attack. These applications are typical of the numerous plants for which nonlinear adaptive control has the potential to provide significant performance improvements. For aircraft control, significant maneuverability gains can provide safer transportation under large windshear disturbances as well as tactical advantages. For FACTS, there is the potential for significant increase in admissible electric power transmission over available transmission lines along with energy conservation. Electric power systems are inherently nonlinear for significant transient variations from synchronism such as may result for large fault disturbances. In such cases, traditional linear controllers may not stabilize the swing (in rotor angle) without inefficient energy wasting strategies to shed loads, etc. Fortunately, the advent of power electronics (e.g., high-speed thyristors) admits the possibility of adaptive control by means of FACTS. Line admittance manipulation seems to be an effective means to achieve stabilization and high efficiency for such FACTS. This results in parametric (or multiplicative) control of a highly nonlinear plant.

  • PDF