A Study on the Design of Control Logic for Wind Turbine Simulator having Similarity with 3MW Class Wind Turbine (3MW급 풍력터빈을 모사한 풍력터빈 시뮬레이터 제어로직 설계에 관한 연구)

  • Oh, Ki-Yong;Lee, Jae-Kyung;Park, Joon-Young;Lee, Jun-Shin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.810-816
    • /
    • 2012
  • As wind power has increased steadily, the importance of a condition monitoring system is being emphasized to maximize the availability and reliability of a wind turbine. To develop the advanced algorithms for fault detection and lifespan estimation, a wind turbine simulator is essential for verification of the proposed algorithms before applying them to a condition diagnosis & integrity prognosis system. The developed new-type simulator in this paper includes blades and various sensors as well as a motor, a gearbox and a generator of which the existing simulators generally consist. It also has similarity with a 3MW class wind turbine and can be used to acquire operational data from various operation conditions. This paper presents a design method of control logic for the wind turbine simulator, which gives a wind generation method and similar dynamic characteristics with the 3MW wind turbine. Finally, the proposed control logic is verified through experiments.

A Study on Degradation Pattern of GIS Using Clustering Methode (군집화 기법을 이용한 GIS 열화 패턴 연구)

  • Lee, Deok Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.4
    • /
    • pp.255-260
    • /
    • 2018
  • In recent years, increasing electricity use has led to considerable interest in green energy. In order to effectively supply, cut off, and operate an electric power system, many electric power facilities such as gas insulation switch (GIS), cable, and large substation facilities with higher densities are being developed to meet demand. However, because of the increased use of aging electric power facilities, safety problems are emerging. Electromagnetic wave and leakage current detection are mainly used as sensing methods to detect live-line partial discharges. Although electromagnetic sensors are excellent at providing an initial diagnosis and very reliable, it is difficult to precisely determine the fault point, while leakage current sensors require a connection to the ground line and are very vulnerable to line noise. The partial discharge characteristic in particular is accompanied by statistical irregularity, and it has been reported that proper statistical processing of data is very important. Therefore, in this paper, we present the results of analyzing ${\Phi}-q-n$ cluster distributions of partial discharge characteristics by using K-means clustering to develop an expert partial discharge diagnosis system generated in a GIS facility.

Condition Monitoring and Diagnosis of a Hot Strip Roughing Mill Using an Autoencoder (오토인코더를 이용한 열간 조압연설비 상태모니터링과 진단)

  • Seo, Myung Kyo;Yun, Won Young
    • Journal of Korean Society for Quality Management
    • /
    • v.47 no.1
    • /
    • pp.75-86
    • /
    • 2019
  • Purpose: It is essential for the steel industry to produce steel products without unexpected downtime to reduce costs and produce high quality products. A hot strip rolling mill consists of many mechanical and electrical units. In condition monitoring and diagnosis, various units could fail for unknown reasons. Methods: In this study, we propose an effective method to detect units with abnormal status early to minimize system downtime. The early warning problem with various units was first defined. An autoencoder was modeled to detect abnormal states. An application of the proposed method was also implemented in a simulated field-data analysis. Results: We can compare images of original data and reconstructed images, as well as visually identify differences between original and reconstruction images. We confirmed that normal and abnormal states can be distinguished by reconstruction error of autoencoder. Experimental results show the possibility of prediction due to the increase of reconstruction error from just before equipment failure. Conclusion: In this paper, hot strip roughing mill monitoring method using autoencoder is proposed and experiments are performed to study the benefit of the autoencoder.

Recent Research Trends of Process Monitoring Technology: State-of-the Art (공정 모니터링 기술의 최근 연구 동향)

  • Yoo, ChangKyoo;Choi, Sang Wook;Lee, In-Beum
    • Korean Chemical Engineering Research
    • /
    • v.46 no.2
    • /
    • pp.233-247
    • /
    • 2008
  • Process monitoring technology is able to detect the faults and the process changes which occur in a process unpredictably, which makes it possible to find the reasons of the faults and get rid of them, resulting in a stable process operation, high-quality product. Statistical process monitoring method based on data set has a main merit to be a tool which can easily supervise a process with the statistics and can be used in the analysis of process data if a high quality of data is given. Because a real process has the inherent characteristics of nonlinearity, non-Gaussianity, multiple operation modes, sensor faults and process changes, however, the conventional multivariate statistical process monitoring method results in inefficient results, the degradation of the supervision performances, or often unreliable monitoring results. Because the conventional methods are not easy to properly supervise the process due to their disadvantages, several advanced monitoring methods are developed recently. This review introduces the theories and application results of several remarkable monitoring methods, which are a nonlinear monitoring with kernel principle component analysis (KPCA), an adaptive model for process change, a mixture model for multiple operation modes and a sensor fault detection and reconstruction, in order to tackle the weak points of the conventional methods.

A Study on Development and Application of the Remote Driverless Vehicle Monitoring System by using Radio Communication (무선통신을 이용한 무인차량 원격감시설비 개발 및 적용에 관한 연구)

  • Choi, Jae-Ho;Lee, Jong-Sung;Lim, Chang-Hee
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.3073-3078
    • /
    • 2011
  • Driverless Train Control System has been recently introduced and commercialized in Korea. It is expected that the vehicle with driverless operation system will be used in new lines such as Sinbundang line soon. Therefore it is necessary to change the system operation and conception of the existing train operation system and the necessity of driverless vehicle monitoring system meeting a new paradigm is rising. In order to dispel concerning about safety issues caused by driverless train operation, the importance to establish vehicle error detection, useful fault diagnosis and rapid action plans is higher than ever. For this, efficient and higher level of vehicle supervision & control system should be essentially supported. In this study, remote driverless vehicle monitoring system using by radio communication is suggested to be used for monitoring and controlling important parts of the vehicle and diagnose and take quick actions when vehicles are in trouble at control tower at real time.

  • PDF

Implementation of Real-time Monitoring System for Marine Elevator using Smart Sensors (스마트 센서를 이용한 선박용 승강기 실시간 모니터링 시스템의 구현)

  • Lee, WooJin;Yim, JaeHong
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.2
    • /
    • pp.405-410
    • /
    • 2016
  • Elevator industry is a field that is mechanical, electrical and electronic technology and constantly requires inspection and maintenance considering various applications and various types. Recently, various elevator control and monitoring technologies with IT are developing for elevators on land. But technologies with IT have been hardly done in marine elevator that is consistently assured safety and reliability of life cycle for its parts in poor environment. In this paper, we implemented embedded main controller, floor controller and car controller that meet the requirements and use NMEA network protocol by analyzing home and abroad integrated elevator operation and management systems. Especially, we secured reliability of maintenance by real-time fault diagnosis and control that was implemented with limit switch, gyro sensor, temperature/humidity/barometric pressure sensor and fire detection sensor thinking over the environmental conditions of terrestrial and marine elevator.

Detection of Rotating Speed of Induction Motor Using the Rotor Slot Harmonic (회전자 슬롯 고조파를 이용한 유도전동기의 회전속도 검출)

  • Yang, Chul-Oh;Lee, Gyeong-Seok;Lee, Dae-Sung;Parkk, Kyu-Nam;Song, Myung-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2077-2078
    • /
    • 2011
  • Now a days, the induction motor is widely used in industry automation. Without monitoring the motor fault, maintenance cost is increased undesirably high. The slip frequency is included in the feature frequency, so rotating rotor speed is needed. In this paper, a sensorless motor speed estimation method, rotor slot harmonic(RSH) method is suggested and a solution of rotor bar diagnosis is proposed for motor running with light-load. When the rotor is rotating, it shows the harmonic signal of back-emf voltage related with number of rotor slot. So from the power spectrum of current signal, we can find the rotor speed.

  • PDF

Model Based Switch Open Fault Detection and Diagnosis for SPMSM (전압 오차를 이용한 인버터의 스위치 개방 고장 감지 및 진단)

  • Lim, Gyu Cheol;Choi, Young Hyun;Ha, Jung-Ik
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.103-104
    • /
    • 2017
  • 영구자석 전동기는 전력 밀도가 높고 효율이 좋은 특징으로 견인, 의료, 군사 분야 등 다양한 산업 분야에서 사용되고 있다. 이러한 분야에서 사용되는 전동기 구동 시스템은 높은 신뢰성이 요구되므로 인버터에서 발생하는 전력 반도체 스위치 고장을 빠르게 감지해야한다. 본 논문에서는 제어기 상전압 지령과 추정된 상전압 사이의 오차를 통해 전력 반도체 개방 고장을 감지하고 진단하는 방법을 제시하였다. 제안된 방법은 추가적인 측정 회로 없이 제어기 내부 값을 사용하여 개방 고장을 감지하고 개방된 스위치를 진단할 수 있다. 특히 부하 변동을 고려한 감지 방법을 제안하여 고장 감지의 신뢰성을 개선한다.

  • PDF

Topological Analysis of Chaos Characteristics in a Power System

  • Li, Shan-Ying;Lee, Sang-Seung;Park, Jong-Keun
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.1
    • /
    • pp.18-25
    • /
    • 2004
  • This paper proposes a totally new method in the chaos characteristics' analysis of power systems, the introduction of topological invariants. Using a return histogram, a bifurcation graph was drawn. As well, the periodic orbits and topological invariants - the local crossing number, relative rotation rates, and linking number during the process of period-doubling bifurcation and chaos were extracted. This study also examined the effect on the topological invariants when the sensitive parameters were varied. In addition, the topological invariants of a three-dimensional embedding of a strange attractor were extracted and the result was compared with those obtained from differential equations. This could be a new approach to state detection and fault diagnosis in dynamical systems.

A Study on The Diagnosis of Broken Rotor Bars in Three Phase Squirrel-Case Induction Motor (3상 농형 유도전동기 회전자 바의 고장진단에 관한 연구)

  • Kim, K.W.;Kwon, J.L.;Lee, K.J.;Kim, W.G.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.635-637
    • /
    • 2001
  • The faults of the squirrel cage induction motor is grew increasingly complex as the faults resulting in the shorting of a stator winding and the broken rotor bar or cracked rotor end ring, bearing faults, and so on. The users of electrical machines initially relied on simple protections such as over-current, over-voltage, earth-fault, etc. to ensure safe and reliable operation. but this method cause heavy financial losses and the threat of safety therefore it has now become very important to diagnose faults at there very inception. in this paper, we are going to discuss the detection method of broken rotor bar of squirrel cage induction motor by the motor current signal analysis(MCSA) and the opening terminal voltage signal analysis.

  • PDF