• 제목/요약/키워드: fault current limiter(FCL)

검색결과 76건 처리시간 0.029초

DESIRABLE PARAMETER IDENTIFICATION FOR THE IMPLEMENTATION OF IDEAL PASSIVE FAULT CURRENT LIMITER FOR THE PROTECTION OF POWER SEMICONDUCTOR DEVICES

  • Mukhopadhyay, S.C.;Iwahara, M.;Yamada, S.;Dawson, F.P.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.859-864
    • /
    • 1998
  • Compact and small size, reliable and failsafe operation and low cost featuring fault current limiter causing the designer to take a close look into the use of passive fault current limiter(FCL) for the protection of power semiconductor devices in power electronic systems. This paper has identified the main parameters responsible for the development of ideal passive magnetic current limiter. The effect of those parameters on the range of operation and the voltage-current characteristics of the magnetic current limiter has been studied using tableau approach. Desirable characteristics are discussed and the simulation results are presented.

  • PDF

스마트 그리드 배전계통을 위한 직렬 공진형 한류기 적용 방법 및 EMTP-RV 시뮬레이션 연구 (Application Method and EMTP-RV Simulation of Series Resonance Type Fault Current Limiter for Smart Grid based Electrical Power Distribution System)

  • 고윤석;이우철
    • 한국전자통신학회논문지
    • /
    • 제19권2호
    • /
    • pp.361-370
    • /
    • 2024
  • 본 논문에서는 저비용 제작이 가능한 직렬 공진형 한류기를 스마트 그리드 배전 계통에 적용하기 위한 방법을 연구하였다. 먼저, 한류기의 직렬 공진 회로에 주입되는 단락 전류의 고조파 성분들이 과도 응답의 피크 값에 미치는 영향에 대해서 분석하였으며, 퍼센트 임피던스 기반 고장 전류 계산법을 적용하여 정상 상태 응답을 결정하는 방법을 연구하였다. 다음, 시험 배전 선로에 적용하여 채택된 방법의 유효성을 검증하였다. 설계된 한류기를 적용한 시험 배전계통을 EMTP_RV를 이용하여 모델링하였으며 3상 단락 고장 시나리오를 모의하였다. 고장 모의 결과에서 한류기 적용 후 고장 전류의 정상 상태 응답이 설계 목표 값을 정확하게 추종하는 것을 확인하였다. 또한 한류기 적용 전과 후의 고장전류 파형 비교에서 고장 전류가 크게 억제되는 것을 확인함으로써 배전 계통에 대한 직렬 공진형 한류기 적용 효과를 확인할 수 있었다.

저항형 초전도 한류기를 위한 배전개통의 모델링과 적용 (Distribution System modeling and Application for HTS Resistor type FCL)

  • 최흥관;윤재영;김종율;이병준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.250-252
    • /
    • 2002
  • Nowadays, one of the serious Problems in KEPCO system is the more higher fault current than the SCC(Short Circuit Capacity) of circuit breaker. There are many alternatives to reduce the increased fault current. As the superconductivity technology has been develops, the HTS-FCL(High Temperature Superconductor-Fault Current Limiter) can be a one of the attractive alternatives to solve the fault current problem. Under the this background, this paper presents distribution system EMTDC modeling and the application of EMTDC model for resistance type HTS-FCL in the developed distribution system model.

  • PDF

수용가계통에서의 초전도한류기 적용가능성 검토 (A study on the application of HTS-FCL in Customer System)

  • 이승렬;김종율;윤재영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.427-429
    • /
    • 2004
  • As the load density of KEOCO system is higher, the fault current can be much higher than SCC(Short Circuit Capacity) of circuit breaker. Even though there are several alternatives to reduce fault current, as the superconductivity technology has been developed, the HTS-FCL (High Temperature Superconductivity Fault Current Limiter) can be one of the attractive alternatives to solve the fault current problem. This study presents the application of HTS-FCL in real customer system.

  • PDF

변압기 권선비의 변화에 따른 3상 DC 리액터형태 한류기의 단락실험 (Short Circuit Tests of the Three-Phase DC Reactor Type Fault Current Limiter in Changing of Turns Ratio of Transformers)

  • 이응로;이찬주;이승제;고태국;현옥배
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권6호
    • /
    • pp.267-272
    • /
    • 2002
  • This Paper deals with the short circuit tests of the three-Phase DC reactor type fault current limiter (FCL) in changing of turns ratio of transformers. The experiment of this paper is a preliminary step to develop the FCL's faculties for an application to high voltage transmission line. So, superconducting coil was made of Nb-Ti, low temperature superconductor, and the ratings of the power system of experimental circuit are 400V/7A class. A three-phase DC reactor type FCL consists of three transformers, six diodes, one superconducting coil and one cryostat. The important point of experimental analysis is transient period, the operating lagging time of circuit breaker. As the results of the experiment, the values are referred to the limitation rate about 77% and 90% when the turns ratio of transformer was 1:1 and 2:1 respectively.

Modeling and Simulation using Simulink and SimPowerSystem of optimized HTS FCL location in a Smart Grid having a Wind Turbine connected with the grid

  • Khan, Umer-Amir;Lee, Sang-Hwa;Seong, Jae-Kyu;Lee, Bang-Wook
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권2호
    • /
    • pp.17-20
    • /
    • 2010
  • A considerable amount of research material discussing designs and properties of High Temperature Superconducting Fault Current Limiter (HTS FCL) is available. However, a shortage of research concerning positioning of HTS FCL in power grid is felt. In this paper a feasibility study of HTS FCL positioning in Smart Grid through simulation analysis is carried out. A complete power network (including generation, transmission and distribution) is modeled in Simulink / SimPowerSystems. A generalized HTS FCL is also designed by integrating Simulink and SimPowerSystem blocks. The distribution network of the model has a wind turbine attached to it forming a micro grid. Three phase fault have been simulated along with placing FCL models at key points of the distribution grid. It is observed that distribution grid, having distributed generation sources attached to it, must not have a single FCL located at the substation level. Optimized HTS FCL location regarding the best fault current contribution from wind turbine has been determined through simulation analysis.

실계통에서의 154kV HTS-FCL Bus-Tie 최적 적용방안에 관한 연구 (A Study on the Bus-Tie Application of 154kV HTS-FCL in Korean Power System)

  • 김종율;윤재영;이승열
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권5호
    • /
    • pp.226-233
    • /
    • 2005
  • As the power demand has been increasing, a fault current problem is becoming more serious in real power system. Various ways like bus-split operation, transmission line open operation, are used in Korean power system for solving the problem. In this time, superconducting FCL(Fault Current Limiter) has been developed as a vary attractive alternative since HTS(High Temperature Superconductivity) was discovered. Korea, a project developing superconducting FCL to apply to 154kV transmission system is proceeding. Therefore, a power system analysis for SFCL application to power system is necessary, This paper presents the determination of quenching resistance and the selection of optimal cites when 154kV HTS-FCL is applied to Korean power system.

22.9kV 지중선로용 한류기 한전 실계통 시범적용 (Application of Fault Current Limiter in 22.9kV KEPCO power distribution line)

  • 김민지;박경원;안길영;김영근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1034-1035
    • /
    • 2015
  • Watertight 25.8 kV/600 A/12.5 kA fault current limiters (FCLs) have successfully installed in five areas (Incheon, Seoul, Gyeong-gi, Daejeon, Suwon) on KEPCO power distribution line for the purpose of commercial demonstrations. The fault current limiting operation of this FCL, which includes functions of sensing, commutation, and reduction of fault currents, is perfectly completed within 1 cycle immediately after fault occurs. The performance of FCL was verified by short circuit test, impedance test, insulation test, temperature-rise test, and control test, etc at PT&T in LS industrial systems, which is the official certification institute in Korea. In 2013, and also the FCL field test was performed in order to test the protection coordination between conventional relays and FCL, on the 1.5 kA and 5.0 kA faults, which were made by connecting the Artificial Fault Generator (AFG) to the distribution line in test grid at KEPCO Power Testing Center. The next step of this project is to check the FCL conditions caused by real external environment, and acquire the various data from five regions installed with FCL. In this paper, we intend to explain the FCL specifications and performance characteristics, and check the expected effect by application of FCL to power distribution line based on the power system analysis of an application site.

  • PDF

EMTDC Modeling Method of DC Reactor type Superconducting Fault Current Limiter

  • Lee, Jaedeuk;Park, Minwon;Yu, In-Keun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권1호
    • /
    • pp.56-59
    • /
    • 2003
  • As electric power systems grow to supply the increasing electric power demand short-circuit current tends to increase and impose a severe burden on circuit breakers and power system apparatuses. Thus, all electric equipment in a power system has to he designed to withstand the mechanical and thermal stresses of potential short-circuit currents. Among current limiting devices, Fault Current Limiter (FCL) is expected to reduce the short-circuit current. Especially, Superconducting Fault Current Limiters (SFCL) offer ideal performance: in normal operation the SFCL is in its superconducting state and has negligible impedance, in the event of a fault, the transition into the normal conducting state passively limits the current. The SFCL using high-temperature superconductors offers a positive resolution to controlling fault-current levels on utility distribution and transmission networks. This study contributes to the EMTDC based modeling and simulation method of DC Reactor type SFCL. Single and three phase faults in the utility system with DC reactor type SFCLs have been simulated using EMTDC in order to coordinate with other equipments, and the results are discussed in detail.

Modified DC 리액터 타입 고온초전도전류제한기 동작특성 (The Operational Characteristic of Modified DC Reactor Type HTSC Fault Current Limiter)

  • 황종선;김영민;최효상;최창주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집
    • /
    • pp.57-60
    • /
    • 2004
  • 본 논문은 전원단과 부하단사이에 GTO 사이리스터 브리지가 설치된 단상 DC 리액터타입을 적용한 고온초전도 사고전류제한기 동작특성에 대해 분석하였다. GTO 사이리스터 브리지가 설치된 DC 리액터 타입 FCL(Fault Current Limiter)은 평상시에 초전도코일에 전기에너지를 저장한다. 전원단의 사고로 인해 전력 공급이 중단되었을 경우 FCL은 부하에 저장된 에너지를 공급할 수 있을 뿐 아니라 부하단 사고로 인한 사고전류 제한기능을 수행하게 되는데 이와 같은 동작은 GTO 사이리스터를 제어함으로서 가능해진다.

  • PDF