• Title/Summary/Keyword: fault contact

Search Result 142, Processing Time 0.03 seconds

Analysis of Fire Accident on Power Line for DC Electric Traction Vehicles (전기철도 전원계통에서의 화재사고 사례 분석)

  • Song, Jae-Yong;Cho, Young-Jin;Nam, Jung-Woo;Kim, Jin-Pyo;Park, Nam-Kyu
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.2
    • /
    • pp.18-23
    • /
    • 2010
  • This paper describes a cause of fire accidents on power system fire DC electric traction vehicles. We investigated fire scene of power line for DC electric traction vehicles. From analysis results, the cause of fire on power line turned out line to ground fault between a feeder of electric power services(pantagraph) and DC electric traction vehicle roof. Fire accident of DC electric traction vehicles be assumed that electric sparks had been produced between the pantagraph and the power line conductor by repetitively making contact and separation, maybe if some material like branches get in between connecting rod it makes progress line to ground fault. ZnO arresters are widely used to protect DC electric traction vehicles against overvoltages caused by lightning or switching surges. However, the arresters are deteriorated by commercial overvoltages and/or lightning one. The deteriorated arresters could lead power failures, such as line to ground fault by a thermal runaway resulting from the increases in leakage current even in a nominal power system voltage. Finally, the power failures would be causative of the fire accident.

Analysis of Fire Accidents on Power Line for DC Electric Traction Vehicles (전기철도 전원계통에서의 화재 사고사례 분석)

  • Song, Jae-Yong;Cho, Young-Jin;Kim, Jin-Pyo;Park, Nam-Kyu;Kil, Gyung-Suk
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.241-247
    • /
    • 2008
  • This paper describes a cause of fire accidents on power system for DC electric traction vehicles. We investigated fire scene of power line for DC electric traction vehicles. From analysis results, the cause of fire on power line turned out line to ground fault between a feeder of electric power services(pantagraph) and DC electric traction vehicle roof. Fire accidents of DC electric traction vehicles be assumed that electric sparks had been produced between the pantagraph and the power line conductor by repetitively making contact and separation, maybe if some material like branches get in between connecting rod it make progress line to ground fault. ZnO arresters are widely used to protect DC electric traction vehicles against overvoltages caused by lightning or switching surges. However, the arresters are deteriorated by commercial frequency overvoltages and/or lightning one. Deteriorated arresters could lead power failures, such as line to ground fault by a thermal runaway resulting from the increases in leakage current even in a nominal power system voltage. The power failures, such as line to ground fault would be causative of the fire accidents.

  • PDF

Study on the Electrical Insulation of Current Lead in the conduction-cooled 1-2kV Class High-Tc Superconducting DC Reactor (전도냉각되는 1-2kV급 고온초전도 직류리액터 전류도입부의 전기적 절연에 대한 연구)

  • 배덕권;안민철;이찬주;정종만;고태국;김상현
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.30-34
    • /
    • 2002
  • In this Paper, Insulation of current lead in the conduction-cooled DC reactor for the 1.2kV class 3 high-Tc superconducting fault current limiter(SFCL) is studied. Thermal link which conducts heat energy but insulates electrical energy is selected as a insulating device for the current lead in the conduction-cooled Superconducting DC reactor. It consists of oxide free copper(OFC) sheets, Polyimide films, glass fiberglass reinforced Plastics (GFRP) plates and interfacing material such an indium or thermal compound. Through the test of dielectric strength in L$N_2$, polyimide film thickness of 125 ${\mu}{\textrm}{m}$ is selected as a insulating material. Electrical insulation and heat conduction are contrary to each other. Because of low heat conductivity of insulator and contact area between electrical insulator and heat conductor, thermal resistance of conduction-cooled system is increased. For the reducing of thermal resistance and the reliable contact between Polyimide and OFC, thermal compound or indium can be used As thermal compound layer is weak layer in electrical field, indium is finally selected for the reducing of thermal resistance. Thermal link is successfully passed the test. The testing voltage was AC 2.5kVrms and the testing time was 1 hour.

Laboratory Study of the Shear Characteristics of Fault Gouges Around Mt. Gumjung, Busan (부산 금정산일대에 분포하는 단층비지의 전단특성에 관한 실험적 고찰)

  • Woo, Ik
    • The Journal of Engineering Geology
    • /
    • v.22 no.1
    • /
    • pp.113-121
    • /
    • 2012
  • The mechanical characteristics of a fault gouge from near Mt. Kumjung in Kumjung-Gu, Busan, were estimated from laboratory tests on different joint models. Fault gouge samples and joint samples in biotite granite were obtained from boreholes in the study area that had penetrated small faults associated with the Dongnae and Yangsan faults. XRD and SEM analyses revealed that for the fault gouge consists of several clay minerals with tabular structure (kaolinite, montmorillonite, illite, sericite), which could cause the considerable reduction of shear strength when wet. The shear strength of the fault gouge was obtained from direct shear tests of the fault gouge itself and from direct shear tests of several natural/artificial joint surfaces coated with fault gouge. The results indicate that the reduction of shear strength is more abrupt for the joint surfaces coated with fault gouge compared with uncoated joint surfaces, and that the friction angle of the fault gouge between joint surfaces is much lower than the internal friction angle of the fault gouge itself. Fault gouges in contact with rock, therefore, could have a stronger negative effect on the stability of structures in rock masses than the fault gouge itself.

Seismic surface waves in a pre-stressed imperfectly bonded covered half-space

  • Negin, Masoud
    • Geomechanics and Engineering
    • /
    • v.16 no.1
    • /
    • pp.11-19
    • /
    • 2018
  • Propagation of the generalized Rayleigh waves in an elastic half-space covered by an elastic layer for different initial stress combinations and imperfect contact conditions is investigated. Three-dimensional linearized theory of elastic waves in initially stressed bodies in plane-strain state is employed, the corresponding dispersion equation is derived and an algorithm is developed for numerical solution to this equation. Numerical results on the influence of the initial stress patterns and on the influence of the contact conditions are presented and discussed. The case where the external forces are "follower forces" is considered as well. These investigations provide some theoretical foundations for the study of the near-surface waves propagating in layered mechanical systems and can be successfully used for estimation of the degree of the bonded defects between layers, fault characteristics and study of the behavior of seismic surface waves propagating under the bottom of the oceans.

A Numerical Study on Temperature Fields in MCCB (MCCB 내의 온도장에 대한 수치적 연구)

  • Park, S.K.;Lee, Jong-Chul;Kim, Youn-J.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.145-150
    • /
    • 2003
  • In this paper we have studied the characteristics of temperature fields in a Molded Case Circuit Breaker (MCCB). A switch and a trip device are arranged in narrow space of the MCCB. Thus, thermal factors have been risen to important problem. The temperature rise means an energy loss and it becomes the reason of fatal fault in devices. Also, the temperature rise on the connection and the contact parts is regulated up to $115^{\circ}C$ and $105^{\circ}C$, respectively. Therefore, a study for preventing the temperature rise should be investigated. A numerical analysis method that has confidence might be preceded for this purpose. In order to verify the confidence of temperature field analysis, the results of the numerical analysis are compared with those of experimental one for the same model. Comparison results show a qualitatively good agreement within ${\pm}5%$ errors.

  • PDF

A Study on Fault Prediction Algorithm and Failure Instance Analysis of Electric Power Relay (전력릴레이 고장사고 사례분석 및 고장예측 알고리즘 연구)

  • Kim, Yong-Kyu;Kwak, Dong-Kurl;Lee, Seung-Chul
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.15-16
    • /
    • 2015
  • According to 2014 fire statistical yearbook in the National Fire Data System, a main cause of fire is electrical fire except carelessness fire. Joint/contact badness is the one of the main cause of electrical fire. Furthermore, power relays which are used in electric panel board, motor control center and automation controller, are main element of automation system in the industry field. Overload, voltage unbalance and open-phase due to joint/contact badness of terminal make electric accidents or electrical fires. In order to prevent joint/contact badness of terminal, this paper proposes a sensing circuit of chattering, tracking, arc current, voltage unbalance and open-phase etc. Some experimental tests of the proposed apparatus confirm practicality and validity of the theoretical results.

  • PDF

Effect of Deformation Properties at the Contact Surfaces on the Wear Rate (접촉면에서의 변형특성이 마멸속도에 미치는 영향)

  • 이영호;김인섭
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.115-121
    • /
    • 2001
  • The wear test has been performed to evaluate the wear mechanism of steam generator (SG) tube materials against ferritic stainless steel in water environment. The wear rates of SG tube materials depend on the change of mechanical properties between contact surfaces during wear test. From the subsurface hardness test, Inconel 690 is more work-hardened than Inconel 600 even though these materials have similar hardness values before the wear test. Main cause is due to the difference of stacking fault energy with the chromium content. In water environment, wear mechanism is closely related with the continuous formation and fracture of deformation layers at the contact surfaces.

  • PDF

Improvement of Short Circuit Performance in 460[V]/400{A]/85(kA] Molded Case Circuit Breakers (460[V]/400[A]/85[kA] 배선용 차단기의 아크런너 변형을 통한 차단성능 향상)

  • Lee, Seung-Su;Her, June;Yoon, Jae-Hun;Kang, Seong-Hwa;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.394-394
    • /
    • 2009
  • Owing to the increasing number of intelligent homes(or called Smart home), the corresponding cost is much higher. Low voltage circuit breakers are widely used in the intelligent homes to interrupt fault current rapidly and to assure the reliability of the power supply. The distribution of magnetic field induced by arc current in the contact system of molded case circuit breaker(hereafter MCCB) depends on the shape, arrangement, and kinds of material of arc runner. This paper is focused on understanding the interrupting capability, more specifically of the arc runner, based on the shape of the contact system in the current MCCB. The magnetic driving force was calculated by using the flux densities induced by the arc current, which are obtained by three-dimensional finite element method. There is a need to assure that the optimum design required to analyze the electromagnetic forces of the contact system generated by current and the flux density be present. This is paper present our computational analysis on contact system in MCCB.

  • PDF

Formation of Alteration Minerals in Gouges of Quaternary Faults at the Eastern Blocks of the Ulsan Fault, Southeastern Korea (울산단층 동부지역 제4기단층 비지대내 변질광물의 형성)

  • Chang, Tae-Woo;Chae, Yeon-Joon;Choo, Chang-Oh
    • Journal of the Mineralogical Society of Korea
    • /
    • v.18 no.3 s.45
    • /
    • pp.205-214
    • /
    • 2005
  • Some Quaternary faults developed in the eastern block of the Ulsan fault are Gaegok 1, Gaegok 2, Singye, Madong, Wonwonsa and Jinhyeon faults, which are characterized by thin gouge and narrow cataclasitic tones. This study was performed to emphasize the role of mineral alteration and microtexture in response to hydrothermal alteration of fault gouges during fault activity, using XRD, EPMA, BSE (backscattered electron image), and K-Ar age dating methods. Alteration minerals in fault gouges were formed in the age range of $44.3\~28.9Ma$ by hydrothermal alteration attributed to fault activity. XRD results show that fault gouges consist predominantly of clay minerals, quartz and feldspars. Clay minerals formed in the gouge zones are mainly composed of smectite with trace chlorite, illite and kaolinite. The evidence to support the hydrothermal alteration of preexisting minerals due to fault activity are easily recognized at the host rocks in contact with gouges zones. Injected gouge and calcite veins indicate that they were originated from multiple deformation by repeated fault activity. Gouge with green or greenish grey color, for example Jinhyeon fault, contains higher $Al_2O_3$ and lower MgO and CaO compared to those with reddish color. Various colors of fault gouge are intimately related to the chemical compositions of main constituent mineral as well as mineral assemblage.