• 제목/요약/키워드: fastener

검색결과 195건 처리시간 0.026초

Structural behavior of the stiffened double-skin profiled composite walls under compression

  • Qin, Ying;Li, Yong-Wei;Lan, Xu-Zhao;Su, Yu-Sen;Wang, Xiang-Yu;Wu, Yuan-De
    • Steel and Composite Structures
    • /
    • 제31권1호
    • /
    • pp.1-12
    • /
    • 2019
  • Steel-concrete composite walls have been proposed and developed for applications in various types of structures. The double-skin profiled composite walls, as a natural development of composite flooring, provide structural and architectural merits. However, adequate intermediate fasteners between profiled steel plates and concrete core are required to fully mobilize the composite action and to improve the structural behavior of the wall. In this research, two new types of fasteners (i.e., threaded rods and vertical plates) were proposed and three specimens with different fastener types or fastener arrangements were tested under axial compression. The experimental results were evaluated in terms of failure modes, axial load versus axial displacement response, strength index, ductility index, and load-strain relationship. It was found that specimen with symmetrically arranged thread rods sustained more stable axial strain than that with staggered arranged threaded rods. Meanwhile, vertical plates are more suitable for practical use since they provide stronger confinement to profiled steel plate and effectively prevent the steel plate from early local buckling, which eventually enhance the composite action and increase the axial compressive capacity of the wall. The calculation methods were then proposed and good agreement was observed between the test results and the predicted results.

Experimental and numerical study of an innovative 4-channels cold-formed steel built-up column under axial compression

  • G, Beulah Gnana Ananthi;Roy, Krishanu;Lim, James B.P.
    • Steel and Composite Structures
    • /
    • 제42권4호
    • /
    • pp.513-538
    • /
    • 2022
  • This paper reports on experiments addressing the buckling and collapse behavior of an innovative built-up cold-formed steel (CFS) columns. The built-up column consists of four individual CFS lipped channels, two of them placed back-to-back at the web using two self-drilling screw fasteners at specified spacing along the column length, while the other two channels were connected flange-to-flange using one self-drilling screw fastener at specified spacing along the column length. In total, 12 experimental tests are reported, covering a wide range of column lengths from stub to slender columns. The initial geometric imperfections and material properties were determined for all test specimens. The effect of screw spacing, load-versus axial shortening behaviour and buckling modes for different lengths and screw spacing were investigated. Nonlinear finite element (FE) models were also developed, which included material nonlinearities and initial geometric imperfections. The FE models were validated against the experimental results, both in terms of axial capacity and failure modes of built-up CFS columns. Furthermore, using the validated FE models, a parametric study was conducted which comprises 324 models to investigate the effect of screw fastener spacing, thicknesses and wide range of lengths on axial capacity of back-to-back and flange-to-flange built-up CFS channel sections. Using both the experimental and FE results, it is shown that design in accordance with the American Iron and Steel Institute (AISI) and Australia/New Zealand (AS/NZS) standards is slightly conservative by 6% on average, while determining the axial capacity of back-to-back and flange-to-flange built-up CFS channel sections.

컴프레서 체결용 볼트의 적정 토크 설정에 관한 연구 (A Study on Setting of Torque for Compressor Jointing Bolt)

  • 공유식;김태완
    • Tribology and Lubricants
    • /
    • 제29권5호
    • /
    • pp.286-290
    • /
    • 2013
  • When a threaded fastener is tightened, the torque-tension relationship is highly sensitive to two friction components: thread friction and head friction. In this study, we carried out friction experiments and analyses to determine the optimum clamping torque setting for bolt joints. First, we measured the coefficients of thread friction and head friction under the same running conditions of the bolt clamping process for lubricated and non-lubricated bolts. We also measured axial tension through bolt clamping tests using lubricated and non-lubricated bolts attached to a strain gauge. Finally, we compared the experiment and theoretical results.

저장매체용 스크류의 냉간 헤딩 공정 설계에 대한 연구 (Design of Cold Heading Process of a Screw for Storage Parts)

  • 서원상;민병욱;박근;나승우;이상훈;김종호;김종봉
    • 소성∙가공
    • /
    • 제20권1호
    • /
    • pp.48-53
    • /
    • 2011
  • Fasteners are used to join the various electronic products and machines. So, the quality and reliability of the fastener are strongly requested. In this study, the analyses of the multi-stage cold forging of TORX screws for storage parts are carried out. In manufacturing of TORX screws, crack and folding defects are observed. Therefore, the analysis is focused on the prediction of the defects. Based on the analysis results, the upper die and process conditions are redesigned to reduce the defects. The upper die shape for preform forming is redesigned to prevent folding and sharp shape change. The Cockroft-Latham damage criterion is introduced to predict the crack initiation. Analysis results shows that the maximum Cockroft-Latham damage value is decreased by 40% in the forming using the modified upper die.

TC볼트의 스트리핑 메카니즘에 대한 실험적 연구 (Experimental study on stripping mechanism of tension controlled bolts)

  • 신근하
    • 한국생산제조학회지
    • /
    • 제9권1호
    • /
    • pp.111-118
    • /
    • 2000
  • Over tightening experiments of the tension-controlled bolts are carried out and the stripping mechanism is reviewed base on the observed results. There are two modes of bolt failure due to the over tightening : one the fracture of the bolt the other the thread stripping Bifurcation between these two modes is rather delicate but it seems being related with the elastic flexibility of the bolt which depends upon the unused thread length. The fracture mode occurs in the bolts with good flexibility while the latter with bad one. According to the ISO Standard some meter coarse threads like M20 and M22 have the same pitch which causes bigger fastener to less resistance in shear and bending compared with the smaller one. however since UNC thread system adapts different pitch for different nominal diameter unified coarse threads show better stripping resistance than their corresponding meter threads.

  • PDF

온도에 의한 궤도의 후좌굴 거동 (Post-Buckling Behavior of the Track due to Temperature)

  • 임남형;이지하;강윤석;양신추
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(II)
    • /
    • pp.442-447
    • /
    • 2003
  • The actual behavior of the railroad track structure is suspected to be a complex interaction between the vertical, lateral, longitudinal, and torsional behaviors. A FE program are developed in the present study to be used for extensive nonlinear analysis of the track structures subjected to thermal load. Using the rigorous study on the deformed shape of the rail and tie, and stress resultants, characteristics of the three dimensional behavior are investigated. It is found that the flexural rigidity of the tie and the rotational stiffness of pad-fastener can be affect the behavior of the track structure and the postbuckling behavior in each rail, except lateral behavior, is not same.

  • PDF

궤도노반의 상태 및 품질평가에 관한 연구 (Evaluation on the condition and quality of railway track substructure)

  • 김대상;박태순
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.346-353
    • /
    • 2005
  • Track substructure(ballast, subgrade) should have sufficient strength and adequate stiffness to fully support track superstructure(rail, fastener, sleeper). Vertical support stiffness of track comes from the sufficient thickness, adequate strength and stiffness of material of substructure layers. Since the vertical support stiffness of track substructure is closely related with the track geometry, the evaluation of the stiffness is very important to understand the track states. This paper introduces the system, which are composed of Ground Penetrating Radar(GPR), Portable Ballast Sampler(PBS), and Light Falling Weight Deflectometer(LFWD), to evaluate substructure condition and summarizes the field test results performed with the reliable system.

  • PDF

홀확장법과 억지끼워맞춤의 잔류응력 비교를 위한 유한요소해석 (The Finite Element Analysis for Comparision of Residual Stress at Cold Expansion Method and Interfernce Fit)

  • 장재순;양원호;김철;고명훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.419-424
    • /
    • 2001
  • The purpose of this study is comparing cold expansion method with interference fit. Cold expansion method and interference fit of fastener hole is using in the aerospace industry. These treatment lead to an improvement of fatigue life to the compressive residual stresses developed on the hole surface. But Research is nothing to about difference effect of between cold expansion method and interference fit. So In this paper, It is shown that Comparing cold expansion method with interference fit. and It is further shown that residual stress distribution according to plate thickness.

  • PDF

밀도분포법을 이용한 부재의 연결구조 최적화 (Topology Optimization of Connection Component System Using Density Distribution Method)

  • 한석영;유재원
    • 한국공작기계학회논문집
    • /
    • 제12권4호
    • /
    • pp.50-56
    • /
    • 2003
  • Most engineering products contain more than one component. Failure occurs either at the connection itself or in the component at the point of attachment of the connection in many engineering structures. The allocation and design of connections such as bolts, spot-welds, adhesive etc. usually play an important role in the structure of multi-components. Topology optimization of connection component provides more practical solution in design of multi-component connection system. In this study, a topology optimization based on density distribution approach has been applied to optimal location of fasteners such as T-shape, L-shape and multi-component connection system. From the results, it was verified that the number of iteration was reduced, and the optimal topology was obtained very similarly comparing with ESO method. Therefore, it can be concluded that the density distribution method is very suitable for topology optimization of multi-component structures.

밀도분포법을 이용한 부재의 연결구조 최적화 (Topology Design of Connection Component System Using Density Distribution Method)

  • 한석영;유재원;박재용
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 춘계학술대회 논문집
    • /
    • pp.15-20
    • /
    • 2003
  • Most engineering products contain more than one component. Failure occurs either at the connection itself or in the component at the point of attachment of the connection in many engineering structures. The allocation and design of connections such as bolts, spot-welds, adhesive etc. usually play an important role in the structure of multi-components. Topology optimization of connection component provides more practical solution in design of multi-component connection system. In this study, a topology optimization based on density distribution approach has been applied to optimal location of fasteners such as T-shape, L-shape and multi-component connection system. From the results, it was verified that the number of iteration was reduced, and the optimal topology was obtained very similarly comparing with ESO method. Therefore, it can be concluded that the density distribution method is very suitable for topology optimization of multi-component structures.

  • PDF