• Title/Summary/Keyword: fast-release

Search Result 169, Processing Time 0.024 seconds

A Study on Development Cost Attributes Analysis of NHPP Software Reliability Model Based on Rayleigh Distribution and Inverse Rayleigh Distribution (레일리 분포와 역-레일리 분포에 근거한 NHPP 소프트웨어 신뢰성 모형의 개발비용 속성 분석에 관한 연구)

  • Yang, Tae-Jin
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.6
    • /
    • pp.554-560
    • /
    • 2019
  • In this study, after applying the finite failure NHPP Rayleigh distribution model and NHPP Inverse Rayleigh distribution model which are widely used in the field of software reliability to the software development cost model, the attributes of development cost and optimal release time were compared and analyzed. To analyze the attributes of software development cost, software failure time data was used, parametric estimation was applied to the maximum likelihood estimation method, and nonlinear equations were calculated using the bisection method. As a result, it was confirmed that Rayleigh model is relatively superior to Inverse Rayleigh model because software development cost is relatively low and software release time is also fast. Through this study, the development cost attributes of the Rayleigh model and the Inverse Rayleigh model without the existing research examples were newly analyzed. In addition, we expect that software developers will be able to use this study as a basic guideline for exploring software reliability improvement method and development cost attributes.

Focal Muscle Vibration Changes the Architecture of the Medial Gastrocnemius Muscle in Persons With Limited Ankle Dorsiflexion

  • Moon, Il-Young;Lim, Jin-Seok;Park, Il-Woo;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.29 no.1
    • /
    • pp.48-53
    • /
    • 2022
  • Background: The gastrocnemius tightness can easily occur. Gastrocnemius tightness results in gait disturbance. Thus, various interventions have been used to release a tight gastrocnemius muscle and improve gait performance. Moreover, focal muscle vibration (FMV) has recently been extensively researched in terms of tight muscle release and muscle performance. However, no study has investigated the effects of FMV application on medial gastrocnemius architectural changes. Objects: In this study, we aimed to investigate the effects of FMV on medial gastrocnemius architecture in persons with limited ankle dorsiflexion. Methods: Thirty one persons with <10° of passive ankle dorsiflexion participated in this study. We excluded persons with acute ankle injury within six months prior to study onset, a history of ankle fracture, leg length discrepancy greater than 2 cm, no history of neurological dysfunction, or trauma affecting the lower limb. The specifications of the FMV motor were as follows: a fixed frequency (fast wave: 150 Hz) and low amplitude (0.3-0.5 mm peak to peak) of vibration; the motor was used to release the medial gastrocnemius for 15 minutes. Each participant completed three trials for 10 days; a 30-second rest period was provided between each trial. Medial gastrocnemius architectural parameters [muscle thickness (MT), fiber bundle length (FBL), and pennation angle (PA)] were measured via ultrasonography. Results: MT significantly decreased after FMV application (p < 0.05). FBL significantly increased from its baseline value after FMV application (p < 0.05). PA significantly decreased from its baseline value after FMV application (p < 0.05). Conclusion: FMV application may be advantageous in reducing medial gastrocnemius excitability following a decrease in the amount of contractile tissue. Furthermore, FMV application can be used as a stretching method to alter medial gastrocnemius architecture.

Study on combustion and emission characteristics of chars from low-temperature and fast pyrolysis of coals with TG-MS

  • Liu, Lei;Gong, Zhiqiang;Wang, Zhenbo;Zhang, Haoteng
    • Environmental Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.522-528
    • /
    • 2020
  • To achieve the clean and efficient utilization of low-rank coal, the combustion and pollutant emission characteristics of chars from low-temperature and fast pyrolysis in a horizontal tube furnace were investigated in a TG-MS analyzer. According to the results, the combustion characteristic of chars was poorer than its parent coals. The temperature range of gaseous product release had a good agreement with that of TGA weight loss. Gaseous products of samples with high content of volatile were released earlier. The NO and NO2 emissions of chars were lower than their parent coals. Coals of high rank (anthracite and sub-bituminous) released more NO and NO2 than low rank coals of lignite, so were chars from coals of different ranks. SO2 emissions of char samples were lower than parent coals and did not show obvious relationship with coal ranks.

Fast and Easy Drying Method for the Preparation of Activated [18F]Fluoride Using Polymer Cartridge

  • Seo, Jai-Woong;Lee, Byoung-Se;Lee, Sang-Ju;Oh, Seung-Jun;Chi, Dae-Yoon
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.1
    • /
    • pp.71-76
    • /
    • 2011
  • An efficient nucleophilic [$^{18}F$]fluorination has been studied to reduce byproducts and preparation time. Instead of conventional aqueous solution of $K_2CO_3-K_{222}$, several organic solution containing inert organic salts were used to release [$^{18}F$]fluoride ion and anion bases captured in the polymer cartridge, concluding that methanol solution is the best choice. Comparing to azeotropic drying process, one min was sufficient to remove methanol completely, resulting in about 10% radioactivity saving by reducing drying time. The polymer cartridge, Chromafix$^{(R)}$ (PS-$HCO_3$) was pretreated with several anion bases to displace pre-loaded bicarbonate base. Phosphate bases showed better results than carbonate bases in terms of lower basicity. tert-Butanol solvent used as a reaction media played another critical role in nucleophilic [18F]fluorination by suppressing eliminated side product. Consequent [$^{18}F$]fluorination under the present condition afforded fast preparation of reaction solution and high radiochemical yields (98% radio-TLC, 84% RCY) with 94% of precursor remained.

Implementation and Performance Evaluation of Software Distributed Shared Memory for SMP Clusters (SMP 클러스터를 위한 소프트웨어 분산 공유메모리의 구현 및 성능 측정)

  • 이동현;이상권;박소연;맹승렬
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.30 no.7_8
    • /
    • pp.331-340
    • /
    • 2003
  • Low-cost commodity SMP(Symmetric Multiprocessor) is widely used as a node of cluster system. In this paper, we implement and evaluate the performance of SDSM system for SMP clusters. Our SDSM system provides HLRC(Home-based Lazy Release Consistency) memory consistency model. Our protocol utilize shared memory within same SMP node, so that page fetch and message passing through network can be reduced. It is implemented on 8 node of 2-way Pentium-III SMP interconnected with 100Mbps Fast Ethernet, and uses TCP/IP for transport/network layer protocol. The experiment with eight applications shows that our SMP protocol achieves maximum 33% speedup improvement and 13%-52% reduction of page fetch compared with uniprocessor protocol.

SIMMER-IV application to safety assessment of severe accident in a small SFR

  • H. Tagami;Y. Tobita
    • Nuclear Engineering and Technology
    • /
    • v.56 no.3
    • /
    • pp.873-879
    • /
    • 2024
  • A sodium-cooled fast reactor (SFR) core has a potential of prompt criticality due to a change of core material distribution during a severe accident, and the resultant energy release has been one of the safety issues of SFRs. In this study, the safety assessment of an unprotected loss-of-flow (ULOF) in a small SFR (SSFR) has been performed using the SIMMER-IV computer code, which couples the models of space- and time-dependent neutronics and multi-component, multi-field thermal hydraulics in three dimensions. The code, therefore, is applicable to the simulations of transient behaviors of extended disrupted core material motion and its reactivity effects during the transition phase (TP) of ULOF, including a potential of prompt-criticality power excursions driven by fuel compaction. Several conservative assumptions are used in the TP analysis by SIMMER-IV. It was found out that one of the important mechanisms that drives the reactivity-inserting fuel motion was sodium vapor pressure resulted from a fuel-coolant interaction (FCI), which itself was non-energetic local phenomenon. The uncertainties relating to FCI is also evaluated in much conservative way in the sensitivity analysis. From this study, the ULOF characteristics in an SSFR have been understood. Occurrence of recriticality events under conservative assumptions are plausible, but their energy releases are limited.

Release Behavior and Characterization of PCL Microcapsules Containing Lemongrass Oil (레몬그라스 오일을 함유하는 PCL마이크로캡슐의 특성과 방출거동)

  • Park, Jong-Kwon;Kim, Ji-Eun;Jeong, Noh-Hee
    • Applied Chemistry for Engineering
    • /
    • v.26 no.3
    • /
    • pp.341-346
    • /
    • 2015
  • In this study, poly ${\varepsilon}$-caprolactone(PCL) microcapsules containing lemongrass oil was prepared by the solvent evaporation method. Effects of concentrations of PCL and poly vinyl alcohol (PVA) as well as stirring speeds when preparing microcapsules were investigated. Specific peaks of lemongrass oil in PCL microcapsules at 1600 and $2900cm^{-1}$ were observed by FT-IR. The particle size and shape of microcapsules were also measured by polarizing microscope and optical microscopy. The average particle size of microcapsules decreased with increasing the stirring rate. At the stirring speed of 1500 rpm, and 1 wt% of each PCL and PVA concentrations, the smallest particles were formed. Collection efficiencies of lemongrass oil of 77.5% and 69.5% were obtained when 1.5 wt% of PCL and 2 wt% of PVA were used, respectively. In addition, the release behavior and antioxidant activity of lemongrass oil from PCL microcapsules were examined using UV-Vis spectrophotometry. When 0.5 wt% PCL and 2.0 wt% PVA were used with the slow stirring rate, microcapsules showed a fast release rate. The characteristics of antioxidant activity exhibited similar to that of the release behavior.

Guideline for Bioequivalence Studies of Controlled Release Products (서방성 제제의 생물학적동등성시험을 위한 가이드라인)

  • Seo, Hyun-Ok;Kim, So-Hee;Ahn, Mee-Ryung;Ahn, Choong-Yul;Park, Hye-Jin;Oh, Eun-Kyung;Lee, Eun-Ju;Kim, Bo-Yeon;Kim, Min-Jeong;Woo, Na-Ry;Seo, Hee-Won;Chung, Soo-Youn
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.1
    • /
    • pp.63-66
    • /
    • 2010
  • The "Guidance Document for Bioequivalence Study" was revised for adding to bioequivalence studies of controlled-release products after meal(Korea Food & Drug Administration Notification #2008-22, 2008.5.7). The bioequivalence study design for controlled-release products is $2{\times}2$ crossover under fast and fed condition in respect. For studies of controlled-release products under fed study, the same high-fat diet should be taken within 20 minutes in at least a 10-hour fasting state. The drug products should be administered 30 minutes after the meal started. A high-fat(more than 35 percent of total caloric content of the meal) and high-calorie(over 900 calories) meal is recommended as a test meal for fed BE studies.

Sibutramine Release Behavior from Microspheres Prepared by Spray-Dry Method (분무건조 방법으로 제조된 미립구에서 Sibutramine의 방출거동)

  • Park, Jung-Soo;Oh, Jung-Soo;Oh, Jae-Min;Kim, Yun-Tae;Lee, Jun-Hee;Mo, Jong-Hyun;Lee, Hai-Bang;Khang, Gil-Son
    • Polymer(Korea)
    • /
    • v.32 no.3
    • /
    • pp.193-198
    • /
    • 2008
  • Sibutramine is a highly crystalline and poorly water soluble drug as the appetite depressant for obesity treatment. In order to increase water solubility of sibutramine, microspheres including sibutramine were prepared by solid dispersion method using a spray dryer. The crystallinity and morphology of the prepared microspheres were confirmed by SEM and XRD. The morphology of micro spheres has gradually changed into spherical shape as increasing evaporation rate of solvent. According to XRD analysis, crystallinity of sibutramine in micro spheres was decreased by below 10%. Release behavior of microspheres was investiaged at pH 1.2, pH 6.8, and solubility of the sibutramine was significantly different depending on pH. The hard capsule showed fast release of sibutramine comparing with the tablet. These results demonstrated that the pharmaceutical preparation is able to control the release behaviors.

A Study on the Fire Characteristics of Aluminum Composite Panel by Large Scale Calorimeter (라지스케일 칼로리미터에 의한 알루미늄 복합패널 외장재의 연소특성에 관한 연구)

  • Yun, Jung-Eun;Min, Se-Hong;Kim, Mi-Suck;Choi, Sung-Bok
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.89-96
    • /
    • 2010
  • In this research, exterior material combustion experiment was really tested to evaluate fire risks of aluminium complex panel which is used a lot for building exterior material. As a result, We saw fast fire spreading of aluminium complex panel. The reason is polyethylene in aluminum complex panel combust spreading fast fire flame vertically. In this test, the highest heat release rate of aluminum complex panel was 1,144 kW and surface temperature which is measured by thermocouple went up to more than $903.3^{\circ}C$, that temperature is quite a higher than $660^{\circ}C$ which is aluminum melting temperature. So, fire of aluminum complex panel can be evaluated to give us severe damage both by fast fire spreading vertically and by fire spreading through openings internally. These results from real experiment will be able to use to predict fire spreading of aluminum complex panel by comparing to modeling materialization of aluminum complex panel in the future.