• Title/Summary/Keyword: fast response

Search Result 1,786, Processing Time 0.034 seconds

A Study on the Classification of Domestic Fire Detector using Response Time Index (반응시간지수(Response Time Index)를 이용한 국내 화재감지기 등급분류에 관한 연구)

  • Hong, Sung Ho;Kim, Dong Suck;Choi, Ki Ok
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.46-51
    • /
    • 2017
  • This paper presents classification of domestic fire detector using response time index. Response time is measured using fire detector distributed in Korea, and the response time index is estimated. Plunge test prescribed by FM is conducted to measure response time of fire detector. The detector used to test is fixed temperature type(thermistor and bimetal type) and rate of rise temperature type(thermistor and pneumatic type). The nominal operation temperature of fixed temperature type detector is $70^{\circ}C$ and rate of rise temperature is $15^{\circ}C/min$. The fixed temperature type is measured 7 products, and the rate of rise temperature type is measured 5 products. The results show that in case of fixed temperature type(thermistor) is classified "Quick" or "Standard" and fixed temperature type(bimetal) is not classified. The rate of rise temperature type(thermistor) is classified "Fast" or "Ultra Fast" and the rate of rise temperature type(pneumatic) is classified "Very Fast" or "Ultra Fast". The pneumatic type shows more fast response than thermistor type. Also these results indicate the fixed temperature type(bimetal) is not suitable for early stage fire detection.

Development of Fast-Response CO2 Analyzer and Analysis of Engine-out Emission during Cold Start of SI Engine (고속응답 CO2 분석기의 제작 및 이를 이용한 SI엔진에서의 실시간 배기가스 분석에 관한 연구)

  • Song, Hyun-Soo;Park, Kyoung-Seok;Park, Dong-Sun;Min, Kyoung-Doug
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.2
    • /
    • pp.133-140
    • /
    • 2009
  • A fast-response $CO_2$ analyzer has been developed for measuring the $CO_2$ concentration during transient condition of a SI engine. The analyzer consists of the non-dispersive infrared absorption method, electrical chopping system and water cooling system. The analyzer has good repeatability, linearity and permissible drift characteristic. Besides, it showed 18ms of a response to measure the $CO_2$ concentration. The fast-response $CO_2$ analyzer was applied to a single cylinder SI engine and the $CO_2$ emission was examined during engine start. Simultaneously, the standard exhaust gas analyzer, which has slow response time, was used for confirming the accuracy of the exhaust gas analysis using the fast-response $CO_2$ analyzer. The developed analyzer showed much faster responsive characteristic than that of a standard analyzer and made cycle by cycle exhaust gas analysis possible. The transient engine operating characteristics will be estimated from the $CO_2$ concentration of engine-out emissions and engine operating variables.

Study on the Fringe Field Switching (FFS) Mode with the Positive Dielectric Anisotropy for the Fast Response Time (유전율 이방성이 양인 액정을 이용한 고속응답용 FFS 모드)

  • 김미숙;김향율;송성훈;양석만;이성규;임영진;이승희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.7
    • /
    • pp.754-759
    • /
    • 2004
  • We have studied the fringe field switching (FFS) mode with the positive dielectric anisotropy for the fast response time. The factors such as the physical properties of the LC, the cell gap, and the rubbing angle were critical for the fast response time of the FFS mode. The response time became 10 ms faster when the rotational viscosity of the new LC is 20 mPa.s lower than the conventional LC. When the cell gap changed from 3.6 ${\mu}{\textrm}{m}$ to 3.0 ${\mu}{\textrm}{m}$, it was possible to achieve the total response time and response times associated with grey-to-grey transitions under 16 ms. And the response times including grey-to-grey transitions become fast as the rubbing angle decreases.

Two-Tier Storage DBMS for High-Performance Query Processing

  • Eo, Sang-Hun;Li, Yan;Kim, Ho-Seok;Bae, Hae-Young
    • Journal of Information Processing Systems
    • /
    • v.4 no.1
    • /
    • pp.9-16
    • /
    • 2008
  • This paper describes the design and implementation of a two-tier DBMS for handling massive data and providing faster response time. In the present day, the main requirements of DBMS are figured out using two aspects. The first is handling large amounts of data. And the second is providing fast response time. But in fact, Traditional DBMS cannot fulfill both the requirements. The disk-oriented DBMS can handle massive data but the response time is relatively slower than the memory-resident DBMS. On the other hand, the memory-resident DBMS can provide fast response time but they have original restrictions of database size. In this paper, to meet the requirements of handling large volumes of data and providing fast response time, a two-tier DBMS is proposed. The cold-data which does not require fast response times are managed by disk storage manager, and the hot-data which require fast response time among the large volumes of data are handled by memory storage manager as snapshots. As a result, the proposed system performs significantly better than disk-oriented DBMS with an added advantage to manage massive data at the same time.

A Study on wide viewing angle and fast response time using new VA-$\pi$ cell mode (새로운 VA-$\pi$ 셀 모드를 이용한 광시야각과 고속 응답에 관한 연구)

  • 서대식;이정호
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.4
    • /
    • pp.332-336
    • /
    • 2000
  • We have developed a novel vertical-alignment(VA) -$\pi$ cell mode that provides a wide viewing angle and fast response times for nematic liquid crystal(NLC) with negative dielectric anisotropy on a homeotropic polymide(PI) surfaces. Good voltage-transmittance curves and low driving voltages were achieved with the new VA-$\pi$ cell mode without a negative compensation film. Iso-viewing angle characteristics using the new VA-$\pi$ cell mode without a negative compensation film was also successfully observed. As well a fast response time of 31.7 ms for a new VA-$\pi$ mode was measured. Consequently the iso-viewing angel fast response time and low driving voltage characteristics using a VA-$\pi$ cell can be achieved.

  • PDF

Development of Fast-Response $CO_2$ Analyzer and Analysis of Engine-out Emission during Transient Condition of SI engine (고속응답 $CO_2$ 분석기의 제작 및 이를 이용한 SI 엔진에서의 실시간 배기가스 분석에 관한 연구)

  • Song, Hyun-Soo;Min, Kyoung-Doug
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.3079-3084
    • /
    • 2008
  • A fast response $CO_2$ analyzer has been developed for measuring the $CO_2$ concentration during transient condition of SI engine. The analyzer is based on the non-dispersive infrared absorption technique, electrical chopping system and water cooling system. The analyzer has good repeatability, linearity and permissible drift characteristic. Besides, it has 18ms with a response to measure the $CO_2$ concentration. The fast response $CO_2$ analyzer was applied to single cylinder SI engine and the $CO_2$ emission was examined during engine start. Simultaneously, the standard exhaust gas analyzer, which has slow response time, was used for considering the engine-out $CO_2$ characteristic. The developed analyzer showed much faster responsive characteristic than that of a standard analyzer and made cycle by cycle exhaust gas analysis possible. The transient engine operating characteristics will be estimated and the transient behaviors on engine-out emission and performance will be improved.

  • PDF

Measurement of Unsteady Total Pressure downstream of an 1-Stage Axial Turbine (1단 축류터빈 로터의 후류에서 비정상 전압력 측정에 관한 연구)

  • Kang, Jeong-Seek;Cha, Bong-Jun;Yang, Soo-Seok;Lee, Dae-Sung
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.318-323
    • /
    • 2005
  • To evaluate the accurate performance of turbomachinery, it is important to measure the unsteady flow phenomena downstream of the rotor blade. This paper presents the development of the fast-response total pressure probe for the measurement of the total pressure field at the exit of rotor and the result of measurement in a 1-stage axial turbine. The fast-response total pressure probe was fabricated by installing a fast-response pressure sensor near the head of a Kiel probe. And it measured the phase-lock averaged total pressure downstream of an 1-stage axial turbine. The developed probe successfully measured the accurate total pressure distribution at rotor exit and made possible to evaluate the loss distribution and the accurate performance of turbomachinery.

  • PDF

Wide viewing angle and fast response time using novel vertical-alignment - 1/4 ${\pi}$ cell mode

  • Lee, Jeong-Ho;Seo, Dae-Shik;Kim, Hyang-Yul
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.9-10
    • /
    • 2000
  • The wide viewing angle and fast response time characteristics of negative dielectric anisotropy nematic liquid crystal (NLC) using a novel vertical-alignment (VA) - 1/4 ${\pi}$ cell mode on a homeotropic alignment layer were investigated. Good voltage-transmittance curves and low driving voltage using the novel VA - 1/4 ${\pi}$ cell mode without a negative compensation film were obtained. The iso-viewing angle characteristics of NLC using the novel VA - 1/4 ${\pi}$ cell mode without a negative compensation film can be achieved. The fast response time of 24.4 ms in NLC was successfully measured. The iso-viewing angle, fast response time, and low driving voltage characteristics using the novel VA - 1/4 ${\pi}$ cell mode can be achieved.

  • PDF

A Fast Response Integrated Current-Sensing Circuit for Peak-Current-Mode Buck Regulator

  • Ha, Jung-Woo;Park, Byeong-Ha;Kong, Bai-Sun;Chun, Jung-Hoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.6
    • /
    • pp.810-817
    • /
    • 2014
  • An on-chip current sensor with fast response time for the peak-current-mode buck regulator is proposed. The initial operating points of the peak current sensor are determined in advance by the valley current level, which is sensed by a valley current sensor. As a result, the proposed current sensor achieves a fast response time of less than 20 ns, and a sensing accuracy of over 90%. Applying the proposed current sensor, the peak-current-mode buck regulator for the mobile application is realized with an operating frequency of 2 MHz, an output voltage of 0.8 V, a maximum load current of 500 mA, and a peak efficiency of over 83%.

Ultra-Fast Flash Observatory (UFFO) for early photon measurements from Gamma Ray Bursts

  • Park, Il H.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.66-66
    • /
    • 2012
  • We describe the space project of Ultra-Fast Flash Observatory (UFFO), which will observe early optical photons from gamma-ray bursts (GRBs) with a sub-second optical response, for the first time. The UFFO will probe the early optical rise of GRBs, opening a completely new frontier in GRB and transient studies, using a fast-response rotatable mirror system which redirects opitical path to telescope instead of slewing of telescopes or spacecraft. In our small UFFO-Pathfinder experiment, scheduled to launch aboard the Lomonosov satellite in June 2012, we use a motorized mirror in our Slewing Mirror Telescope instrument to achieve less than one second optical response after X-ray trigger. We describe the science and the mission of the UFFO project, including a serious version called UFFO-100 which will be launched in 2014. With our program of ultra-fast optical response GRB observatories, we aim to gain a deeper understanding of GRB mechanisms, and potentially open up the z>10 universe to study via GRB as point source emission probes.

  • PDF